30-S Series Pressure Transmitter Essential Instructions
READ THIS BEFORE USING THE PRODUCT
Thank you for choosing the 30-S Series (Pressure Transmitter).
30-S Series is an advance engineered pressure transmitter. This
series uses piezo-resistive cell which is encapsulated in silicon oil isolating the
sensor with stainless steel diaphragm. This media isolation enhances the
longevity of the transmitter while in operation. Easy operation and sleek design
are handy for confine placement.
This instruction manual is written to cover as many anticipated
applications of transmitter. The information presented in this manual is subject
to change without prior notice. Inform and educate your personnel in proper
installation, operation, and maintenance of the product. To ensure proper
performance make sure that proper technician operates, maintains and update
the product. When replacement parts are required, ensure that a qualified
person use replacement parts. Unauthorized parts and procedures can affect
the product’s performance and place the safe operation of the process at risk.
Refer installation, operation and servicing to qualified personnel.
Making cable connections to transmitter and servicing this instrument requires
access to shock hazard level voltages which can cause death or serious injuries,
therefore disconnect all hazardous voltage before accessing the electronics.
RCB Chemicals & Services does not accept any responsibility for damage or
malfunctioning of the unit due to improper usage and maintenance of the
instrument.
30-S Series comes with a 1-Year limited warranty.
PT 30-S Series PIM - R0
© 2020 RCB Chemicals & Services. All rights Reserved

Table of Contents
Section : 1 Introduction
1.1 General ................................................................................................1
1.2 Features................................................................................................1
1.3 Specifications........................................................................................2
1.4 Applications ..........................................................................................3
Section : 2 Transmitter Mounting
2.1 Thread Mounting ..................................................................................4
Section : 3 Transmitter Electrical Connections
3.1 General Guidelines................................................................................5
3.2 Power ...................................................................................................5
3.3 Cable Connection ...............................................................................5,6
Section : 4 Transmitter Calibration
4.1 Span Calibration....................................................................................7
4.2 Offset Calibration..................................................................................7
Section : 5 Maintenance
5.1 General Guidelines................................................................................. 8
5.2 Maintenance Parts................................................................................. 8
Section : 6 Technical Drawings
6.1 Dimensions............................................................................................ 9

Section : 1 Introduction
1.1 General
30-S Series is an advance engineered pressure transmitter. This
series uses piezo-resistive cell which is encapsulated in silicon oil isolating the
sensor with stainless steel diaphragm. This media isolation enhances the
longevity of the transmitter while in operation. Easy operation and sleek design
are handy for confine placement.
Open the package and inspect the pressure transmitter and related
hardware for missing or damaged parts. If there is evidence of damage, notify
the carrier immediately. If parts are missing, contact RCB Chemicals & Services
customer support representative.
1.2 Features
-Full temperature compensation throughout the range. (-40C to +125C)
-Instrument supplied in durable IP-67 enclosure with PG9 gland.
-High end encapsulated electronic components for humid and harsh
environments.
-2 adjustable potentiometers for adjusting span and offset with
corresponding analog values.
-Stainless steel SS316 transmitter material for rigid mounting on pipelines.
-4 ~ 20 mA Analog output for plant operation with respective pressure.
-Quick wires connection with transmitter through replaceable DIN valve
connector.
1 / 9

1.3 Specifications
Measuring
Range
Metric Models
0.00 –0.25 BAR
0.00 –1.00 BAR
0.00 –2.00 BAR
0.00 –4.00 BAR
0.00 –10.00 BAR
0.00 –20.00 BAR
0.00 –30.00 BAR
US Customary Models
0.00 –5.00 PSI
0.00 –15.0 PSI
0.00 –30.0 PSI
0.00 –100.0 PSI
0.00 –150.0 PSI
0.00 –300.0 PSI
0.00 –500.0 PSI
Accuracy
±0.1 % Linearity throughout the Span
±0.02 % of the Span Pressure Hysteresis
±0.02 % of the Span Repeatability
Calibration
Mode
Two Potentiometers are provided to adjust span and offset with
corresponding analog values.
Analog Output
4-20mA corresponding to Pressure, +/- 0.05mA accuracy, 0.01mA
resolution, maximum load 500Ω
Temperature
Full Temperature compensation throughout the Range
Operating Temperature range of both liquid and gas (-40°C to
+125°C)
Compatibility
Liquid Compatibility (Compatible to Stainless Steel)
Dry Compatibility (Compatible to Stainless Steel)
Wetted
Materials
SS316, SS316L & Nitrile Rubber
Mounting Type
Standard 1/4-inch male BSP threads (default threads)
-Other port threads and size can be provided on user request
Electrical
Connection
Easily replaceable Din Valve connector
Power
Requirement
+12 - 24 VDC (Maximum up to 40 VDC)
IP Class
Protection
IP 67 (with PG9 gland)
Applications
Water application, Gas compressors, Water tanks, Air Compressor,
Heat Exchangers, Oil pumps, Residential Water pumps, Boiler water
monitoring and Pneumatic Controls.
2 / 9

1.4 Applications
30-S Series can be used in different industrial applications as mentioned below:
•Water Treatment
•Gas Compressors
•Water tanks
•Air Compressor
•Heat Exchangers
•Oil Pumps
•Residential Water Pumps
•Boiler Water Monitoring
•Pneumatic Control
3 / 9

Section : 2 Transmitter Mounting
2.1 Thread Mounting
30-S Series can be mounted on pipelines where standard threads
can be provided. 1/4" female BSP standard threads will be required for
mounting of pressure transmitter. 30-S Series can be mounted on both vertical
and horizontal directions in pipelines (any rigid material) provided that the
threaded part / socket interferes the pipes.
4 / 9

Section : 3 Transmitter Electrical Connections
3.1 General Guidelines
30-S Series requires a regulated +12 - 24 VDC connection from an
external supply (not provided) to work properly.
WARNING: Don’t connect AC line power to the 30-S Series pressure transmitter.
Important Notes:
•All electrical installations must be supervised by a qualified and responsible
electrician.
•Use wiring practices that conform to all national, international and local
electrical codes.
•Don’t put sensor cables or instrument 4-20 mA output wires in the same
conduit that contains AC power wires. AC power wires require a separate
conduit to prevent electrical noise in signals.
3.2 Power
A 12 - 24 VDC power supply (max. 40 VDC) must be used to power
the 30-S Series pressure transmitter. Always separate input DC power from high
power sources, frequency drives, motors, or other electrical signal wires, which
may contribute noise to a system and cause disturbance in signal. Make sure
input DC power is stable, noise free and non-fluctuating.
3.3 Cable Connection
2 or 3 core cable can be connected to the 30-S Series transmitter
DIN valve terminal strip by connecting the wires as below mentioned diagram.
1- Unscrew the DIN valve connector.
2- Pull the screw out and remove the female connector.
3- Use pan or slotted head screwdriver in the screw hole and push it to remove
the top DIN valve casing from the male connector pins.
4- Insert the cable through DIN connector gland hole and connect the tinned
cable wires to connectors as shown in the figure below
5 / 9

Route the signal cable away from AC power wires, frequency drives, motors,
or other electrical signal wires. Do not put sensor or signal cables in conduit
that contains AC power cables and motor cables.
Image above shows the wiring connection detail.
1- For 2 core wire, connect +VE (red) tinned wire with Number 1 terminal and -
VE (black) tinned wire with Number 2 terminal.
2- Connect ground wire with ground connection terminal if required.
6 / 9

Section : 4 Transmitter Calibration
4.1 Span Calibration
30-S Series comes factory calibrated. However, if user requires calibration,
potentiometer (POT1) is located on the top of the Sensor board. Following
procedure is required to set the span.
•Use a flat head screwdriver to turn the potentiometer
and adjust the span. Do not apply extreme force as it
may damage the potentiometer.
•Span adjust increase the linearity
throughout the range. User must release
all the pressure built up in transmitter
before performing span calibration. Make
sure to contact RCB representative if
proper calibration is required.
4.2 Offset Calibration
Potentiometer (POT2) in this series is for Zero Drift Calibration. 30-S Series
handles dynamic pressure over a longer period with minimal zero
drift.
•Unscrew the mechanical connections of the
pressure transmitter and make sure the
transmitter is not baring any pressure.
•Connect any 4-20mA process meter or
dataM Controller with the input circuitry
•Note down the valve of current at no
pressure and adjust the potentiometer with
a flat head screwdriver.
•Adjust the zero value at 4.00mA.
•Re-install the connector back on the
sensor and check the sensor for any anomaly. Connect RCB Team is
the problem persist.
7 / 9
Figure: Offset Adjustment
Offset POT2
Span POT1
Figure: Span Adjustment

Section : 5 Maintenance
5.1 General Guidelines
30-S Series requires little to no maintenance for its smooth
operation. Routine maintenance is recommended for ideal operation.
Periodical calibration check is required Calibration for this transmitter should
be checked periodically for measurement check.
•Hand tight the union nut of DIN valve connector to avoid breakage.
•Use 27mm sized wrench or spanner for tightening of transmitter in
threaded fittings female fitting.
5.2 Maintenance Parts
Maintenance / replacement parts for 30-S Series are available if
required. For any requirement of parts kindly contact the RCB Chemicals
representative. Damaged electronic PCB’s, PCB components, housing and DIN
valve connector can also be replaced if required. RCB’s corresponding
personnel will remain in contact until the issue is resolved.
* User defined connection threads can be provided on request. Only BSP and
NPT standard threads can be provided up to 1/2" size.
* Threaded fittings, threaded bushes or sockets can be provided on user
request.
8/ 9

Section : 5 Technical Drawings
5.1 Transmitter Dimensions
30-S Series technical dimensions are provided hereunder:
Notes: This dimensional drawing is not to scale.
All dimensions are in mm.
9 / 9

Notes:
____________________________
____________________________
____________________________
____________________________
____________________________
____________________________
____________________________
____________________________
____________________________
____________________________
____________________________
____________________________
____________________________
____________________________
____________________________
____________________________
____________________________
____________________________
____________________________
____________________________

Notes:
____________________________
____________________________
____________________________
____________________________
____________________________
____________________________
____________________________
____________________________
____________________________
____________________________
____________________________
____________________________
____________________________
____________________________
____________________________
____________________________
____________________________
____________________________
____________________________
____________________________

Notes:
____________________________
____________________________
____________________________
____________________________
____________________________
____________________________
____________________________
____________________________
____________________________
____________________________
____________________________
____________________________
____________________________
____________________________
____________________________
____________________________
____________________________
____________________________
____________________________
____________________________

30-S Series PIM - R0
© 2020 RCB Chemicals & Services. All rights Reserved
24-A-10 SECTOR B1, TOWNSHIP,
LAHORE, PAKISTAN.
POSTAL CODE: 54770
Tel: +92 300 064 54 54
Web: www.rcbchemicals.com
Email: info@rcbchemicals.com
Table of contents
Popular Transmitter manuals by other brands

Sensorex
Sensorex TX2000 Operation manual

E+E Elektronik
E+E Elektronik EE650 user guide

Steren
Steren FMT-900 quick start guide

Continental Electronics
Continental Electronics 317C-1 instruction manual

Magnetrol
Magnetrol Kotron 805 series Installation and operating manual

Becker
Becker Centronic EasyControl EC411-III Assembly and operating instructions

Nice
Nice MYGO4 Instructions and warnings for installation and use

Bellman & Symfon
Bellman & Symfon BE1431 user manual

Wilkerson Instrument
Wilkerson Instrument DR4302 Series instructions

EMS
EMS 7940 IRIS+ Installation and programming instructions

Emerson
Emerson Rosemount 4600 quick start guide

APG
APG PT-400 Series installation guide