RDA FirePro V2 User manual

Manual (Translated)
FirePro V2 Control Unit
Door control for FS drives:
EN
FirePro V2 Control
Hardware version V2. 3
Software version V4.1
Publication Date: 02/12/2021

Door control
FireProV2
Manual
Please keep this manual with attachments carefully!
1

Door control
FireProV2
Manual
Please keep this manual with attachments carefully!
2
1 Index:
1Index:.............................................................................................................................2
2Safety instructions.........................................................................................................4
2.1 Relevant Safety requirements:...............................................................................4
3Control Print Overview.................................................................................................5
4Schedule with NES motor.............................................................................................6
5Schedule with DES motor.............................................................................................7
6Technical data ...............................................................................................................8
7Description of Control Unit...........................................................................................9
7.1 Fire alarm:..............................................................................................................9
7.2 Smoke detection:....................................................................................................9
7.3 Siren/Alarm:...........................................................................................................9
7.4 Safety edge:............................................................................................................9
7.5 Photocell protection:............................................................................................10
7.6 Light curtain:........................................................................................................10
7.7 Escape button:......................................................................................................10
7.8 Maintenance Cycle: .............................................................................................10
8Mounting.....................................................................................................................11
9Connect........................................................................................................................12
9.1 Power supply:.......................................................................................................12
9.2 Power supply 24 VDC / Battery Charger: ...........................................................13
9.3 Motor: ..................................................................................................................14
9.4 Mechanical End Switches:...................................................................................14
9.5 Digital limit switches:..........................................................................................15
9.6 Roll-off, cable break/slack cable protection: .......................................................15
9.7 UP-Stop-down operation: ....................................................................................16
9.8 Photocell: .............................................................................................................16
9.9 Light curtain:........................................................................................................16
9.10 Connecting LIGI 01-PNP light curtain: ...........................................................17
9.11 Connecting LIGI 01-PNP light curtain: ...........................................................19
9.12 Key switch:.......................................................................................................21
9.13 Fire Alarm / Smoke detector:...........................................................................21
9.14 Escape button: ..................................................................................................21
9.15 Impulse:............................................................................................................21
9.16 Safety edge:......................................................................................................22
9.17 Siren/Alarm:.....................................................................................................22
9.18 Outputs:............................................................................................................23
9.19 Smoke detection (only in combination with inflatable bellows):.....................23
10 Setting control..........................................................................................................25
10.1 Adjust limit switches NES ...............................................................................25
10.2 Adjust limit Switches .......................................................................................25
10.3 Automatic or hold to run operation..................................................................26
10.4 Duration NES Motor........................................................................................26
10.5 Protections........................................................................................................27
10.6 Impulse function...............................................................................................27
10.7 BM (Fire alarm) function.................................................................................28
10.8 RM (Smoke detection) with Reset function.....................................................28

Door control
FireProV2
Manual
Please keep this manual with attachments carefully!
3
10.9 Continuing when empty or disconnected battery:............................................29
10.10 Opening after passing digital limit switches ....................................................29
10.11 Low battery voltage..........................................................................................29
10.12 Notifications.....................................................................................................29
10.13 Maintenance counter ........................................................................................30
11 Menu........................................................................................................................31
11.1 Parameter settings 0. : ......................................................................................31
11.2 Parameter settings 1. : ......................................................................................33
11.3 Parameter settings 2. : ......................................................................................34
11.4 Parameter settings 3. : ......................................................................................35
11.5 Parameter settings 4. : ......................................................................................36
11.6 Parameter settings 5. : ......................................................................................37
11.7 Parameter settings 8. : ......................................................................................37
11.8 Parameter settings 9. : ......................................................................................37
12 Notifications ............................................................................................................38
12.1 E; Status notifications : ....................................................................................38
12.2 F; Error messages:............................................................................................39
12.3 Common Errors................................................................................................42
13 Declaration of Conformity.......................................................................................43

Door control
FireProV2
Manual
Please keep this manual with attachments carefully!
4
2 Safety instructions
This manual is translated from the original Dutch manual, In the event of discrepancies between
the two, the Dutch version shall prevail.
Read this manual carefully before starting work on this
Control unit. Check the screw connections before this control unit becomes operational.
Caution: before starting work on this control, first
Disconnected the power supply and disconnect the poles of the batteries.
Performing work on this control under tension is life-threatening & can cause serious
injuries!
Only qualified personnel with appropriate equipment and knowledge are permitted to carry
out work on this control. Qualified personnel means persons who are familiar with the
installation, configuration, commissioning & operation of electrically driven door, gate
installations. They must be able to assess the complete installation, identify possible
hazards and apply the necessary safeguards.
2.1 Relevant Safety requirements:
The safe use of this control can only be guaranteed when used as intended. The manufacturer is
not responsible for damage that has occurred due to external components or non-compliance with
these instructions.
Modifications are only permitted in accordance with the manufacturer. If modifications are applied
without the manufacturer's consent, the manufacturer's declaration is not valid.
During installation, commissioning, maintenance and control of the controller shall
Specific case applicable in compliance with the safety and accident prevention rules
to be taken.
Only apply safety products (as: safety edges and photocells which comply with applicable
standards.)
The manufacturer accepts no liability for damage resulting from operating and connection errors,
neglect of the operating instructions or inadequate maintenance and / or service, and again refers to
the possible occurrence of dangerous situations.
Despite conformity with harmonized standards, not every possible hazard can be foreseen. For this
reason, people should only enter the danger zone if this is necessary.
If in doubt about the installation, do not proceed and contact the
Technical Service for clarifications.
All information on this document (photos, drawings, characteristics and dimensions) may be
subject to change without prior notice.
Please read this manual carefully and keep this manual with
Attachments carefully!

Door control
FireProV2
Manual
Please keep this manual with attachments carefully!
5
3 Control Print Overview

Door control
FireProV2
Manual
Please keep this manual with attachments carefully!
6
4 Schedule with NES motor

Door control
FireProV2
Manual
Please keep this manual with attachments carefully!
7
5 Schedule with DES motor

Door control
FireProV2
Manual
Please keep this manual with attachments carefully!
8
6 Technical data
Power supply : 3N ~ 400VAC +/-10%, 50/60Hz
: 3 ~ 230VAC +/- 10%, 50/60Hz
: 1N ~ 230VAC +/-10%, 50/60Hz
Fuse : Max. 5A Slow
Maximum power : 2,2Kw
Maximum current : 8,5A
Control voltage : 24Vdc
Control current : 300mA
External power supply : 24Vdc
Maximum current : 100mA
Battery : Voltage: 12v
LxWxH: 151x51x94mm
Brand: CSB Battery
Type: UPS123607
Weight: 1.97 kg
Technology: AGM
Relay outputs : Potential-free switch contacts
Maximum load : 230VAC resistive last = 1A/inductive charge = 1A
Relay outputs : Various notifications as N.O. contact with 1 common
Maximum load : 24VDC resistive last =1A / inductive charge =1A
Temperature range : + 5... + 40 °C
Humidity : Max. 93% (non-condensing)
Vibration : Vibration-free mounting (e.g. concrete wall)
Enclosure Size : 400 x 300 x 150mm (L x W x H)
Protection class : IP33
Weight : 9,8kg

Door control
FireProV2
Manual
Please keep this manual with attachments carefully!
9
7 Description of Control Unit
The FirePro is a controller for failsafe drives (FS series) with mechanically adjustable limit
switches (NES) or digital Absolute Encoder (DES) and centrifugal brake. This control unit can
work both automatically and in hold to run. The operation is possible with the control buttons on
the cabinet and by means of external up-stop-down control. There is also an input for an impulse
control (e.g. pull switch) available.
A two-color LED is present on the lid which is green in normal operation and is red in case of
malfunction, fire alarm, smoke detection or power failure. The notification belonging to the red
LED is displayed on the control print display.
There is an input for the safety contact (NC) of the safety brake. If this entry is interrupted, the
door can no longer be operated.
The control unit is equipped with batteries that provide the control voltage and hold the brake in
case of a power failure if there is no fire or smoke notification. In the case of fire alarm, smoke
detection or if the batteries are empty or not present, the door will drops because the power supply
for the brake is gone. When voltage is still present, the door drops until the limit switch is closed
or the "overclose" limit switch is reached. In the menu you can set whether the door is lowered
until the normal limit switch is reached or until the "overclose" limit switch is achieved. With the
"overclose" limit switch a door can possibly drop further than it does during normal operation. A
Stop with a set time can optionally be made at a desired position, during fire alarm, smoke
detection or low battery voltage. This can only be used with CAM switches when the "overclose"
function is not in use.
7.1 Fire alarm:
After fire alarm, the door is released immediately or after extended time (parameter 3.4, 0-140
sec.) .
7.2 Smoke detection:
In the case of smoke detection, a command must be given at the reset entry after the smoke
detection is over. In the case of smoke detection, there is also a potential-free contact indicating
that the door is closed so that the air bellows for smoke sealing can be filled between the door. It
is therefore no longer possible to flee. If this contact is not used for detection, it can be
programmed in the menu to switch if a malfunction is active.
7.3 Siren/Alarm:
When the door is in motion, a potential-free switch can be used to connect a siren or other
signaling. This stops when the door stops moving. in the event of a fire alarm, there is also a
potential-free switch which can also be connected to a siren/alarm or other signaling.
7.4 Safety edge:
It is possible to connect an safety edge. This can be an safety edge by means of DW (air pressure,
1k2) contact, 8k2 safety edge or opto sensors. Under normal operation, the safety edge only works
if automatically Closing is selected. In the event of a fire alarm, smoke detection or low battery
voltage, the safety edge can be switched on or off. If it is switched on, when the safety edge is
activated, the door will stop. The menu allows you to select which safety edge has been chosen
and set the waiting time after the safety edge has been activated before the door continues to drop.
If the power supply is still present, you can also select to fully open the door and then close it
again.

Door control
FireProV2
Manual
Please keep this manual with attachments carefully!
10
7.5 Photocell protection:
The Photocell protection works only with normal operation. The door will stop and then go back
open.
7.6 Light curtain:
It is possible to connect a PNP, SSR OR OSE light curtain To the FirePro, and use it as an safety
edge.
7.7 Escape button:
There is a possibility to connect a escape button with which the door in the event of a fire alarm or
smoke detection will open to be able to escape (only if the mains power is still present ). The door
will then close again to a set time. It is also to be set that the door can still be opened with the
Open button and when releasing it the door closes again immediately (when the mains supply is
still present ). In the case of smoke detection, the door/shutter can no longer be opened if it is
completely closed, unless it is chosen to partially open the door.
7.8 Maintenance Cycle:
A maintenance cycle can be activated in the menu. If it is activated and the number of set cycles is
reached, the LED turns red and green alternately. A CS notification appears on the display (see
page 36).
When interrupting the calamities /fire alarm-contact or if the batteries are low (and
the Close option is selected), the door/roller shutter automatically closes and this can
be without safety protection!
Make sure that the batteries are never discharged completely. If the batteries are
discharged completely, they can no longer be reused. Replace the batteries.
Disconnect the battery connection if the controller is not in use.
Each year, replace the batteries preventively during maintenance.

Door control
FireProV2
Manual
Please keep this manual with attachments carefully!
11
8 Mounting
For a solid, professional installation of this control unit, the following points must be checked and
inspected:
1. The control unit must be fitted in a good, solid housing which meets the necessary
requirements for the situation on the location.
2. In order to meet the required IP value, the cable glands should be replaced if necessary. If
necessary, further sealing measures should be taken.
3. PVC insulated cabling should only be applied indoor.
4. Power supply Phase (1N ~ 230VAC-50Hz, +/-10%) Must be secured with a fuse against
short circuits and overload.
5. In case of a power cable with a 3-pole 16A CEE plug (phase, Zero & Earth) applies:
assemble a 16A. Socket in the direct proximity of the controller and fuse the power supply
in accordance with applicable standards/guidelines. After installation of the control unit
and the power cable with the wall socket, check that the screw connections are properly
tightened and that everything is properly connected.
6. In case of a connection to the installation, the following applies: Connect the control unit
to a fixed power supply line and fuse the power supply as indicated earlier. To interrupt
the power supply, a multi-pole switch must be mounted in the immediate vicinity of the
control unit which all Poles should be interrupted when shut-off.
CAUTION: The switch must have a contact opening which complies with the span
CATEGORY III for complete separation.
7. A hazard analysis of the complete installation must be made by the installer on the
location. Please note that the door or gate is appropriate secured and that it cannot bring
hazard to persons or objects.
8. The installation must at least comply with the European and local laws and standards. In
accordance with European legislation, an automatic door or gate must comply with the
Machinery Directive 2006/42/EC and in particular the following standards: EN 12445; EN
12453; EN 12635 and EN 13241-1, which makes a declaration of conformity possible.
9. The door or gate must be protected against passing the final position by means of safety-
limit switches, mechanical attacks or other safety systems.
10. The technical data of any external components such as: Photo cells, traffic lights or loop
detectors should be monitored. These may not exceed the maximum permissible load on
the control unit.

Door control
FireProV2
Manual
Please keep this manual with attachments carefully!
12
9 Connect
Figure 1 Connecting circuit board
9.1 Power supply:
The power supply 3N ~ 400VAC, 1 ~ 230VAC or 3 ~ 230VAC is connected to X1. The diagram
below lists the different schedules. The earth (PE) is connected to X3.
Connect the earth to X3!
3 Phase 400V 3 Phase 230V Single Phase
Motor in star Motor in Triangle 230V
Figure 2 Connecting mains supply

Door control
FireProV2
Manual
Please keep this manual with attachments carefully!
13
9.2 Power supply 24 VDC / Battery Charger:
The charger for the batteries and also the power supply for the controller need 230VAC as input.
This is connected to X4 according to the diagram below and the Earth (PE) on X3.
Figure 3 Connecting 230VAC voltage to power supply/charger
The output of the power supply / charger is equipped with a stitch connector. It can be plugged in
at X16 (see Fig. 4). This ensures the power supply for the control unit. The wires for the batteries
can be slid onto the poles of the batteries. Please note! The red thread is for the positive and the
black for the negative! The two 12V batteries must be connected in series so that they have a
24VDC output voltage together.
Figure 4 Connecting output power/charger

Door control
FireProV2
Manual
Please keep this manual with attachments carefully!
14
9.3 Motor:
The 3 phases or phase and zero of the motor are connected to X2 (U-V-W). With a 1 phase motor,
V is the zero, U is the closing phase and W is the opening phase. The earth can be connected under
X3 and the brake on X17(see Fig. 5).
When connecting the brake, observe the polarity correctly. The positive and negative
may not be changed!
3 Phase 400V 3 Phase 230V Only with GFA
Connect Motor in star Connect Motor in Triangle FS 15 WS drive
Figuur 5 Connecting 3 Phase and 1 Phase motor
9.4 Mechanical End Switches:
The cam/mechanical limit switches of the motor are connected to X5. Figure 6 shows the schedule
for connecting the limit switches. The extra limit switch is a NO contact. The other limit switches
are all NC contacts.
Figure 6 Connecting Cams/Mechanical limit Switches

Door control
FireProV2
Manual
Please keep this manual with attachments carefully!
15
9.5 Digital limit switches:
The digital limit switches can be connected by means of a plug connection on X19. In Figure 7,
the layout of this connection is drawn.
Figure 7 Digital limit switches
Please note! Two types of encoders can be connected, namely: Kostal and GFA.
Before they are exchanged, the controller must first be reset to factory settings by
using parameter 9.5 setting 1! Then make the installation power-less and switch the
encoder for an encoder of another type!
9.6 Roll-off, cable break/slack cable protection:
Connection X6 is for the NC contact of the roll-off, cable break/slack cable protection. If no roll-
off, cable break/slack cable protection is used, this input must be connected with a wire bridge
otherwise the door cannot be operated (see Fig. 8).
When using multiple roll- off protections, e.g. a roll-off and a cable break protection, they must be
connected in the control cabinet in series.
Figure 8 Connecting N.C./disconnection of roll-off, cable break/slack cable protection

Door control
FireProV2
Manual
Please keep this manual with attachments carefully!
16
9.7 UP-Stop-down operation:
There are two inputs for connecting a up-stop-down operation, X7 and X8. X7 is used for
operation on the lid of the cabinet and X8 can be used for an external operation. If X7 or X8 is not
used, connections 1 and 2 for the Stop function must be connected with a wire bridge (see Fig. 9).
Cover unit control External control
Figure 9 Connecting up-stop-down operation
9.8 Photocell:
A photocell can be connected to X10. There is also a 24VDC power supply on X10 for the power
supply of a photocell or any other accessories like e.g. A receiver. In addition, an entrance for the
NC contact of the photocell is also provided. If no photocell is applied, this input must be
connected with a wire bridge (see Fig. 10).
Figure 10 Connecting Photocell
9.9 Light curtain:
A PNP and SSR light curtain can be connected to X10. AN OSE light curtain can be connected to
X12. There is also a 24VDC power supply available on X10 for a light curtain. In addition, an
entrance for the NC contact of The light curtain is also provided. If no light curtain is applied,
this input must be connected with a wire bridge (see Fig. 11).
Figure 11 connecting light curtain

Door control
FireProV2
Manual
Please keep this manual with attachments carefully!
17
9.10 Connecting LIGI 01-PNP light curtain:
Transmitter
Receiver
Brown:
10-30V DC (X10 +24V)
Blanking
on *
Blue:
0V DC (X10 GND)
Brown:
10-30V DC
X10 +24V
Blue:
10-30V DC (X10 +24V)
Blanking
off**
Blue:
0V DC
X10 GND
Brown:
0V DC (X10 GND)
White:
Synchronization
> Receiver
White:
Synchronization
> Transmitter
Black***:
Test
> X13
Black:
PNP output
> X10-2
Table 1
* Connecting with door function (Blanking): Yellow + green LED on transmitter
* * Connecting without door function: Green LED on transmitter
* * * See table 2 for test function (Use option 3 in combination with P-CAP)
To connect and set Test function:
Transmitter
Option 1:
Black
Siren output
Test input
> X13-NC (Siren)
Test 24V DC
> X13-C (Siren)
Parameter 5.1 > 5 “Test function light curtain”
Option 2:
Black
Alarm output
Test input
> X13-NC (Alarm)
Test 24V DC
> X13-C (Alarm)
Parameter 5.3 > 2 “Test function light curtain”
Option 3:
Black
SD Close output
Test input
> X14-NC
Test 24V DC
> X14-C
Parameter 2.6 > 3 “Test function light curtain”
Table 2
Fine adjustment Position:
By making the transmitter's black wire more than 15 sec power-less (from the + 24VDC), the
tuning mode is turned on. On the transmitter the green and yellow LED will flash alternately and
on the receiver the green LED must be lit and the red will blink. The faster the red LED flashes the
better the adjustment. If the green LED flashes, the adjustment is too bad for use!
Exit mode by reconnecting the black wire to + 24VDC.

Door control
FireProV2
Manual
Please keep this manual with attachments carefully!
18
For doors with reflective surfaces:
When placed before the door (without a door function), it can prevent the door from closing
properly/regularly. This can happen at reflective doors. By the self-regulation in the light curtain,
the light level of the transmitter will be lowered when the door is closed. At the moment the door
opens, the light level is too weak to reach the receiver. This disables the receiver as if the light
beam is interrupted.
At the open Door , connect the Sync (white) wires briefly (less than 1 second) to the + 24VDC.
At the receiver the green LED lights up continuously and the red flashes for several seconds.
After a maximum of 10 seconds, the red LED will remain off. The learning process is over.
The light curtain software then remembers the light values at open door and the light curtain also
no longer automatically adjusts itself after this setting.
This is to prevent the light reflections from leading to unwanted reversing of the door.
Note: This only works with a disabled door function.
During the learning, there should be no interruption of the light curtain!
If this happens, the procedure can simply be repeated.
Reset to factory defaults:
Connect the Sync (white) wires for at least 15 seconds and up to 25 seconds with the + 24VDC.
Advice:
After all the settings, remove the power from the light curtain and put it back on. The light curtain,
with all the right settings, sets itself off to the correct luminosity.
Error messages:
Transmitter:
No LED lights Check power supply
Green lights > Yellow flashes every time 3x Receiver power supply is connected the wrong
way
Only yellow flashes 3x White sync cables not (properly) connected
Receiver:
No LED lights Check power supply
Red LED flashes every 2x Output cable incorrectly connected or defective
Both:
If all LED’s on both transmitter and receiver are blinking, the light curtain must be replaced.

Door control
FireProV2
Manual
Please keep this manual with attachments carefully!
19
9.11 Connecting LIGI 01-PNP light curtain:
Please note: With light curtain LIGI 07, the door function is always activated.
Figure 1; connection schedule
Transmitter
Receiver
Brown:
10-30V DC
> X10 +
> X10 –
Brown:
10-30V DC >X10 +
Blue:
0V DC
Blue:
0V DC >X10 -
White:
Synchronization
> Receiver
White:
Synchronization
> Transmitter
Black:
Test
> 0V DC
Black:
OSE output
> X12 Opto
Table 1; Connection data
Table of contents
Other RDA Control Unit manuals
Popular Control Unit manuals by other brands

Speck pumpen
Speck pumpen BADU MAT T 1 Installation and operation manual

SunSpark Technology
SunSpark Technology SST-300M user manual

SAMES KREMLIN
SAMES KREMLIN E Dispense L1K user manual

Karat
Karat K-17906T installation instructions

SOMFY
SOMFY CONTROL BOX 3S RTS installation instructions

AFRISO
AFRISO WaterControl 01 operating instructions

Pepperl+Fuchs
Pepperl+Fuchs WCS-PNG410 manual

Red Valve
Red Valve Tideflex Series Installation, operation and maintenance manual

YOKOGAWA
YOKOGAWA AQ2200-111 user manual

JA SOLAR
JA SOLAR JAM5 Series installation manual

Pepperl+Fuchs
Pepperl+Fuchs VLX-F231-B6 manual

See Water
See Water Oil Smart OSS-100 Installation and operation manual