Rduch AMWL-DSP4 Series User manual

ELEKTROAKUSTYKAELEKTROAKUSTYKA
Jan RduchJan Rduch
44-340Godów, ul. 1Maja196
tel. 032/ 47-51-803 do 5
44-340Godów, ul. 1Maja196
tel. 032/ 47-51-803 do 5
www.rduch.com.pl
www.naglosnienia.com.pl
www.naglosnienia.eu
e-mail: [email protected]
ELEKTROAKUSTYKAELEKTROAKUSTYKA
INSTRUCTION OF
AUTOMATICALLY AMPLIFIERS
TYPE:
AMWL-9DSP4/400
AMWL-9DSP4/600
AMWL-9DSP4/400+100
AMWLC-9DSP4/400
AMWLC-9DSP4/600
AMWLC-9DSP4/400+100
AMWL-DSP4
AMWLC-DSP4


1. Clues for users
- Before putting the amplifier to the 230V currency, please read the following instruction.
- Doing any unknown service to the device by any unauthorized persons makes the depriving of guarantee
and can be the cause of the worsening of technical parameters and the safety of using.
- ATTENTION! The device must be supplied from the plug-in socket with the safety circuit connected (
socket with grounding wheel).
- In case of changing the plug-in fuse, the plug must be pulled off.
- The producer can introduce some changing to the device in case of modernizations or technical
progress, without the necessity to put them into the instruction as far as the basic parameters, that are
included in this instruction, are not changed.
The accessories of the amplifier:
- service manual with the guarantee card,
- spare fuse,
- plug-in cable,
- application software CD,
2. Using and general notices.
The modern amplifiers AMC- DSP4 (Powermixer) are designed to be used in sacral buildings, large, closed areas,
conference rooms, where the high quality and the hearing of speaking is required. They are cooperating with the
50V, 70V and 100V loud speakers line and with the loud speakers set of altogether impedance > = 4 Ù.
The amplifier has got: 8 symmetrical microphone line channels to put in the dynamic, capacitive and wireless
microphones or the device with line level output and music channel to put in the record player, tuner or CD player
(LINE asymmetrical). To record, there is a separate RCA(RECORD) socket.
AMWL-DSP is a modern amplifier equipped in signaling DSP processor that enables precise correction of sound
characteristics in buildings with very difficult acoustic conditions. The amplifier activates only those microphones,
that are used in that moment, what eliminates sound surrounding influence coming from not used microphone
channels. Each 1-8 channel is equipped in symmetrical XLR input, sensitivity regulation, Phantom power.plugged
in, microphone/line switch, 100Hz high pass filter, preamplification regulation, and timbre regulation
(bas/soprano) designed in front of the case. In 1-8 channels, diodes signal the channel activity and the microphone
transposition.
3. Arrangement of elements and sockets.
The view of the front board of the AMWL-DSP amplifier.
3
7 8 9
LINE CD
HIGH HIGH
LOW LOW HIGH HIGH
LOW
RECORD
EXIT
++
--
MIC. MIC.EAK PEAK PEAK
66
1010
00
22
44
88
MASTER
000000
222222
444444
666666
1010 1010 1010
888888
SPK-ZONE-LEVEL
66
1010
00
22
44
88
ELEKTROAKUSTYKAELEKTROAKUSTYKA
ON
OFF
POWER
SETTINGS
ENTER
DIGITAL SIGNAL PROCESSOR
12345678910 11
13 14 15
12
16
PRESET 1
PRESET 2

1- a diode signaling the activity of the particular microphone channels
2- a diode signaling the transposition of a certain microphone channel
3- gain potentiometer in microphone channels
4- gain potentiometer of LINE channel
5- Cinch socket for the external sound source to be plugged in
6- recording Cinch socket
7- presets switches on
8- a pulser to service the function on the display
9- EXIT key exit from the menu
10- USB socket for the computer to be plugged in
11- gain sum potentiometer
12- switch on/ switch off of the amplifier's power
13- timbre regulation ( bas, soprano ) for microphone channels
14- timbre regulation ( bas, soprano ) for LINE channel
15- liquid crystal display
16- 6 pointed zone regulation
17- a socket of the particular loud speaker outputs and of the zone output
18- grounding
19- XLR socket DSP OUT 4 ( Subwoofer option )
20- Jack socket: MIX OUT - symetrical output channels: 9 (Line CD), 0dB and 1-8 enable with programmer
nr: 2 (MAINSUM-2)- view on page 13.
21- XLR socket: DSP OUT 1
22- grounding disconnect switch
23- XLR socket output before the equalizer and the sum
24- Jack socket 0dB output before the equalizer and the sum
25- Cinch socket asymmetric linear input
26- loudspeaker output socket ( option! only in amplifiers with the additional 100 W power tip)
27- XLR socket: DSP OUT 3
28- XLR socket: DSP OUT 2
29- grounding disconnect switch
30- XLR socket in particular channels ( 1-8 )
31- the particular outputs sensitivity regulation
32- 3 positioned switch: 1 Phantom power on/off
2 MIC / LINE switch
3 100 Hz high pass filter on / off
33- RJ 45 socket Preset steering panel input
34- output socket informing about Preset 2 switched on- this socket can also act to control (set off) an additional
speaker circiut that is used only in Preset 2.
35- 230 V ~/ 50 Hz power socket
The view of the back board of the AMWL-DSP amplifier
4
17 18 19 20 21 22 23 24
2728 29
26
25
30 31 3233
ON
ON
ON
ON
ON
ON
ON
ON
1 2 3
1 2 3
1 2 3
1 2 3
1 2 3
1 2 3
1 2 3
1 2 3
MIC. 1
MIC. 5
MIC. 2
MIC. 6
MIC. 3
MIC. 7
MIC. 4
MIC. 8
MIX OUT
XLR pin 1: GND PIN 3:
-
PIN 2: +
LINE IN 9
Unbal.
DSP OUT 4
Bal.
Bal.
Bal. Bal.
OUTPUT 0 dB
PRE MASTER,EQ
DSP OUT 1
POST MASTER,EQ
INPUT 0 dB
PRE MASTER
1V - 10k
GAIN
LEVEL
GAIN
LEVEL
GAIN
LEVEL
GAIN
LEVEL
GAIN
LEVEL
GAIN
LEVEL
GAIN
LEVEL
GAIN
LEVEL
PhantomPhantom
PhantomPhantom
PhantomPhantom
PhantomPhantom
HPFHPF
HPFHPF
HPFHPF
HPFHPF
100Hz100Hz100Hz100Hz
100Hz100Hz100Hz100Hz
100Hz100Hz100Hz100Hz
100Hz100Hz100Hz100Hz
DSP OUT 2
DSP OUT 3 GND
LIFT
GND
LIFT
GND
LIFT
GND
LIFT
Mic.(on)/Line(off)
Mic.(on)/Line(off)
Mic.(on)/Line(off)
Mic.(on)/Line(off)
100V
70V
50V
4
8
SPK-ZONE
OUT
Bal.
Bal.
Mic.(on)/Line(off)
Mic.(on)/Line(off)
Mic.(on)/Line(off)
Mic.(on)/Line(off)
COM
COM
400W
100W
100V
COM
GND
LIFT
RISK OF ELECTRIC SHOCK
DO NOT OPEN
RISK OF ELECTRIC SHOCK
DO NOT OPEN
230V~ / 50Hz
REPLACE FUSE
WITH SAME TYPE
AND RATINGS
INPUT
PANEL
PRESET
INFO OUT
PRESET 2
34
35

ESA on
- 12dB
0dB
27.1 C
dB
AMWL
DSP-4
- 6dB
11:39
Preset 1
3dB
WEEKFEW PEOPLE
4. Amplifier's menu control.
After amplifier's connection to 230V currency by a given cable and power input (switch no 12), (no 15) on the display,
Our company's logo appears, and after several seconds, there is a given screen.
eliminator pluged in
input indicators (1-4)
power terminal temperature
To service the menu, use the pulser handwheel (8) - press it, to get in the settings mode. Then, there is the next screen
“noise gate”
Turning the handwheel(8) left or right, there are other menu's parts ( previous or next parts). To come into the chosen
part press handwheel ( 8 ) (ENTER). To come back to the previous part press ( EXIT) ( 9 ).
5
clock
adjusted preset number
preset name
IN 2
IN 1
NG LIM1 EQ IN
CR
LIM2
Noise gate
c.d. Preset name
0dB
0dB
dB
±
Threshold
-90 dB
Noise gate Preset 1
white field - cursor present position
NG-Noise Gate
limiter on input 1
input equalizer
crossover
Turning the handwheel (8) left or right, the value edge of the noise gate can be adjusted from -24dB to -90dB.
Another setting part is the limiter field where, the value edge can be adjusted from -30dB to +6dB and the time of the
attack: slow, medium or fast. The same can be done for the limiter no2 - LIM2.
6dB
6dB
dB
±
Threshold
6 dB
Limiter 1 Preset 1
Attack time
Slow
IN 2
IN 1
NG LIM1 EQ IN
CR
LIM2
Noise gate
ENTER
IN 2
IN 1
NG LIM1 EQ IN
CR
LIM2
Limiter 1
ENTER
limiter on input 2
The first setting part is NG - noise gate

Equalizer part EQ.
6
ENTER
28Hz 0.0dB0.05oct
Point 1
Input EQ 1 Preset 1
PeakingEQ
IN 2
IN 1
NG LIM1 EQ IN
CR
LIM2
Input EQ
filter type choice
PeakingEQ,
LoSh6, LoSh12,
HiSh6, HiSh12
frequency
settings
()20Hz ÷ 21,2kHz
filtrer width setting
()0,05 ÷ 3 oct.
choice of one from
ten equalizer’s points
gain attenuation
adjustment
(-12dB ÷ +12dB)
Crossover part.
ENTER
Crossover
Input 1 do Output 4
Preset 1
Crossover
IN 2
IN 1
NG LIM1 EQ IN
CR
LIM2
Crossover
adjustment of output 4 to input 1 or 2
Volume
EQ 1 DLY FBS
VOL
VOL
VOL
EQ 2
EQ 3
EQ 4
DLY
DLY
DLY
FBS
FBS
FBS SB
OUT1
OUT2
OUT3
OUT4
VOL
Gain part.
ENTER gain adjustment of
particular inputs
Output equalizer part: EQ1,EQ2,EQ3,EQ4.
filter type choice
PeakingEQ,
LoSh6, LoSh12,
HiSh6, HiSh12
frequency settings
()20Hz ÷ 21,2kHz
choice of one from five
equalizer points
Gain adjustment
(-12dB ÷ +12dB)
In the same way, equalizer adjustments for 2,3,4 outputs can be programmed.
Delaying part
delaying adjustments
(0 ÷ 85m)
measurements regulation
(m, cm, ms)
filter with adjustment
(0,05oct ÷ 3oct)
-14dB -15dB 0dB
2 3 4
- dB
1
Volume Preset 1
Output 1 EQ
EQ 1 DLY FBS
VOL
VOL
VOL
EQ 2
EQ 3
EQ 4
DLY
DLY
DLY
FBS
FBS
FBS SB
OUT1
OUT2
OUT3
OUT4
VOL
ENTER
315Hz -5.0dB0.05oct
Point 1
Output 1 EQ Preset 1
PeakingEQ
Delay
EQ 1 DLY FBS
VOL
VOL
VOL
EQ 2
EQ 3
EQ 4
DLY
DLY
DLY
FBS
FBS
FBS SB
OUT1
OUT2
OUT3
OUT4
VOL
ENTER
Delay preset 1
0.0 m
Output 1
Output 2
Output 3
Output 4
Mode
0.0 m
0.0 m
0.0 m
m

FB Suppressor preset 1
Output 1
Select out
Method
Frequency
phase shifter
- Hz
Subwoofer preset 1
off
LP Filter
Frequency
Slope
200Hz
6dB/oct.
Presets preset 1
preset 1
Preset
Name
Copy preset
change
Reset settings
start
start
Clock and date preset 1
change
Set time
Set date
Date table
change
Preset 2 in sunday
change
yes
Passwords preset 1
off
Lock settings
Change password
Reset password
change
change
General options preset 1
vertical
Level meter
Mode EQ
Language
line
english
Elimanator part.
decoupling eliminator method choice
( adaptive, phase shifter)
frequency choice
for phase shifter method
output choice ( on which output
the eliminator is to be off)
Subwoofer part.
subwoofer turn on/off
filter’s cut off
frequency adjustment
(120 Hz ÷ 472 Hz)
filter slope steepness choice
Presets part.
preset choice
renaming preset
chosen preset’s name edition
Clock and date part.
General options part.
servicing mode
(only for servicemen)
Passwords part..
adjustments of the possibility of
displaying the control indicator (vertical or horizontal)
choice of displaying graphs mode EQ
(filled, line)
( language choice
polish, english)
time adjustment
date adjustment
automatic change of
presetu 2 for Sunday
back to previous settings
copy of chosing preset’s settings
to the second preset
recording dates board
for preset 2
password saving settings
turn on/off
change of password
saving seiings
adjusted password reset - new one
is automatically
set into zeros (0000)
7
FB Suppressor
EQ 1 DLY FBS
VOL
VOL
VOL
EQ 2
EQ 3
EQ 4
DLY
DLY
DLY
FBS
FBS
FBS SB
OUT1
OUT2
OUT3
OUT4
VOL
ENTER
Subwoofer
EQ 1 DLY FBS
VOL
VOL
VOL
EQ 2
EQ 3
EQ 4
DLY
DLY
DLY
FBS
FBS
FBS SB
OUT1
OUT2
OUT3
OUT4
VOL
ENTER
Presets
O
P
T
I
O
N
RTCPRESETS GENERAL
PASSWD SERVICE
ENTER
O
P
T
I
O
N
RTCPRESETS GENERAL
PASSWD SERVICE
Clock and date
ENTER
O
P
T
I
O
N
RTCPRESETS GENERAL
PASSWD SERVICE
General options
ENTER
O
P
T
I
O
N
RTCPRESETS GENERAL
PASSWD SERVICE
Passwords
ENTER

5. Amplifier's control settings by the computer
All settings introduced by the amplifier's control panel can be also done by the PC computer. To get the
possibility of the amplifier control by the computer, the program MWLEasy Manager must be installed ( it is
on the CD added). MWL Easy Manager program is created only for the configurations of AMWL-DSP4
series.
Licensor is not responsible for any harm of the program operation or for the wrong use of the program.
MWL Easy Manager installation instruction
I. Program MWL Easy Manager requires the installation of Microsoft. NET Framework 3.5 Service Pack 1
for Windows NT, XP, 98 system ( for Windows Vista and windows 7 systems - there is not necessary).
Installation file is on CD added. Dotnetfx35.exe platform can be downloaded from the Microsoft
II. In the catalogue VCM Driver you can find drivers for use the USB port from the amplifierAMWL-DSP4
(CDM2.04.16.exe)- also need to be installed
III. After dotnet35fx.exe installation MWL Easy program can be installed
Installation file is in Rduch MWLEasyMgr 2.0 Install/Setup.exe
IV. After the program installation, it should work automatically.
V. After switching the amplifier on , program automatically detects port, where the device is installed.
Switching the amplifier on, is not necessary- parameters can be set in the program and than can be recorded in the
File first and aflter that the amplifier can be switched on and the data can be copied. To join the amplifier with the
computer, in the menu “ Comunication”, the order “join” should be chosen.
8
This window appears and after choosing the device, the order “Join” should be clicked on once again .

9
place to record
the edge value (dB)
handwheel to set
the edge value (dB)
attack time
choice field
“Limiter” fold.
particular parts of settings
frequency regulation
(20Hz 21,2kHz)÷
settings part
place to open
“Settings panel”
part - “Equalizer input”.
To record the project to the file, the option "Record the project” (Ctrl+S) in menu "file" should be chosen.
gain attenuation regulation
(-12dB +12dB)÷
filter width settings
(0,05oct 3oct)÷
filter type choise
(
)
PeakingEQ,
LoSh6, LoSh12,
HiSh6, HiSh12
“options” - Presets - preset’s name

10
gain regulation of
outputs 1 - 4.
place to record the values (dB)
Crossover part - is created for ordering the output number 4 to input no 1 or no 2.
“Gain part”.
“No 1 output equalizer” part.
frequency regulation
(20Hz 21,2kHz)÷
gain attenuation regulation
(-12dB +12dB)÷
filter width setting
(0,05oct 3oct)÷
filter type choice
(
)
PeakingEQ,
LoSh6, LoSh12,
HiSh6, HiSh12
menu “Options” - language - language choice (Polish, English)
to input 1 are assigned
all inputs of the
amplifier, and to input 2
are assigned input 9
(LINE CD)
0 dB and inputs 1-8
enabled with
programmer 2
(MAINSUM-2)

11
“delay” part
delay adjustment
for particular outputs
(0m 85m)÷
place to record
the delay values
“Eliminator” part
output choice, it means, on which output the eliminator is to be turn on
eliminator’s decoupling
method choice
frequency choice for
phase shifter method
“Subwoofer” part
the Subwoofer works
after pressing the switch "ON"
(Subwoofer option is available
only in channel no 4)
subwoofer’s filter slope steepness choice
frequency settings of Subwoofer’s filter cut off
ranged 120Hz 472Hz÷

MENU
FILE
COMMUNICATION
OPTIONS
WINDOW
HELP
NEW PROJECT Ctrl+N
OPEN PROJECT Ctrl+O
SAVE PROJECT Ctrl+S
SAVE AS...
PRINT Ctrl+P
CLOSE
EXIT Alt+F4
CONNECT Ctrl+Shift+C
DISCONNECT
SAVE THE SETTINGS
LANGUAGE
PRESETS
DATE BOARD
CASCADE
PROJECT’S NAME
ABOUT THE PROGRAM
ENGLISH
POLISH
PRESET’S NAME
PRESET COPY
ZERO SETTINGS
6. Menu s tructure of MWL Easy Manager program
MWL Easy Manager
12

Microphones
1 5
2 6
3 7
4 8
lider
deputy
Setting of any priorities configuration: switching of any
switches in any channel's programmer causes the setting of
priority precedence of this channel over the previous
chosen channel. For example: switching in channel no 1
programmer, the switch no 4 down (ON) causes that
microphone no 1 can stop work of microphone no 4.
Lower configuration (picture no 3) shows the setting of the
priority for the microphone no 1 and no 2 (picture no 2).
The microphone no 1 has the priority over the
microphones from 2 to 8, and the microphone no 2 has the
priority over the microphones from 3 to 8, but is
subordinate to the microphone no 1. It means, that the
speeches of the microphones 3-8 can be stopped in any
time by the leader (1) or his deputy (2), but the speech of
the deputy (2) can be stopped only by the leader (1).
Pict. 2
1 52 63 74 8
ON
1 1 1 1 1 1 1
5 5 5 5 5 5 5
2 2 2 2 2 2 2
6 6 6 6 6 6 6
3 3 3 3 3 3 3
7 7 7 7 7 7 7
4 4 4 4 4 4 4
8 8 8 8 8 8 8
ON ON ON ON ON ON ON
1 2 3 4 5 6 7 8
Pict. 3
13
Programmer of channels(1-8) - default settings: All switches in the top position (OFF). Used to set the superiority of
microphones.
7. Prioritys.
1 2 3 4
ON
Programmer nr 4- default settings: switches 1 and 2 in position (OFF), switches 3 and 4 in position (ON).
Switch 1 - OUT2 PRE/POST GATE: upper position (OFF) POST GATE - all channels for MAINSUM-2 are assigned
to the automatic. Bottom position (ON) PRE GATE - signals are assigned before automatic.
Switch 2 - AUTO/MANUAL: upper position (AUTO) - mixer auto work function; bottom position (MANUAL) -
standard mixer work.
Switch 3 - ATTENUATION OFF: inactive microphone mute Settings, upper position - completely mute;
bottom position - mute -15 dB.
Switch 4 - LAST MIC: upper position (OFF) - recently used microphone turns off after speaking,
bottom position (ON) - recently used microphone is still active after the speaking.
ATTENTION! If you want to use a priority, this feature must be disabled (upper position OFF).
Programmer nr 4
1 52 63 74 8
ON
Programmer nr 1
top position OFF
bottom position ON
L.MIC
ATTEN.
M.AUTO
OUT2 P.
1 52 63 74 8
ON
TIME-backup time control of active microphones ATTACK- switching Microphone level control switch
Programmer nr 1 - default settings: all switches (1-8) in the
top position (OFF).
Switching any of the eight switches to the bottom position
(ON) turns off the automatic in each channel. This is useful if
you want to use one channel as a linear channel (music).
ATTENTION! If you want to use priorities, the channel switch
must be in the top position (OFF).
1 52 63 74 8
ON
Programmer nr 2
(MAINSUM 2)
Programmer nr 2 - assignment of input channels 1-8 to the output channel mix 2 (MAINSUM 2).
Assigned to input 2 (IN2) in the DSP and the output jack socket (MIX OUT).
Programmer nr 3
(MAINSUM 1)
Programmer nr 3 - assignment of input channels 1-8 to the output channel mix 1 (MAINSUM 1).
Assigned to input 1 (IN1) in DSP.
Adjusting the sensitivity of the channel LINE-CD
1 52 63 74 8
ON
programmer channels 1-8 Pict. 1

Lower configuration (pict. 4) shows the situation for three microphones, where each of them has the priority to two
ones left. In such a configuration, the priority goes to that microphone which is activated as the first one. So, when
he speech to tsomebody starts speaking to microphone no 2, the microphones no 1 and 3 are not active till the end
of the microphone no 2. Microphones no 1 and 3 behave analogically. Such a configuration is possible for all eight
microphones. Thanks to that, there is a situation, where only one microphone is always active and it makes
impossible for somebody else to interrupt, what is valuable for the order of the conference
1 52 63 74 8
ON
1 1 1 1 1 1 1
5 5 5 5 5 5 5
2 2 2 2 2 2 2
6 6 6 6 6 6 6
3 3 3 3 3 3 3
7 7 7 7 7 7 7
4 4 4 4 4 4 4
8 8 8 8 8 8 8
ON ON ON ON ON ON ON
1 2 3 4 5 6 7 8
Pict. 4
13
8. Configuration and operation of the amplifier with additional power terminal
(AMWL-9DSP/400+100).
AMWL-DSP4 amplifiers have an additional 100W power terminal (option), where
the delay can be set.
100 W terminal can be switched on output DSP OUT 2 [28],
DSP OUT 3 [27] or DSP OUT 4 [19].
It is the switch inside the amplifier. Red arrow in the picture on the right, shows where it
is. The switch is described as the DSP outputs 1-4.
DSP OUT 1 [21],
The picture shows the typical use of the amplifier in that version
The main power terminal operates on one loudspeaker’s circuit
(red colour) but the other circuit (blue color)loudspeakers are
spaced. Then, it is possible to adjust demanding delay on the
DSP additional 100W power terminal, which operates on this
loudspeaker’s circuit. The additional 100W circuit can also be
activated via connector INFO OUT PRESET 2. This means
that for Preset 1, which is activated when for example in the
church are "little people" the additional 100W circuit is inactive
(break on connector INFO OUT PRESET 2). However, when
in the church are a "lot of people" for enabled Preset 2, the
additional speaker circiut 100V is activated.
An example of the AMWL-DSP4/400+100
amplifier use
SACRYSTY
AMP.
13m

9.AMWLC-9DSP4 amplifiers.
Each microphone channel of AMWLC-9DSP4 amplifiers is additionaly equipped with Compressor-Expander.
Practically, compressor-expander allows to reach the fixed volume level independently of the input signal level.
Compressor - expander parameters settings are fixed with switches and potentiometers that are located in the upper
cover of the amplifier.
Switch on/off in given channel
Expander adjustment
in given channel
Compressor adjustment
in given channel
11. Jack pin connection:
2 - hot (+ve)
connection3 and 1
Asymmetric input
( plug in for the cable to 5m length at the asymmetric input
Phantom power off! )
2 - hot (+ve)
3 - cold (-ve)
Symmetrical input
(operating with Phantom power
recommended)
1 - chassis ground
hot(+ve)
cold (-ve)
chassing
grounding
chassis grounding
chassis grounding
signal input
terminal
ring
sleeve
symmetrical
terminal
ring
Asymmetric
output 0 dB and input 0 dB connection For the feedback eliminator, the equalizer,
the expander compressor,
the delaying line to be connected
INSERT Socket
1 - chassis grounding
coming back of the signal
chassis grounding
signal output
sleeve
10. XLR microphone pin connection:
14
Mic.1 Mic.2 Mic.3 Mic.5 Mic.6
Mic.4 Mic.7 Mic.8
ON
OFF
EKSPANDEREKSPANDER
COMPRESSORCOMPRESSOR
EKSPANDEREKSPANDER
COMPRESSORCOMPRESSOR
EKSPANDEREKSPANDER
COMPRESSORCOMPRESSOR
EKSPANDEREKSPANDER
COMPRESSORCOMPRESSOR
EKSPANDEREKSPANDER
COMPRESSORCOMPRESSOR
EKSPANDEREKSPANDER
COMPRESSORCOMPRESSOR
EKSPANDEREKSPANDER
COMPRESSORCOMPRESSOR
EKSPANDEREKSPANDER
COMPRESSORCOMPRESSOR

ONON
ONON
ONON
ONON
ONON
ONON
ONON
ONON
1 2 31 2 3
1 2 31 2 3
1 2 31 2 3
1 2 31 2 3
1 2 31 2 3
1 2 31 2 3
1 2 31 2 3
1 2 31 2 3
RISK OF ELECTRIC SHOCK
DO NOT OPEN
RISK OF ELECTRIC SHOCK
DO NOT OPEN
Made in Europe
ELEKTROAKUSTYKA
MIC. 1
MIC. 5
MIC. 2
MIC. 6
MIC. 3
MIC. 7
MIC. 4
MIC. 8
MIX OUT
XLR pin 1: GND PIN 3:
-
PIN 2: +
LINE IN 9
Unbal.
DSP OUT 4
Bal.
Bal.
Bal. Bal.
OUTPUT 0 dB
PRE MASTER,EQ
DSP OUT 1
POST MASTER,EQ
INPUT 0 dB
PRE MASTER
1V - 10k
GAIN
LEVEL
GAIN
LEVEL
GAIN
LEVEL
GAIN
LEVEL
GAIN
LEVEL
GAIN
LEVEL
GAIN
LEVEL
GAIN
LEVEL
PhantomPhantom
PhantomPhantom
PhantomPhantom
PhantomPhantom
HPFHPF
HPFHPF
HPFHPF
HPFHPF
100Hz100Hz100Hz100Hz
100Hz100Hz100Hz100Hz
100Hz100Hz100Hz100Hz
100Hz100Hz100Hz100Hz
230V~ / 50Hz
DSP OUT 2
DSP OUT 3 GND
LIFT
GND
LIFT
GND
LIFT
GND
LIFT
Mic.(on)/Line(off)
Mic.(on)/Line(off)
Mic.(on)/Line(off)
Mic.(on)/Line(off)
100V
70V
50V
4
8
SPK-ZONE
OUT
Bal.
Bal.
Mic.(on)/Line(off)
Mic.(on)/Line(off)
Mic.(on)/Line(off)
Mic.(on)/Line(off)
MODEL: AMWL-9 DSP4/400+100
POWER: 400 Watt
100W
100V
COM
COM
400W
GND
LIFT
COM
INPUT
PANEL
PRESET
INFO OUT
PRESET 2
12. AMWL-9DSP amplifier operation in the sound system.
Mixer
4Ù8Ù... ...
100V
100V
100V
100V
100V
ZONE
CD
Amplifier
Delay
Amplifier
or
ACML
column
(delay)
(delay)
(delay)
Amplifier
or
ACML
column
Amplifier
or
ACML
column
Amplifier
or
ACML
column
15
PRES.1
PRES.2
ON
OFF
Power
230V
PANEL PRESET
eg. external circiut

13. Technical data
16
AMWL-9DSP4
Output power (sinus)
10-point parametric equalizer on DSP input
Microphone inputs, symmetrical and electronic
- MIC/LINE switch
- MIC sensitivity control
- LINE sensitivity control
- impedance
- phantom power supply
- HPF filter
- bass, soprano control
- signaling
non-linear distortions
non- grounded symmetrical output
adjustable zonal output
400W, 600W, 400W+100W
13,5
<0,1%
40 - 22 000 Hz
6-degree from 0-100V
from -5°C to +40°C
100V ,70V, 50V, 8Ù, 4Ù
acoustic feedback suppressor
of adaption; phase shift
measurements: width/height/depth [mm] 443 x 135 x 340
5-point parametric equalizer
delay line 0 - 85 m
frequency band
work temperature
weight [kg]
Limiter double, peak, on DSP
input and on power end
Universal input (mono)
- input sensivity
- impedance
- bass, soprano control
inputs XLR: 1-8
yes
-40dB -15dB
-15dB +5dB
1,6 kÙ
24V DC
100 Hz, 6dB/oct.
±12dB, 100 Hz, 10 kHz,
shelving filter
green diode - aktiv channel
red diode - overdrive
input RCA: 9
-10dB +12dB
10 kÙ
±12dB, 100 Hz, 10 kHz,
shelving filter
±12 dB, 0,05 3oct.
20Hz 21,2kHz
LoSh6, LoSh12
HiSh6, HiSh12
Peak
±12 dB, 0,05 3oct.
20Hz 21,2kHz
LoSh6, LoSh12
HiSh6, HiSh12
Peak
AMWL-9DSP4
expander- compressor in channels only in AMWLC
noise gate -90dB -25dB
preset choice yes

17
RISK OF ELECTRIC SHOCK
DO NOT OPEN
RISK OF ELECTRIC SHOCK
DO NOT OPEN
AVIS: RISQE DE CHOC ELECTRIQUE !
NE PAS OUVRIR !
RYZYKO PORA¯ENIA PR¥DEM
NIE OTWIERAÆ
RYZYKO PORA¯ENIA PR¥DEM
NIE OTWIERAÆ
UWAGA
RISK OF ELECTRIC SHOCK
DO NOT OPEN
RISK OF ELECTRIC SHOCK
DO NOT OPEN
RYZYKO PORA¯ENIA PR¥DEM
NIE OTWIERAÆ
RYZYKO PORA¯ENIA PR¥DEM
NIE OTWIERAÆ
UWAGA
WARNING
TO REDUCE THE RISK OF FIRE OR ELECTRIC
SHOCK DO NOT EXPOSE THIS EQUIPMENT TO
RAIN OR MOISTURE.
WARNING OF DANGEROUS
ELECTRICAL VONTAGE! IN THE
HOUSING ARE NOT PROTECTET
ELECTRONIC COMPONENTS
WHICH HAVE A HIGHT ENOUGH
CHARGE. IT CAN BE
DANGEROUS!
THE EXCLAMATION POINT IS A
FORM OF GUIDANCE IS NEEDED
IN SUPPORT AND MEINTENANCE
OF THE INSTRUMENT
CAUTION
TO PREVENT ELECTRIC SHOCK, DO NOT
REMOVE TOP COVER, NO USER
SERVICEABLE PARTS INSIDE. REFER
SERVICING TO QUALIFIED SERVICE
PERSONNEL

18
Control card
Date ...........................
Typ .............................
Number ........................
Acoustic control :
Microphone – linear input
Linear input
Phantom power
Timbre regulation of microphone – linear input
Equalizer timbre regulation
Feedback eliminator regulation
100 Hz filter
Inactive microphone mute
“LAST MIC” function
“AUTO/MANUAL” function
Priorities for particular microphone channels
Noise and hum level control
General control :
230V AC power
Fuse
Ground measurements of the device ( according to VDE 0701 norm)
Other connections and connectors control
Optical control of the whole
Notices: ...............................
...........................................
...........................................
...........................................
...........................................
Signature ...............................
Output power
P U Z
200W/100V/50
400W/100V/25
Ù
Ù
600W/100V/16,6Ù
..............................
(Noise generator) control
..................................................
INPUT 0 dB Pre Master
INPUT 0 dB Post Master
Microphone – linear input
Linear input
Recording
Power output ( 40W, 8W, 50V, 70V, 100V)
100 Hz filter
Delay regulation
Feedback eliminator regulation
Zone regulation
Compressor – expander control
Computer control :
Connection with MWL Control program test
Correctness of saving the settings
Factory reset

GUARANTEE CARD NO.............................
Below mentioned, efficient and in a good condition device is given to the buyer on …………..according to the rules stated in
articles no 577-582 of the Penal Code. Rduch Elektoakustyka gives the buyer a guarantee on the proper working device for 36
months.
Name of this device ....................................................................................................
Rduch Elekroakustyka company, located in Godów, 1 Maja Street 196, tel. (032) 4751803 to 06, fax. (032) 475 18 07,
is called a producer in the further part of the contract.
I. OPERATING CONDITIONS
1. Plug – in power socket 230 V /50 Hz should have grounding or neutral grounding.
2. The device should be situated in a place with the temperature between +5ºC to +40ºC and of the
humidity between 8 to 80%.
3. The device should not be a subject to vibration, should not be placed near the sources of strong electromagnetic fields and
should be protected against the excessive sun exposure.
II. WARRANTY STATEMENTS
1. Warranty period starts from the date of selling the device by the producer.
2. In order to repair the device during the warranty period, it should be delivered to the company after the previous call or fax.
3. The producer provides 7 day repair period counted from the date of the adoption of the device to repair.
4. Requirement for a complaint is to provide the device in the original packing, with the guarantee card, to the place, where the
device was bought.
5. In case of the damage of the device during the warranty period, that are caused because of the producer, or hidden defects in
the material, the producer reserves the right to exchange the device into another one that is free of defects after having
examined the causes of the device malfunction.
III. BEYOND THE WARRANTY
1. The warranty does not cover the mechanical damage or the damage caused by the user, or the damage
caused by failure to comply with the universal principles of operation of the equipment and the
requirements stated in point no 1.
2. Mechanical damages or other ones, not associated with the operation of the device, result in loss of
warranty.
3. Tuning, regulations or the exchange of the fuses are not the subject to the warranty.
4. Producer, as the servicing part, reserves the rights to estimate and qualify the level of the damage.
5. In case of delivering the device in a good condition or the device that was not previously reported, the
servicing costs, cleaning, testing and transport costs are paid by the person or the company that
complain.
6. The guarantee card is invalid without the producer’ s signature, date or the company stamp.
.................................. .....................................................
Date Stamp and signature
Date Notices
Warranty and post- warranty service
Stamp and serviceman
signature
19