Real-El RESERVE-500 User manual

OPERATION MANUAL
RESERVE-500
RESERVE-1000
UPS FOR EXTERNAL BATTERIES

Technical support www.real-el.com
1
Operation Manual
RESERVE-500\1000
ENG
Congratulations on your purchase of the REAL-EL products!
Please read this Operation Manual before using the unit and retain this Operation Manual in a safe
place for future reference.
COPYRIGHT
© 2023. ENEL GROUP OU.
This manual and information contained in it are copyrighted. All rights reserved.
TRADEMARKS
All trademarks are the property of their legal holders.
NOTICE OF RESPONSIBILITY RESTRICTION
Despite the exerted efforts to make this Manual more exact, some discrepancies may occur. The
information in this Manual is given on “as is” terms. The author and the publisher do not bear any
liability to a person or an organization for loss or damage which has arisen from the information
contained in this Manual.
1. BUYER RECOMMENDATIONS
•Unpack the device carefully. Make sure there are no accessories left in the box. Check up the
device for damage; if the product was damaged during transportation, address the firm which
carried out the delivery; if the product functions incorrectly, address the dealer at once.
•Check up the package contents and availability of the warranty card. Make sure the warranty
card has a shop stamp, a legible signature or the seller’s stamp and purchase date, and the goods
number corresponds to that in the warranty card. Remember that at the loss of warranty card or
lack of coincidence of numbers you are deprived the right on warranty repair
• Do not switch on the product immediately after you bring it into a room from environment with
negative temperature! After unpacking, the product should be kept in conditions of room tempe-
rature for at least 4 hours.
CONTENTS
1. BUYER RECOMMENDATIONS....................................................................
2. SAFETY MEASURES AND PRECAUTIONS
.....................................................
3. PACKAGE CONTENTS ...........................................................................
4. TECHNICAL DESCRIPTION......................................................................
5. CONNECTION AND OPERATION ...........................................................
6. TROUBLESHOOTING ............................................................................
7. TECHNICAL SPECIFICATIONS ..................................................................
1
2
3
3
5
7
8

Technical support: www.real-el.com
2
UPS for external batteries
ENG
RESERVE-500\1000
2. SAFETY MEASURES AND PRECAUTIONS
Before using this device, be sure to read the safety rules:
• Before operation, the battery should be recharged (battery, not included) for at least 12 hours.
To do this, it is necessary to connect the UPS to the mains without load.
• The power of the connected load should not exceed the rated power indicated in the "Technical
characteristics".
• Install the UPS in temperature-controlled rooms with ventilation. During operation, the body
temperature may rise, which is a normal.
• Disconnect the UPS from the mains before connecting/disconnecting load cables to the UPS to
reduce the risk of electric shock.
• In the case of an emergency, turn offthe UPS and disconnect the power cords from the mains
and batteries.
• It is strictly forbidden to open the case of the device - there is a high voltage inside. In case of
complications, read the instructions or contact an authorized service center, the list of which is
published on the website www.real-el.com
• Do not allow liquid to get inside the device, it can cause a short circuit and electric shock. In the
event of signs of incorrect operation (sparks, smells, etc.), immediately disconnect the device from
the mains and contact the nearest service center.
• This device is not intended for use by persons (including children) with limited physical, mental or
mental capabilities, insufficient experience or knowledge; the use of the appliance by such persons
is allowed only under the condition of supervision or provision of instructions on the use of
household appliances by persons responsible for their safety.
• Do not use the device with a damaged power cord or plug, or after exposure to liquids, drops, or
any other damage. To avoid electric shock, do not attempt to disassemble or repair the device
yourself. If necessary, contact an authorized service center.
It is strictly forbidden to use the UPS in the following conditions:
–In dusty rooms and rooms containing flammable gas;
–At a temperature above 40° and below -5 degrees Celsius;
–If the humidity level is over 90%;
–In direct sunlight or near heating elements;
–In places of vibration;
–Oudoor.
• In case of fire, use only powder fire extinguisher!
• Try to place the device near the power source, then it will be easy for you to turn offthe device if
needed.
The grounding cable should be selected according to the current. All devices connected to
the UPS must be grounded. Devices without grounding or with untested grounding are
dangerous for the user and may cause malfunction of the electronic control board. Using
the wrong diameter grounding cable can be dangerous for users and device.
WARNING!
High voltage inside which can cause electric shock.

Technical support: www.real-el.com
3
ENG
Operation Manual
RESERVE-500\1000
3. PACKAGE CONTENTS
•Uninterruptible power supply – 1 pc
•Operation Manual – 1 pc
•Warranty card – 1 pc
4. TECHNICAL DESCRIPTION
Operating principle
•This device is designed to operate with lead-acid maintenance-free 12 V AGM type batteries and
belong to line-interactive uninterrupted power supply of continuous action with a long backup time.
The principle of operation is based on the conversion of DC current from external batteries into pure
sinewave AC current. The main purpose is to power household and industrial equipment critical to
the form of the input current (boiler equipment, automation systems, etc.).
•The device is equipped with an automatic voltage regulator (AVR), which allows you to ensure the
correct power supply of the load when the mains voltage increases/decreases without switching to
battery operation mode.
•The "autostart" function ensures automatic switching on after power supply. If the input voltage
after the power supply exceeds the limits of 160 V - 265 V, "autostart" is not activated, protection
against low or high voltage is activated.
Recommendations for choosing batteries
•Select the capacity of the battery depending on the power of the connected load and for the
required power reserve time, see tables 1 and 2 below. Based on the selected capacity, select the
specific battery.
•The minimum recommended battery capacity is 50Ah for the 500VA model and 100Ah for the
1000VA model.
•Battery storage conditions must meet the requirements of the battery manufacturer.
Notes:
•When using a battery of two or more units, they must be of the same type and capacity (if the
batteries have different capacities, they will have different internal resistance, as a result of which
the charge level will be different).
Table 1. Selection of batteries for the RESERVE-500
Table 2. Selection of batteries for the RESERVE-1000
3 h
5 h
7 h
1,5 h
2,3 h
3 h
0,7 h
1,5 h
2 h
12 V/50 А· h
12 V/75 А· h
12 V/100 А· h
Load 100 W Load 300 WLoad 200 W
Battery
capacity
Load 100 W
3 h
5 h
7 h
Load 200 W
2 h
3 h
4,5 h
Load 300 W
0,7 h
1 h
2 h
Load 600 W
1 h
1,5 h
2,5 h
Load 500 WLoad 400 W
7 h
12 h
15 h
12 V/100 А· h
12 V/150 А· h
12 V/200 А· h
1,5 h
2 h
3 h
Battery
capacity

Technical support: www.real-el.com
4
ENG
UPS for external batteries
RESERVE-500\1000
Description
aON/OFF switch
bTemporary mute button
cLOAD: device load indicator
dOUTPUT VOLTAGE: output voltage indicator
eOVERLOAD: overload indicator
fUTILITY: indicator of operation from the mains
gBATTERY: charge level indicator
hINPUT VOLTAGE: input voltage indicator
iERROR: error indicator
jBATTERY: battery mode indicator
kPermanent sound mute button
lCooling fan
mBattery terminals « - » « +»
nFuse protection against incorrect
battery connection
oBuilt-in power cord
pInput fuse
qOutput sockets ~230 V / 50 Hz
c
a b
dg
hij
e f
•When using multiple batteries, connect the batteries in parallel. To connect additional batteries,
purchase additional cables separately. When connecting two or more batteries, the positive
terminal of one battery is connected to the positive terminal of the other, the negative terminals are
connected in the same way.
Features
•Pure sine wave of the output voltage
•Continuous action with long backup time
•Built-in voltage stabilizer
•Microprocessor control
•Protection against short circuit in the load connected to the UPS
•Overload protection
•Protection against increased or decreased mains voltage
•Protection against external influence IP-20
•Self-diagnosis at power-on
•Indication of operating modes on the LCD display
•Mode switching time is less than 4 msec
•Autostart function
•Low noise

Technical support: www.real-el.com
5
ENG
Operation Manual
RESERVE-500\1000
kml
qon p
k l
pq
n
o
m
5. CONNECTION AND OPERATION
•Install the set (UPS + batteries) in a place with sufficient ventilation (free space around the UPS
should be at least 25 cm).
•Connect the battery (purchased separately) to the UPS using the cables in the UPS, observing
the polarity.
WARNING!!!
When connecting battery to the UPS, sparking is possible when touching the power terminals.
Before using the UPS for the first time, it is necessary to charge the battery for at least 12 hours
without load.

Technical support: www.real-el.com
6
ENG
UPS for external batteries
RESERVE-500\1000
•Connect the UPS to a single-phase mains using the power cord. It is not necessary to turn on the
UPS by button, after connecting to the mains - "autostart" function will start it automatically.
•Batteries need to be charged.
•To do this, leave the UPS on until the battery is fully charged.
•After charging the battery, press and hold the button until the device turns OFF.
•Disconnect the UPS from the network by removing the plug of the power cord from the outlet.
•Connect consumer devices to the switched-offUPS. Insert the mains plugs of the consumer
devices into the UPS sockets.
•Reconnect the UPS plug to the mains, the "autostart" function will start it automatically.
•Then turn on the connected devices (the most powerful device first and the least powerful device
last) using their switches.
Notes:
•If you need to forcibly shut down the UPS, first turn off the mains circuit breakers of the
consumers, and then turn off the UPS in the order described above. To turn on the UPS again,
press and hold the button.
•If the UPS is not used for a long time, the battery should be charged every three months.
Check the battery manufacturer's care instructions.
•If the UPS is not used for a long time, disconnect it from the mains and disconnect the
battery pack. Since this UPS implements the "autostart" function, a voltage failure in the
network will lead to an automatic start of the UPS.
"Cold start" function
•You can turn on the UPS without connecting to the mains using the "Cold start" function with the
buttona.
Note. It is not recommended to use the cold start function if a heavy load is connected.
Sound alarm and protection
•At the moment of switching to battery power (if the mains voltage disappears), the UPS emits
short beeps. During battery operation, the UPS emits periodic beeps.
•To turn offthis function for a short time, press the button bon the front control panels, or turn
offthe beeps using the button on the back panel kto permanently disable beeps.
•In the case of a low battery charge (in battery operation mode), the UPS emits sound signals.
•If a connected load is higher than the rated load, the UPS will beep and then automatically shut
down.
•In the case of an emergency situation (short circuit in the connected device or connection of the
device with a load higher than the nominal one), fuse may fail.
Storage conditions
•The temperature and humidity of the room where you intend to install the device must meet the
standards specified in the "Technical characteristics" table.
•The UPS should be stored with fully charged batteries.
•Battery storage conditions must meet the requirements of the battery manufacturer.

ENG
Operation Manual
Technical support: www.real-el.com
7
If none of the above methods can solve the problem, please seek professional advice at your
nearest service center. Never attempt to repair the product yourself.
6. TROUBLESHOOTING
Problem
The UPS is connected
to the mains, but the
indicator does not
light.
The UPS beeps and
operates in the
off-line mode even
with normal voltage in
the mains.
The UPS operates
from the mains, but
does not operate in
the off-line mode.
The UPS beeps long
during operation from
the mains.
The UPS does not
provide the expected
time of operation in
the off-line mode or it
is switched off.
Cause
1. The button ais not pressed.
2. Input fuse phas come into
action.
3. Unreliably connected cables.
1. The UPS found depressions or
surges in input voltage and has
gone to the standby mode.
2. Input fuse phas come into
action.
3. Safety fuse burned out.
4. Poor contact in the UPS connec-
tion circuits to the mains.
1. Batteries are discharged greatly.
2. Defective batteries.
3. The UPS is to be repaired.
4. Unreliably connected cables.
Overload.
1. Batteries are discharged greatly.
2. Defective batteries.
3. Unreliably connected cables.
Solution
1. Press button a.
2. Switch offthe load. Press the fuse
button. If the UPS operation is
normal, check the load power.
3. Check cable connections to
batteries.
1. It is normal phenomenon. The UPS
protects the equipment against
voltage disorders of the mains.
2. Disconnect the load. Press the
fuse button. If the UPS operation is
normal, check the load capacity.
3. Disconnect the load. You will replace
the fuse of that face value.
4. Check the UPS connection
reliability to the mains.
1. Disconnect all equipment and
charge batteries in full.
2. Replace batteries.
3. Consult with the service center.
4. Check cable connections to
batteries.
Decrease the connected load power.
1. Charge batteries in full.
2. Replace batteries.
3. Checkt the connection reliability
of cables to batteries.
RESERVE-500\1000

7. TECHNICAL SPECIFICATIONS
RESERVE-500
500 VA
300 W
~160 – 265 V \ 50 Hz
~230 V ± 10 % \50 Hz
Pure sine wave
continuous, long-acting
<4 msec
12 V unmaintained sealed
lead-acid batteries
8 A ±1 A
-5 ~ 40 °C
before 90 % (without
condensation)
-15 ~ 45 °C
140 × 180 × 350 mm
5.1 kg
RESERVE-1000
1000 VA
600 W
~160 – 265 V \ 50 Hz
~230 V ± 10 % \50 Hz
Pure sine wave
continuous, long-acting
<4 msec
12 V unmaintained sealed
lead-acid batteries
13 A ± 2 A
-5 ~ 40 °C
before 90 % (without
condensation)
-15 ~ 45 °C
160 × 240 × 390 mm
7.9 kg
Model
Output rated power
Active power
Input voltage
Output voltage
Output voltage form
Mode of operation
Switch time
Battery: connected, external
(must be purchased separately)
Charging current
Working temperature
Relative humidity
Storage temperature
Dimensions
Weight
Notes:
•
Specifications given in this table are supplemental information and cannot give occasion to
claims.
•
Technical specifications and package contents are subject to change without notice due to the
improvement of TM REAL-EL production.
ENG
UPS for external batteries
RESERVE-500\1000
Technical support: www.real-el.com
8

Models: STAB WM-500, STAB WM-10000
Manufacturer: ENEL GROUP OU, Katusepapi tn 6, Lasnamäe linnaosa, Tallinn,
Harju maakond, 11412, Estonia. Made in China.
® Registered Trademark of ENEL GROUP OU. Estonia.
Other manuals for RESERVE-500
1
This manual suits for next models
1
Table of contents
Popular UPS manuals by other brands

Toshiba
Toshiba 431A Installation and operation manual

Bicker Elektronik
Bicker Elektronik UPSI-1208DP Series user manual

Eaton
Eaton Powerware 9390 Installation and operation manual

GMP
GMP GM 110 PRO user manual

Tripp Lite
Tripp Lite LCDT Series owner's manual

Emerson
Emerson Liebert Npower 30-50 kVA installation manual