manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. RectorSeal
  6. •
  7. Control Unit
  8. •
  9. RectorSeal CLEAN CHECK User manual

RectorSeal CLEAN CHECK User manual

Other RectorSeal Control Unit manuals

RectorSeal Clean Check Operating manual

RectorSeal

RectorSeal Clean Check Operating manual

RectorSeal EASY KLEAR Operational manual

RectorSeal

RectorSeal EASY KLEAR Operational manual

Popular Control Unit manuals by other brands

Seitz 14A80 user manual

Seitz

Seitz 14A80 user manual

Wilo RS485 Installation and operating instructions

Wilo

Wilo RS485 Installation and operating instructions

Becker CentralControl CC41 Commissioning Instruction

Becker

Becker CentralControl CC41 Commissioning Instruction

SICK CDB650 operating instructions

SICK

SICK CDB650 operating instructions

Panduit NetKey NKP5E88M Series installation instructions

Panduit

Panduit NetKey NKP5E88M Series installation instructions

MX Options Concentric Petite Fitting instructions

MX

MX Options Concentric Petite Fitting instructions

Clean Water Systems Fleck 2510 Installation & start?up guide

Clean Water Systems

Clean Water Systems Fleck 2510 Installation & start?up guide

Fairchild FSB44104A user guide

Fairchild

Fairchild FSB44104A user guide

LEGRAND Wattstopper LMIN-104 installation instructions

LEGRAND

LEGRAND Wattstopper LMIN-104 installation instructions

PMK ATT10BNCS instruction manual

PMK

PMK ATT10BNCS instruction manual

Tektronix TDS3FFT user manual

Tektronix

Tektronix TDS3FFT user manual

Woodward easYgen Technical manual

Woodward

Woodward easYgen Technical manual

Balluff BNI EIP-502-105-R015 user guide

Balluff

Balluff BNI EIP-502-105-R015 user guide

NXP Semiconductors TWR-LS1021A Getting started

NXP Semiconductors

NXP Semiconductors TWR-LS1021A Getting started

Advantech PCM-3117 Startup manual

Advantech

Advantech PCM-3117 Startup manual

Danfoss MCO 101 manual

Danfoss

Danfoss MCO 101 manual

Moons' Lin Engineering R701P user manual

Moons'

Moons' Lin Engineering R701P user manual

Aventics RV1 operating instructions

Aventics

Aventics RV1 operating instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

Outer Riser Assembly
Inner Riser Assembly
◄THREADED PLUG
& ADAPTOR
Optional
FINGER HOLE
▼
▲
THUMB SCREW
NOTCH
▼
INNER RISER PIPE ►
not included
VALVE BODY ►
BUSHING ►
Bushings are provided for PVC
schedule 40x SDR-35 installations
Building
Sewer
FLAPPER ASSEMBLY ►
◄FLAPPER
Heavy Duty
Rated at 75 PSI
OUTER RISER PIPE ►
not included
Extendable Backwater Valve
1
2
3
4
5
6
7
8
9
10
INSTALLATION INSTRUCTIONS
Contact: RectorSeal®
713-263-8001 800-231-3345 713-263-7577 800-441-0051 www.rectorseal.com
PFW
VALVE BODY ▲
Flow ►◄Building
FLOW ►
◄OUTER
RISER PIPE
SEWER LATERAL ▲
Outer Riser Installation
At proper depth, install the Clean Check Valve Body
between the building and the sewer lateral, with the “FLOW”
arrow of the Valve Body pointing downstream away
from the building.
Rotate the Valve Body until the opening is facing directly
upward. A level may be used across the top of the Valve Body
to verify horizontal positioning.
Cut the Outer Riser Pipe to the required length. Cement
and insert while keeping the inside of the body clean of debris.
CAUTION: Be certain that excess solvent cement has not
impeded proper seating of the Flapper Assembly or the proper
seating of the apper sealing surface of the Valve Body.
Inner Riser Installation
Cut the Inner Riser Pipe to a length (3-1/2”) shorter than
the Outer Riser Pipe.
Cement the Flapper Assembly to one end of the Inner
Riser Pipe.
Cement the Upper Collar to the other end of the Inner Riser
Pipe, while aligning the center of the Finger Hole with the center
of the Flapper on the opposite end.
When cement is dry, loosen the thumb screw in the Upper Collar
and slide the Inner Riser Assembly – Flapper Assembly rst –
into the Outer Riser Assembly with the at sealing side of the
Flapper facing the inlet side of the Valve Body. Lower the Inner
Riser Assembly into the seating area of the Valve Body, making
certain that the Thumb Screw is inside the inside wall of
the Outer Riser Pipe and NOT on
the resting on the top edge. Seat
the Flapper Assembly by rotating
as necessary until it locks in place.
Visually inspect that the Flapper
Assembly is installed correctly.
IMPORTANT: Prior to installation
of the Threaded Adaptor & Plug
(with the Inner Riser Assembly
properly installed) cut a reference
notch into the Outer Riser Pipe.
This saw cut notch should be
aligned with the molded Notch in
the Upper Collar. For future removal,
alignment of the notches will
quickly indicate that the apper is
seated correctly.
IMPORTANT: Tighten the ¼” Stainless Steel Thumb Screw
until it seats snugly against the Inner Riser Pipe, xing the Inner
Riser Assembly in place.
Cement the Threaded Adapter to the Outer Riser Pipe
riser and screw the Threaded Plug into the
Threaded Adapter to complete installation.
Pre-Installation
•Slide Upper Collar through
Outer Riser Pipe. If collar does
not slide freely through pipe,
check to see if pipe is
“out-of-round”. If so, replace
Outer Riser Pipe.
•Backwater valves require
adequate drop between the
ood rim of the lowest xture
and burial depth of the valve in
order to function properly.
We recommend a minimum
slope of 1/4” per foot or as
recommended by the UPC
and IPC codes.
• Additional PVC bushings are
enclosed for use if needed.
Discard if not used.
Parts not provided
• Standard 8” or 6" ABS or
PVC Outer Riser Pipe of re-
quired length, and one 8" or 6"
Threaded Adaptor & Plug
(8" or 6" Outer Riser Pipe
is determined by the Clean
Check model to be used)
• Standard 4” ABS or PVC
Inner Riser Pipe of required
length.
CHECK ®
CLEAN
EXTENDABLE BACKWATER VALVE
MAINTENANCE GUIDE
▲
REFERENCE
NOTCH
See step 8
RectorSeal brand solvent cements are approved to meet manufacturer’s recommendations.
Hubsett™Test Coupling
Tom-Kap™Flush-t cleanout adaptor & plug
I
N
-
S
T
O
C
K
R
E
A
D
Y
T
O
S
H
I
P
RectorSeal®
2601 Spenwick Drive - Houston, TX 77055
ph: 713.263.8001 - 800.231.3345
fax: 713.263.7577 - 800.441.0051
www.rectorseal.com - Like Us on Facebook
Scan for more info
Scan for more info
Application
•Uniquely designed coupling and test device all in one
• Allows the buildings drain waste and vent system to be connected to the
sewer line prior to the initial test •Easily removed with one
quick pull on the release cord
Recommended for
•ABS •PVC
Includes
•Dome •Coupling •Float
Application
•Threaded adapter cements inside the pipe, providing a
flush-finished cleanout for DWV systems
Recommended for
•Schedule 40 •SDR-35 •Foam core
Includes
•Top fitting •Cap
FEATURES
• Holdspressureeverytime
• Safetouse
• Nopumporspecialtools
 needed
• Testwithairorwater
• 12ft.cord
FEATURES
• Reducesinstallationcost
• Simplifiesrough-in
Coupling
Dome
Float