2- 3 I/O Port
2-3-1 Install and Remove Cable
Please follow the steps listed below to install the
cable. See -Figure 2-7.
Use the small slotted screwdriver to press the
corresponding button of cable groove. Insert the
cable into the groove and then release the
screwdriver.
2-3-2 Remove Cable
Please follow the steps listed below to remove the
cable.
Use the small slotted screwdriver to press the
corresponding button of cable groove. Remove the
cable out of the groove and then release the
screwdriver.
2-3-3 Alarm Input and Output
Please refer to the following figure for alarm input
information. See -Figure 2-8
Alarm input: When the input signal is idle or
grounded, the device can collect the different
statuses of the alarm input port. When the input
signal is connected to the 5V or is idle, the device
collects the logic “1”. When the input signal is
grounded, the device collects the logic “0”.
Please refer to the following figure for alarm output
information. See - Figure 2-9
Port NO and Port C composes an on-off button to
provide the alarm output.
If the type is NO, this button is normal open. The
button becomes on when there is an alarm output.
If the type is NC, this button is normal off. The
button becomes off when there is an alarm output.
Please refer to the following figure for external IR
light information. See -Figure 2-10
IR synchronization input signal. When the
external IR light is on, the signal cable from the
board outputs the 3.3V/1mA. It outputs the 0V
when the IR light is off.
Installation
Select the “Open Device Web” item; you can go to the
corresponding web login interface. See - Figure 3-3
If you want to modify the device IP address without
logging in the device web interface, you can go to the
configuration tool main interface to set.
In the configuration tool search interface (Figure 3-3),
please select a device IP address and then double click it
to open the login interface. Or you can select an IP
address and then click the Login button to go to the login
interface. See -Figure 3-4.
In -Figure 3-5, you can view device IP address, user
name, password and port.
Please modify the corresponding information to login.
Please note the port information here shall be identical
with the port value you set in TCP port in Web Network
interface. Otherwise, you can not login the device.
If you are using device background upgrade port 3800
to login, other setups are all invalid.
After you logged in, the configuration tool main interface
is shown as below. See 3-6
For detailed information and operation instruction
of the quick configuration tool, please refer to the
Quick Configuration Tool User's Manual included in
the resources CD.
3-1 Overview
Quick configuration tool can search current IP
address, modify IP address. At the same time, you
can use it to upgrade the device.
Please note the tool only applies to the IP
addresses in the same segment.
3-2 Operation
Double click the “ConfigTools.exe” icon; you can
see an interface is shown as in - Figure 3-1.
In the device list interface, you can view device IP
address, port number, subnet mask, default
gateway, MAC address and etc.
Select one IP address and then right click mouse,
you can see an interface is shown as in - Figure3-2.
Note:
You can set the IP address, subnet mask and
gateway for the RLC and PC. Please note RLC IP
address and PC IP address shall be in the same
network segment if there is no router. RLC default
IP address is 192.168.1.108. If there is a router,
please set the corresponding gateway and subnet
mask.
The factory default user name is admin and
password is admin. For security reasons, please
modify your password after you first login.
For detailed WEB operation, please refer to the
RLC Web Operation Manual in the resource CD.
Quick Configuration Tool Web operation
4 Web Operation
This series IPC product support the Web access
and management via PC.
Web includes several modules: monitor channel
preview, system configuration, alarm and etc.
4-1 Network Connection
Please follow the steps listed below for network
connection.
- Make sure the IPC has connected to the
network properly.
- IPC IP address and PC IP address shall be in
the same network segment. IPC default IP
address is 192.168.1.108. If there is router,
please set the corresponding gateway and
subnet mask.
- Use order ping ***.***.***.***(* IP camera
address) to check connection is OK or not.
4-2 Login and Logout
Open IE and input IP camera address in the
address bar.
For example, if your camera IP is 192.168.1.108,
then please input http:// 192.168.1.108 in IE
address bar. See -Figure 4-1
The login interface is shown as below.
See -Figure 4-1
Please input your user name and password.
Default factory name is admin and password is
admin.
Note:
For security reasons, please modify your
password after you first login. see - Figure 4-2
If it is your first time to login in, system pops up
warning information to ask you whether install
control web rec. cab or not after you logged in for
one minute. Please click OK button, system can
automatically install the control. When system is
upgrading, it can overwrite the previous Web too.
If you can't download the ActiveX file, please check
whether you have installed the plug-in to disable
the control download. Or you can lower the IE
security level. See - Figure 4-3 and 4-4.
After you logged in, you can see the main window.
See - figure 4-5.
Please refer to the Web Operation Manual included
in the resource CD for detailed operation
instruction.
O: Indicates that the concentration of the
hazardous substa nce in all homogeneous
materials in the parts is below the relevant
threshold of the SJ/T11363-2006 standard.
X: Indicates that the concentration of the
hazardous substance of at least one of all
homogeneous materials in the parts is above the
releva nt thresh old of the SJ/T11363- 2006
standard. During the environmental-friendly use
period (EFUP) period, the toxic or hazardous
substance or elements contained in products will
not leak or mutate so that the use of these
(substances or elements) will not result in any
severe environmental pollution, any bodily injury or
damage to any assets. The consumer is not
authorized to process such kind of substances or
elements, please return to the corresponding local
authorities to process according to your local
government statutes.
Note:
- This quick start guide is for reference
only. Slight difference may be found in
user interface.
- All the designs and software here are
subject to change without prior written
notice.
- All trademarks and registered trademarks
are the properties of their respective
owners.
- If there is any uncertainty or controversy,
please refer to the final explanation of
us.
- Please visit our website or contact your
loca l se rvic e e n gine er f or m ore
information.
Input your
address here
Component
Name
Circuit Board
Component
Device Construction
Material
Wire and Cable
Packing
Components
Accessories
Pb Hg Cd CrVI PBB PBDE
Toxic or Hazardous Materials or Elements
Figure 3-1
Figure 4-1
Figure 4-2
Figure 4-3
Figure 4-4
Figure 4-5
Figure 3-2
Figure 3-3
Figure 3-5
Figure 3-6
Figure 2-7
Figure 2-8
Figure 2-10
Figure 2-9