Select the “Open Device Web” item; you can go to the
corresponding web login interface. See -Figure 3-3.
If you want to modify the device IP address without
logging in the device web interface, you can go to the
configuration tool main interface to set.
In the configuration tool search interface (Figure 3-4),
please select a device IP address and then double click
it to open the login interface. Or you can select an IP
address and then click the Login button to go to the login
interface. See -Figure 3-4.
In -Figure 3-4, you can view device IP address, user
name, password and port. Please modify the
corresponding information to login.
Please note the port information here shall be identical
with the port value you set in TCP port in Web Network
interface. Otherwise, you can not login the device.
If you are using device background upgrade port 3800
to login, other setups are all invalid.
3.1 Overview
Quick configuration tool can search current IP
address, modify IP address. At the same time, you
can use it to upgrade the device.
Please note the tool only applies to the IP
addresses in the same segment.
3.2 Operation
Double click the “ConfigTools.exe” icon; you can
see an interface is shown as in -Figure 3-1.
In the device list interface, you can view device IP
address, port number, subnet mask, default
gateway, MAC address and etc.
Select one IP address and then right click mouse,
you can see an interface is shown as in -Figure 3-2.
Note:
You can set the IP address, subnet mask and
gateway for the RLC and PC. Please note RLC IP
address and PC IP address shall be in the same
network segment if there is no router. RLC default
IP address is 192.168.1.108. If there is a router,
please set the corresponding gateway and subnet
mask.
The factory default user name is admin and
password is admin. For security reasons, please
modify your password after you first login.
For detailed WEB operation, please refer to the
RLC Web Operation Manual in the resource CD.
After you logged in, the configuration tool main interface
is shown as below. See -Figure 3-5
For detailed information and operation
instruction of the quick configuration tool, please
refer to the Quick Configuration Tool User's Manual
included in the resources CD.
O: Indicates that the concentration of the hazardous substance in
all homogeneous materials in the parts is below the relevant
threshold of the SJ/T11363-2006 standard.
X: Indicates that the concentration of the hazardous substance of
at least one of all homogeneous materials in the parts is above
the relevant threshold of the SJ/T11363-2006 standard. During
the environmental-friendly use period (EFUP) period, the toxic or
hazardous substance or elements contained in products will not
leak or mutate so that the use of these (substances or elements)
will not result in any severe environmental pollution, any bodily
injury or damage to any assets. The consumer is not authorized
to process such kind of substances or elements, please return to
the corresponding local authorities to process according to your
local government statutes.
Note:
This quick start guide is for reference only. Slight
difference may be found in user interface.
All the designs and software here are subject to change
without prior written notice.
All trademarks and registered trademarks mentioned are
the properties of their respective owners.
If there is any uncertainty or controversy, please refer to
the final explanation of us.
Please visit our website or contact your local service
engineer for more information.
Quick Configuration Tool Quick Configuration Tool Quick Configuration Tool
· There is no player.
·
There is no DX8.1 or higher.
·
For the MEDIA PLAYER, there shall be
Div X503Bundle.exe plugin if you play
the .AVI file.
For Windows XP user, you need to
install the plugin DivX503Bundle.exe
and ffdsho-2004 1012.exe.
After you modified the important setup,
please reboot the device via the
software to make sure the setup has
been updated to the storage medium.
To guarantee
setup update
I can not play the
download file.
Power adapter · The general power adapter can work
ranging from 0℃ to 40 ℃. The device
may result in unstable power supply
when the temperature exceeds the
working temperature.
Please replace an industry-level power
adapter if you are using in the harsh
environments.
I can not boot up
the device or
operate properly.
The water leakage
occurred.
Please click RESET button for at least
five seconds to restore factory default setup.
The glass front cap has sustained
heavy push or strike.
The waterproof plug of the rear cap
becomes loosen.
The unauthorized front or rear cap
remove many result in water leakage.
IR video is poor. · Do not use the proper supplying power.
The IR light can not turn on completely.
The object is out of the IR distance
range of current device.
IR-CUT does not turn to the night mode.
The photosensitive chip of the front-end
can not sense the IR light.
I can not upgrade
the device via
network.
When network upgrade operation failed,
you can use port 3800 to continue
upgrade.
I can not login the
client-end or the
WEB
· For Windows OS 98 or Windows ME
user, if you can not install the client-end
or can not view after the installation.
We recommend the win2000sp4 OS or
install the client-end of the low version.
· The Active X control is blocked.
· The display card version shall be dx8.
1 or higher.
· Network connection error occurred.
· Invalid network setup.
Invalid user name or password.
Bug
Component
Name
Circuit Board
Component
Device Case
Wire and Cable
Packing
Components
Accessories
Pb Hg Cd Cr VIP BBPBDE
Toxic or Hazardous Materials or Elements
Figure 3-1 Figure 3-3
Figure 3-4
Figure 3-2
Figure 3-5
!
!
!