Redwall V Series User manual

- 1 -
ENGLISH FRANÇAIS DEUTSCH ITALIANO ESPAÑOL
2.3-4.0 m
(7.6-13 ft.)
F
6 4 2 5 3 1
F 6 F 4 F 2 F 5 F 3 F 1
E 6 E 4 E 2 E 5 E 3 E 1
D 6 D 4 D 2 D 5 D 3 D 1
C 6 C 4 C 2 C 5 C 3 C 1
B 6 B 4 B 2 B 5 B 3 B 1
E
D
C
B
Area Masking Seals
3020 (521203)
1 2
3
4 5 6 7
B1
C1
D1
E1
F1 F6
2F 3F 4F 5F
E5E2 E3 E4
D5D2
C5C2 C3 C4
B5B2 B4
3D 4D
B3
E6
D6
C6
B6
Area View Finder
The detection zones of Redwall-V and Redwatch-V, which may be
cause of false alarms can be eliminated by masking.
1. To confirm detection zones
Use optional Area View Finder, AVF-1
2. To eliminate unnecessary detection zones
a. Use supplied area masking seals.
b. Use equiped area masking plates.
The following shows an example;
Detection zones and related segments of the mirror of SIP-3020.
See step 4 and 6.
FAR
NEAR
7
6
5
4
3
2
1
B6
C6
D6
E6
B3
C3
D3
E3
F3
B2
C2
D2
E2
F2
B1
C1
D1
E1
F1
B4
C4
D4
E4
F4
B5
C5
D5
E5
F6
F5
INSTALLATION AND MAINTENANCE NOTES
Warning
Failure to follow the instructions provided
with this indication and improper handling
may cause death or serious injury.
Caution
Failure to follow the instructions provided
with this indication and improper handling
may cause injury and/or property damage.
The check mark indicates recommendation.
The nix sign indicates prohibition.
Warning Caution
Never repair or
modify product
Hold the main unit
securely when you
install or service it.
If you remove your
hands from the main
unit when cables are
connected to it, the
main unit may fall
and the connector
cables may break
or the circuit board
may be damaged.
Caution
Verify that the
power is off before
connecting the
wiring.
2
PARTS IDENTIFICATION
1
No. 59-1494-6 1710-11
No. 59-1494-6 1710-11
INSTALLATION INSTRUCTIONS
Synthesized Intelligent PIR
REDWALL-V series
Synthesized Intelligent PIR
REDWALL-V series
FEATURES
* Intelligent PIR Detection System
- Detection of ambient temperature and illuminance for
automatic sensitivity management
- Advanced detection algorithm
- Three dual pyro-elements with patented Double Conductive
Shielding
* Anti-vandalism functions
- Anti-rotation function with accelerometer
- Anti-masking function with photo-beam
- Reinforced polycarbonate housing
- Max. 4 m (13 ft.) installation height
saeraraf/raenrofrotcelesytivitisnestnednepednI*
* Detection logic selector
* Detection range selector
* Independent N.C. and N.O. outputs
* Adjustable alarm interval time
•SIP-3020CAM DN (EU), SIP-3020CAM DN (US)
)W/B(thgiN/)ruoloc(yaD:egamiaremacytilauq-hgiH*
* 480 TV lines
* Varifocal lens 3-9 mm
REDWALL-V REDWATCH-V
: Synthesized Intelligent PIR
SIP-3020
SIP-4010
SIP-404
•
•
•
: Synthesized Intelligent PIR
with D/N camera
SIP-3020CAM DN (EU)
SIP-3020CAM DN (US)
•
•
SIP-3020CAM DN
Mount the detector so that the majority of
traffic flow is across the detection pattern.
*1: Not used for the SIP-4010 and SIP-404.
2-1
INSTALLATION HINTS
Base
Fixing screw
for the base
Main unit
Masking plate for near
area (*1)
Fixing rubber
form (*1)
Window
Fixing screw
for the cover
Cover
Far area mirror
Masking plate for far area
Fixing rubber form
Adjustment screws
(two facing each other)
Angle adjustment guide
Camera unit
Near area mirror
Arrow marking
Fixing screw
Nylon wire
loop
When servicing, the sensor
can be hooked onto the base
using the nylon wire loop.
REDWALL-V SIP-3020
UL
* UL/c-UL Listed * UL-1: SIP-3020CAM DN (EU) and
-3020CAM DN (US) are not listed by UL
*
UL-2: SIP-3020, -4010 and -404 are recommended not to be connected to an alarm initiating
circuit but may be connected to a trouble alarm circuit if nuisance trips are not tolerable.
* SIP-4010 and SIP-404 do not have a
masking function.

- 2 -
3-1
Wall Mounting
Attach the paper template (an accessory) onto the wall,
and drill a 6-mm dia. mounting hole and a cabling hole.
Insert the anchor bolt (an accessory) into the board mount
hole.
Using an allen key, remove the main unit from the base.
Drill through the bushing of the wiring hole, pass the cable
through the hole, and secure the base to the wall.
Connect the cable to the terminal block (see Step 3-3).
Mount the main unit onto the base.
Cautions>>
When mounting the main unit, take care not to trap the
nylon wire loop. Also, take care not to get your fingers
caught.
Check to see that the various settings and operations are
correct.
Caution>>
When the red LED flashes after the power turns on,
this signifies that the system is warming up. Wait for
approximately 60 seconds.
INSTALLATION AND ANGLE ADJUSTMENT
3
(1)
(2)
(3)
(4)
(5)
(6)
3-2
Inside View of the Base
3-3
WIRING
*1: TAMPER terminals to be connected to a 24 hour supervisory loop.
TROUBLE
OUTPUT
Trouble out is used for anti-masking signal. When
an object is placed close to the lens surface, for
a period of more than 100 seconds (approx.), the
IR anti-masking circuit will activate and generate a
trouble signal.
TAMPER
OUTPUT
It is detected when the cover is opened.
It is detected when the main unit is removed from
its base.
Anti-Rotation:
Damage sustained by the main unit is detected.
If the main unit is impacted in a horizontal or
vertical direction and if the position of the main
unit has changed, damage sustained by the main
unit will be detected.
Waterproof seal
(Do not remove
this seal.)
Base
Bushing of wiring
hole (Ф18)
Open wiring cap
Main unit connector
Wall mounting hole
BNC terminal
(SIP-3020CAM DN ONLY)
Wall mounting hole
Bushing of wiring
hole (Ф18)
Wiring terminals
1Loosen the
fixing screw
for the
base.
2Open.
3Unplug
the cable
connector.
4Pull out.
BNC terminal
(SIP-3020CAM DN ONLY)
POWER INPUT
TAMPER OUTPUT *1
ALARM OUTPUT (N.C.)
ALARM OUTPUT (N.O.)
TROUBLE OUTPUT
SPARE
4Tighten and secure
the fixing screw for
the base.
2Connect the
connector.
3Close.
1Insert and
secure here.
Nylon
wire
loop
Distance from the ground to
the bottom of the template
must be between 2.3 m (7.6 ft.)
and 4 m (13 ft.).
Unit:mm
Wiring hole (M20 x 1.5)
* UL-3: All relay outputs of Alarm/Trouble are resistive load only.
* UL-4: UL requires that the detector is to be connected to a UL listed Burglar power
supply Class 2, capable of providing a input range of not greater than 11 VDC – 26
VDC, 50 mA and battery standby time of 4 hours.
* UL-5: The equipment shall be installed in accordance with the National Electrical
Code, NFPA 70.
Name Function

- 3 -
ENGLISH FRANÇAIS DEUTSCH ITALIANO ESPAÑOL
DETECTION AREA SETTING
You can adjust the detection area by 90 degrees in a horizontal
direction and by 10 degrees in a vertical direction.
Correct the vertical detection angle according to the mounting
height of the sensor unit.
Applicable
models
SIP-3020 SIP-4010 SIP-404 SIP-3020CAM DN
10°
10°
90° 90°
SIP-3020CAM
D
Applicable
models
SIP-3020 SIP-4010 SIP-404 SIP-3020CAM DN
10°
10°
90° 90°
Cautions>>
To rotate the main unit counterclockwise, loosen the
RHside adjustment screw. To rotate the main unit
clockwise, loosen the LH-side adjustment screw.
Otherwise, you may find it difficult to tighten or you may
find that you cannot tighten the adjustment screw when
you are securing the main unit.
To rotate the unit counterclockwise
To rotate the unit clockwise
4
Power wires should not exceed the following lengths.
WIRE SIZE SIP-3020/SIP-4010/SIP-404 SIP-3020CAM DN (EU)
SIP-3020CAM DN (US)
12V DC 14V DC 24V AC 12V DC
0.33 mm2
(AWG22)
530
(1740)
930
(3050)
960
(3150)
90
(300)
0.52 mm2
(AWG20)
830
(2720)
1460
(4790)
1520
(4990)
150
(490)
0.83 mm2
(AWG18)
1330
(4360)
2340
(7680)
2430
(7970)
240
(790)
m (ft.)
Adjust the angle of the main unit in a horizontal direction so
that you can cover the desired detection area.
Adjust the angle of the main unit in a vertical direction so
that you can cover the desired detection area.
Cautions>>
If the mounting wall is at an angle, the arrow of the
main unit may exceed the top or bottom limit of “Angle
adjustment guide”. Always check this using the area
viewfinder or the walk tester. If the detection area is
too high or too low, an object outside the detection
area may be detected or incorrect object detection may
occur.
Remove the cover.
Cautions>>
The cover is linked to the main unit by nylon wire loop so
that the cover does not fall. Do not pull the cover using
excessive force.
(1)
(2)
(3)
When mounted
at a height of
2.3 meters
(7.6ft.)
When mounted at a
height of 4.0 meters (13ft.)
3Rotate the main unit.
2Loosen the adjustment screw.
4Tighten the adjustment screw slightly.
Hooks
3Slide the cover downward
and release the hooks.
1Loosen two xing screws for
the cover and pull out the
cover until it stops.
Cover
2Hold the heads of both cover xing screws with your
hands, and pull down and remove the bottom section
of the cover from the main unit.
Adjustment
screw
Align the arrow of the main
unit with the “Angle adjustment
guide” of the adjustment
screw. The main unit is usually
adjusted within the width of this
guide.
1Loosen the xing screw for
the base.

- 4 -
Mount the area viewfinder.
Mounting tips>>
Engage the convex section of the area viewnder xing
arms with the notches of the main unit, and insert and
mount the arms.
Mount the area plate so that an arrow of the plate
center section faces upward and the letter surface can
be seen.
Insert the area plate into the top and bottom grooves of
the area viewnder until the plate is stopped by the ribs.
404 (521205)404 (521205)
4010 (521204)4010 (521204)
SIP-3020 SIP-4010
SIP-404
SIP-3020CAM DN
Fine adjust the main unit angle in vertical and horizontal
direction by observing the target area through the area
viewfinder.
•
•
•
(4)
(5)
3Locate the center circle of the area
plate on the center circle of the lens
of the area viewnder, and check the
detection area pattern on the area
plate and the background image.
*Each letter on the area plate
corresponds to each mirror number
(see Step 8-2).
* You cannot observe mirror
numbers B1 to F1 and B6 to F6
(shown at right) of the SIP-3020
area plate through the inspection
window. Check them using the
walk tester.
Adjusting tips>>
If you experience any of the following, see Step 10.
Cautions>>
The area viewnder is a supporting tool for detection
area adjustment.
After you have adjusted the detection area using the
area viewnder, always check the area using the walk
tester.
Never look directly into the sun through the area
view nder.
After you have used the area viewnder, store it away
from direct sunlight.
Securely tighten the adjustment screw that you have
loosened.
Connect the walk tester (optional) to the sensor unit, and
check that the detection area is correct.
REDWAVE
REDWAVE
MICROWAVE
REDWAVE
ALARM OUTPUT
CELLBATTERY
POWER
SUPPLY
FROM
SENSOR
POWER OFF
REDWAVE
PIR NEAR
REDWAVE
PIR FAR
MEGARED
FAR
MEGARED
NEAR
REDWALL
REDWIDE
WALKTESTER
REDWALL
REDWIDE
MEGARED
CONNECTION
SELECT
SWITCH
MODE
SELECT
SWITCH
POWER
SELECT
SWITCH
OPM-WT
(OPM-WT) (AWT-3)
1When the power selector switch is turned to “POWER
SUPPLY FROM SENSOR” position after plugging
the cable into the walk tester connector, a continuous
beeping sound will be heard.
2When a pedestrian first enters the detection area, the
strong and weak beeps will sound alternately.
3When the entirety of a pedestrian’s body is detected, the
strong beep will sound continuously.
•
•
•
•
(6)
(7)
Area plate
(an accessory)
Determine the
detection direction
(see Step 5-1).
Put the red string
round the main unit.
Insert and
mount to
the main
unit.
Red string to
hold the main unit
Center circle
of the lens
Area viewnder AVF-1 (optional)
Inspection window
Insert the area
plate into the slot.
Fixing arms
Notch Convex
section
Grooves
Ribs
Arrow
marking
1To change the direction of the inspection
window, rotate the area viewnder in a
horizontal direction until it clicks and stops.
2Move your face close to the viewnder
so that your eye comes within 5 mm of
the inspection window (lens surface).
Center circle of the lens
Center circle of the
area plate
The detection area is
inside the frame
border.
Invisible area
The sensor area is extended
over the street where a person
walks or a car drives.
Branches of a tree and grass
move when the wind blows.
* Peel off the
protection
seal from both
faces of the
area plate.
1
2
3
4
Limit line of
detection area
For near area
For far area
Power selector
switch
Use at “REDWALL”
position.
For near area
For far area
Power selector
switch
Use at “REDWALL”
position.
For all areas

- 5 -
ENGLISH FRANÇAIS DEUTSCH ITALIANO ESPAÑOL
5
[m]
2
0
[ft.]
0
10 413
0 10 20 30
0 10 20 30 40 50 60 70 80 90 100 110 120 130[ft.]
40 [m]
00 0 10 20 30
0 10 20 30 40 50 60 70 80 90 100 110 120 130[ft.]
40 [m]
[m]
2
[ft.]
10 413
DWN
UP
DWN
UP
Sens.Select.SW.Sens.Select.SW.
FUNCTION SETTING
Applicable
models
SIP-3020 SIP-4010 SIP-404 SIP-3020CAM DN
Sens.Select.SW.Sens.Select.SW.
Far areaFar area Near areaNear area
57307315730731
UP DWN
Cautions>>
If the red LED keeps blinking for approx. 60 seconds
after turning the power on, turn the power off and then on
again.
5-1
Sensitivity Selector Switch for
Near and Far Area
Applicable
models
SIP-3020 SIP-4010 SIP-404 SIP-3020CAM DN
You can change the sensitivity for far
area detection and near area detection
independently.
SELECTOR
POSITION FUNCTION
SH
Suitable for sites requiring a
level of sensitivity higher than
“H”
H
Suitable for sites requiring a
level of sensitivity higher than
“M”
M
(Factory
default)
Suitable for standard
applications
LSuitable for hostile and narrow
area
5-2
Detection Logic Selector Switch
Dip switch 1
Applicable
models
SIP-3020 SIP-4010 SIP-404 SIP-3020CAM DN
The near area sensor has two dual-element
devices, and it covers two types of plane areas
alternately using the two devices.
SELECTOR
POSITION STATUS
FUNCTION
UP
OR
Factory
default
A sensor signal is output when an
object is detected in either of the two
detection areas.
* Use this mode when you adjust
the detection area. Switch to AND
mode after you have finished the
detection area adjustment.
DWN AND
Use this mode to reduce instances
of incorrect detection of objects. The
sensor signal is output only when
an object is detected within the two
detection areas. If any objects are
blocking multiple detection areas,
use OR mode.
5-3
Detection Range Selector Switch
Dip switch 2
SELECTOR
POSITION STATUS
FUNCTION
UP OFF
Cancels the far area detection. The
detection area is reduced as shown
below.
DWN
ON
Factory
default
Enables the far area detection.
Applicable
models
SIP-3020 SIP-4010 SIP-404 SIP-3020CAM DN
Applicable
models
SIP-3020 SIP-4010 SIP-404 SIP-3020CAM DN
Cautions>>
If you cancel the far area detection, the detection
distance is limited to approximately 20 meters (65ft.). Be
sure to readjust and check the detection area using the
area viewfinder and the walk tester.
Cautions>>
When you are checking the detection area, take care not
to cover the shaded area of the window with the walk
tester or its cable. If infrared beams to the sensor are
partially shielded, the detection sensitivity will drop and
the detection operation may fail.
If it is difcult to detect an object>>
1. Set the detection logic switch to the “OR” position (see
Step 5-2).
If the sensor is OK when you have completed the walk
test, return the logic switch to the “AND” position.
2. Adjust the sensor sensitivity switch (see Step 5-1).
To mask the detection area>>
Detection
area How to mask the area Reference
Far area
3-5.hctiwsehtesU
Use the masking plate (mounted
in the main unit). Step 7
Near
area
Use the masking plate (mounted
in the main unit). 8-1
Attach the masking seal (an
accessory) to the area mirror
surface.
8-2
5-4
Alarm Interval Switch Dip switch 3-4
Applicable
models
SIP-3020 SIP-4010 SIP-404 SIP-3020CAM DN
You can set an interval (4 different times) to
suspend the alarm signal output.
For example, if you set this interval to 30
seconds, no more alarm signals will be output
for 30 seconds after the output of the first alarm
signal. If no pedestrians are detected for more
than 30 seconds, the system returns to the
standby mode.
Then, when a pedestrian is detected, the alarm
signal will be output.
SELECTOR
POSITION
FUNCTION
0 sec
(Factory
default)
15 sec 30 sec 60 sec
( )
( )
Near area sensitivity
selector switch
Far area sensitivity selector
switch
Walk tester
connector
Tamper
switch
Operation indicator
(See Step 11.) 1: Detection logic selector
(AND or OR)
2: Detection range selector
switch
3,4: Alarm holding time selectors
Far area detection is canceled.
Far area detection is canceled.
* UL-6: If movement occurs continuously during the time interval directly after the first
alarm, the time period for no alarms starts over.

- 6 -
10
[m]
15
5
0
5
10
15
[ft.]
30
20
10
0
10
20
30
40
50
50
40
[m]
2.3
0
[ft.]
0
7.6
0102030
0 10 20 30 40 50 60 70 80 90 100 110 120 130 [ft.]
40 [m]
10
[m]
5
0
5
10
[ft.]
30
20
10
0
10
20
00
30
0102030
0 10 20 30 40 50 60 70 80 90 100 110 120 130 [ft.]
40 [m]
[m]
2
[ft.]
10 413
10
[m]
5
0
5
10
[ft.]
30
20
10
0
10
20
30
[m]
2.3
0
[ft.]
0
7.6
0102030
0 10 20 30 40 50 60 70 80 90 100 110 120 130 [ft.]
40 [m]
[m]
5
0
5
[ft.]
10
0
10
00 0102030
0 10 20 30 40 50 60 70 80 90 100 110 120 130 [ft.]
40 [m]
[m]
2
[ft.]
10 413
[m]
5
0
5
[ft.]
10
0
10
[m]
2,3
0
[ft.]
0
7,6
0102030
0 10 20 30 40 50 60 70 80 90 100 110 120 130 [ft.]
40 [m]
10
[m]
15
5
0
5
10
15
[ft.]
30
20
10
0
10
20
[m]
2
0
[ft.]
0
10 413
30
40
50
50
40
0102030
0 10 20 30 40 50 60 70 80 90 100 110 120 130 [ft.]
40 [m]
TOP VIEW (Installation height 2.3 m (7.6ft.))
TOP VIEW (Installation height 4.0 m (13ft.))
SIDE VIEW (Installation height 2.3 m (7.6ft.)) : Near area : Far area
TOP VIEW (Installation height 4.0 m (13ft.))
SIDE VIEW (Installation height 4.0 m (13ft.)) : Near area : Far area
TOP VIEW (Installation height 2.3 m (7.6ft.))
SIDE VIEW (Installation height 2.3 m (7.6ft.)) : Near area : Far area
SIDE VIEW (Installation height 4.0 m (13ft.)) : Near area : Far area
TOP VIEW (Installation height 2.3 m (7.6ft.))
SIDE VIEW (Installation height 2.3 m (7.6ft.)) : Near area : Far area
DETECTION AREA
6
Applicable
models
SIP-3020 SIP-4010 SIP-404 SIP-3020CAM DN
TOP VIEW (Installation height 4.0 m (13ft.))
SIDE VIEW (Installation height 4.0 m (13ft.)) : Near area : Far area
Applicable
models
SIP-3020 SIP-4010 SIP-404 SIP-3020CAM DN
Applicable
models
SIP-3020 SIP-4010 SIP-404 SIP-3020CAM DN

- 7 -
ENGLISH FRANÇAIS DEUTSCH ITALIANO ESPAÑOL
10
[m]
15
5
0
5
10
15
[ft.]
30
20
10
0
10
20
[m]
2
0
[ft.]
0
10 413
30
40
50
50
40
0102030
0 10 20 30 40 50 60 70 80 90 100 110 120 130 [ft.]
40 [m]
[m]
2.3
0
[ft.]
0
7.6
10
[m]
15
5
0
5
10
15
[ft.]
30
20
10
0
10
20
30
40
50
50
40
0102030
0 10 20 30 40 50 60 70 80 90 100 110 120 130 [ft.]
40 [m]
TOP VIEW (Installation height 4.0 m (13ft.))
SIDE VIEW (Installation height 4.0 m (13ft.)) : Near area : Far area
TOP VIEW (Installation height 2.3 m (7.6ft.))
SIDE VIEW (Installation height 2.3 m (7.6ft.)) : Near area : Far area
Masking the Far Area Sensor
The far area mirror mounted in the main unit has 2 far masking
plates; one at the right side of this mirror and the other at the left
side of this mirror. You can mask the detection area by changing
the position of these masking plates.
Cautions>>
You can only mask the detection area from its outside to
its inside using the masking plates. You cannot mask only
the inside detection area.
However, if you need to mask the inside detection area
only, use the white space (margin) of the near area
masking seal (an accessory) for the masking. Attach the
seal and mask all mirrors that you need to shield.
Cautions>>
The window is linked to the main unit by nylon wire loop
so that the window does not fall. Do not pull the window
using excessive force.
After you have masked the detection areas, mount the
window and place the excessive nylon wire loop inside
the main unit.
How to remove the window>>
Applicable
models
SIP-3020 SIP-4010 SIP-404 SIP-3020CAM DN
34 12567
10 [m]155051015
[ft.]302010 0 102030405050 40
7
6
5
1
4
23
•
•
•
•
7
Applicable
models
SIP-3020 SIP-4010 SIP-404 SIP-3020CAM DN
Window
Press the left bottom hole with your
nger, and pull the window up.
2Attach the masking plate to the mirror,
and secure it to the ribs.
3Insert the xing rubber form to secure
the knob of the masking plate.
1Remove the masking plate from
the storage, and check the
detection area and the mirror you
use by referring to the area chart.
Far area mirror
Rib
Rib
If tree branches or other moving objects
are in the path of the detection beam.
Angle of camera view: Approx.
60° (Factory default)
Angle of camera view: Approx.
60° (Factory default)

- 8 -
8
8-1
Masking the Detection Areas using
Masking Plates
The near area mirror mounted in the main unit has 2 near
masking plates; one at the right side of this mirror and another
at the left side of this mirror. You can mask the detection area
by changing the position of these masking plates.
Cautions>>
You can mask the outside detection areas only; they are
areas 1 and 6. Use the area masking seals (an accessory)
to mask the other detection areas (see Step 8-2).
Applicable
models
SIP-3020 SIP-4010 SIP-404 SIP-3020CAM DN
6 4 2 5 3 1
10 [m]155051015
[ft.]30 20 10 0 10 20 30 40 5050 40
6
5
4
3
1
2
MASKING THE NEAR AREA SENSOR
Applicable
models
SIP-3020 SIP-4010 SIP-404 SIP-3020CAM DN
1234
[m]505
[ft.]10 0 10
[m]505
[ft.]10010
432 3
2
1
SIP-4010 SIP-404
Far area mirror
Rib
Rib
Rib
Near area mirror
2Attach the masking plate to the mirror,
and secure it to the ribs.
3Insert the xing rubber form to secure
the knob of the masking plate.
1Remove the masking plate from the
storage, and check the detection
area and the mirror you use by
referring to the area chart.
2Attach the masking plate to the mirror, and
secure it to the ribs.
3Insert the xing rubber form to secure the
knob of the masking plate.
1Remove the masking plate
from the storage, and
check the detection area
and the mirror you use by
referring to the area chart.
Rib
If tree branches or other moving objects
are in the path of the detection beam.
If tree branches or other moving objects
are in the path of the detection beam.

- 9 -
ENGLISH FRANÇAIS DEUTSCH ITALIANO ESPAÑOL
9-1
Adjustment of Camera
Applicable
models
SIP-3020 SIP-4010 SIP-404 SIP-3020CAM DN
Open the camera cover, and connect the monitor unit cable
to the camera unit.
Adjust the vertical angle and the angle of view of the
camera.
Cautions>>
The vertical camera angle adjustment mechanism is
separated from the detection area control mechanism.
To satisfy the BS8418 Standard, make sure that the
vertical angle and the angle of view of the camera match
the detection area correctly.
Close the camera cover, and tighten two fixing screws.
Check the image viewed by the camera, using the monitor
unit or another monitoring device.
ADJUSTMENT OF CAMERA
9
(1)
(2)
(3)
(4)
8-2
Masking the Detection Areas using
Masking Seals
Using the tweezers (an accessory), carefully attach the area
masking seals (an accessory) to the near area mirror.
F 6
E 6
F
E
D
C
B
EEEEEE
DDDDDD
CCCCCC
BBBBBB
FFF
FFF
642 53 1
642 53 1
642 53 1
642 53 1
642 53 1
135246
[m]10 1515
5050 40
50510
[ft.]
30 20 10 0 10 20 30 40
[m]
4
2
0
t
.]
3
0
0
010 20 30
010 20 30 40 50 60 70 80 90 100 [ft.]
[m]
6
35
2
1
4
B
C
D
E
F
BCDEF
Points>>
If you are using the SIP-3020, SIP-4010, or SIP-404
sensor unit when you have completed Step 8, proceed to
Step 9-2.
2Open the
camera
cover.
1Loosen the xing
screws.
3Connect the
monitor unit
cable to the BNC
terminal of camera
unit.
1Loosen the focal length
screw, and adjust the angle
of view.
2Loosen the focus screw, and
adjust the focus.
3Adjust the angle by rotating
the vertical angle adjustment
screw.
4When you have completed these adjustments,
tighten screws 1and 2.
Near area mirror
Caution>>
Remove the
transportation
protection ardboard(s).
Caution>>
Peel off the protection
seal(s) off the window.
Area masking seals
MIRROR

- 10 -
10-1
If There is a Public Street Where a People
Walk or Cars Drive by the Detection Area
Points>>
Reduce the size of the detection area so that it does not
include any public streets.
Check to see that the arrow of the main unit is within the
width of “Angle adjustment guide” on the adjustment screw.
Using the area viewfinder, check to see that the detection
area does not include any public streets.
If the detection area does go beyond a public street,
correct the vertical angle of the main unit.
However, exercise care so that the arrow does not move
away significantly from the “Angle adjustment guide”
position.
If the arrow does move away signicantly from
the “Angle adjustment guide” position:
Mask the far area detection area using the masking plate
or by using the far area masking switch. You may be
required to also mask the near area detection area under
specific sensor installation conditions (see Steps 5 and 8).
When a person walks along the street or a car drives along
it, check the detection area using the walk tester.
Points>>
You cannot mount and use both the area viewfinder and
walk tester simultaneously.
Cautions>>
The detection area may increase if there is a large
difference in temperature between the moving object and
the background.
Cautions>>
A heat source beyond the detection area may cause a
false alarm due to the reflection of heat off the ground.
Examples of types of surfaces that reflect include water
(puddles), wet roads, smooth concrete surfaces and
asphalt roads.
If the source of the heat is strong and/or the reflection
rate is high, the detection distance will be longer than
required and may detect unnecessary objects beyond the
target area. Therefore, select the detection range position
according to the ground conditions of the installation site.
OPERATION TEST
10
(1)
(2)
(3)
(4)
9-2
Termination Procedure
Applicable
models
SIP-3020 SIP-4010 SIP-404 SIP-3020CAM DN
After you have adjusted all sensor items, securely tighten all
adjustment screws that you have loosened. Finally, securely
tighten the bottom fixing screws.
Cautions>>
If you need to adjust the detection area again, be sure
to loosen the xing screw. If you try to move the main
unit without loosening the xing screw, the unit may be
damaged.
When you mount the cover, place the excessive nylon
wire loop in the main unit. If the wire has been pinched
by the window and the cover, rain drops may be able to
enter into the main unit.
Mount the cover.
•
•
(1)
(2)
1Adjustment screw
2Fixing screw

- 11 -
ENGLISH FRANÇAIS DEUTSCH ITALIANO ESPAÑOL
SPECIFICATIONS
12
LED FUNCTIONS
Far areaFar area
DETECTOR STATUS If the cover is removed
During power ON Blinks.
During standby Turns OFF.
When detected (in far/near area) Lights.
11
10-2
If Tree Branches or Grass are Detected
When They Move Within the Detection Area
Points>>
Adjust the detection area so that it does not cover tree
branches or grass that move when the wind blows.
Check to see that the arrow of the main unit is within the
width of “Angle adjustment guide” on the adjustment screw.
Using the area viewfinder, check to see that the detection
area does not cover tree branches or grass that may move
when the wind blows.
Use the walk tester to listen for sound level changes when
there is no apparent activity in the detection area.
Adjust the detection area so that it does not detect
unwanted areas.
If the sound level changes, some part of the detection area
must be active (i.e.: an object is moving).
Use the walk tester and locate the part of the detection area
that is active. Change the walk tester selector switch
position and determine whether the active part of the
detection area is far or near.
Using the area viewfinder again, locate the active detection
area.
Mask the active detection area. To do this, mask the area
using the masking plate or the masking seal. Otherwise
mask the area using the far area masking switch (see Steps
5, 7, and 8).
Using the walk tester again, check that the sound level
changes. If the sound level does not change excessively,
you can finish the adjustment.
Points>>
You cannot mount and use both the area viewfinder and
the walk tester simultaneously.
(1)
(2)
(3)
(4)
(5)
(6)
(7)
12-1
Specifications of the Main Unit
Applicable
models
SIP-3020 SIP-4010 SIP-404 SIP-3020CAM DN
Model SIP-3020 SIP-4010 SIP-404 SIP-3020
CAM DN
Detection method Passive infrared
Coverage
30 x 20m
(100 x 65ft.)
40 x 10m
(130 x 33ft.)
40 x 4m
(130 x 13ft.)
30 x 20m
(100 x 65ft.)
Number of detection
zones 74 zones 48 zones 24 zones 74 zones
Mounting height 2.3 to 4m (7.6 to 13ft.)
Power input 11 - 26V DC
22 - 26V AC 12V DC
With optional
heating unit 22 - 26V DC/AC
Can not use
SIP-HU
Current draw 40mA max. (12V DC)
75mA max. (24V AC)
180mA max.
(12V DC)
With optional
heating unit 415mA max. (24V AC)
—
Operation indicator RED ALARM
Warm-up period Approx. 60 sec.
Detection range
selector Far area: ON / OFF
Alarm interval period
0 / 15 / 30 / 60 sec.
Detection logic
selector AND/OR
Tamper output N.C. 28V DC, 0.1A max.
Trouble output N.C. 28V DC, 0.2A max.
Alarm output N.C.28V DC, 0.2A max.
N.O.28V DC, 0.2A max.
Sensitivity selector Far: SH/H/M/L Near: SH/H/M/L
Operating temperature
-25 to +60°C, -40 to +60°C
(-13 to +140°F, -40 to +140°F)
with optional heating unit
IP rating Main unit : IP65
Chassis : IP55
Dimensions
(H × W × D)
227 x 102 x 266mm
(9.0 x 4.0 x 10.5 in.)
252 x 102
x 317 mm
(9.9 x 4.0
x 12.5 in.)
Weight 1.2kg (42 oz.)
1.5kg (52 oz.)
Accessories
2 Screws
2 Nylon anchors
1 Paper template
1 Allen key
1 Area masking seal
1 Tweezers
1 Instruction manual
1 Area plate
1 Fixing rubber form
Cautions>>
If the red LED keeps blinking for
approx. 60 seconds after turning
the power on, turn the power off
and then on again.
Operation indicator - Red LED
* UL-7
* UL-8
* UL-8
* UL-8
* UL-8
* UL-9
* UL-9
* UL-9
* UL-8
* UL-7; not listed by UL
* UL-8; not evaluated by UL
* UL-9; all relay outputs are resistive load only

- 12 -
12-2
Camera Specifications
Applicable
models
SIP-3020 SIP-4010 SIP-404 SIP-3020CAM DN
Model
SIP-3020CAM DN (EU) SIP-3020CAM DN (US)
Image sensor 1/3" CCD (PAL) 1/3" CCD (NTSC)
TV line 480TVL (at wide position)
Resolution PAL
752 H x 582 V
NTSC
768 H x 494 V
Lens
f = 3 to 9mm, varifocal, DC auto iris lens F1.2
Minimum illumination Day (colour): 0.5 lx (F1.2)
Night (B/W): 0.03 lx (F1.2)
Video output
1.0Vp-p/75
/BNC connector, PAL
1.0Vp-p/75 /BNC
connector, NTSC
DIP switch
No.
NAME Function Factory default
setting
1 ELC/ALC Exposure control
method setting
OFF (ALC)
2 AGC Automatic sensitivity
setting
ON
3 BLC Backlight correction ON
4 * Leave this switch OFF (factory default).
DIMENSION
SIP-3020/4010/404
227
(9.0)
102
(4.0)
266
(10.5)
90
(3.6)
21
(0.83)
75
(3.0)
116
(4.57)
17.1
(0.67)
13
(0.51)
96
(3.78)
21
(0.83)
OPTION
OPM-WT, AWT-3 -Audio Walk Tester
AVF-1 -Area View Finder
SIP-MINIHOOD -Sun/Snow shield
SIP-HU -Heating unit
Cautions>>
When SIP-HU is used, the power for SIP unit should be
22 - 26V DC/AC.
SIP-3020CAM DN can not use SIP-HU.
These units are designed to detect movement to activate CCTV
system. Being only part of a complete surveillance system,
we cannot accept responsibility for any damage or other
consequences resulting form the activation of the unit.
Specifications and design are subject to change without prior
notice.
•
•
•
•
SIP-3020CAM
102
(4.0)
96
(3.78)
21
(0.83) 21
(0.83)
90
(3.6)
317
(12.5)
216
(8.5)
252
(9.9)
75
(3.0)
116
(4.57)
17.1
(0.67)
13
(0.51)
Close.
Open.
Iris
Unit:mm (inch)
Unit:mm (inch)
■EU contact information
Manufacturer:
OPTEX CO., LTD.
5-8-12 Ogoto, Otsu, Shiga, 520-0101 JAPAN
Authorised representative in Europe:
OPTEX (EUROPE) LTD. / EMEA HEADQUARTERS
Marandaz House 1 Cordwallis Park, Clivemont Road,
Maidenhead, Berkshire, SL6 7BU U.K.
OPTEX CO., LTD. (JAPAN)
URL: http://www.optex.net
OPTEX INC. (U.S.)
URL: http://www.optexamerica.com
OPTEX DO BRASIL LTDA. (Brazil)
URL: http://www.optex.net/br/es/sec
OPTEX (EUROPE) LTD.
/ EMEA HQ (U.K.)
URL: http://www.optex-europe.com
OPTEX TECHNOLOGIES B.V.
(The Netherlands)
URL: http://www.optex.eu
OPTEX SECURITY SAS (France)
URL: http://www.optex-security.com
OPTEX SECURITY Sp.z o.o. (Poland)
URL: http://www.optex.com.pl
OPTEX (DONGGUAN) CO.,LTD.
SHANGHAI OFFICE (China)
URL: http://www.optexchina.com
Copyright (C) 2017 OPTEX CO.,LTD.
OPTEX KOREA CO.,LTD. (Korea)
URL: http://www.optexkorea.com
OPTEX (Thailand) CO., LTD. (Thailand)
URL: http://www.optex.net/th/th
OPTEX PINNACLE INDIA, PVT., LTD.
(India)
URL: http://www.optex.net/in/en/sec
* UL-10; All option equipment are not evaluated by UL.
Other manuals for V Series
2
This manual suits for next models
6
Table of contents
Other Redwall Security Sensor manuals
Popular Security Sensor manuals by other brands

Omron
Omron MS2800 Brochure & specs

Sonoff
Sonoff SNZB-04P user manual

Guardian Fall Protection
Guardian Fall Protection Edge Harness Series instruction manual

DMP Electronics
DMP Electronics 1125 Installation sheet

ABLE
ABLE Ultima OPIR-5 Installation & maintenance instructions

Falltech
Falltech SteelGrip Temporary Cable Horizontal... User instruction manual