4| Regency Horizon® HZO42 Gas Fireplace
|
4safety decal
This is a copy of the label that accompanies each HZO42 Outdoor Fireplace. We have printed a copy of the contents here for your review.
NOTE: Regency® units are constantly being improved. Check the label on the unit and if there is a difference, the label on the unit is the correct one.
COPY OF SAFETY DECAL For the State of Massachusetts, installation and
repair must be done by a plumber or gas fitter
licensed in the Commonwealth of Massachusetts.
For the State of Massachusetts, flexible connec-
tors shall not exceed 36 inches in length.
For the State of Massachusetts, the appliances
individual manual shut-off must be a t-handle
type valve.
Part #: 920-250
Colour: Black on grey except what is indicated as being printed red.
Size: (File at 100%)
Note to Printer: Continue with first serial # number being 554000001.
Continuation from old serial # decal 918-888. Do not start at 0
March 27/20: Created draft for approval - Do not print
May 27/20: Updated with Intertek blurb
Jan 07/21: Updated part number
DO NOT REMOVE THIS LABEL / NE PAS ENLEVER CETTE ÉTIQUETTE
554
554
FPI Fireplace Products International Ltd.
6988 Venture St.
Delta, BC, Canada V4G 1H4
Minimum Clearances to Combustibles /
Dégagements min. aux matériaux combustibles
Serial No./ No de série
.
NOT FOR USE WITH SOLID FUELS. /
NE PAS UTILISER AVEC DES COMBUSTIBLES SOLIDES Made in Canada/ Fabriqué au Canada
Duplicate S/N
APPAREIL FONCTIONNANT AU PROPANE
Modèle HZO42-LP11
PROPANE: Model HZO42-LP11
NATURAL GAS: Model HZO42-NG11
Maximum supply pressure
Minimum supply pressure
Manifold pressure high
Orifice size
Maximum input
Altitude
Pression d'alimentation maximale
Pression d'allimentation minimum
Pression manifold lev eé é
Taille de l'orifice
D bit calorifique maximal seloné
l'altitude
14” WC/C.E. (3.49 kPa)
5" WC/C.E. (1.25 kPa)
3.5" WC/C.E. (0.87 kPa)
# 29 DMS
44,500 Btu/h (13.04 kW)
0-4500 ft/pi (0-1372 m)
Pression d'alimentation maximale
Pression d'alimentation minimale
Pression manifold lev eé é
Taille de l'orifice
D bit calorifique maximal seloné
l'altitude
14" WC/C.E. (3.49 kPa)
11” WC/C.E. (2.74 kPa)
10" WC/C.E. (2.49 kPa)
# 47 DMS
43,500 Btu/h (12.74 kW)
0-4500 ft/pi (0-1372 m)
Maximum supply pressure
Minimum supply pressure
Manifold pressure high
Orifice size
Maximum input
Altitude
D
E
F
A
B
C
Side Walls / Parois latérales
A 11” (279mm)
Ceiling / Plafond
B 36” (914mm)
Min. Mantel Height/Hteur min. manteau
C 18”(457mm)
Max. Mantel Depth/Prof. max. manteau
D 12” (305mm)
Alcove Width/Largeur alcôve
E 57" (1448mm)
Alcove Depth/Prof. alcôve
F 36" (914mm)
The installation must conform with local codes or, in the absence of local codes, with CAN/CSA-B149.1, Natural Gas and Propane Installation Code or ANSI Z223.1/NFPA 54. The appliance, when installed, must be electrically grounded in accordance with local codes or, in the absence of
local codes, with the Canadian Electrical Code, CSA C22.1 or with the National Electrical Code, ANSI/NFPA 70. This appliance is only for use with the type of gas indicated on the rating plate . See owner's manual for details.
L'installation doit être conforme aux codes locaux ou, en l'absence de tels codes, à la norme CAN/CSA-B149.1, gaz naturel et propane ou au Code d'installation ANSI Z223.1/NFPA 54. L'appareil, une fois installé, doit être raccordé électriquement à la terre conformément aux codes locaux ou, en
l'absence de tels codes, au Code canadien d'électricité, CSA C22.1 ou au National Electrical Code, ANSI / NFPA 70.
Cet appareil est à utiliser uniquement avec le type de gaz indiqué sur la plaque signalétique. Voir le manuel d’installation pour plus de détails.
Electrical supply/Alimentation électrique : 6VDC or 115V 60Hz less than/inférieur à 1A
APPAREIL FONCTIONNANT AU GAZ NATUREL
Modèle HZO42-NG11
FOR OUTDOOR USE ONLY / POUR UTILISATION À L’EXTÉRIEUR SEULEMENT
IF STORED INDOORS, DETACH AND LEAVE CYLINDER OUTDOORS / SI STOCKÉ À L’EXTÉRIEUR, DÉTACHER LA BOUTEILLE ET LA LAISSER À L’EXTÉRIEUR 920-250
Minimum ambient air temperature in which appliance may be operated: 32ºF (OºC).
Ne pas faire fonctionner l'appareil si la température ambiante est inférieure à: 32ºF (OºC).
HZO42-LP11
HZO42-NG11
Listed: OUTDOOR DECORATIVE GAS APPLIANCE / FOYER EXTÉRIEUR AU GAZ D’AGRÉMENT
Certified to/Certifié : ANSI Z21.97-2017 - CSA 2.41-2017/CSA 2.17-2017
Refer to lntertek's Directory of Building Products for detailed information.
Pour plus de details, se reporter au Repertoire des produits de construction de lntertek.
C# 4001172
For Use Only with Barrier (Part # 940-533/P each - 2 required)
o
Utiliser uniquement avec l’écran (n 940-533/P chaque - 2 requis)
HZO42 DECAL LOCATION
1) Remove stainless steel 4-sided surround (not shown).
2) Remove both barrier glass. See below.
2 x Barrier Glass
3) Remove ¾'' (19 mm) stainless steel trim. See below.
Remove 3/4'' (19 mm) trim
4) Lift up on the stainless-steel burner tray cover in front so the lighting plate and serial #
decal may be pulled out.
Stainless Steel Burner Tray
5) Reverse steps to put back into place.