3.OD.3D
Air Ventilation Through Chimney Chase Air Ventilation Through Top Flashing
Drawings Not To Scale
chimnEy chAsE Air vEntilAtiOn
Fig. 5 Fig. 6
50 25
25
120mm
minimum
Drip
Line
Spigot flashing to suit
flue pipe casing
Non combustible material
Hebel Block or 12mm
Promina board or similar
under the flashing
120mm
minimum
Oversized casing cover
is necessary
Drip
Line
Air
Vent
NOTE: Air Vents to be min 2 x 80mm diam. or equal square or rectangle shape
area. These must be bird & rodent proofed with permanently fixed screens.
1. Install rst length of ue pipe crimped end down, inside gather collar. Rivet ue pipe in 3 places around
gather collar. Place bottom ue spider bracket around gather ue pipe collar, secure in position by
tightening up coach bolt/screw (supplied).
2. Install second length of the ue pipe crimped end down and x by riveting in at least 3 places around the
ue pipe joint.
3. Install rst length of the ue pipe casing by positioning on installed bottom ue spider bracket crimped
end up.
4. Position ue spacer at the ue pipe joint.
5. Repeat steps 1 - 4 to the required ue system height of 3.6m.
6. The last length of ue pipe needs to extend past the ue pipe casing by at least 150mm or ush with the
top of the casing cover spigot when tted - sizing/measuring and cutting down should be carried out prior
to the ue pipe casing being tted over the ue pipe.
6. Before tting casing cover, place the spider in opposition with the spider post facing down between the
ue pipe and ue pipe casing. Secure spider in position. Place the casing cover over the ue pipe, press
down rmly onto the spider. Check airway around the casing cover is clear, then secure in position using
three stainless steel rivets.
7. Fit cowl to top of ue - DO NOT RIVET IN POSITION. In high wind areas, it is recommended that the cowl
be secured in position with a stainless steel self tapping screw, this will enable the cowl to be removed for
cleaning. Discuss Bird Proong needs with your installer. N.B. in extreme wind areas it may be necessary
to consult The Fireplace Ltd or your local agent for further technical assistance Ph: 0800 843 347.
8. If ue is concealed in a chase, allow for air vents (2 x 80mm diam. or equivalent) at the highest possible
point on the chimney chase or alternatively, allow a min 25mm air space between the casing cover spigot
and the outer casing. Refer to Figure 5 & 6.
fluE instAllAtiOn
GEnErAl mAintEnAncE
▪ When the fire is not in use, ensure the stainless steel cover is fitted at all times. This will assist in protecting the
firebox. DO NOT attach the cover when the fire is in use.
▪This fire is NOT warranted against rust. Please refer to our full Warranty Card for full details.
▪ A seasonal touch-up is recommended. Simply remove surface rust with some steel wool and repaint using Black VHT
paint (available from your nearest showroom). Please ensure all areas around the firebox are protected when re-painting.