
U37 Regency ULTIMATE Rear Vent Direct Vent Freestanding Gas Heater 5
IMPORTANT:
SAVE THESE
INSTRUCTIONS
The ULTIMATE Rear Vent Direct Vent Free-
standingGasStovemustbeinstalledinaccord-
ancewiththeseinstructions.Carefullyreadall
theinstructionsinthismanualfirst.Consultthe
building authority having jurisdiction to deter-
mine the need for a permit prior to starting the
installation.
Note: Failure to follow the instructions
could cause a malfunction of the
heaterwhichcouldresultindeath,
seriousbodilyinjury,and/orprop-
ertydamage.Failuretofollowthese
instructions may also void your
fire insurance and/or warranty.
SPECIFICATIONS
Fuels: U37-NG is approved for use with
natural gas.
U37-LP is approved for use with
liquefiedpetroleumgases(propane).
Electrical:120 V A.C. system.
Circulation Fan: Variable speed, 125/75.
Log Sets: Ceramic fibre, 7 per set.
Vent System:
Axial (6-5/8" outer / 4" inner liner)
rigid flue and Riser Vent Terminal.
BEFORE YOU START
Safeinstallationandoperationofthisappliance
requires common sense, however, we are
required by the Canadian Safety Standards
andANSIStandardstomakeyouawareofthe
following:
INSTALLATION
4) Werecommendthatyouplanyourinstalla-
tion on paper using exact measurements
forclearances andfloor protectionbefore
actually installing this appliance. Have a
qualified building inspector review your
plans before installation.
GENERAL SAFETY
INFORMATION
1) The appliance installation must conform
with local Canadian Electrical Code.
2) Theappliancewheninstalled,mustbeelec-
trically grounded in accordance with local
codes,orintheabsenceoflocalcodeswith
the current National Electrical Code, ANSI/
NFPA70orCSAC22.1CanadianElectrical
Code.
3) The appliance should be inspected for
shippingdamagebeforeuseandserviced
annuallybyaprofessionalserviceper-
son. More frequent cleaning may be re-
quiredduetoexcessivelintfromcarpeting,
bedding material, etc. It is imperative that
control compartments, and circulating air
passageways of the appliance be kept
clean and free from excessive lint from
carpeting.
4) See general construction and assembly
instructions.Theapplianceandventshould
be enclosed when installed in or passing
through a living area, where children may
come in contact with it.
5) This appliance must be connected to the
specified vent and termination cap to the
outsideofthebuildingenvelope.Nevervent
to another room or inside a building. Make
surethattheventisfittedaspertheinstruc-
tions starting on page 6.
6) Inspect the venting system annually for
blockage and any signs of deterioration.
7) Ventingterminalsshallnotberecessedinto
a wall or siding.
8) Any safety glass removed for servicing
must be replaced prior to operating the
appliance.
9) Topreventinjury,donotallowanyonewho
is unfamiliar with the operation to use the
fireplace.
1) Provide adequate clearances for servic-
ing, proper operation and around the air
openings into the combustion chamber.
2) The appliance must be installed on a flat,
solid,continuoussurface(e.g.wood,met-
al,concrete).Thismaybethefloor,oritcan
be raised up on a platform to enhance its
visual impact. The appliance may be in-
stalled on carpeting, tile, wood flooring or
other combustible material, because the
appliance's metal pedestal base extends
the full width and depth of the appliance.
TheULTIMATERearVentDirectVentFree-
standing Gas Stove can be installed in a
widevarietyofwaysandwillfitnearlyany
room layout. It may be installed in a re-
cessed position, framed out into the room,
or across a corner.
3) TheULTIMATERearVentDirectVentFree-
standingGasStoveisapprovedformanu-
facturedhomeinstallations,seepages6to
9 for the required vent arrangements. If
installedintoamanufacturedhometheunit
must be bolted down to the floor.
Emissions from burning wood or gas could
contain chemicals known to the State of
California to cause cancer, birth defects or
other reproductive harm.
DUE TO HIGH TEMPERATURES,
THE APPLIANCE SHOULD BE LO-
CATED OUT OF TRAFFIC AND
AWAY FROM FURNITURE AND
DRAPERIES.
WARNING: FAILURE TO INSTALL
THIS APPLIANCE CORRECTLY
WILLVOIDYOURWARRANTYAND
MAY CAUSE A SERIOUS HOUSE
FIRE.
CHILDREN AND ADULTS SHOULD
BE ALERTED TO THE HAZARDS OF
HIGH SURFACE TEMPERATURES,
ESPECIALLY THE FIREPLACE
GLASS,ANDSHOULDSTAYAWAY
TO AVOID BURNS OR CLOTHING
IGNITION.
YOUNG CHILDREN SHOULD BE
CAREFULLY SUPERVISED WHEN
THEY ARE IN THE SAME ROOM AS
THE APPLIANCE.
CLOTHING OR OTHER FLAMMA-
BLE MATERIAL SHOULD NOT BE
PLACED ON OR NEAR THE APPLI-
ANCE.
INSTALLATION AND REPAIRS
SHOULD BE DONE BY A QUALI-
FIED SERVICE PERSON. THIS AP-
PLIANCESHOULDBEINSTALLED,
REPAIRED, INSPECTED BEFORE
USE AND AT LEAST ANNUALLY
BY A QUALIFIED SERVICE PER-
SON. MORE FREQUENT CLEAN-
ING MAY BE REQUIRED DUE TO
EXCESSIVE LINT FROM CARPET-
ING,ETC. ITISIMPERATIVETHAT
THE CONTROL COMPARTMENT,
BURNERS AND CIRCULATING AIR
PASSAGEWAYS OF THE APPLI-
ANCE BE KEPT CLEAN.