Regul' Electronique Bulleur Instruction Manual

DESIGNED AND MANUFACTURED IN FRANCE SINCE 1989
16012019
INSTRUCTIONS
INSTALLING
Peace of mind
Bulleur
Water level regulation for overflow
pools
Bulleur

Precautions of use
Security
Returning
- Make sure that 240V 50 Hz the supply
voltage does not exceed 240VAC-
50Hz.
- If liquid or any object enters the control
box, unplug the unit and have it
checked by a qualified technician
before returning it o service.
- Prohibition of drilling the control box
The filtration cabinet must be in the
vicinity of the device and be easy to
access.
After switching off the appliance with
the ON/OFF switch, do not open the
appliance until the lights have
completely extinguished.
Do not store chemical cans near the
appliance.
- Retain the original packing carton
and packing material. They will be
very useful if you ever need to ship the
unit.
- To ensure maximum protection,
repack the unit as it was factory
packaged.
- The Bulleur is an electronic device and must
not be exposed to rain or moisture.
- The technical room must be properly
ventilated.
- The power supply must be protected
upstream by a 30 mA differential circuit-
breaker.
- In order to avoid any risk of electric shock,
open the cabinet only for its installation or a
service intervention (to change an electronic
card) after having cut off the power supply.
Advice
R e g u l ' e l e c t r o n i q u e
designs and manufactures in
its workshops, in France, all
i t s p r o d u c t s o f s a l t
electrolyse, pH regulation and
regulation of water level.
Warranty
- You have just purchased a Regul'
Electronique, we thank you for
your confidence.
- Unless otherwise specified ,the
warranty period for our products is
3 years from the date of your
invoice.
- Excluded from the warranty are any so-called
wear parts(fuses,batteries,seals,air tube,
valves, pump membranes, etc).
- This guarantee is limited to the supplies of
our company. It consists in the repair, by our
care, and in our workshops, defects or
manufacture and matter, that the customer
must prove.
- The equipment must be returned free of
postage. The costs of removal, rest and
transport are excluded from the guarantee.
- In all cases, our responsability is limited to
the replacement of the defective parts, without
any compensation or damage and interest can
be claimed for any damage caused(physical
etc..).
- The guarantee ceases when our materials
are modified outside our workshops.
- The warranty does not apply to replacements
or repairs that result from normal wear and
tear of equipment, damage or accidents
resulting from negligence, faulty monitoring or
maintenance, improper installation or use
abnormal devices.
- In the case of inadequate treatments and
adjustments we cannot be held liable, in
particular in the case of corrosion and defects
due to excessively high operating stresses or
if the equipment must therefore be operated at
high speeds too sustained.
2

3
Régul’ Electronique
Checks to be carried out before the appliance is switched on
Verification before start-up
- Before starting, it is imperative that you have read all the information
contained in this manual. The records, like the devices, evolve.
Thus the revisions described in the manuals will enable you to know the
perfect functioning and the modifications made.
- The Bulleur must be started when the pool is full and the buffer tank is
at the ideal level.
Technical characteristics
The Bulleur has :
- A senser allowing to measure a heigh of water of 2,50 m
- A measuring rod made up of 3 PVC tubes,20 mm in diameter and 42 cm in length
- If necessary, the measuring rod can be extended by a PVC tube with a diameter of
20mm.
- An intermittent 240 V membrane compressor
- An electronic board protected by a 200 mA fuse
- A 315 mA fuse protection of the solenoid control transformer.
- A led flashes to indicate that it is faulty, preventing the malfunction of the solenoid
valve.
- The 240V- 6 A drain relay is designed to operate a contactor coil and not the direct
control of a power motor.
Fuse 315mA solenoid valve
Led fuse solenoid valve
Contact 6A 240V~
for drain pump contactor
Fuse 500mA alimentation
Fuse 3.15A
Forced filtration
Stop filtration

4

Precautions of use
2
Warranty
3
Checks and Characteristics
4
Conditioning
6
Location of Controls
7
Table of contents
5
Régul’ Electronique
1 - Installing the device
Bindings
8
Device connections
9
2 - Bulleur installing
Hydraulic installation
10
3 - Configuration Menu
Configuration
11
4 - Calibration of thresholds
Schematic diagram
12
Functionality of each threshold
13
Calibration of levels
14
6 - Additional displays
Additional displays
15
The Configuration menu is used to select the active functions of the Bulleur
Le Calibration menu makes it possible to choose the water levels for each threshold
Normal displays and indications of anomalies

Conditioning
Check the package to make sure it contains the following items :
6
- The control box and its operating instructions
- 1 x cap for measuring rod
- 2 x sleeves of 20 mm to stick
- 3 x tubes of measuring rods
(PVC of 20 mm to stick –length 420 mm)
- 2 x PVC clips and 2x stainless steel screws
(fixation of the measuring rod in the buffer tank)
- 25 m bubble tube 4/6 mm
- 1 x RAINBIRD DV 100 solenoid valve
- 4 x screws and fixing pins of the control box

Location of operating controls
7
Régul’ Electronique
The Bulleur box
On/Off switch
Diagramm pump
Configuration Calibration
STOP
The Bulleur screen
setup menu
level display (in buffer tank)
information line
state of the water level
in the buffer tank with display
of the thresholds reached
Operating/controls button
clic
clic 2"
A 2 sec click to modify
a data item
A short click to validate
click
A click to enter
the configuration menu (p11) +
to decrease or increase
a value
The control knob allows by pressing to change the displayed value ,to enter certain menus and by
rotating to modify a stored value
Off On
to validate a function
N1 à x cm
to choose a value
-
Solenoid valve Power supply terminal block
Force filtration
Pressure sensor
Stop filtration
Drain pump
Click
Turn
+
-

Fixing
R eminder
The assemly must be secured from any water spray and in a properly
ventilated room.
The box has a dimension of 255 x 180 mm.
In order to maintain the performance and reliability of he assembly, provide the necessary space
between it and the nearest devices and obstacles.
The Bulleur is supplied with a mounting template to facilitate the installation- 4 fixing holes make
it possible to assemble the assembly.
Mark the location of the holes , using a level, 6 mm holes for the provided pegs.
1- Installating the device
2x stainless screws 4x35mm
Accessories required for wall mounting are supplied
2x anchors diam.6mm
Whenever possible, use the materials
provided, they have been chosen for
their qualities.
-stainless steel screws for better
moisture resistance.
8
Gauge plate of the devices Régul’
Location of the holes for the Bulleur

9
Régul’ Electronique
1- Connect the power cable of device in the
filtration cabinet.
- Phase=brown wire=on terminal 3 of the
circuit breaker.
- Neutral=blue wire=on the neutral strip.
2-Plug the cable into the device on the power
supply terminal block.
Connecting the device
Wiring terminals of the electronic board of The Bulleur
Warning : risk of electric shock.
Before working on the device, disconnect the circuit breaker.
Filtration cabinet
neutral strip
pump
The appliance must be wired so that it is always on (not connected to filtration).
The power cable must be plugged into the filter cabinet as shown below.
Connecting the « filtering force »
Connecting the « filtration stop »
Wired by a 2 x 1mm2 cable in serie on the clock contact.
Disconnect the wire connected to the filter clock contact.
Connect one of the wires to this contact and then the other by a
quick connection on the left wire-In contrast to the filtration force,
for safety reasons, it is necessary to be able to stop the filtration,
in particular when the level is too low.
M
horloge
Horloge de Filtration
M
horloge
Horloge de Filtration
Connecting the « electro valve »
The Bulleur provides on the solenoid valve connector the
24 V required to supply the valve in option (1" RAINBIRD DV100FF).
Connecting the « drain pump »
It is possible to drive a drain pump in the event of an overflow caused by rain,
connect to the connector a drain pump by a contactor or a power relay.
P N
Wired by a cable 2 x1 mm2 in parallel with the contact of the
clock.
In order for the device to be able to force the filtration when the
water level rises to level 3, closing the relay force filtration will
make it

2 - Hydraulic installation
10
Installation of the measuring rod
tube4x6
Security level
10cm mini
Protectionshealth
overfull
Slight
bias cut
The tube must descend to the
bottom of the cane.
Connect the 4 x 6 mm tube between the box
and measuring rod.
The tube must go down inside the tube to
the bottom of the rod.
The gland only serves to hold the tube in
the measuring rod
This is the place where the bubbles come out as the measurement is made

3 - Configuration menu
The Bulleur has a button inside the cabinet to adjust various parameters of the installation
The « configuration » menu allows you to select the original functions
When the Bulleur is switched on,
on the display a segment loops for 3 sec, press the key to enter
the setup/configuration menu
Chlore
pH
Sel
Temp
Configuration Consigne Calibration
N2
N3
N1
S
STOP
clic 2"
Configuration
clic
Configuration
Configuration
clic
clic 2"
clic
Tempo rain
Configuration
Configuration
factory setting 1h
clic
clic 2"
Factory setting
Configuration
Configuration
-+
« NON ou OUI »
clic
clic 2"
Function Emptying
Configuration
Configuration
factory setting OFF
-+
OFF ON
clic
clic 2"
a long click on the button
to modify a data
a single click
to validate
then appears on the screen
Security filling
to exit the menu
switch off the device
factory setting 1h
Security filling
N2
STOP
Configuration
from off to 3hours(30 min steps)
security
after reaching N3
stopping the filtering
force at the end of
the set tempo filtration
is restarted for 15 min
every 60 min
flashes
Return
Warning
« OFF » makes it possible not to take it into account a function
For exemple:
OFF filling (more filing safety)
OFF tempo rain (filtration is forced whenever the level
is above N2)
OFF drain (removes the control function of a drain pump) 11
Régul’ Electronique
flashes flashes flashes
from off to 3h(30 min steps)
security
too much filling
« DEF REMPLIS »
is displayed after the set
continuous filling time
If « ON » the drain
pump is controlled at
the set threshold
until it falls below
the threshold N2
Back to
all factory settings,
configurations
and levels

Level is going down
Level 3
« N3 »
Level is rising
Filtration force
Stop filling
Filtration
Autorisation
Level is going down
filtration force
Autorization
of filtration
Stop drain
Filling Level 1
« N1 »
Level 2
« N2 »
security
level
Filling
Stop filtration
Schematic dia gram
Emptying
Emptying
Tempo
rain
4 - Calibration of thresholds
Security filling
of 30mn until 3h
12
Emptying
Stop fillinf
below 5 cm

13
Régul’ Electronique
Level S
Low level of safety allowing to stop the filtration when the level of water
descends below it.
The filtration will be allowed in automatic mode only above level N1.
The filling is stopped by safety below a level of 5 cm(safety of measuring
tube tube cut or unplugged).
- Level N1
Filling level with control of the solenoid valve when the water level drops below
and stops the filling above N2.
- NIVEAU N2
Filling level above.
Return to automatic mode (stopping the filtration force)when the level drops
below after reaching N3.
Stop the drain when the level drops below after reaching the drain level.
Return in auto mode of filtration after the rain tempo.
- Level N3
Level filtration force as the level rises above,if the tempo rain is chosen,(in
configuration menu)the force filtration stops at the end of it,it is restarted for 15
min every 60 min to avoid a reset in manual way,by emptying,backwashing etc
- Level emptying
(appears only if the function is selected in the configuration menu)
Controls a drain pump if level passes this threshold
Stopping the drain below N2
Blinking tray display
STOP
N2
N3
N1
S
STOP
N2
N3
N1
S
N2
N3
N1
S
N2
N3
N1
S
N2
N3
N1
S
N2
N3
N1
S
stop filling flashes
stop filtration flashes
stop filtration flashes
filling
filtration automatic mode
pump not flashes
filtration force
pump flashes
EMPTYING
Functionalities of each threshold
Settings see page 14
The Bulleur has 5 levels adjustable individually to cm

calibration of the levels
Calibration of zéro and the thresholds
Put measuring rod
out of water
Calibration
flashes
Set the desired
adjustable level from 0
to the selected level
Security level
clic
Level S
Low safety threshold
filtration and filling
0 x cm
Calibration of Zéro
14
clic 2"
After taking out the
measuring rod out of water
adjust the display to 0.00
N1
S
Calibration
clic
Compressor ON
-+
-0.99 à 0.99
switching to safety
threshold setting
compressor stop
Calibration
flashes
clic 2"
clic
Level N1
Filling threshold
authorization of filtration
S x cm
N1
S
Calibration
flashes
clic 2"
Level 1 filling
set the desired level,
it is adjustable from
the previous level
to the chosen level
clic
Level N2
SThreshold stop filling
(stop drain)
N1 x cm
N1
S
Calibration
flashes
clic 2"
N2 stop filling
Set the desired level,
it is adjustable from
the previous level
to the chosen level
Calibration Calibration Calibration
clic
Level N3
Threshold force filtration
N2 x cm
N1
S
Calibration
flashes
clic 2"
N3 force filtration
Set the desired level,
it is adjustable from
the previous level to
the chosen level
clic
Level drain
Emptying level
N3 x cm
N1
S
Calibration
clic 2"
Set the desired level ,
it is adjustable from
the previous level to
the chosen level
OPTION
Calibration
Exit
the menu
of calibration
flashes
Calibration
At any time a « 2 seconds « click allows to adjust one or more levels, the calibration message
is displayed and then flashes after a second long « 2 seconds »click, if the value needs to be
changed.
clic 2"
a long clic allows by click on
the button to enter in the
menu.
aand by a second click of 2"
to modifiy a data.

15
Régul’ Electronique
N2
N3
N1
S
N2
N3
N1
S
STOP
Configuration Consigne Calibration
Chlore
pH
Sel
Temp
Configuration Consigne Calibration
STOP
N2
N3
N1
S
- Adjustment error (ERR REGLAGE)
Levels are not set in ascending order, the levels concerned blink
here, N1 and N2.
- FILLING LEVEL PROBLEM (REMPLISSAGE)
(setting from OFF to 3h-see page 12)
A continuous filling not making it possible to reach the level N2,
exceeding the set time make it possible to detect an excess of
filling.
dEF flashes at the same time as the bar on the faucet to indicate
that the filling is stopped.
To cancel this fault, press and hold the button until it disappears..
- TEMPO RAIN (TEMPO PLUIE)
(setting from OFF to 3h-see page 12)
The level N3 can be reached during a heavy rain,the filtration is
then forced down again below N3 (little chance in case of heavy
rain) the time delay then makes it possible to stop the filtration
force at the end of it in order to return to self filtration mode and
to prevent the filtration pump from continuously operating.
During the delay time, the display shows « force filtration »
At the end of the time delay the display shows RAIN MODE
(MODE PLUIE) until the level drops below level N3 by manual
draining, successive backwashes or after the natural
evaporation of the pool water
To ensure that the filtration restarts automatically it is restarted
for 15 min every 60 minutes.
5- Additional displays
Special cases and anomalies
N2
N3
N1
S
Table of contents
Popular Control Unit manuals by other brands

Massoth
Massoth eMOTION 8242060 manual

Interlogix
Interlogix 600-1046-95 installation instructions

Microdyn Nadir
Microdyn Nadir Bio-Cel L-1 Technical instructions

resideo
resideo Braukmann R295SA installation instructions

Mirion Technologies
Mirion Technologies Neutron Hp 10 user guide

Akuvox
Akuvox R29 Series installation guide