Remington GE Deluxe 2500 Quick start guide

Packaged Terminal Air Conditioners
and Heat Pumps
Architects and
Engineers Manual

STANDARD FEATURES COMPARISON
Remington, GE, Amana, Carrier and Friedrich
NOMENCLATURE PTAC 07 B 208 R
MODEL REMINGTON
PTAC=Packaged Terminal Air Conditioner
PTHP = Packaged Terminal Heat Pump
COOLING CAPACITY (BTUH) VOLTAGE
VINTAGE DESIGNATION
(Cooling with Electric Heat)
07 = 7,000
09 = 9,000 12 = 12,000 208/230 - 1 Phase
15 = 15,000 265 - 1 Phase
This comparison is based on publicly available information believed to be accurate and current at the time of publication. * Requires purchase of specific Touch Pad to enable ** Requires purchase of additional Field Mounted Kit
© 2003 McQuay International
REMINGTON GE Amana Carrier Friedrich
Features PTAC Series
Deluxe 2500 Dry Air 25 Deluxe 3500 Premium 5500 PTC/PTH
Model 52P P Series
Infrared Wireless Capability Standard –––––––
Sleep Timer Capability Standard* –––––––
Automatic “Cool Dry” Humidity Control Standard –––––––
“Rapid-Heat”/”Rapid-Cool” Technology Standard –––––––
Extended Feature Touch Pad Controls w/LED Standard – – – Standard – – –
Digital Temperature Set Point Standard – – – Standard – – –
Universal Heaters/Power Connection Standard – – – Standard – – –
Solid State Thermostat Standard Standard Standard Standard Standard Standard Option –
Concealed Manual Vent Control Standard Standard Standard Standard Standard Standard Standard Standard
Up-Front Cleanable Filter Standard Standard Standard Standard Standard Standard Standard Standard
Automatic Indoor Frost Control Standard Standard Standard Standard Standard – Option –
Corrosion Treated Chassis Standard Option Option Option – Option Option Option
Two Position Bi-Directional Discharge Grill Standard Standard Standard Standard Standard Standard Standard Standard
FanMotors 2 2222111
Fan Cycle Switch Standard Standard Standard Standard Standard Standard Standard Standard
Fan Only Setting – 2 speed Standard Standard Standard Standard Standard 1 Speed 1 Speed 1 Speed
Indoor Fan Speed Hi/Low Hi/Low Hi/Low Hi/Low Hi/Low/Auto Hi/Low Hi/Low Hi/Low
Automatic Freeze Protection Standard Standard Standard Standard Standard Standard Option –
Temperature Limiting Electronic Electronic Electronic Electronic Elect. 7-Step Electronic Mechanical Mechanical
Remote Control Thermostat Compatibility Standard Standard Standard Standard Standard Standard Option Option
“Front Desk” Control Interface Standard Standard Standard Standard Standard Standard Option Option**
Service Indicator LED Standard – – – Standard Standard – –
Self Diagnostics Standard – – – Standard Standard – –
Automatic Emergency Heat Standard – – Standard Standard Standard Standard Standard
Quick Heat Recovery Standard – – Standard Standard – – –
Auto (Random) Restart/Power Recovery Standard Standard Standard Standard Standard Standard – –
NIM PC Interface Module Standard –––––––
#110511303

Page 1
Packaged Terminal Air Conditioners and Heat Pumps
Introduction........................................................pages 1-2
Our Advantages ................................................pages 3-4
Features & Benefits................................................page 5
Engineering Guide Specifications ....................pages 6-8
Application Considerations ....................................page 9
Controls................................................................page 10
Options ................................................................page 11
Performance & Electrical Data ............................page 12
Wiring Diagrams ..................................................page 13
Wall Sleeve Installation ........................................page 14
Drain Kit Installation ............................................page 15
Unit Dimensions ..................................................page 16
Table of Contents
Bi-Directional
Discharge Grille
High Efficiency
Refrigeration Coils
Chassis Fits Any Standard
16"H x 42"W x 133/4"D
Wall Sleeve Solid State Electronic
Touch Pad Controls
Vibration Isolated
Rotary Compressor
Front Desk
Control Connection
Fan Cycle Control
Solid State
Thermostat/Freeze Sensor
Attractive, Durable
Polymer Front Panel
Universal Heater/
Power Cord
Removable / Cleanable Filters Electronic Control Pads / Optional Remotes

At Remington®, innovation is more than a mission, it’s
our history. It began in 1955, when we developed the
first through-the-wall, self-contained heating and cooling
system for individually-zoned applications. It was an
invention that revolutionized the heating and cooling
industry.
When it was first introduced, the Incremental®System, or
Packaged Terminal Air Conditioning (PTAC) as it's known
today, was a new concept, built on the premise that by
using a small air conditioning unit in each space, multi-
zone buildings could be heated and cooled more effi-
ciently and at lower first costs versus using an expensive
central plant.This major breakthrough made a
lasting impact.
Since that first Incremental System was introduced,
hundreds of thousands of Packaged Terminal Air Con-
ditioners and Heat Pumps(PTHP) have been installed in
all types of buildings, all over North America. Residents,
employees, students, visitors and more now enjoy year-
round comfort in a host of multi-room, multi-story build-
ings such as hotels/motels, office buildings, apartments,
dormitories, hospitals, nursing homes and schools.
Advantages of a "PTAC"
Lower First Cost
There is no need to pay for expensive ductwork, a cen-
tral chiller/boiler plant or the miles of piping that are
required with central systems.This can significantly
reduce both design and installation costs. Capital costs
can also be reduced by providing a unit to the space
only when it becomes occupied.
Lower Design Costs
The overall system design is greatly simplified, allowing
designers to devote more time to other areas and
reducing overall costs.
Architectural Design Freedom
Eliminates the need for large mechanical equipment
rooms, which helps increase potential leasable space.
Expensive ductwork is also eliminated, so the floor to
floor distances can be reduced without lowering ceiling
heights.
Comfort on Demand
Each occupant determines their own comfort require-
ments for their space. By using Remington units, occu-
pants can easily cool one room while simultaneously
heating another without continuously operating a central
chiller and central boiler.
Inherent Economy
Installing PTAC/PTHP units reduces the need to condi-
tion the entire building to provide comfort in one space.
For example, with this type of system, comfort condition-
ing can be provided in one area for an occupant working
after hours, while the rest of the building sleeps.
Easy Maintenance Without Disruption
Packaged Terminal products require minimal mainte-
nance because of their simple design and high-quality
construction. Routine maintenance can be easily per-
formed by a facility's own staff. If a unit becomes
inoperable, it can be repaired or replaced without
disruption of adjacent spaces.The easy, slide-in, slide-
out chassis allows one person to quickly remove and
replace an inoperable unit, minimizing downtime in the
effected space.
The new Remington PTAC/PTHP unit has revolutionized
the industry with its superior options and innovations,
bringing you the highest quality air conditioners in the
industry, year after year.
Page 2
Introduction...Packaged Terminal Air Conditioning

Page 3
Energy Savings Beyond Energy Efficiency Rating (E.E.R.)
The Digital Temperature Set Point allows each occupant
to easily set their precise desired zone comfort tempera-
ture. Eliminating the zone comfort guesswork inherent
with mechanical knob controls decreases unnecessary
running of the unit and helps prevent expensive over-
cooling/overheating.
Standard Flexible Control Module
The Remington unit has a flexible control module.This
allows the digital control pad to be removed and mount-
ed within the room on a wall within the occupied space.
Additionally, the standard features and functionality of
the controls are a superior value versus the mechanical
knobs most other PTAC's use.
Corrosion Resistant Hydrophilic Coils
On Remington units, all evaporator and condenser coils
are protected with a hydrophilic coating. This feature is
standard on all Remington units, making it an ideal
choice for any environment, including highly corrosive
environments such as Florida.This protection can also
extend the life of your coils, offering added cost savings.
Classroom Benefits
Remington units' standard features provide exceptional
benefits for classroom applications.There are no knobs
for students to remove and lose. Remington's two-motor
units are inherently quieter than a single motor design.
The Remington unit is pencil proof. The Fresh Air
Damper also arrives without additional labor required to
enable the damper.
Extra Humidity Control
Remington is the only AC manufacturer to offer the Cool-
Dry Dehumidification Mode standard on all units.The
system is designed to provide high indoor air quality
(IAQ) by reducing humidity which can help to prevent
mold/mildew build-up in conditioned space. As a result,
the conditioned air will feel and smell fresher, removing
up to 70% more humidity in the Cool-Dry mode when
compared to the standard cool mode at 50% load.
Results will vary under different loading conditions.
A Superior Choice
Remington units meet the industry standard (ASHRAE
90.1) for E.E.R.’s and capacities, and they offer much
more than that. Our money-saving operational features,
combined with our superior warranty packages, can pay
dividends both in labor savings and operational costs in
the long run.
Warranty
No other manufacturer stands behind their product like
Remington. Both our Gold Plus and Platinum Plus
Packages offer a limited one-year unit exchange warran-
ty on the entire conditioner and a refrigeration circuit unit
exchange warranty for the 2nd through 5th year.The Gold
Plus package offers an additional functional parts war-
ranty for the 2nd through 5th year. Freight costs will be
paid by the manufacturer. Please contact us for more
warranty package details.
The New Remington®16 x 42 PTAC/PTHP Series Unit...Our Advantages
Remington's contemporary design is both attractive and thoughtful - with standard
features like solid-state electronic touch pad controls that are easy to operate and
provide precise comfort settings.
This manual suits for next models
7
Table of contents
Other Remington Air Conditioner manuals
Popular Air Conditioner manuals by other brands

Fujitsu
Fujitsu ASYG 09 LLCA installation manual

York
York HVHC 07-12DS Installation & owner's manual

Carrier
Carrier Fan Coil 42B Installation, operation and maintenance manual

intensity
intensity IDUFCI60KC-3 installation manual

Frigidaire
Frigidaire FAC064K7A2 Factory parts catalog

Sanyo
Sanyo KS2432 instruction manual

Mitsubishi Electric
Mitsubishi Electric PUHZ-RP50VHA4 Service manual

Panasonic
Panasonic CS-S18HKQ Service manual

Panasonic
Panasonic CS-E15NKE3 operating instructions

Gree
Gree GWH18TC-K3DNA1B/I Service manual

Friedrich
Friedrich ZoneAire Compact P08SA owner's manual

Daikin
Daikin R32 Split Series installation manual