Table 1. Continued
DIP Switch Position Receiver Operation Mode
On-Off:
On-Off mode requires a two-input transmitter.
Push-button "1" changes the state of the output.
Push-button "2" returns the output to it's original state.
Test:
In test mode, the output will change its state and maintain it until position
4 on the DIP switch is in the off position.
Transmitter Operation Modes
Transmitter operation modes are selected using the two-position DIP Switch on the
transmitter. The time durations of the transmitter operation modes can be adjusted
using the trimpot. Refer to Figure 3 on page 4 to locate the trimpot on the transmitter.
Table 2 below describes the operation modes, and the white boxes in the diagrams
represent the position of the DIP switch.
Table 2. SRWSS 1 Transmitter Operation Modes
DIP Switch Position
Transmitter Operation Mode
2 to 62 second Repeat Transmission
Transmitter will transmit a 1.5 second transmission burst and then repeat
the burst transmission every 2-62 seconds if at least one code switch
from the eight-position DIP switch is ON and power is connected. This is
the default operation mode, with the transmitter set to repeat its
transmission every two seconds.
1 to 10 Minute Repeat Transmission
Same as mode 1, except the repeat burst transmission is 1-10 minutes.
Continuous Five-Minute Transmission
Transmitter will transmit continuously for up to five minutes as long as
the input is closed. Once the input is open or five minutes have elapsed,
the transmission will end.
One Burst Transmission
Transmitter will transmit for a duration between 1.5 seconds to 10
seconds and then go into sleep mode.
Special Sleep Mode
Sleep Mode is activated when all switches on the eight-position DIP
switch are OFF. This overrides all four other modes.
SRWSS 1 Installation and Operation Guide ver. 5 Published 09/24/08 8