Remotec AC MASTER User manual

Remotec
AC MASTER
SKU: REMEZXT600
Quickstart
This is a secure HVAC-Thermostat for Europe. To run this device please insert fresh 2 * AA LR6 batteries. Please make sure the internal battery is fully
charged. 1. Refer to your primary controller to enter into the nclusion Mode or Exclusion Mode
2. When it is prompted to enter it, please triple click the PROG button within 1 second.
3. Green ndicator flashes TW CE then stay off
mportant safety information
Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer,
distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this
equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.
What is Z-Wave?
Z-Wave is the international wireless protocol for communication in the Smart Home. This device is suited for use in the region mentioned in the Quickstart section.
Z-Wave ensures a reliable communication by reconfirming every message (two-way communication) and
every mains powered node can act as a repeater for other nodes (meshed network) in case the receiver is
not in direct wireless range of the transmitter.
This device and every other certified Z-Wave device can be used together with any other certified
Z-Wave device regardless of brand and origin as long as both are suited for the same frequency range.
f a device supports secure communication it will communicate with other devices secure as long as this
device provides the same or a higher level of security. Otherwise it will automatically turn into a lower level
of security to maintain backward compatibility.
For more information about Z-Wave technology, devices, white papers etc. please refer to www.z-wave.info.
Product Description
ZXT-600 AC Master is a Z-Wave plus certified R Bridge for split air conditioner control by receiving Z-Wave command and translating to nfrared command and
flawlessly work with any Z-Wave compliant gateway.With its over 250 brands built-in code library and ever-green up to date cloud R database supporting
advanced code learning search, ZXT-600 can easily set up and smart control most of AC brands and models actively worldwide by Z-Wave gateway.The battery
powered device will allow you to mount it anywhere you want such as wall, ceiling or put it on table and never compromise on the form factor. By supporting OTA
function, gateway can enable ZXT-600 to update firmware if newest available.
Prepare for nstallation / Reset
Please read the user manual before installing the product.
n order to include (add) a Z-Wave device to a network it must be in factory default state. Please make sure to reset the device into factory default. You can do
this by performing an Exclusion operation as described below in the manual. Every Z-Wave controller is able to perform this operation however it is recommended
to use the primary controller of the previous network to make sure the very device is excluded properly from this network.
Reset to factory default
This device also allows to be reset without any involvement of a Z-Wave controller. This procedure should only be used when the primary controller is inoperable.
Press and Hold PROG button for 3 seconds on AC Master, the Green ndicator will light up. DO NOT Release the PROG Button until Green ndicator flashes
TW CE.
Remark : Please use this procedure only when the network primary controller is missing or otherwise inoperable.
Safety Warning for Batteries
The product contains batteries. Please remove the batteries when the device is not used. Do not mix batteries of different charging level or different brands.
nstallation
http://manual.zwave.eu/backend/make.php?lang=en&sku=REMEZXT600
1 z 6
22. 7. 2019, 13:29

Apply Power to ZXT-600
- 2x AA batteries or micro USB ZXT-600 will detect the first applied power source to decide what Z-Wave device role it will be in after included into the Z-Wave
gateway: battery= sleeping device (FLiRS mode). USB power = always awake device (Always Listening mode), refer to Z-Wave Glossary for more information.
- Once the ZXT-600 is included into a Z-Wave network, the working mode (sleeping or awake) cannot be changed, unless it is excluded and re-apply the power.
- ZXT-600 can be included and operated in any Z-Wave network with other Z-Wave certified devices from other manufacturers and/or other applications. All non-
battery operated nodes within the network will act as repeaters regardless of Vendor to increase reliability of the network.
Mounting Location Tips
The ZXT-600 should be mounted on an inner wall about 5ft (1.5m) above the floor where it is readily affected by changes of the general room temperature with
freely circulating air.
Before mounting, check the material and structure of the mounting location. f the location does not have the proper material or structure, the ZXT-600 can fall and
cause an injury.
Avoid mounting above or near hot surfaces or equipment (e.g. TV, Heater, Refrigerator). Avoid mounting where it will be exposed to direct sunshine, drafts, or in a
laundry room or other enclosed space.
Better to mount your device where it has no any obstacle or blocked object between the device and your AC Appliance.
Mounting the ZXT-600
- Position ZXT-600 on wall, level and mark hole positions with pencil.
- Drill holes at marked positions, then tap in supplied wall anchors.
- nsert and tighten mounting screws as below figure
nclusion/Exclusion
On factory default the device does not belong to any Z-Wave network. The device needs to be added to an existing wireless network to communicate with the
devices of this network. This process is called Inclusion.
Devices can also be removed from a network. This process is called Exclusion. Both processes are initiated by the primary controller of the Z-Wave network. This
controller is turned into exclusion respective inclusion mode. nclusion and Exclusion is then performed doing a special manual action right on the device.
nclusion
When it is prompted to enter it, please triple click the PROG button within 1 second. Green ndicator flashes TW CE then stay off
Exclusion
When it is prompted to enter it, please triple click the PROG button within 1 second. Green ndicator flashes TW CE then stay off
Product Usage
IR Code Learning
http://manual.zwave.eu/backend/make.php?lang=en&sku=REMEZXT600
2 z 6
22. 7. 2019, 13:29

1. Refer to your primary controller user manual, enter to the browser page that can input the Configuration parameter
2. Look up Below mapping table for learning, and decide the R setting you intend to learn next.
3. Open the Gateways Configuration Brower page input parameter number 25 and parameter value (according to below Mapping Table), then complete the
Configuration process.
Then Green Indicator still turns ON for indicating the IR Code Learning Start
4. Aim the Original Air Conditioner Remote at AC Master according to below position within 1-3cm Press Power ON button on the Original Air Conditioner Remote.
f the Learning is failed, repeat Step 3 to step 4 To learn next R code, repeat Step 2 to step 4.
Successful: Green Indicator flashes TWICE Unsuccessful: Red Indicator flashes TWICE.
5. Once you finished the R Code Learning, please go to Configuration setting page on the Gateway browser and input parameter number 27 and parameter value
000 to select the dedicated AC code number 000 for learning.
Green Indicator flashes ONCE ever y time if receives a command from Gateway
Tips:
- Make sure your Original Remote is in Power OFF Status.
- Make sure your Original Remote set FAN Speed to AUTO and FAN SW NG to AUTO/ON
- Press and Hold the Power Key on Original Remote UNT L AC Master indicate Successful or Not.
- User need at least Learn the OFF (Parameter Value 0), and one Temperature Mode (Parameter Value 2 ~ 28) to complete the usage model.
- Keep away from ncandescent Light or Direct Sunlight during learning.
- Make sure R Transmitter of your Original Remote alight with learning diode of AC Master, you may also slight adjust closer or further away the distance of two
devices. Some of Remotes the R transmitter in hidden behind lens and may not installed center of remote.
- Make sure the power is good on both devices, especially the Original remote. Use Fresh Batteries in both devices recommended.
IR Learning Mapping Table can you find in the Installation Guide by the product
Communication to a Sleeping device (Wakeup)
This device is battery operated and turned into deep sleep state most of the time to save battery life time. Communication with the device is limited. n order to
communicate with the device, a static controller C is needed in the network. This controller will maintain a mailbox for the battery operated devices and store
commands that can not be received during deep sleep state. Without such a controller, communication may become impossible and/or the battery life time is
significantly decreased.
This device will wakeup regularly and announce the wakeup state by sending out a so called Wakeup Notification. The controller can then empty the mailbox.
Therefore, the device needs to be configured with the desired wakeup interval and the node D of the controller. f the device was included by a static controller this
controller will usually perform all necessary configurations. The wakeup interval is a tradeoff between maximal battery life time and the desired responses of the
device. To wakeup the device please perform the following action: Press the "PROG" button to wakeup the unit
Quick trouble shooting
Here are a few hints for network installation if things dont work as expected.
Make sure a device is in factory reset state before including. n doubt exclude before include.1.
f inclusion still fails, check if both devices use the same frequency.2.
Remove all dead devices from associations. Otherwise you will see severe delays.3.
Never use sleeping battery devices without a central controller.4.
Dont poll FL RS devices.5.
Make sure to have enough mains powered device to benefit from the meshing6.
Association - one device controls an other device
Z-Wave devices control other Z-Wave devices. The relationship between one device controlling another device is called association. n order to control a different
device, the controlling device needs to maintain a list of devices that will receive controlling commands. These lists are called association groups and they are
always related to certain events (e.g. button pressed, sensor triggers, ...). n case the event happens all devices stored in the respective association group will
receive the same wireless command wireless command, typically a 'Basic Set' Command.
Association Groups:
Group Number Maximum Nodes Description
11 Z-Wave Plus Lifeline
Configuration Parameters
Z-Wave products are supposed to work out of the box after inclusion, however certain configuration can adapt the function better to user needs or unlock further
enhanced features.
IMPORTANT: Controllers may only allow configuring signed values. n order to set values in the range 128 ... 255 the value sent in the application shall be the
http://manual.zwave.eu/backend/make.php?lang=en&sku=REMEZXT600
3 z 6
22. 7. 2019, 13:29

desired value minus 256. For example: To set a parameter to 200 it may be needed to set a value of 200 minus 256 = minus 56. n case of a two byte value the
same logic applies: Values greater than 32768 may needed to be given as negative values too.
Parameter 25: Learn R Code
Learn IR Code, refer to learning mapping table
Size: 2 Byte, Default Value: 0
Setting Description
0 - 32 Storage Location
Parameter 26: Check R Code Learning Status (Read only)
Size: 1 Byte, Default Value: 0
Setting Description
0dle - R Channel is idle
1OK - the last learning operation was completed successfully
2Learning - ZXT-600 is busy processing previous learning request
3Full All locations are being used.
4The last learning request was failed Note:The status value 0x01 and 0x04 will be reset to 0x00 after ZXT-600
receives a get command to this parameter.
Parameter 27: Set R Code Number from built-in code library
Refer to Code Finder Webpage
Size: 2 Byte, Default Value: 857
Setting Description
0 - 65535 R Code Number
Parameter 30: Set Auto Report condition Trigger by Room Temperature change
Auto report if room temperature is different from last report.
Size: 1 Byte, Default Value: 0
Setting Description
0Disable
11F (0.5C)
22F (1C)
33F (1.5C)
44F (2C)
55F (2.5C)
66F (3C)
77F (3.5C)
88F (4C)
Parameter 32: Set built-in R Emitter Control
If there have two or more Air Conditioners with the same code set that are used in the same room, user can disable the built-in IR emitter and use the external IR
emitter cable to control each air conditioner
Size: 1 Byte, Default Value: 255
Setting Description
0Disable
255 Enable
Parameter 33: Control AC SW NG function
Size: 1 Byte, Default Value: 1
http://manual.zwave.eu/backend/make.php?lang=en&sku=REMEZXT600
4 z 6
22. 7. 2019, 13:29

Setting Description
0Swing OFF
1Swing Auto
0Swing OFF
1Swing Auto
Parameter 34: Set Auto Report Condition by Time nterval
Size: 1 Byte, Default Value: 8
Setting Description
0Disable
1 - 8 Auto report by the following time interval in Hrs
Parameter 37: Calibrate Temperature reading
Size: 1 Byte, Default Value: 0
Setting Description
0 - 5 Positive range 0° - 5°C
251 - 255 Negative Range - 1°C - -5°C
Technical Data
Dimensions 128x78x22 mm
Weight 84 gr
Hardware Platform ZM5202
EAN 4896628184903
IP Class P 20
Voltage 5 V
Battery Type 2 * AA LR6
Device Type Thermostat - HVAC
Network Operation Listening Sleeping Slave
Z-Wave Version 6.61.00
Certification ID ZC10-17085735
Z-Wave Product Id 0x5254.0x0101.0x8490
Sensors Air Temperature
Color White
Thermostat HVAC Systems Supported
Firmware Updatable Updatable by Consumer by RF
Thermostat Modes AutoAwayCoolDry AirFan OnlyHeatResume
Frequency Europe - 868,4 Mhz
Maximum transmission power 5 mW
Supported Command Classes
Application Status
Association Grp nfo V3
http://manual.zwave.eu/backend/make.php?lang=en&sku=REMEZXT600
5 z 6
22. 7. 2019, 13:29

Association V2
Basic
Battery
Configuration V2
Device Reset Locally
Firmware Update Md V3
Manufacturer Specific V2
Powerlevel
Security
Sensor Multilevel V7
Thermostat Fan Mode V4
Thermostat Mode V3
Thermostat Setpoint V3
Version V2
Zwaveplus nfo V2
Explanation of Z-Wave specific terms
Controller — is a Z-Wave device with capabilities to manage the network. Controllers are typically Gateways,Remote Controls or battery operated wall
controllers.
Slave — is a Z-Wave device without capabilities to manage the network. Slaves can be sensors, actuators and even remote controls.
Primary Controller — is the central organizer of the network. t must be a controller. There can be only one primary controller in a Z-Wave network.
Inclusion — is the process of adding new Z-Wave devices into a network.
Exclusion — is the process of removing Z-Wave devices from the network.
Association — is a control relationship between a controlling device and a controlled device.
Wakeup Notification — is a special wireless message issued by a Z-Wave device to announces that is able to communicate.
Node Information Frame — is a special wireless message issued by a Z-Wave device to announce its capabilities and functions.
(c) 2019 Z-Wave Europe GmbH, Antonstr. 3, 09337 Hohenstein-Ernstthal, Germany, All rights reserved, www.zwave.eu. The template is maintained by Z-Wave
Europe GmbH. The product content is maintained by Z-Wave Europe GmbH , Supportteam, sup[email protected]. Last update of the product data: 2019-05-16
13:47:14
http://manual.zwave.eu/backend/make.php?lang=en&sku=REMEZXT600
6 z 6
22. 7. 2019, 13:29
This manual suits for next models
1
Table of contents
Other Remotec Controllers manuals
Popular Controllers manuals by other brands

Honeywell
Honeywell LYNX Touch Series Quick installation guide

Mishimoto
Mishimoto MMFAN-PWN-U installation guide

Dynamatic
Dynamatic 4000 instruction sheet

Warmup
Warmup DS-8 installation manual

IFM
IFM Ecomat 300 AC1307 Basic device manual

Mitsubishi Electric
Mitsubishi Electric Melservo-J3 Series MR-J3-B instruction manual