EURO User Manual
You’ve Made the Right Choice
Page 1
Contents
Introduction 1-5
Using EURO Panel with Code or Tag 6-7
Intelligent Setting 9
Silencing the Alarm 10
Setting Individual Areas 12-15
Chime Facility 16
Omitting Inputs 17-18
Keypad Hold Up/Personal Attack 19
Manager Menu 20
Omitting 24 hr Inputs 22
Changing Date & Time 21
Change/Add Codes or Tags 23-27
Review History Log 28
SMS Phonebook 29
Walk Testing Detectors 30
SMS Messaging System 31-32
Testing your Sounder 34
Dial Out Menu 33
Allow Engineer Menu 34
Block Remote Set 35
Perform Anti-Code Reset 35
Troubleshooting 38-39
Service & Codeholder Records 40-41
Disclaimer 42
Note the specification of EURO panels may vary
between models, and some facilities in the
manual may not be available. Check with your
installer for full details. This equipment may be
used in systems installed to a lower grade,
which will be agreed with your installation
company. There are no user serviceable parts
contained in this product. This manual is for
use with panels fitted with version 7 software.
©Castle Care-Tech 2009 (RINS1302) Issue 2

EURO User Manual
You’ve Made the Right Choice
Page 2
Using your EURO Alarm System just
couldn’t be easier!
This is the Keypad from where you
control your Alarm System*
*Please note that Keypad design may differ from that shown.
Note:
For your security, the keypad becomes disabled
for 90 seconds after 30 incorrect key-presses, or
after 6 attempts to present invalid tags. It will
subsequently be disabled again after 7 further
incorrect key-presses or after another invalid tag
is presented. Once a correct code or tag has been
registered, the keypad is returned to normal
operation.

EURO User Manual
The Euro Keypad
Page 3
The display gives you any
important messages. It will alert
you if you need to call your alarm
installation engineer.
The 10 digit numeric keypad is
where you use your PIN code.
The A B C D keys help simplify use,
and will illuminate to highlight your
choice of security cover, or flash if
there is a problem.
This is where you present your
Tag
.
Euro 1
Ti
me:
15
:
02
MAINS
FAIL

EURO User Manual
Warning Indications
Page 4
All setting points (Keypads or Tag
Readers) have LEDs to clearly indicate
what is happening.
The ‘Alert’ LED will flash if there is
information available to you. Enter your
code to see the information. After a code
has been entered, one of the following
LEDs will light: Alarm, tamper or fault. The
relevant detail of the problem will be
shown on the display. To clear the display,
press the ‘Yes’ key (or the display will
clear automatically after 3 minutes.)
The ‘Alarm’ LED will flash after code entry
if an alarm occurs.
The ‘Tamper’ LED will flash after code
entry if the wiring or equipment is
tampered with.
The ‘Fault’ LED will light after code entry
to indicate if a technical fault occurs.
The ‘Unset’ LED will light for 5 seconds if
the panel is completely Unset (steady) or if
some areas remain Set (flashing). It will
also illuminate during the setting
procedure, turning off once set.
Alert Alarm Tamper Fault Unset

EURO User Manual
Using Tags
Page 5
The EURO high security proximity tag
(or card) will set or unset your alarm
system with the minimum of fuss or
complexity.
The tag contains NO batteries and is
completely maintenance free.
Just touch the tag to the illuminated
logo to use.
The Keypad will BEEP to acknowledge
the tag.
Security Checks
Before you set your system:
You must ensure all doors and
windows are securely closed and any
pets or people are excluded from areas
protected by movement sensors.
Close Doors & Windows
Exclude Pets and People

EURO User Manual
Leaving the Building
Page 6
If you are leaving the building, go
to your keypad and key in your PIN
code, or present your tag.
The Exit Tone Starts
The appropriate area (ABCD) keys
will illuminate.
(If flexi-set is enabled you will be able to
choose which areas you set, see page 13)
Leave by agreed Exit Route
Close and Lock the Final Exit
Door
Finally, press the ‘Push to Set’
button (if fitted) that is mounted
externally by the final exit door.
The Exit Tone will cease
EURO is now SET
SETTING
[009]
OFFICE
If your exit is timed,
you will see the above
screen.
If you use a Push-to-
Set button, or final-
door-set, you will see
the screen below.
E
uro
1
Ti
me:
15
:
02
Leave via
Exit Route

EURO User Manual
Entering the Building
Page 7
To enter the building you
must
use the agreed entry route and
go straight to the keypad.
The Entry Tone will be sounding
“beep – beep – beep –“
Key in your PIN code, or present
your tag.
The Entry Tone will cease
To indicate that the system has
unset, the unset LED will
illuminate for five seconds.
EURO is now UNSET
ENTRY [010]
TIME
**
ENTRY [020]
TIME

EURO User Manual
Using an External Proximity
Reader
Page 8
Setting your EURO panel with the
External Proximity Reader
Present a valid tag to the reader and then
remove it.
The GREEN LED will come on
Present the same tag to the reader, and then
remove it. The exit time will start on the
control panel.
The RED LED may be programmed to
illuminate under certain actions (for example
when the system is set).
Unsetting your EURO panel with the
External Proximity Reader
Present a valid tag to the reader and then
remove it.
The GREEN LED or RED LED (if
programmed) will be displayed.
Present the same tag to the reader, and then
remove it. The exit time will start on the
control panel.
The RED LED will extinguish, and after 25
seconds the GREEN LED will extinguish.

EURO User Manual
Intelligent Set
Page 9
If you wish to set your EURO panel and
stay in the building (e.g. set the alarm
at night), the EURO’s intelligent
operating system will realise which level
of security you require and will set only
part of the system.
You will NOT need to press a Push-
to-Set button if you set only part of
a system.
If intelligent set is not installed on your
system, you may part set the system as
described on pages 12-13.
To Part Set EURO go to the keypad and
enter your PIN code or present your Tag.
The appropriate
A B C D
keys will
illuminate
Exit tone will start
Leave the protected area and retire to
the un-protected area (e.g. upstairs).
EURO will detect you have gone upstairs
and set the appropriate areas
accordingly.
After a pre-set time the exit tone will
cease.
Your EURO panel is now Part Set

EURO User Manual
Silencing Alarms
Page 10
If an alarm tone sounds, the alert
LED will flash:
Just key in your PIN code or
Present your tag.
The Alarm will stop sounding
The display will indicate the why
the alarm has activated.
Press the
‘YES’
Key
EURO will advise you on any
action that is needed. If the ‘Alert’
LED indication remains lit, there is
additional information available.
Enter your PIN or present your
tag to view.
Call Engineer
Low Volts
Al
arm
Sil
ence
d
Low Volts

EURO User Manual
Engineer Reset
Page 11
When an alarm has been cancelled and
the Police have been notified by the
Alarm Receiving Centre (ARC), you will
see the screen shown left when you try
to use the system.
It is usually necessary for an engineer
from your installation company to check
the installation and reset the system for
further use.
But if you have caused
the alarm in error
your Alarm
Receiving Centre or Alarm Installation
Company may permit you to reset the
system without an engineer present.
You will be required to quote a 6-digit
code by telephone (advise them that the
system is a Castle Euro ONE). You will
then be given a special code which will
reset the system
for that one occasion
only.
Press ‘NO’
Enter the anti-code given to you by your
installation company.
You alarm in now restored and ready to
use.
This 6-digit code is also displayed in the
‘user menu’ – see page 35.
Q
uo
t
e
G19867
Anti-Code Needed
E
uro
1
Time:15:15
E
ng
i
neer
R
es
t
ore
Performed
Q
uo
t
e
G19867
Anti-Code Needed
E
n
t
er your
C
o
d
e
[* ]

EURO User Manual
The A B C D Keys
Page 12
Sometimes your security needs
will be a little more complex and
you will need to use the
A B C D
keys.
Your installer can also give names
to all four of the
A B C D
areas,
so that you can easily identify
them.
For example:
A
=Reception or A
ll Set
B
=Warehouse B
edtime
Set
C
=Office
C
at in Lounge
D
=Storeroom
D
og in
Study
In addition, names can be given to
the whole system
‘ALL AREAS’
These will be displayed when
setting the system.
Note: The number of areas available
depends upon the model.
EURO 44: ABCD01
EURO 76: ABCD0123
EURO 162: ABCD01234567
EURO 280: ABCD0123456789
E
uro
1
Ti
me:
15
:
20
E
uro
1
Ti
me:
15
:
21
SETTING
ALL AREAS

EURO User Manual
Codes with Flexi-Set
Page 13
For greater flexibility in setting
parts of your system, you can
make a choice at the keypad.
Key in your PIN code or present
your Tag.
If you do not wish to set all the
areas assigned to your PIN
code/tag, simply select the areas
you wish to Set by pressing the
relevant
A B C D key(s).
To change your mind, press the
relevant A B C D key(s) again.
Press the Yes key to accept
Setting areas will now be displayed,
with the corresponding area keys
being lit.
EURO will now set the selected
areas.
SETTING
ALL AREAS
SET
AREAS
[ABCD]

EURO User Manual
Flexi-Unset
Page 14
When EURO is already set and you
wish to unset:
Key in your PIN code or present
your tag.
If entry timer has started:
All areas for which the tag or PIN code is
valid will be unset. Any areas set for which
the code is not valid will remain set, e.g. if
A and B are set:
If a tag valid for area ‘A’ only is
presented, then area A will be unset,
leaving B set.
If a tag valid for areas ‘A B’ is presented,
both A & B will be unset.
If a tag valid for areas ‘A B C’ is
presented, it will unset A & B, leaving C
unset.
If entry timer is not running:
You will be asked if you wish to set any
areas currently not set. Press ‘YES’ to do
so, or press ‘NO’ to unset the system.
If there are NO areas set for which the
code is valid, the system will SET as
described on page 13.
Note: Your alarm installing company may have
programmed keypads to set and unset certain
areas only.
E
uro
1
Ti
me:
15
:
25

EURO User Manual
Flexi-Unset
Page 15
If your codes have been set up with
Flexi-Unset enabled, you will
always have a choice of what areas
you would like to set or unset,
regardless of whether the entry
timer is running or not – providing
you have a code valid for the
relevant areas.
This function can only be enabled
by your alarm installing company,
and will not be permitted if your
system is designed to comply with
clause 6.4.5 of DD243:2004. Ask
your installer for further details.

EURO User Manual
The Chime Facility
Page 16
The ‘C’ key can be used to select
the ‘chime’ facility while the
system is Unset.
For example, you may wish to be
alerted if someone enters through a
particular door during the day.
Simply press the ‘C’ key.
The display will show a ‘C’
Now if the door opens you will be
alerted by the ‘chime’ tone.
To cancel the ‘Chime’ function,
simply press ‘C’ again.
Note: This is only operative on detectors
programmed for this purpose. If multiple
detectors are programmed to permit this, the
sounder will not distinguish between them.
E
uro
1
Time: 15:31 c
Euro 1
Ti
me:
15
:
32

EURO User Manual
Deliberately omitting an
Input when leaving the
Building
Page 17
In a domestic setting you may wish to
ignore a window you have deliberately
left open in the summer time. There
may be another fault on the system
which you want to ignore when you set
the system.
Enter your PIN code or present your
tag.
The display will ask if you wish to set
with the fault.
To omit the fault, Press ‘YES’ (or ‘NO’
if you do not wish to omit).
The system will then set as normal.
The fault will be omitted for this one
arming period only.
NOTE iiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiii iiii
Only doors or windows already open
can be omitted in this way.
The system may be programmed to be
able to set with certain types of fault
(e.g. mains fail) but not others (e.g.
telephone line fault).
Set with Fault?
Bedroom Window

EURO User Manual
Deliberately omitting an
Input when leaving the
Building
Page 18
At some time you may wish to
isolate a detector if a room is
occupied.
Enter your PIN code or tag.
While the exit tone is sounding
press the ‘YES’ key.
When the ‘OMIT INPUT’ menu is
displayed:
Key in the number of the input you
wish to omit and press ‘YES’.
(Always use a leading zero, eg 02 is input
2. On larger systems 002 is input 2)
If it has been accepted it will be
displayed on the screen.
Repeat for any other inputs that
need to be omitted.
After 10 seconds EURO will
begin to set
These inputs will be omitted
for this one period only.
OMIT
INPUT?

EURO User Manual
Keypad Hold-Up
Page 19
If you need to summon personal
assistance in an emergency, EURO
allows you to do so.
Simply press the ‘1’ and ‘7’ keys at
the same time.
To reset:
Enter you PIN code or present your
Tag.
Note ghgfiiiiiiiiiiiiiiiiiiiiiiiiiiiiiii
This facility is only available if it has
been enabled by your alarm
installer. 2-Key PA and any duress
codes programmed on the system
by your engineer are not permitted
to send a signal to the Alarm
Receiving Centre under police
regulations in England, Wales or
Northern Ireland.
E
uro
1
Ti
me:
15
:
40
Table of contents
Popular Security System manuals by other brands

Channel Safety Systems
Channel Safety Systems ENTRitech installation guide

ADT
ADT ACCORD XPC installation manual

ELRO
ELRO DWH SERIES Installation and operation instruction manual

CSL
CSL DualCom Pro Visonic PowerMaster quick start guide

Carmanah
Carmanah G Series user manual

Argus Security
Argus Security SGCP100-IS quick start guide

Sylvania
Sylvania SY14Q5144C series instruction manual

Abrams
Abrams StarEye Series Installation and operation guide

Honeywell
Honeywell Ademco VISTA-20PCN Programming guide

Geutebruck
Geutebruck G-ST Perimeter+ Instructions for use

Buffalo filter
Buffalo filter BOWA Operator's manual

Cooper Wheelock
Cooper Wheelock RSSPA-24MCC-NW specification