Resol Datalogger DL2 Instruction manual

Datalogger DL2
www.resol.com
Thank you for buying this RESOL product.
Please read this manual carefully to get the best performance from this unit.
Please keep this manual carefully.
RESOL Datalogger DL2
Mounting
Connection
Operation
Manual
*48003740*
48003740
EN

Datalogger DL2
© RESOL 09252 dl2.monen.indd
|2
Table of contents
Description of symbols .............................................2
Disposal ......................................................................2
Information about the product................................3
1. Overview .......................................................3
2. Installation.....................................................4
2.1 Mounting........................................................................ 4
2.2 Connection ................................................................... 4
3. Operation ......................................................5
4. Data transfer .................................................5
5. Display............................................................5
5.1 Status LED..................................................................... 5
5.2 Fill level of data memory ........................................... 6
6. Connecting the datalogger ..........................6
6.1 Access via LAN............................................................ 6
6.2 Access via Internet...................................................... 7
7. Quickguide Configuration ...........................8
8. Start screen web interface DL2 ...................... 8
8.1 State................................................................................ 9
9. Data............................................................................. 10
9.1 Adapting live data ...................................................... 11
9.2 Displaying live data in a system scheme ............... 12
10. Configuration .........................................................14
10.1 Configuration: General............................................. 14
10.2 Configuration: Network...........................................14
10.3 Configuration:Time...................................................15
10.4 Configuration: Firmware Update ...........................15
10.5 Configuration: Remote Access ...............................15
10.6 About DL2 .................................................................. 15
11. Source code.................................................15
Imprint ......................................................................................16
Safety advice
Please pay attention to the following safety advice in order
to avoid danger and damage to people and property.
Attention should be paid to
the statutory provisions for prevention of industrial•
accidents,
the statutory provisions for environmental protection,•
the Health and Safety at Work Act 1974•
Part P of the Building Regulations 2005•
BS7671 Requirements for electrical installations and•
relevant safety regulations Subject to technical change. Errors excepted.
This manual contains important information about safe and
proper usage of this product. Please keep this manual for
future reference.
Description of symbols
Disposal
WARNING!
Warnings are indicated with a
warning triangle!
Signal words describe the danger that may occur, when it
is not avoided.
Warning•means that injuries or even danger of life
can occur.
Dispose of the packaging in an environmentally sound•
manner.
Dispose of old appliances in an environmentally sound•
manner. Upon request we will take back your old appli-
ances bought from us and guarantee environmentally-
friendly disposal of the devices.
Information about the product
Proper usage
The datalogger DL2 may only be used in conjunction with con-
trollers with VBus®output in order to log and access data in
compliance with the technical data specified in this manual.
Improper use excludes all liability claims.
CE-Declaration of conformity
The product complies with the relevant
directives and is therefore labelled with the
CE mark. The Declaration of Conformity
is available upon request, please contact
RESOL.
These instructions are exclusively addressed to authorised
skilled personnel.
Only qualified electricians should carry out electrical•
works.
Initial installation must be effected by qualified person-•
nel named by the manufacturer
Note
Notes are indicated with an information symbol.
Arrows indicate instruction steps that should be«
carried out.

Datalogger DL2
© RESOL 09252 dl2.monen.indd
3 |
Included with the DL2:
Datalogger DL2, ready to plug in,•
with mains adapter and RESOL
VBus®-cable
Network cable, 1 m•
Wall plugs and screws•
Terminal block (for extending the•
RESOL VBus® -cable)
This additional module enables the acquisition and storage
of large amounts of data (such as measuring and balance va-
lues of the solar system) over a long period of time.The DL2
can be configured and read-out with a standard Internet
browser via its integrated web interface. For transmission
of the data stored in the internal memory of the DL2 to a
PC, an SD card can be used.
The DL2 is appropriate for all controllers with RESOL
VBus®. It can be connected directly to a PC or router for
remote access and thus enables comfortable system moni-
toring for yield monitoring or for diagnostics of faults.
• Visualisationofsystemstates
• Yieldcontrol
• Easycongurationbyintegratedwebinterface
for standard Internet browsers
• OptionalSDcard
• Exportfunctionforfurtherdataprocessingin
spreadsheet programs
• DirectconnectionofPCorrouterforremote
access
Technical data
Housing:
Plastic PC-ABS and PMMA
Protection type: IP 20 / DIN 40050
Ambient temperature: 0 ... 40 °C
Dimensions: Ø130 mm,
depth 45 mm
Mounting: wall mounting
Display: Bar LED for monitoring the
memory capacity, 1 illuminated push-
button for presentation of the SD
card status
Interfaces: VBus®for connection to
RESOL controllers. Ethernet (LAN),
Auto MDIX 10/100 Base TX
Power consumption: 1,75 W
Power supply:
Input voltage of mains adapter:
100 ... 240 V
Rated current: 350 mA
Input voltage of Datalogger:
5V DC ± 5 %
Memory: 180 MB internal memory,
with a logging interval of 5 min. suffi-
cient for:
• 30monthsforasystemswithone
DeltaSol
®M, one HKM and one
WMZ module
• 60 months for a system with one
DeltaSol
®M and one HKM
• 120monthsforasystemwithone
DeltaSol
®M
1. Overview
Note
The SD card is not used for increasing the
internal memory capacity. It is used for data
transfer only.

Datalogger DL2
© RESOL 09252 dl2.monen.indd
|4
2.1 Mounting
The unit must only be located in dry interior locations. It is
not suitable for installation in hazardous locations and should
not be placed close to any electromagnetic fields.
Please pay attention to separate routing of sensor cables and
mains cables in order to avoid interferences.
Choose a mounting place«
Drill two holes (Ø 6mm) next to each other at a di-«
stance of 113 mm and insert the enclosed wall plugs.
Attach the base by means of the enclosed screws«
(4 x 40 mm) (1).
2. Installation WARNING!
Always disconnect the device
from power supply before opening
the housing!
2.2 Connection
(1)
Connect the datalogger (pos.1) to other modules in
the following order:
Connect the data cable (RESOL VBus«®, pos.3) to the
RESOL controller (pos.4). Extend, if necessary, with en-
closed screw terminal and (twisted) two-wire cable.
Plug mains adapter (Pos.2) into the mains socket.«
For direct connection of a router or PC, connect the«
datalogger to the router (pos. 7) or PC (pos. 8) by
means of the network cable (enclosed, pos.6).
Router
1
2
3
4
6
7
8
The power supply to the device must be carried out via an
external mains adapter and the supply voltage must be
100 ... 240 V~ (50 ... 60 Hz).
The DL2 is supplied with connected mains adapter and
VBus®-cable.
VBus®connection at terminals:
1 / 2 = VBus®- connection 1
3 / 4 = VBus®- connection 2
LEDs
SD card
LAN socket
interior view
terminals

Datalogger DL2
© RESOL 09252 dl2.monen.indd
5 |
off booting in progress or no mains voltage
green flashing SD card has been recognised; DL2
data are being copied to the SD card.
Do not remove the SD card; firmware
update in progress
green SD card can be removed
red flashing error occured during copy process
red mains supply ok; operating system
ready for operation
3. Operation
The status LED (integrated into the button) visualises the
operating state of the DL2.
The datalogger can be configured, read out and deleted via
the integrated web interface.The DL2 is additionally equip-
ped with a manual reset button.The following functions can
be carried out by pushing the button:
Deleting the internal memory; the settings will not•
be deleted. For this purpose, press the button for
more than 5 but less than 10 seconds. All LEDs will
be flashing.
Resetting the datalogger to the factory settings. For this•
purpose, press the button for more than 10 seconds.
All LEDs will be illuminated. This reset process can take
several minutes.
5. Displays
5.1 Status LED
fill level
data memory
reset button
Status LED
side view: SD card slot
side view: LAN socket
For data transfer from the internal memory of the DL2,
an SD card can be used:
Insert the SD card into the card slot«
The status LED flashes green: The card has been«
re cog nised and d at a are being autom atic ally
transferred
After data transfer, the status LED is illuminated«
(green), the SD card can be removed
For further information about further processing see
RESOL ServiceCenter manual
4. Data transfer
Note
The SD card is not used for increasing the
internal memory capacity. It is used for data
transfer only.

Datalogger DL2
© RESOL 09252 dl2.monen.indd
|6
6. Connecting the datalogger
The datalogger is designed for direct connection to a PC
via a LAN connection or a router and is used for remote
access. Please carry out the following steps:
1. Install the search tool:
The search tool can either be started from the
CD (DL2DiscoverToolSetup.exe) or from the
Internet (http://www.resol-dl2.de/discover/)
(Confirm the security enquiry about the digital signature)
5.2 Fill level of data memory The fill level LEDs visualise the current fill level of the data-
logger, i.e. the internal memory capacity used.
One bar corresponds to 10 % of the internal memory
capacity: Permanent illumination means that the memory
capacity is fully used. Flashing LEDs indicate the level at
which data are being stored.
Example:When the third bar from the bottom is flashing, the
capacity used is larger than 20% but smaller than 30 %.
Note:
When the DL2 is used in conjunction with a
Gigabit-Network device (laptop, switch, etc.),
problems can occur when the connection is being
established. In this case, we recommend using a
100 Mbit-switch between the two devices. It is
also possible to change the network properties
to “10 MBit/s half duplex” (see below).
In order to start the DL2-Discover-Tool, Java
version 6 or higher is required.
6.1 Access via LAN
Example:Changingthenetworkproperties
The settings option of the network properties can vary.The
following steps are used as an example only:
Select the connection by double clicking on the corre-«
sponding icon
Select the “General tab” and click on the “Properties”«
button
Click on “Extended” and set the media type to “10«
MBit/s halfduplex”

Datalogger DL2
© RESOL 09252 dl2.monen.indd
7 |
2a. Starting the tool from the Internet:
The datalogger will automatically be searched and dis-
played as soon as it is found by the search tool.If several
dataloggers are found in the local network, they will be
listed in the “RESOL devices found” list.The name men-
tioned in this list is the device name which can be set on
the “General” Configuration page of the web interface.
2b. Installation from the CD:
Start “DL2 DiscoverToolSetup.exe”. The search tool«
will be installed under “Programme\RESOL\DL2Dis-
coverTool”
Start the DL2 Discovertool. The DL2 will automatically«
be searched and displayed as soon as it is found by the
search tool. If several dataloggers are found in the lo-
cal network, they will be listed in the “RESOL devices
found” list. The name mentioned in this list is the device
name which can be set on the “General” Configuration
page of the web interface.
Mark the datalogger found by the tool by clicking it«
Click “Open”«
3. The standard web browser opens
Enter username and password. Username and pass-«
word are “admin” (factory setting).
For accessing the DL2 via Internet, the router has to be
setup first. For setup follow the following steps:
6.2 Access via Internet
Note:
The discover tool is not usable for DL2 access.
The IP address must be known. Either a static IP
address is used or a dynamic domain server has
to be used.
Since the IP address usually changes every day, it
is recommend to use a dynamic Domain Name
Server (Dyn DNS). For further information on
detecting a Dyn DNS, please see corresponding
documentation.
Port number Service
443 Web interface
7053 ServiceCenter access
Carry out port routing in the router. For further infor-«
mation see router documentation.

Datalogger DL2
© RESOL 09252 dl2.monen.indd
|8
7. Quickguide Configuration Change username and password for web interface«
access (see 10.1)
Adjust date and time (see 10.3)«
Enable firmware update (see 10.4)«
Change the remote access password for access to the«
corresponding controller (see 10.5)
Change the FTP password for file import (see 9.2)«
Print configuration (see 10)«
The DL2 is now ready for use.
8. Start screen of the DL2 Web Interface
navigation bar
language selection
variable main window
Click on the tab in the navigation bar in order to access«
the different sub-windows of the web interface
Note:
If the automatic firmware update is activated (see
10.4), the Web Interface will be updated regular-
ly.With each new version, the operation and the
graphical user interface may change and hence
differ from those described in this manual.
Previous adjustments will not be reset or over-
written when a firmware update is carried out.
Note:
Change all passwords! If you do not change the
passwords, unconditional access for third persons
can be possible!
The passwords are not visible on the printout of
the configuration. Note down the passwords and
keep them in an appropriate place!

Datalogger DL2
© RESOL 09252 dl2.monen.indd
9 |
State: General
1: Current time setting of the DL2
1a: Time shift to GMT (in hours)
2: Time since last reset
3: Sum of all bytes received since last reset
4: Sum of all data packets received since last reset
5: Number of packets in a communication cycle
6: Sum of all data logged in the internal memory of the
DL2
7: Free memory capacity
8: Estimated remaining logging time
1
3
2
4
1a
6
7
8
5
State: Network
This window shows the current network configuration of
the DL2.
{
example
8.1 State The state window consists of two different sub-windows:
“General” and “Network”.

Datalogger DL2
© RESOL 09252 dl2.monen.indd
|10
Data download
Text (Tabulator character, Windows):•
generates a text file which is optimised for further pro-
cessing in Windows. A tabulator character separates
the data from each other.
Text (Semicolon, Windows):•
generates a text file which is optimised for further
processing in Windows. A semicolon separates the data
from each other.
Text (Tabulator character, Linux):•
generates a text file which is optimised for further pro-
cessing in Linux / MacOS X, etc. A tabulator character
separates the data from each other.
Text (Semicolon, Linux):•
generates a text file which is optimised for further pro-
cessing in Linux / MacOS X, etc. A semicolon separates
the data from each other.
HTML Table:•
data are represented in a table in a HTML file
HTML List:•
data are represented in a HTML file as a nested list.
Spreadsheet processing:•
data are issued in .xls format for direct processing with
a compatible spreadsheet software (max. 60.000 data
records)
VBus Protocol Data:•
data are issued in a file format suitable for further pro-
cessing in the RESOL ServiceCenter or in the RESOL
Data Center
In this sub-window, the data stored in the internal memory
of the DL2 can be read.
The DL2 web interface provides different tabs which are
described in the following section.
9. Data
Live-Data The current data of the connected VBus®devices are
displayed, such as: temperature, pump speed, heat quan-
tity, etc. The values will automatically be updated every
10 seconds.
Select the data format for data download.
Note:
The download time depends on the selected file
format.For large amounts of data, we recommend
downloading the data in theVBus Protocol Data
format and converting them afterwards by means
of the RESOL ServiceCenter Software (seeRESOL
ServiceCenter Software manual) included with
the DL2.
Erase data In order to delete all data, click on the “Yes, erase all logged
data” button.

Datalogger DL2
© RESOL 09252 dl2.monen.indd
11 |
9.1 Adapting live data
Adapting the units of the live data display
Search and discover DL2«
Open web interface DL2«
Select the “Data” tab«
Select “Customize”«
Select “Temperature unit”«
Do not convert (Use °C) =
All temperatures are displayed in °C
[example: 30°C are displayed as 30°C]
Convert °C to °F =
The unit is changed from °C to °F and the numeric values
are converted
(recommended for control units which are set to the
temperature unit °C or which have no temperature unit
adjustment)
[example: 30°C are displayed as 86°F]
Treat °C as °F =
The unit is changed from °C to °F without converting the
numeric value
(recommended for control units which are set to the
temperature unit °F)
[example: 30°C are displayed as 30°F]
Click on “Generate”«
A new tab or page in your web browser appears. Save
this template (HTML format), select your folder, rena-
me the template, if you want to. Go back to the web
interface of your DL2. Select “Data” / “Customize”
Click on “Browse”«
Select the template generated in the previous step«
Click on “Upload”«

Datalogger DL2
© RESOL 09252 dl2.monen.indd
|12
Click on “Generate”«
A new tab or page in your web browser appears. Save
this template (HTML format), select your folder, rena-
me the template, if you want to. Go back to the web
interface of your DL2. Select “Data” / “Customize”
Open the template in HTML format generated in the«
previous step using a text editor, carry out the desired
changes and save them. Further information about
“HTML” can be found via Google®
Click on “Browse”«
Select the template generated in the previous step«
Click on “Upload”«
Adapting the units of the live data display
9.2 Displaying live data in a system scheme
Live data can also be displayed in a graphical system scheme
in the web interface.
To do that, a system scheme of the individual solar thermal
system has to be tagged with the necessary VBus® display
boxes in the RESOL ServiceCenter software and then
exported into the DL2.
To do so, proceed as follows:
Select the tab “Configuration” in the DL2 web inter-«
face
Adjust “Enable FTP access??” to “Yes” in the “FTP«
access” screen
Click “Save changes” to save the adjustment«
Now the FTP access, which is required for the export of
the system scheme, is enabled.
The next steps have to be carried out in the RSC soft-
ware.

Datalogger DL2
© RESOL 09252 dl2.monen.indd
13 |
Assign a jpeg-formatted system scheme as background«
graphic in “VBuslogging / Designer”
Place the VBus«®display boxes into the system
scheme
Click „Export to DL2” when ready«
Now the dialogue window „Export designer document to
DL2” appears.
Enter the IP address in which the system scheme is to«
be displayed into the box marked “DL2 host name”
Enter user name and password into “DL2 user name”«
and “DL2 password”
Select “USE DL2…” if the system scheme is to be dis-«
played in the DL2 web interface
If the system scheme is to be saved outside the DL2,«
select “Use custom URL” and enter the path
Confirm by clicking “OK”«
This window confirms the successfully completed export.
By clicking “OK”, the web interface with the new system
scheme will open automatically.
When opening the web interface conventionally, the sy-
stem scheme display can be accessed by clicking the button
“Live data as SVG image” under “Data” / “Live”.

Datalogger DL2
© RESOL 09252 dl2.monen.indd
|14
10.2 Configuration: Network In the configuration window “Network”, the settings
mentioned below have to be carried out. When the auto-
configuration is not enabled, all network parameters have
to be entered manually into the fields below.
Enable / disable the LAN auto configuration«
Information such as IP address, IP netmask, etc. is indicated.«
10. Configuration In the following sub-windows of the web interface, the set-
tings of the DL2 can be changed.
In order to save the changes, click on “Save changes”.«
The “Print Configuration” button:
In order to print the current configuration of the web«
interface, click on “Print Configuration”.
Logging mode
There are two types of logging modes:
Cyclic•(factory setting):
If the internal memory of the DL2 is full, the oldest data
packets will be overwritten.
Linear:•
If the internal memory of the DL2 is full, no further
data will be logged.
10.1 Configuration: General In the configuration window“General” carry out the following
settings:
Enter username«
Enter password«
Repeat password«
Enter device name (characters permitted: letters,«
numbers, underline character)
Adjust logging interval (1 ... 86400 s; the smaller the«
interval, the more capacity is required)
Adjust logging mode«
Username and password are required for the next access
to the web interface
Note:
If you have forgotten your password, please carry
out the following steps: Copy the data onto an SD
card (see chapter 6) and afterwards reset the DL2
(see chapter 5). The DL2 will then be set back to
the factory settings.

Datalogger DL2
© RESOL 09252 dl2.monen.indd
15 |
10.3 Configuration:Time In the configuration window “Time”, carry out the following
settings:
Enter the timezone«
Adjust the update interval«
Enable / disable the network time synchronisation function«
Enter NTP server address«
Manually adjust the time settings«
10.4 Configuration: Firmware Update In the configuration window “Firmware Update” , carry out
the following settings:
Enable / disable automatic firmware update«
Enter update URL«
Adjust update interval«
The firmware update ensures that the internal software of
the DL2 is always up to date.
10.6 About DL2 In this window, details about open source applications and
libraries covered are shown.
10.5 Configuration: Remote access
Enter old remote access password (factory setting: vbus)«
Enter new remote access password«
Confirm new password«
These adjustments are required for accessing the controller
via the datalogger by means of the Service Center Software
or the RESOL Data Center.
11. Source code You can order a copy of the corresponding source codes
and compilation scripts on DVD for a handling and shipping
fee of EUR 20,- from:
RESOL - Elektronische Regelungen GmbH
Heiskamstraße 10
45527 Hattingen
GERMANY
Please include the version number of your firmware in your
order. (e.g.:“1.0 (200805241128)” indicated at the bottom of
every web interface page).You must not specify more than
one version per order.

Datalogger DL2
© RESOL 09252 dl2.monen.indd
|16
Distributed by:
Please note:
The design and the specifications may be changed without notice.
The illustrations may differ from the original product.
RESOL - Elektronische Regelungen GmbH
Heiskampstraße 10
45527 Hattingen / Germany
Tel.: +49 (0) 23 24 / 96 48 - 0
Fax: +49 (0) 23 24 / 96 48 - 755
www.resol.de
info@resol.de
Reprinting / copying
This mounting- and operation manual including all parts is
copyrighted. Another use outside the copyright requires
the approval of RESOL - Elektronische Regelungen GmbH.
This especially applies for copies, translations, microfilms
and the storage into electronic systems.
Editor: RESOL - Elektronische Regelungen GmbH
Important notice:
We took a lot of care with the texts and drawings of this
manual and to the best of our knowledge and consent.As
faults can never be excluded, please note:Your own calcu-
lations and plans, under consideration of the current stan-
dards and directions should only be basis for your projects.
We do not offer a guarantee for the completeness of the
drawings and texts of this manual - they only represent
some examples. They can only be used at your own risk.
No liability is assumed for incorrect, incomplete or false
information and / or the resulting damages.
Other manuals for Datalogger DL2
2
This manual suits for next models
1
Table of contents
Other Resol Data Logger manuals