REVENTON CODE Series User manual

Domestic axial fan with throttle
CODE Series
User Manual
Introduction
Thank you for choosing our product. Reading of this manual
is required for proper use of the device and absolute
observance to its guidelines is fundamental condition
of security.
All users of the device should have free access
to the manual and in case of resale, the instruction must
be attached to the product.
Package contents
- domestic axial fan CODE
- user manual
Transport and storage
The fan should be transported and stored in the original
packaging in a dry place protected from contamination,
until it is installed. Moreover, the fan should be protected
from the shocks.
Application
Axial fans from the CODE series are designed for wall
mounting. They are used for ventilation of small spaces
such as a bathroom or kitchen.
The device in white color version.
Construction of the device
1 –Panel 2 –Sensor Cover 3 –Sealing
4 –Sensor/Timer 5 –Base 6 –Motor
7 –Rotor 8 –Throttle frame 9 –Throttle
10 –Fastening ring 11 –Frame 12 –Screws
13 –Wire terminal 14 –Switch 15 - Diode
Dimensions (in mm)
MODEL
ØA
B
C
D
CODE 100
98
157
60
21
CODE 120
118
157
65
21
CODE 150
148
200
76
21
Technical data
MODEL
CODE 100
CODE 120
CODE 150
Maximum aiflow [m3/h]
130
240
320
Maximum compression [Pa]
36
45
60
Voltage [V]/Frequency [Hz]
230/50-60
230/50-60
230/50-60
Rated current [A]
0,072
0,11
0,138
Engine speed [rpm]
2400
2200
2000
Engine power [W]
12
16
18
IP protection degree [-]
X2
X2
X2
Noize [dB(A)]
34
34
35
Installation instructions
In order to accomplish the installation of the device
successfully and enable the safe usage of the fan
in the future, it is essential to follow the instructions in this
manual.
Before installing and connecting the fan, check that it has
not been damaged during transport or storage (breakage,
distortion).
Check whether the technical data on the nameplate
corresponds to the electrical installation parameters.
The device should be mounted on a flat surface.
If irregularities are not found, you can proceed
with the installation as follows:
- prepare appropriate electrical wires
- mark the location of mounting holes
- drill the holes and put expansion bolts in them
- place the fan in the right place and tighten screw it
- connect the device to electrical grid
The electrical connection must be in accordance
with the wiring diagram in the terminal box.
Warnings and precautions
During the operation of the device, the following
precautions must be observed:
- before performing any work, the device must
be disconnected from the power supply
- the fan is intended only for ventilation of rooms with small
and medium cubature
- installation height of the exhaust fan min. 2.3 m
- do not connect the fan to the ceiling
- avoid backflow of air through the chimney
- ventilation grid should be installed to prevent water
and insects from entering
- if you do not use it for a long time, it is recommended
to disconnect the device from the power supply
- a constant supply of fresh air to the room must be ensured
- do not use the fan in a hazardous environment (i.e. near
flammable materials, in a heavily polluted one) or in a place
where it could be exposed to direct contact with water
- fan working temperature range is from -15oC to 40oC
- some elements of the fan become hot and touching them
may cause burns
- unusual sounds during fan operation may indicate
a malfunction
- failure to comply with the guidelines contained in this
manual may result in damage to health or pose a threat
to the life of the user
Maintenance
Maintenance of the device should be carried out
depending on the working conditions, but not less than
once a year.
Before starting any maintenance operations, disconnect
the fan from the power supply and secure it against
uncontrolled turning on.
In order to clean the fan it is necessary to:
- disassemble the device (remove the panel, housing, rotor)
- wash all parts with a damp cloth, taking care not to wet
engine
- never use water at temperatures higher than 60oC,
gasoline, benzene, thinner or any other organic solvent
- dry all elements thoroughly
- re-install the fan
- connect the fan to power supply
Wiring diagram
Device versions
1) With time switch (index "T" in the index)
The fan with timer switches on when it receives power.
Then the device will continue operation for 1 –30 minutes
(depending on the settings).
The time can be adjusted with appropriate knob.
2) With motion sensor (with "MS" index)
The fan with the motion detection sensor switches
on automatically when the sensor detects motion
in the sensor's operating area (semicircle with diameter
5 m), then it works until the movement stops
and subsequently continues operation according
to the time set on the time switch (so-called delay time).
Timer settings can be adjusted in the range of 1 - 30
minutes.
The time can be adjusted with appropriate knob.
3) With a chain ("PC" in the name)
The fan equipped with a chain that allows manual switching
on / off of the device.
Terms of warranty
I. Reventon Group Sp. z o.o. [Ltd.] is the supplier of the fans
and provides 24-month warranty period CODE series.
II. The terms of warranty are valid from purchasing
the device (the date issuing a document confirming
the purchase of the device) but not further than 30 (thirty)
months from leaving the supplier’s warehouse.
III. The claim will be considered only if the document
confirming the purchase (eg. copy of the invoice)
and description of the fault is provided.
IV. The supplier is committed to consider the claim within
14 working days since the date of reporting (i. e. day when
documents given in point III are provided).
V. Under the guarantee the supplier provides a repairment,
replacement or refund for the defective device within
a specified time limit.
VI. Warranty does not cover mechanical damage,
degradation of the quality related with time passing
and defects resulting from improper exploitation /
maintenance or arbitrary repairs and modifications.
If there is any of the above, you will be charged
for transport and / or repairs.
VII. The supplier do not cover the dismantling / mantling
costs.
VIII. All correspondence should be send to the following
address: Reventon Group Sp. z o.o., 556 Wyzwolenia
Street, 43-340 Kozy, Poland or on e-mail:
serwis@reventongroup.eu.
The supplier Reventon Group Sp. z o. o. reserves the rights
to make changes in the technical data.

This manual suits for next models

3

Other REVENTON Fan manuals

REVENTON VELO Silver Series User manual

REVENTON

REVENTON VELO Silver Series User manual

REVENTON REGO Series User manual

REVENTON

REVENTON REGO Series User manual

REVENTON TORNADO Series Guide

REVENTON

REVENTON TORNADO Series Guide

REVENTON HC-3S Guide

REVENTON

REVENTON HC-3S Guide

REVENTON DTR HC-3S Guide

REVENTON

REVENTON DTR HC-3S Guide

REVENTON DTR Guide

REVENTON

REVENTON DTR Guide

Popular Fan manuals by other brands

Cromtech AP110002 Operation & instruction manual

Cromtech

Cromtech AP110002 Operation & instruction manual

Mitsubishi Electric LGH-25RVX-E installation instructions

Mitsubishi Electric

Mitsubishi Electric LGH-25RVX-E installation instructions

Hunter Ernest Hemingway Series owner's manual

Hunter

Hunter Ernest Hemingway Series owner's manual

Hunter 21978 owner's manual

Hunter

Hunter 21978 owner's manual

Helios HygroBox KWL Series Installation and operating instructions

Helios

Helios HygroBox KWL Series Installation and operating instructions

Progress Lighting P250020 installation manual

Progress Lighting

Progress Lighting P250020 installation manual

Honeywell Perfect Window HR150B quick start guide

Honeywell

Honeywell Perfect Window HR150B quick start guide

Kenmore 405.35162510 Use & care guide

Kenmore

Kenmore 405.35162510 Use & care guide

Casablanca W-28 owner's manual

Casablanca

Casablanca W-28 owner's manual

for Living 052-2230-6 instruction manual

for Living

for Living 052-2230-6 instruction manual

urban ambiance UHP9110 instruction manual

urban ambiance

urban ambiance UHP9110 instruction manual

Sygonix 2525730 operating instructions

Sygonix

Sygonix 2525730 operating instructions

Awenta Orbit WXO100R instruction manual

Awenta

Awenta Orbit WXO100R instruction manual

Inspire Teneriffe J36009-XY-1LA SL manual

Inspire

Inspire Teneriffe J36009-XY-1LA SL manual

CFM AXC-ES Specifications

CFM

CFM AXC-ES Specifications

Greenwood Unity CV2SVGIP installation instructions

Greenwood

Greenwood Unity CV2SVGIP installation instructions

Qazqa Fimm instruction manual

Qazqa

Qazqa Fimm instruction manual

Lunos Silvento EC installation manual

Lunos

Lunos Silvento EC installation manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.