REVENTON REGO Series User manual

Duct fan
REGO Series
User Manual
Introduction
Thank you for choosing our product. Reading of this manual
is required for proper use of the device and absolute
observance to its guidelines is fundamental condition
of security.
All users of the device should have free access
to the manual and in case of resale, the instruction must
be attached to the product.
Package contents
- duct fan REGO
- user manual
Transport and storage
The fan should be transported and stored in the original
packaging in a dry place protected from contamination,
until it is installed. Moreover, the fan should be protected
from the shocks.
Application
Axial fans from the REGO series are designed for wall
mounting. They are used for ventilation of small spaces
such as a bathroom or kitchen.
The device in white color version.
.Dimensions (in mm)
MODEL
ØA
ØB
ØC
D
REGO 100
98
104
100
88
REGO 120
123
128
120
88
REGO 150
148
154
150
108
Technical data
MODEL
REGO 100
REGO 120
REGO 150
Maximum aiflow [m3/h]
130
240
320
Maximum compression [Pa]
36
45
60
Voltage [V] / Frequency [Hz]
230/50 - 60
230/50 - 60
230/50 - 60
Rated current [A]
0,072
0,11
0,138
Engine speed [rpm]
2400
2200
2000
Engine power [W]
12
16
18
IP protection degree [-]
X2
X2
X2
Noise [dB(A)]
34
34
35
Installation instructions
In order to accomplish the installation of the device
successfully and enable the safe usage of the fan
in the future, it is essential to follow the instructions in this
manual.
Before installing and connecting the fan, check that it has
not been damaged during transport or storage (breakage,
distortion).
Check whether the technical data on the nameplate
corresponds to the electrical installation parameters.
The device should be mounted on a flat surface.
If irregularities are not found, you can proceed
with the installation as follows:
- connect the power supply according to the wiring diagram
- assemble ventilation ducts, tighten them with clamps
- the ventilation ducts should be carried out in accordance
with the duct manufacturer's instructions and applicable
local regulations
- it is not allowed to make ducts in the way shown below:
- when starting the extraction fan, check the following
problems:
a. the impeller is not working properly
b. strong vibrations or strange noise
- if any of the above flaws is not found, turn off the fan and
mount the junction box
The electrical connection must be in accordance
with the wiring diagram in the terminal box.
Warnings and precautions
During the operation of the device, the following
precautions must be observed:
- before performing any work, the device must
be disconnected from the power supply
- the fan is intended only for ventilation of rooms with small
and medium cubature
- installation height of the exhaust fan min. 2.3 m
- the minimum distance between the fan and the ceiling
is 5 cm
- if you do not use it for a long time, it is recommended
to disconnect the device from the power supply
- a constant supply of fresh air to the room must be ensured
- do not use the fan in a hazardous environment (i.e. near
flammable materials, in a heavily polluted one) or in a place
where it could be exposed to direct contact with water
- fan working temperature range is from -15oC to 40oC
- avoid reverse line in the ducts
- some elements of the fan become hot and touching
them may cause skin burns
- unusual sounds during fan operation may indicate
a malfunction
- failure to comply with the guidelines contained in this
manual may result in damage to health or pose a threat
to the life of the user
Maintenance
Maintenance of the device should be carried out
depending on the working conditions, but not less than
once a year.
Before starting any maintenance operations, disconnect
the fan from the power supply and secure it against
uncontrolled switching on.
In order to clean the fan it is necessary to:
- disassemble the device
- wash all parts with a damp cloth, taking care not to wet
engine
- never use water at temperatures higher than 60oC,
gasoline, benzene, thinner or any other organic solvent
- dry all elements thoroughly
- re-install the fan
- connect the fan to power supply
Wiring diagram
Terms of warranty
I. Reventon Group Sp. z o.o. [Ltd.] is the supplier of the fans
and provides 24-month warranty period REGO series.
II. The terms of warranty are valid from purchasing
the device (the date issuing a document confirming
the purchase of the device) but not further than 30 (thirty)
months from leaving the supplier’s warehouse.
III. The claim will be considered only if the document
confirming the purchase (eg. copy of the invoice)
and description of the fault is provided.
IV. The supplier is committed to consider the claim within
14 working days since the date of reporting (i. e. day when
documents given in point III are provided).
V. Under the guarantee the supplier provides a repairment,
replacement or refund for the defective device within
a specified time limit.
VI. Warranty does not cover mechanical damage,
degradation of the quality related with time passing
and defects resulting from improper exploitation /
maintenance or arbitrary repairs and modifications.
If there is any of the above, you will be charged
for transport and / or repairs.
VII. The supplier do not cover the dismantling / mantling
costs.
VIII. All correspondence should be send to the following
address: Reventon Group Sp. z o.o., 556 Wyzwolenia
Street, 43-340 Kozy, Poland or on e-mail:
serwis@reventongroup.eu.
The supplier Reventon Group Sp. z o. o. reserves the rights
to make changes in the technical data.

This manual suits for next models

3

Other REVENTON Fan manuals

REVENTON TORNADO Series Guide

REVENTON

REVENTON TORNADO Series Guide

REVENTON VELO Silver Series User manual

REVENTON

REVENTON VELO Silver Series User manual

REVENTON DTR Guide

REVENTON

REVENTON DTR Guide

REVENTON DTR HC-3S Guide

REVENTON

REVENTON DTR HC-3S Guide

REVENTON CODE Series User manual

REVENTON

REVENTON CODE Series User manual

REVENTON HC-3S Guide

REVENTON

REVENTON HC-3S Guide

Popular Fan manuals by other brands

Swegon GOLD PX Operation & maintenance instructions

Swegon

Swegon GOLD PX Operation & maintenance instructions

ERA COMFORT 4 operation instruction

ERA

ERA COMFORT 4 operation instruction

Trion Grease Viper Series instructions

Trion

Trion Grease Viper Series instructions

Alora EMIKO instruction manual

Alora

Alora EMIKO instruction manual

Venmar AVS CONSTRUCTO 1.5 user guide

Venmar AVS

Venmar AVS CONSTRUCTO 1.5 user guide

Koenic KTF 121 user manual

Koenic

Koenic KTF 121 user manual

Samsung Fresh Access AN035NSEDAV/AA installation manual

Samsung

Samsung Fresh Access AN035NSEDAV/AA installation manual

WHISPER KOOL XLT Series installation guide

WHISPER KOOL

WHISPER KOOL XLT Series installation guide

Ebmpapst W2G115-AD15-13 operating instructions

Ebmpapst

Ebmpapst W2G115-AD15-13 operating instructions

Pro Breeze PB-F16-US instruction manual

Pro Breeze

Pro Breeze PB-F16-US instruction manual

HAMPTON BAY Minorca owner's manual

HAMPTON BAY

HAMPTON BAY Minorca owner's manual

Ebmpapst G2E146-BF05-29 operating manual

Ebmpapst

Ebmpapst G2E146-BF05-29 operating manual

Ebmpapst A4E350-AF20-05 operating instructions

Ebmpapst

Ebmpapst A4E350-AF20-05 operating instructions

Ebmpapst D4E225-CC07-37 operating instructions

Ebmpapst

Ebmpapst D4E225-CC07-37 operating instructions

Ebmpapst K3G400-RJ75-01 operating instructions

Ebmpapst

Ebmpapst K3G400-RJ75-01 operating instructions

Tecnosystemi Apply.co 12501000 user manual

Tecnosystemi

Tecnosystemi Apply.co 12501000 user manual

Honeywell HT-216E operating instructions

Honeywell

Honeywell HT-216E operating instructions

Air King AK927 Specifications

Air King

Air King AK927 Specifications

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.