5. PRECAUTIONS & WARNINGS
4. INSTALLATION INSTRUCTIONS
4.1 CONNECTION OF THE DEVICE TO THE HYDAULIC SYSTEM
4.2 CONNECTION OF THE DEIVCE TO THE ELECTRICAL SYSTEM
1.INTRODUCTION
1.1 PRECAUTIONS
1.2 TRANSPORT
1.3 PACKAGE CONTENT
1.4 USE
2. DEVICE CHARACTERISTICS
2.1 INTERNATIONAL PROTECTION DEGREE IP
2.2 CONSTRUCTION AND PRINCIPLE OF OPERATION
2.3 ANTI-CORROSION COATING
2.4 DEVICE DIMENSIONS
2.5 DEVICE TECHNICAL DATA
3. ASSEMBLY
3.1 GENERAL PRINCIPLES
3.2 ROTATING MOUNTING BRACKET
must be followed.
the producer Reventon Group sp. z o. o. [Ltd.]. The producer reserves the rights
with the authorized for repair person or the supplier. During the installation,
2.1INTERNATIONAL PROTECTION DEGREE IP
ź first characteristic digit - specifies protection of the device against access
1. INTRODUCTION
8. TERMS OF WARRANTY
it is necessary to carry the device by two people. In case of any damages please fill
in the damage report in presence of the supplier.
any damages. During the transport, it is needed to use the proper equipment,
7. CONNECTION SCHEMES
- operation and maintenance manual and warranty card
Determines the tightness of the electrical device (fan motor), which is defied
are responsible for making the installation as instructed in the technical data.
1.1 PRECAUTIONS
1.3 PACKAGE CONTENT
use, service and periodical inspections all regulations and safety rules
6. CONTROLS
the correct usage and safety. In case of any doubts please contact directly
to make changes to the technical documentation without previous notice.
Reventon Group sp. z o. o. [Ltd.] is not responsible for the damages which occur
due to improper installation, not keeping the device in repair or using the device
out of line. The installation should be carried out by the professional installers,
who possess the qualifications to install these types of devices. The installers
The buyer and the user of the air water heater Reventon Group brand should
read carefully the following instructions and proceed to the content
recommendations. Proceeding due to the following instruction guarantees
- heater
1.4 USE
Reventon Group Farmer HCF heating devices are designed for heating or cooling
surfaces in which aggressive conditions prevail, i.e. high content of acids,
ammonia and high concentration of dust. However, heaters should not be used in
highly corrosive environments for aluminum, copper and steel. The devices
should also not be installed in rooms where they would be exposed to the high
humidity or direct water action, exceeding the fan's resistance to water
penetration (see IP protection degree).
2. DEVICE CHARACTERISTICS
Thank you very much for purchasing air water heater FARMER HCF. We would
like to congratulate you on excellent choice. Please read and keep this manual.
In case of unserviceable please plug out the device and contact
During the acceptance of goods, it is needed to check the device to exclude
1.2 TRANSPORT
by two digits:
to dangerous parts as well as against penetration of solids
ź second characteristic digit – determines the resistance of the engine
to the water ingress, its waterproofness
ENG
TECHNICAL DOCUMENTATON
2.2 CONSTRUCTION AND PRINCIPLE OF OPERATION
Fan has to ensure air flow through the exchanger. It has a single- and three phase
motor with the following parameters: protection degree IP54, rate current
It has an excellent sound and thermal insulation properties. Moreover, material
Farmer HCF IP66
Fan motors of the Farmer HCF series have following IP:
Farmer HCF IP54-3S
is environmentally friendly and "green", i.e. 100% recyclable.
the air stators to achieve the needed direction of the air flow. There are also
versions with confusor (increased airflow range) or with diffuser 360° (better
mixing of supplied and room air).
a double row heat exchanger.
0.7-1.08 A (depending on the operating mode). Diameter of the fan is 450 mm.
Axial blowing fan IP54 (Farmer HCF IP54-3S): made of galvanized steel.
Rotating mounting bracket (optional equipment): enables the device
5 - protection against access to hazardous parts by wire with a diameter of 1 mm
or more and against dust in quantities which might impair the proper functioning
of the equipment;
6- protection against access to hazardous parts by wire with a diameter of 1 mm
or more and against dust (total dust tightness);
Axial blowing fan IP66 (Farmer HCF IP66): made of powder coated steel. Fan
has to ensure air flow through the exchanger. It has a single phase motor
Heating coil: made of copper and aluminum. It is covered by epoxy coating.
Supplied by distribution medium (heating or cooling), which circulates through
the coil and releases or extracts heat from the air. The coil has the following
technical parameters: the maximum temperature of the heating factor is 120°C;
maximum pressure 1.6 MPa; headers diameter ¾”. Farmer HCF series have
to be installed in several configurations (depending on the requirements)
with the following parameters: protection degree IP66, rated current 2.7A.
Diameter of the fan is 450 mm.
Casing: made of expanded polypropylene (EPP). This material is characterized by
low density (light weighted) and high chemical and physical resistance.
4 – protection against splashes of the water from any direction.
5 – protection against stream of the water (100 l/min) from any direction
Air stators: made of polypropylene PP. It is possible to adjust manually
and the unit to be rotated in a horizontal plane.
2.3 ANTI-CORROSION COATING
The heat exchangers from FARMER series heaters are covered with an additional
epoxy coating. It protects metal surfaces against the negative influence of humid,
salt and acid environments.
The table below provides information about the resistance of the coating against
various compounds:
Trichlorethylene Excellent/Good
Methyl Ethyl Ketone (MEK) 100 ppm
Acids (2% HCL, 2% H2SO4) Excellent/Good
Excellent/Good
Steam (
121
0
C/ 30 min) Excellent
COMPOUND IMMUNITY
Salt spray