Revitive IX User manual

PLEASE READ THE USER’S
MANUAL CAREFULLY BEFORE
USING THIS PRODUCT
USE ONLY AS DIRECTED
If symptoms persist, consult
your Health Care Professional
Model number: RIX
User’s manual
1718_IFU01_7244012.indd 1 27/03/2015 10:04

1718_IFU01_7244012.indd 2 27/03/2015 10:04

3
Table of contents
What is inside the box? 4
Parts and Controls 5
Introduction to REVITIVE 6
Indications for use 6
How REVITIVE works 6
Important Safeguards 7
Contraindications 7
Warnings, Cautions and Adverse Reactions 7
Instructions for use 11
How long should I use REVITIVE? 11
Step 1: Setting up REVITIVE for the first time 11
Step 2: Setting up REVITIVE for use 13
Step 3: Using the foot pads 15
Step 4: Using the body pads 18
Step 5: Using the foot pads and body pads at the same time 24
Step 6: Cleaning and storing 25
Replacing the batteries 25
Replacing the body pads 25
About the REVITIVE Remote Control 25
Troubleshooting 26
Technical Specifications 28
Symbols 30
Warranty 31
1718_IFU01_7244012.indd 3 27/03/2015 10:04

4
R
A
B
F
What is inside the box?
Upon opening the carton, please check that the following components
are provided. If you think anything is missing, contact us toll-free on our
helpline number 877-260-3114 or visit www.revitive.com
G
AC/DC power adapter
REVITIVE
C
D
E
Body pads x 2 Pairs
Body pad cords x 2
Body pad holders x 2
Remote control
AAA batteries x 2
1718_IFU01_7244012.indd 4 27/03/2015 10:04

5
R
L
M
N
H
J
K
M
N
I
L
Carry handle
Control panel/display
Power ON/OFF
Foot pads
AC/DC power adapter socket
Body pad sockets
IsoRockerTM
Time control – /+
Foot pad intensity control – /+
Body pad intensity control – /+
Controls of REVITIVE
Remote control
Control panel
Parts and Controls of REVITIVE
Parts of REVITIVE
1718_IFU01_7244012.indd 5 27/03/2015 10:04

6
Introduction to REVITIVE
INDICATIONS FOR USE
REVITIVE is intended:
• To temporarily increase local blood circulation in healthy
leg muscles
• For temporary relief of pain associated with sore and aching
muscles in the shoulder, waist, back, upper extremities
(arms) and lower extremities (legs) due to strain from exercise
or normal household duties
• To stimulate healthy muscles in order to improve and facilitate
muscle performance
HOW REVITIVE WORKS
REVITIVE delivers electrical stimulation to your feet via a pair of cushioned
foot pads, while you are seated. The electrical stimulation causes muscles
in your calf and foot to contract, which helps to increase circulation in your
lower legs.
REVITIVE has been developed so that it is comfortable for you to use.
It features an IsoRocker (patent pending) that allows for natural ankle
movement when applying the electrical stimulation to your feet. Ankle
movement is a key factor in increasing circulation in the lower legs. You can
choose to enable or disable the IsoRocker anytime.
REVITIVE is designed to be easy to use and also comes with a remote
control, which means you do not have to reach down to adjust settings
during use.
REVITIVE can also deliver electrical stimulation to the knees, shoulders,
back or arms. Delivering electrical stimulation to your body at the same
time as your feet is possible with REVITIVE.
Visit www.revitive.com for more information
1718_IFU01_7244012.indd 6 27/03/2015 10:04

7
IMPORTANT SAFEGUARDS
READ ALL INSTRUCTIONS BEFORE USE
WHO SHOULD NOT USE REVITIVE
REVITIVE should not be used by some people.
Do not use if: (contraindications)
• You have a cardiac pacemaker, implanted defibrillator, or other
implanted metallic or electronic device because this may cause electric
shock, burns, electrical interference, or death
• You are being treated for or suspect you have a Deep Vein Thrombosis
(DVT)
• You are pregnant
WHO SHOULD CHECK WITH THEIR DOCTOR BEFORE
USING REVITIVE
Warnings
•Consult with your doctor before using this device if:
• You are in the care of a doctor
• You have a history of heart problems because the device may cause
lethal rhythm disturbances to the heart in susceptible individuals
• You are experiencing cramping leg pain that occurs during walking
• You have slow healing wounds
• You have loss of feeling in the hands or feet
• You have had medical or physical treatment for your pain
• You have suspected or diagnosed heart disease
• You have suspected or diagnosed epilepsy
1718_IFU01_7244012.indd 7 27/03/2015 10:04

8
IMPORTANT SAFEGUARDS
Warnings continued
•Do not use the body pads on your head, face, neck or chest.
There is a chance that serious health problems, and in rare cases death,
may be caused by using the body pads on your head, face, neck or chest.
• There is a chance that using the body pads on your head, face or
neck may cause closure of the airway, difficulty in breathing, or
adverse effects on heart rhythm or blood pressure.
• The introduction of electrical current into the chest may cause
rhythm disturbances to your heart, which could be lethal
• Use body pads only on parts of your body as directed in this guide
•Do not apply body pads directly:
• on open wounds or rashes, swollen, red, infected, or inflamed areas
or skin eruptions (such as phlebitis, thrombophlebitis, varicose veins)
• on or close to, cancerous lesions/tumors
• on areas treated with radiotherapy (within the past 6 months)
• on reproductive organs
When Not to Use REVITIVE
There are times you should not use REVITIVE. Do not use REVITIVE:
•with electronic monitoring equipment (such as cardiac monitors, ECG
alarms), which may not operate properly when the electrical
stimulation device is in use.
•when you are in the bath or shower.
•while you are sleeping.
•while you are driving, operating machinery, or during any activity in
which electrical stimulation can put you at risk of injury.
1718_IFU01_7244012.indd 8 27/03/2015 10:04

9
Cautions
•Be careful when applying stimulation:
• over areas of skin that lack normal sensation - be careful not to
overstimulate the area.
• over the abdomen during menstruation.
• after recent surgical procedures as stimulation may disrupt your
healing process.
• if you are likely to bleed internally, such as following an injury or
fracture – use a low intensity and/or shorter time to avoid over-
stimulation.
• after a long period of immobility or inactivity – use a low intensity
and shorter time to avoid over-stimulation or muscle fatigue.
•It is possible REVITIVE may reduce the sensation of pain that
would normally act as a warning of an underlying problem.
•If your pain does not improve, gets worse or continues for more than 5 days,
stop using the device and talk to your doctor.
•The long-term effects of electrical stimulation are unknown.
•Keep this device out of the reach of children.
•Use the REVITIVE only with the body pads, cords, and accessories
recommended by the manufacturer.
• Check body pads, cords and cables periodically for damage.
• Ensure connectors are pressed together until no gap is between them.
Leaving a gap may cause discomfort.
IMPORTANT SAFEGUARDS
1718_IFU01_7244012.indd 9 27/03/2015 10:04

10
•Do not open the REVITIVE or repair it yourself. This will invalidate
your warranty and may cause serious harm.
•In the unlikely event your REVITIVE malfunctions, disconnect it from the
power source and contact your nearest authorized agent.
•The REVITIVE has passed the required tests for EMI, it may still be affected
by excessive emissions and/or may interfere with more sensitive equipment.
•It has been reported that some universal remote control devices can change
the settings on REVITIVE if used during a REVITIVE treatment. If this should
occur, simply adjust the time or intensity settings on Revitive using the
REVITIVE Control Panel/Remote Control.
Adverse reactions
•Do not use body pads after their expiration date. There is a chance you
may experience skin irritation or burns under the body pads.
•There is a chance you may experience skin irritation or
hypersensitivity due to the electrical stimulation.
•If you experience adverse reactions, stop using REVITIVE and talk
with your doctor.
SAVE THESE INSTRUCTIONS
1718_IFU01_7244012.indd 10 27/03/2015 10:04

11
Instructions for use
STEP 1:
SETTING UP REVITIVE FOR THE FIRST TIME
aRemove all parts from the carton:
•
AC/DC power adapter
• REVITIVE
• Body pads
•
Body pad cords
• Body pad holders
•
Remote control
• AAA batteries x 2
See What is inside the Box? pages 4-5 to help identify the parts
Hint: the AC/DC power adapter is supplied in a small, white labelled box
situated to one side as you open the carton
Note: If something is missing, contact our helpline toll-free on
877-260-3114 or visit www.revitive.com
How long should I use REVITIVE?
Do not use REVITIVE more than 6 sessions of 30
minutes (or the equivalent) per day. This may result in
muscle fatigue.
It is recommended to use REVITIVE for 20-30 minutes
per day.
1718_IFU01_7244012.indd 11 27/03/2015 10:04

12
bLocate the remote control.
cLocate the back cover of the remote control.
dPull the latch to open the cover.
e Insert the batteries.
Make sure you insert the batteries correctly with the flat
end (negative (-) end) placed against the spring in each
slot.
fPress the cover onto the back of the remote to close it.
Before you use REVITIVE for the first time, read the
Warnings and Cautions on pages 7-11. If in doubt,
consult your doctor before using the product.
Instructions for use
1718_IFU01_7244012.indd 12 27/03/2015 10:04

13
STEP 2:
SETTING UP REVITIVE FOR USE
aTurn the device over so that you can see the
IsoRocker
• The IsoRocker allows REVITIVE to rock
while stimulating your legs and feet.
• REVITIVE will begin rocking on the IsoRocker
once muscle contractions are strong enough.
• When the IsoRocker feature is disabled
REVITIVE will be inclined, but will not rock
during use.
bIf you want to use the IsoRocker leave the IsoRocker
in place on the bottom of REVITIVE, as shown.
cIf you do not want to use the IsoRocker
• Pull the IsoRocker bar on the bottom of
REVITIVE.
You may have to pull hard.
1718_IFU01_7244012.indd 13 27/03/2015 10:04

14
• Pull the IsoRocker bar back until it clicks open as
shown.
• To re-enable the IsoRocker, pull the IsoRocker bar
and press into place on the bottom of REVITIVE.
Instructions for use
R
R
R
R
R
dLocate the AC/DC power adapter.
ePlug the small end of the power cord into the opening on
the side of the REVITIVE.
fPlug the power adapter into the nearest electrical outlet.
R
R
R
R
R
1718_IFU01_7244012.indd 14 27/03/2015 10:04

15
STEP 3:
USING THE FOOT PADS ( )
a Get into a comfortable seated position.
For best results sit with your knees and ankles at right
angles to your body.
b Place REVITIVE on the floor in front of you.
Never stand on the REVITIVE unit.
REVITIVE is designed to be used while seated.
c Place both bare feet on the foot pads.
Make sure you remove all footwear, including socks/
stockings.
d If desired, apply a moisturizing lotion to the soles of
your feet.
Hint: Applying a moisturizing lotion to the soles of
the feet before using REVITIVE can help improve the
delivery of electrical stimulation.
ePress the power button on the REVITIVE or
remote control to turn REVITIVE on.
You will hear a beep and the control panel settings
light up.
To turn off REVITIVE at any time during operation, press
the power button on the REVITIVE or remote control.
R
R
R
R
R
R
R
R
R
R
Sit with
both bare feet
on the foot pads
1718_IFU01_7244012.indd 15 27/03/2015 10:04

16
Instructions for use
fSet the time for the number of minutes you want to use
REVITIVE.
You can use the buttons on the control panel or remote
control.
Press the (+) button to increase the time.
Press the (–) button to decrease the time.
The default time is 30 minutes. You can set the timer for
up to 60 minutes.
gPress the foot pad intensity (+) button one time to start
stimulation.
You can set the intensity between 1-99.
hPress the foot pad intensity (+) button until it is at the
desired level.
Use an intensity that provides you with strong but
comfortable muscle contraction and note that the
intensity required may vary from day to day.
It is normal to feel tingling or varying sensations in
your calf muscles.
R
R
R
R
R
R
R
R
R
R
1718_IFU01_7244012.indd 16 27/03/2015 10:04

17
If you feel pain or discomfort:
• Remove one or both feet from the foot pads to
stop the stimulation.
• Lower the intensity of the foot pads using the
footpad intensity - button on the control panel or
remote control before replacing your feet on
REVITIVE.
REVITIVE does not vibrate.
iThe time control/display will start to count down
in minutes as REVITIVE cycles through its program.
jWhen REVITIVE times out, the time display reads (00)
and you will hear three beeps.
k The REVITIVE switches itself off automatically.
1718_IFU01_7244012.indd 17 27/03/2015 10:04

18
STEP 4: USING THE BODY PADS ( )
REVITIVE comes with two pairs of reusable (up to 20-30 applications)
body pads that can be used to deliver electrical stimulation to the knees,
shoulders, back or arms.
Do NOT use the body pads on your head, face, neck or chest.
There is a chance that serious health problems, and in rare cases death,
may be caused by using the body pads on your head, face, neck or chest.
• There is a chance that using the body pads on your head,
face or neck may cause closure of the airway, difficulty in
breathing, or adverse effects on heart rhythm or blood
pressure.
• The introduction of electrical current into the chest may cause
rhythm disturbances to your heart, which could be lethal.
• Use body pads only on parts of your body as directed in this guide.
Refer to the Warnings on page 8 before using the body pads.
Instructions for use
Head/Face
Neck
Chest
✖
✖
✖
DO NOT PLACE BODY PADS ON YOUR:
✖
1718_IFU01_7244012.indd 18 27/03/2015 10:04

19
a Select the area you wish to apply electrical stimulation. If you wish
to treat two areas at the same time, apply a pair of body pads to
each area.
Example placements are shown below:
b Clean and dry the area where you will place the body pads.
Thigh Knee
Back of
Shoulder
Upper Back
Lower Back
✔
✔
✔
✔
✔
✔
1718_IFU01_7244012.indd 19 27/03/2015 10:04

20
c Make sure REVITIVE is switched off. If the control
panel is still illuminated, press the power button and
turn REVITIVE off.
d Attach the ends of the body pads to the body pad
cords. If you are using both pairs of body pads, repeat
this step for the remaining body pads.
Press connectors until no gap is between them.
Leaving a gap may cause discomfort.
ePlug the other end of the body pad cord into either of
the openings on the side of REVITIVE.
If you are using both pairs of body pads, repeat this
step for the remaining body pad cord.
fFirst time use only: remove the plastic liner from the
body pads, by peeling it off carefully, then discard.
Instructions for use
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
1718_IFU01_7244012.indd 20 27/03/2015 10:04
Table of contents