Rexall RX810 User manual

Model #: RX810
Instruction Manual
10.17.18

Table of Contents
1. Introduction
1.1 Features
1.2 Important Information
1.2A Safety Information
1.2B Care of the Device
1.2C Comparing Readings to Other Blood Pressure Devices
1.2D Calibration
1.3 About Blood Pressure
1.4 Normal Blood Pressure Values
1.5 Common Blood Pressure Questions and Answers
2. Getting Started
2.1 About the Blood Pressure Monitor
2.2 About the LCD Screen
2.3 Inserting the Batteries
2.4 Using the AC/DC Power Adapter
3. Using the Device
3.1 Select the User
3.2 Setting the Time, Date and Year
3.3 Obtaining Accurate Measurements
3.3A Tips on Taking Accurate Measurements
3.3B Common Sources of Errors
3.3C Fitting the Cuff
3.4 Measuring Your Blood Pressure
3.5 HypertensionClassicationIndicator
3.6 Viewing Previously Recorded Values
3.7 Clear Measurements From Memory
3.8 Discontinuing a Measurement
4. Error Messages / Malfunctions
5. Care and Maintenance
6. Lifetime Guarantee
7. TechnicalSpecications
Instruction Manual

1. Introduction
Designed for convenient and easy operation, the RexallTM/MC Premium Blood Pressure Monitor provides a simple,
yet accurate method to measure your blood pressure.
Your blood pressure is an important parameter that can be used to monitor your health. This device enables you
to monitor your blood pressure regularly, and maintain a record of your blood pressure measurements. You can
then use this record to assist your physician in diagnosing and maintaining a healthy blood pressure level.
1.1. Features
The monitor is a fully automatic digital blood pressure measuring device with a unique fuzzy logic technology
and a large LCD screen. It can store up to 90 blood pressure readings for each of the 2 users.
It provides a fast and reliable measurement of systolic and diastolic blood pressure as well as heart rate using
the oscillometric measurement method.
• Detects Irregular Heartbeat
• Hypertension Classication Indicator displays the range between which your blood pressure values lie.
• Memory Feature can store 90 blood pressure readings for each of the 2 users with time and date.
The blood pressure monitor meets the accuracy requirements of Hypertension Canada and has been tested for
clinical accuracy.
This device is easy to use and has been proven in clinical studies to provide excellent accuracy. Before using the
blood pressure monitor, read this instruction manual carefully and keep it in a safe place.
1.2 Important Information
Refer to the following sections to learn about important safety instructions and how to take care of the
RexallTM/MC Premium Blood Pressure Monitor.
1.2A Safety Information
• Self-measurement means control, not diagnosis or treatment. Your values must always be discussed with
your doctor or a physician who is familiar with your family history.
• If you are undergoing medical treatment and receiving medication, consult your doctor to determine the
most appropriate time to measure your blood pressure. Never alter the dosages of any medication without
direction from your doctor.
• Your blood pressure depends on several factors, such as age, gender, weight and physical condition. It also
depends on the environment and your state of mind at the time of measurement. In general, your blood
pressure is lower when you are asleep and higher when you are active. Your blood pressure may be higher
when recorded at a hospital or a clinic and may be lower when measured in the relaxing comfort of your
home. Due to these variations, we recommend that you record your blood pressure regularly at home as
well as at your doctor’s clinic.
• Try to record your blood pressure regularly at the same time of the day and under the same conditions. This
will help your physician detect any extreme variations in your blood pressure and thus treat you accordingly.
• Morning Hypertension (> 135 / 85 mm Hg): Recently, several studies have identied elevated cardiovascular
risks (heart failure, stroke, angina) associated with “morning hypertension”. There is a typical rise in blood
pressure during the physiological changes from sleep to arising for the day.

• The ideal time to measure your blood pressure is in the morning just after you wake up, before breakfast
and any physical activity, and in the absence of the urge to urinate. If this is not possible, try to take the
measurements later in the morning, before you start any physical activity. Relax for a few minutes before
you record your blood pressure.
• Your blood pressure increases or decreases under the following circumstances:
Blood pressure is higher than normal:
— when you are excited, nervous, or tense
— while taking a bath
— during and after exercise or strenuous physical activity
— when it is cold
— within one hour after meals
— after drinking tea, coffee, or other caffeinated drinks
— after smoking tobacco
— when your bladder is full
Blood pressure is lower than normal:
— after consuming alcohol
— after taking a bath
• The pulse display is not suitable for checking the frequency of heart pacemakers.
• If you have been diagnosed with a severe arrhythmia or irregular heartbeat, vascular constriction, liver
disorder or diabetes, have a cardiac pacemaker, or are pregnant, measurements made with this instrument
should only be evaluated after consultation with your doctor.
• Take care while handling the batteries in the device. Incorrect usage may cause battery uid leakage.
To prevent such accidents, refer to the following instructions:
— Insert batteries with the correct polarity.
— Turn off power after use. Remove and store the batteries if you are not planning to use the
device for an extended period of time.
— Do not mix different types, brands, or sizes of batteries. This may cause damage to the product.
— Do not mix old and new batteries.
— Remove batteries and dispose of them according to the proper regulations in your area.
— Do not disassemble batteries or expose them to heat or re.
— Do not short circuit the batteries.
— Do not use rechargeable batteries.

1.2B Care of the Device
For prolonged life of your blood pressure monitor, note the following instructions:
• Do not drop or bang the unit. Prevent sudden jerks, jars or shocks to the device to prevent damage.
• Do not insert any foreign objects in any device openings or vents.
• Do not disassemble the unit.
• If the unit has been stored at very low or freezing temperatures, allow the unit to reach room temperature
before using it.
• Do not store the unit in direct sunlight, high humidity or in places with a lot of dust.
• Clean the device with a soft dry cloth. Do not use gasoline, thinner or similar solvents.
Carefully remove spots on the cuff with a damp cloth and soap. Do not wash the cuff.
1.2C Comparing Readings to Other Blood Pressure Devices
Many questions arise when two blood pressure devices are compared in an effort to check accuracy. An accurate
comparison requires repeatable measurements under the same conditions, and signicant time is required to
reduce naturally occurring blood pressure variability during the test. For proper comparisons, the subject should be
seated comfortably with feet at on the oor, and have rested for 5 minutes before the rst reading to allow blood
pressure levels to stabilize. The patients back, elbow and forearm should be supported, and the middle of the
cuff should be at the level of the right atrium. There should be no talking or moving during the measurement and
if comparing to an aneroid gauge or mercury column, observers should avoid parallax and be careful not to round
measurements.
The most accurate way to compare devices is to take two readings at the same time. However most people and
doctor’s ofces do not have the equipment necessary to measure blood pressure from two devices simultaneously.
To take sequential measurements properly requires a pair of initial measurements to determine the subjects blood
pressure level: rst with the reference equipment, followed by 60 seconds, then with the monitor-under-test.
The actual accuracy test requires three pairs of measurements with 60 seconds between measurements. These
measurements are averaged and a comparison can be made. Since most people tend to relax and their blood
pressure falls with subsequent measurements, following this protocol reduces these natural changes in blood
pressure levels. The standard technical error of both consumer and professional devices is normally ±3 mmHg, so a
discrepancy of 6 mmHg is acceptable even when the devices are working within their specications.
Any comparisons without following the procedures described above will not yield reliable results. In addition, to
do an accuracy test properly the reference device must also be tested to a known reference to conrm its accuracy,
prior to being used as the reference for comparisons.
1.2D Calibration
Digital blood pressure monitors do not require recalibration. If the unit turns on and does not display an error
code, the product is working properly. In extremely rare cases, the cuff may have developed a pin-hole leak, or the
gasket where the cuff connector enters the monitor may not have a proper seal; both of these leaking air issues
will potentially cause errors in accuracy, but otherwise the product will work accurately without drifting out of
calibration.

1.3 About Blood Pressure
Your blood pressure level is determined in the circulatory center of your brain. Your nervous system allows your
body to adapt or alter blood pressure in response to different situations. Your body alters your pulse or heart rate
and the width of blood vessels through changes in muscles in the walls of blood vessels.
Your blood pressure reading is highest when your heart pumps or ejects blood. This stage is called your systolic
blood pressure.
Your blood pressure is lowest when the heart rests (in between beats). This is called your diastolic blood
pressure.
It is critical to maintain blood pressure values within a “normal” range in order to prevent cardiovascular
diseases. Increased blood pressure values (various forms of hypertension) have associated long- and medium-
term health risks. These risks concern the arterial blood vessels of your body, which are endangered due to
constriction caused by deposits in the vessel walls (arteriosclerosis). A decient supply of blood to important
organs (heart, brain, muscles) can be the result. Furthermore, with long term increased blood pressure values,
the heart will become structurally damaged.
There are many different causes of the appearance of high blood pressure. We differentiate between common
primary (essential) hypertension, and secondary hypertension. The latter group can be attributed to specic
organic malfunctions. Please consult your doctor for information about the possible origins of your own
increased blood pressure values.
1.4. Normal Blood Pressure Values
Blood pressure is too high when measuring at home and you have rested, the diastolic pressure is above
85 mmHg or the systolic blood pressure is over 135 mmHg. If you obtain readings in this range, consult your
doctor immediately. High blood pressure values over time can damage blood vessels, vital organs such as the
kidney, and your heart.
With blood pressure values that are too low (i.e., systolic values under 105 mmHg or diastolic values under
60 mmHg), consult with your doctor.
Systolic Diastolic Comment
Below 120 Less than
80 This range is considered “Normal” and ideal
120 – 139 80 – 89
This range is considered “Pre-hypertension”: Discuss with your health
care professional. Lifestyle modications maybe required to avoid
advancing into hypertension.
140 – 159 90 – 99
This is in the hypertension range. Discuss with your health care
professional. Medication(s) and lifestyle modications are typical
treatments.
160 and
higher 100 + Discuss with your medical professional, medication(s) and lifestyle
modications are necessary to control your hypertension
Adopted From: Understanding and Managing your blood pressure; Hypertension Canada.

Note: A diagnosis of high blood pressure must be conrmed with a medical professional. A
doctor should evaluate any unusual blood pressure readings. Additionally, lower targets may
be appropriate for some populations such as African-Americans, the elderly, or patients with
underlying issues such as diabetes mellitus or chronic kidney disease.
Important for Canadians:
* Hypertension measured at home ≥135/85
* Hypertension measured at a physician’s ofce ≥140/90
* Hypertension measured at a physician’s ofce for a diabetic patient ≥130/80
1.5 Common Blood Pressure Questions and Answers
a) Why is my blood pressure reading always different?
Your blood pressure changes constantly. It is quite normal for blood pressure to uctuate signicantly
(50 mmHg to 60 mmHg) throughout the day. Blood pressure is normally lowest at night, but increases during
waking hours when the stress and activities of everyday life are highest.
mmHg
AM Time PM
40
50
60
70
80
90
100
110
120
130
140
150
160
170
8.00 10.00 12.00
Typical 24 - Hours Rhythm
14.00 16.00 18.00 20.00 22.00 24.00 2.00 4.00 6.00 8.00
systolic blood pressure
diastolic blood pressure
Your blood pressure also increases and decreases under the following circumstances
Blood pressure is higher than normal:
• when you are excited, nervous, or tense
• while taking a bath
• during and after exercise or strenuous physical activity
• when it is cold
• within one hour after meals
• after drinking tea, coffee, or other caffeinated drinks
• after smoking tobacco
• when your bladder is full
Blood pressure is lower than normal:
• after consuming alcohol
• after taking a bath

b) Why is the doctor’s reading different from the reading taken at home?
Your blood pressure can vary due to the environment (temperature, nervous condition). When measuring
blood pressure at the doctor’s ofce, it is possible for blood pressure to increase due to anxiety and tension.
c) Why should I monitor blood pressure at home?
One or two readings will not provide a true indication of your normal blood pressure. It is important to take
regular, daily measurements and to keep records over a period of time. This information can be used to
assist your physician in diagnosing and preventing potential health problems.
2. Getting Started
2.1 About the Blood Pressure Monitor RX810
This section describes the various components of the monitor:
Cuff Socket
SET Button
Memory Button
Wide Range Cuff
Cuff Connector
AC/DC Adapter Socket
START / STOP Button
Item Function
LCD Screen Recorded blood pressure, heart rate and time are displayed here.
AC/DC Socket Connect to adapter.
Memory Button Press to view the previously recorded data or to adjust the date and time.
Start/Stop Button Press to start or stop recording your blood pressure.
Set Button Press to set current date and time or to change the user.
Cuff Socket Connect to the upper arm cuff here and place the cuff around your arm to
measure your blood pressure.
Battery Compartment Insert the four “AA” batteries here.
Arm Cuff Wide range cuff for arm circumference 23-43 cm / 9.4”-17”.
Battery Compartment
(Underneath)

2.2 About the LCD Screen
The LCD screen displays the systolic and diastolic blood pressure measurements along with your heart rate. It
also displays previously recorded measurements, the date and time, when the appropriate button is pressed.
AM
M D PM
User
Year / Month / Date / Time
Systolic Blood Pressure
Diastolic Blood Pressure
Heartbeat During
Measurement
Memory Times
Memory
Irregular Heartbeat
Hypertension
Classication Indicator
Low Battery
Pulse
2.3 Inserting the Batteries
Follow these steps to insert the four “AA” batteries in the device.
1. Open the battery compartment cover in the direction shown.
2. Insert the four “AA” batteries with the correct polarity as indicated.
3. Replace the battery compartment cover.
Attention!
• After the battery warning appears, the device is blocked until the batteries have
been replaced.
• Please use “AA” Long-Life or Alkaline 1.5V batteries.
• If the blood pressure monitor is left unused for long periods, please remove the
batteries from the device.
• Do not mix old and new batteries. Do not mix alkaline, standard (carbon-zinc) or
rechargeable batteries.
2.4 Using the AC/DC Power Adapter
You may also operate this monitor using the included AC/DC adapter. Use
only the included adapter to avoid damaging the unit.
1. Ensure that the AC/DC adapter and cable are not damaged.
2. Plug the adapter cable into the AC/DC Adapter port on the top of the
blood pressure monitor.
3. Plug the adapter into your electrical outlet. When the adapter is
connected, no battery current is consumed.

3. Using the Device
This section describes how to get the maximum benet from your blood pressure monitor. Follow the instructions
carefully to get an accurate measurement of your blood pressure and pulse rate.
NOTE: Setting the user, year, month, date and time is one sequential process.
3.1 Select the User
1. Start with the power off, but with batteries or adapter inserted.
2. Press the SET button 1 time, the user will appear in the upper left corner. Use the MEM button to choose
user or
3.2 Setting the Time, Date and Year
1. Immediately after selecting the user, press the SET button, the YEAR will ash. Use the MEM button to
choose the year and press SET to store in the memory.
2. Repeat the same process to set the MONTH by using the MEM button. Press the SET button to store it in the
memory.
3. The same process is repeated to set the DATE. The date will ash and can be changed with the MEM button.
Afterwards, HOURS will begin to ash.
4. TIME; hours, and then minutes can be set following the same procedure by using the MEM buttons. Finish
the process by pressing the SET button and the USER, YEAR, MONTH, DATE, HOUR and MINUTES will all be
stored in the products memory.
NOTE: In order to change any setting you must repeat the process and conrm each setting by pushing the SET button.
3.3 Obtaining Accurate Measurements
Your blood pressure can vary based on numerous factors, physiological conditions, and your surroundings. Follow
these guidelines to obtain accurate and error-free measurements of your blood pressure and pulse rate.
3.3A Tips on Taking Accurate Measurements
In morning before breakfast, 2
hours after dinner, before taking
medication.
Avoid coffee and smoking within the
hour, and no exercise 30 minutes
before measuring.
Do not speak while taking the
measurement.
Sit with legs uncrossed so as not to
restrict blood ow.
Empty bladder (if necessary).
Rest quietly for 5 minutes.
Remain calm and quiet while the
measurement is in process.
Take measurements on the non
dominant arm.
Sit with back supported and
measurement arm resting on a table.
Sit with feet at on the oor.
Ensure that the BP monitor is level
with the heart while the arm is
supported on the table.
Reprinted by permission of BIOS Diagnostics

3.3B Common Sources of Errors
All efforts by the patient to support the arm can increase the blood pressure. Make sure you are in a
comfortable, relaxed position and do not activate any of the muscles in the measurement arm during the
measurement. Use a cushion for support if necessary.
ATTENTION
Comparable blood pressure measurements always require the same conditions with a peaceful
and calm environment. Ensure that you take measurements under the same conditions to obtain an
accurate estimate of blood pressure variation patterns.
• If the arm artery lies considerably lower or higher than the heart, an erroneous value of blood pressure is
measured. Each 15 cm difference in height results in a measurement error of 10 mmHg.
• A loose cuff causes false measurement values.
• With repeated measurements, blood accumulates in the arm, which can lead to false results. Consecutive
blood pressure measurements should be repeated after at least a 15-second pause or after the arm has
been held up in order to allow the accumulated blood to ow away.
3.3C Fitting the Cuff
a) Pass the end of the cuff through the at metal ring so that a loop is formed. The
closure must be facing outward. (Ignore this step if the cuff has already been
prepared).
b) Wrap the cuff around your bare upper left arm. The rubber tube should be on
the inside of your arm extending downward to your hand.
c) Lay the cuff on the arm as illustrated. Make certain that the lower edge of the
cuff lies approximately ¾” to 1” (2 to 3 cm) above the elbow.
Important: The red material on the cuff must lie exactly over the brachial artery
which runs down the inner side of the arm.
d) Tighten the cuff by pulling the end and close the cuff.
e) There should be little free space between the arm and cuff. You should
be able to t 2 ngers between your arm and the cuff. Clothing must
not restrict the arm. If any piece of clothing does, it must be removed.
If the cuff does not t properly, you will get false measurement values.
Measure your arm circumference if you are not sure of proper t.
f) Lay your arm on a table (palm upward) so the cuff is at the same height
as your heart. Make sure the tube is not kinked. You can adjust the level
of your arm by putting a cushion under your arm.
2–3 cm
Left arm
tube

g) Remain seated quietly for at least 5 minutes before you begin the
measurement.
h) For those who cannot put the cuff on the left arm, put it on the right arm as
shown.
i) Consecutive measurements will cause blood accumulation in the lower arm
which will affect the measuring results. To improve reading accuracy, raise
the arm being measured, squeeze and relax your hand several times, then
take another measurement. Another option is to take the cuff off and wait at
least 5 minutes before repeating measurement.
j) If this device was stored in low temperature, it is necessary to leave it in
room temperature for at least 1 hour, otherwise the measurement can be inaccurate.
Comment:
Continue to use the same arm for comparisons. It is not unusual for there to be a difference in blood pressure
between arms.
Comparable blood pressure measurements always require the same conditions (relax for several minutes before
taking a measurement).
3.4 Measuring Your Blood Pressure
After the cuff has been appropriately positioned, the measurement can begin:
1. Press the START/STOP button until all the symbols appear on the screen, after “ ” will
ash for 2 seconds. The pump then begins to inate the cuff. The increasing pressure in
the cuff is shown on the display.
2. After the suitable pressure has been reached, the pump stops and the cuff gradually
deates. The cuff pressure will then be displayed. In case the initial ination is not
sufcient, the device automatically re-inates to a higher pressure.
3. When the device detects a heartbeat, the heart symbol “ ” on the display starts to ash
for every heartbeat.
4. When the measurement has been completed, the systolic, diastolic and pulse rate will
appear on the display.
5. The measurement readings remain on the display until you switch off the device. If no
button is pressed, the device switches off itself in 3 minutes.
NOTE: The symbol “ ” will be displayed along with the reading if irregular heartbeat has
been detected during the measurement. If the “ ” symbol appears frequently (e.g. several
times a week), it may be an indication of a more serious heart problem, and you should consult your doctor.
Cuff on
right arm
M D PM
M D PM
M D PM

3.5 Hypertension Classication Indicator
The bars on the left hand edge of the display show you the range within which the indicated blood pressure
values lies. Depending on the height of the bar, the readout value is either within the normal (green), borderline
(yellow) or danger (red) range.
The classication is based on standards adopted from WHO (World Health Organization), which is recognized by
Hypertension Canada.
Refer to the chart below for details of the classication.
The indicator bar rises according to your measurement.
• If your measurement has only one or two bars, your measurement is in the
green zone, or “Normal” according to National Institute of Health (NIH)
standards.
• If your measurement has three bars, it is in the yellow zone, or “Pre-
Hypertension” according to NIH standards, or high normal according to the
WHO classication.
• If your measurement has four bars, it is in the red “Stage 1 Hypertension” zone.
• If your measurement has ve bars, it is in the red “Stage 2 Hypertension” zone.
• If your measurement has six bars, it is in the red “Stage 3 Hypertension” zone.
Red
Red
Red
Yelllow
Green
Green
Red
Red
Red
Yelllow
Green
Green
Red
Red
Red
Yelllow
Green
Green
3.6 Viewing Previously Recorded Values
The blood pressure monitor automatically stores your measurements with time and date. It can store up to 90
measurements for each of the 2 users. When more than 90 measurements are made, the oldest readings are
deleted for that particular user to make space for the new measurements.
Press the MEM button, the average of the last 3 measurements will be shown, press the MEM button again to see
the most recent measurement value. The date and time of the measurement are also displayed with the reading. Press
the MEM button repeatedly to view all the measurements that are recorded on the device.
Note: Blood pressure measurements are not stored when an error is encountered during
measurement.
SYS
WHOWorld Health Organization 2003
180
160-179
110
100-109
90-99
85-89
80-85
80
140-159
130-139
120-130
120
(mmHg) DIA
Red
Red
Red
Yellow
Green
Green

3.7 Clear Measurements From Memory
If you are sure that you want to permanently remove all stored memories, press the SET button 7 times until
“” appears when the power is off. Press the START/STOP button until “ ” ashes 3 times to clear the
memory. After this, press the MEM button, the symbols “ ” and “ ” will appear on the screen. This means
that the memory has successfully cleared.
NOTE: You cannot clear individual measurements.
3.8 Discontinuing a Measurement
If it is necessary to interrupt a blood pressure measurement for any reason (e.g. the patient feels unwell), the START/
STOP button can be pressed at any time. The device then immediately lowers the cuff pressure automatically.
4. Error Messages / Malfunctions
If an error occurs during a measurement the LCD displays the corresponding error code.
Error Possible Cause Remedy
Weak signal or a sudden change in pressure
Ensure that the cuff is worn correctly
and measure again. Avoid movement or
talking when the cuff is being inated.
External disturbance (eg. if there is a cell
phone near by)
Electromagnetic interference can cause
odd behaviour in the monitor. Move away
from the source.
Appears when there is an error during the
ination process
Make sure the cuff is wrapped around
the arm properly and that the air plug is
properly connected to the unit.
Abnormal blood pressure Rest for 5 minutes and try measurement
again.
Low battery Replace batteries.
If problems occur when using the device the following points should be checked, and if necessary, the
corresponding measures should be taken.
Malfunction Remedy
The display remains blank when the device is
switched on.
1. Check batteries for correct polarity.
2. If using the AC adapter, ensure it is correctly
inserted.
The pressure does not rise even though the pump
is running.
Check the connection of the cuff tube and connect
properly if necessary.

The device frequently fails to measure the blood
pressure values, or the values measured are too low
or too high.
1. Check the positioning of the cuff and cuff tension.
The cuff should be snug but not tight.
2. Measure the blood pressure again, ensuring that
you have remained motionless for a sufcient
amount of time to ensure an accurate reading.
Every measurement produces varying results
although the instrument functions normally and the
values displayed are normal.
Note that blood pressure uctuates continuously;
therefore measurements will show some variability.
Blood pressure values measured differ from those
measured by the doctor.
Record the daily development of the values and
consult your doctor.
Note: Individuals visiting their doctor
frequently experience anxiety which can
result in a higher blood pressure reading than
at home.
5. Care and Maintenance
a) Do not expose the device to either extreme temperatures, humidity, dust or
direct sunlight.
b) The cuff contains a sensitive air-tight bubble. Handle this carefully and avoid all
types of stress through twisting or buckling.
c) Clean the device with a soft, dry cloth. Do not use gas, thinners or similar
solvents. Spots on the cuff can be removed carefully with a damp cloth and
soapsuds. The cuff with bladder must not be washed in a dishwasher, clothes
washer, or submerged in water.
d) Handle the tube carefully. Do not pull on it. Do not allow the tubing to kink and
keep it away from sharp edges.
e) Do not drop the monitor or treat it roughly in any way. Avoid strong vibrations.
f) Never open the monitor. This voids the manufacturer’s warranty.
g) Batteries and electronic instruments must be disposed of in accordance with
the locally applicable regulations, not with domestic waste.
6. Lifetime Guarantee
RexallTM/MC blood pressure monitors have a lifetime warranty to be free of manufacturing defects for the life of
the original owner. This warranty does not include the ination system including the cuff and ination bladder.
The cuff is warranted for two years. The warranty does not cover damage from misuse or tampering.
If you have questions regarding the operation of your monitor call the
Blood Pressure Hotline: 1-866-536-2289

Should repair be necessary, return the unit with all component pieces. Enclose proof of purchase and $5.00 for
return shipping and insurance. Ship the unit prepaid and insured (at owners option) to:
BIOS Medical
Repair Department
16975 Leslie Street
Newmarket, ON L3Y 9A1
MADE IN CHINA
Please include your name, return address, phone number, and email address. BIOS Medical will repair or
replace (at BIOS Medical’s discretion) free of charge any parts necessary to correct the defect in material or
workmanship.
Please allow 10 days for repair and return shipping.
7. Technical Specications
Weight: 250g (with batteries)
Size: 100mm (W) x 132mm (L) x 45mm (H)
Storage temperature: -20°C to 55°C / -4°F to 131°F
Humidity: 10 to 85% relative humidity maximum
Operation temperature: 10°C to 40°C / 50°F to 104°F
Display: LCD-Display (Liquid Crystal Display)
Measuring method: Oscillometric
Pressure sensor: Capacitive
Measuring range:
SYS/DIA: 30 to 299 mmHg
Pulse: 40 to 199 beats per minute
Cuff pressure display range: 0 to 299 mmHg
Memory: Automatically stores the last 90 measurements for 2 users (total 180)
Measuring resolution: 1 mmHg
Accuracy: Pressure within ± 3 mmHg
Pulse ± 5% of the reading
Power source: 4 AA batteries, 1.5V
AC adapter 6V DC 600 mA
Accessories: Wide range cuff for arm circumference 24-43 cm / 9.4”-17”

Technical alterations reserved
Read the instruction manual carefully before using this device, especially the safety instructions, and keep
the instruction manual for future use.
Type BF applied part
Batteries and electronic devices must be disposed of in accordance with the locally applicable
regulations, not with domestic waste.
IP20: Protected against solid foreign particles with a diameter of more than 12.5 mm, no protection
against water.
Other manuals for RX810
1
Table of contents
Other Rexall Blood Pressure Monitor manuals
Popular Blood Pressure Monitor manuals by other brands

Hangzhou Hua'an Medical & Health Instruments
Hangzhou Hua'an Medical & Health Instruments MW-300C Operation guide

Microlife
Microlife BP W1 Basic instructions

HoMedics
HoMedics BP-A11-02CA Instruction manual and warranty information

HoMedics
HoMedics BPW-200-0 TheraP instruction manual

smartheart
smartheart 01-509 instruction manual

Medisana
Medisana 51230 manual