RibbonJoG Mk II User manual

DECLARATION OF CONFORMITY
Manufacturers Name: CableJoG Ltd.
.
Address: 18 Browmere Drive, Croft,
WARRINGTON. CHESHIRE WA3 7HT.
U.K.
Type of equipment: Cable tester
Model: RibbonJoG mkII
I hereby declare that the equipment specified above conforms to the provisions of the EC
DIRECTIVE 2004/108/EC on Electromagnetic Compatibility (EMC)
Having applied the following standards;
BS EN 61000-6-1 :2007
“Generic EMC Immunity Standard for the residential, commercial
& light industry environment”.
BS EN 61000-6-3 :2007
“Generic EMC Emissions Standard for the residential, commercial
& light industry environment”.
RibbonJoG®mkII
operations manual
Please read the following instructions carefully before using the RibbonJoG®
mkII Cable Tester.
Warning:
The Cables to be tested must be fully disconnected from any other
equipment or electrical source. Failure to do so could result in electrical
shock and permanent damage to the RibbonJoG®mkII Cable Tester, for
which the manufacturer and suppliers can accept no liability.
Introduction
The RibbonJoG®mkII Cable Tester is a versatile ribbon cable tester. It allows
the user to either identify a correctly made standard ribbon cable, or carry out
rapid comparison tests having stored known good cable details.
Cables fitted with any of the following standard 0.1" (2.54mm) pitch
connectors may be checked:
The RibbonJoG®mkII Specifications:
€•‚ 10 way
€ƒ„ 14 way
€…† 16 way
€‡ˆ 20 way
€‰Š 26 way
€‹Œ Continuity ( end to end ), less than 4.7K ohms
€•Ž Short Circuits (end to end and between connected pins), less
than 4.7K ohms
€•• Open Circuits (end to end and between connected pins),
greater than 10K ohms
€‘’ Less than 1 second test time
€“” Minimum distance between connectors of same size only
130mm
€•– Non-volatile memory feature
€—˜ 34 way
€™š 40 way
€›œ 50 way
€•ž 60 way
€Ÿ 64 way
11. Adaptor boards
Board #1 New 0.1" or 2.54mm x2.54mm connector sizes 6, 8, 12, 24, 30 &
44 way
Fitting Instructions:
1. Plug into the 64 way connector slots ensuring alignment of fixing holes
with mounting posts.
2. Secure the board with the four m3 screws.
Getting started:
The RibbonJoG®mkII Cable Tester will require fitting of batteries ( not supplied).
Using a No 0 'Supadrive screwdriver remove the countersunk screw on the base
plate to gain access to the battery compartment. Fit four AAA size alkaline or zinc
chloride batteries with polarisation as indicated on the circuit board.
Batteries / Power Saving:
Under normal use the batteries should give at least a years use. However, to
preserve battery life RibbonJoG®mkII has a 'Power Saving' feature. After 15
minutes of inactivity RibbonJoG® mkII will put the microprocessors into sleep
mode. Switch OFF and then ON again to reset RibbonJoG®mkII. Cable details
held in memory will not be lost.
Test Procedure
There are 10 Identifier Light Emitting Diodes (LED's) on the left (red) side of the
unit, each is connected to the last pin of the connector below it. Checking the
status of the ribbon cable is made using the TEST button.
1. Plug one end of the cable to be tested into an appropriate socket using the
right hand (Blue) half of the RibbonJoG® mkII.
2. Plug the other end of the cable to be tested into an appropriate socket using
the left hand (Red) half of the RibbonJoG® mkII.
3. Switch ON.
If no cable has been plugged in each of the LEDS will light in turn. After this the
tester is ready. Should the MEMORY option have been used then the MEMORY
LED will stay ON to indicate that the comparison test will be carried out against
stored cable details. If this is not the case then please check and replace the
batteries if required , otherwise return the RibbonJoG® mkII for repair.
4. To start the test press and release the TEST button.
5. Standard test (memory option not used)
Each wire is tested separately, as the wire corresponding to a identifier LED is
tested the LED will light. The test stops at the first wire with no connection
between the left and right hand connectors.
6. Standard test, results
a) PASS The Pass LED will be on as well as one of the connector identifier
LED's. This shows the last good connection found, not necessarily the size of
connector used. The Pass LED will only come on if the number of connections
found corresponds to one of the 10 possible connector sizes (see page I).
6. Standard test, results
b) FAIL - OPEN circuit The Fail OPEN LED will be on as well as one
of the connector identifier LED's. This shows the last good connection found,
so the fault occurred somewhere between the last pin of the connector
identified and the last pin of the next connector.
c) FAIL - SHORT circuit The Fail SHORT LED will be on, as well
two connector identifier LED's showing that the short circuit is locate between
them. If only the No. 10 identifier LED will be lit and the short is somewhere in
the first 10 pins.
7. A non-standard cable assembly will fail the standard test. RibbonJoG®mkII
can test non-standard cables by identifying and storing all the connections in
that cable. These stored details can then be used to test against other cables.
Connect the non-standard cableand press the TEST button. On completion of
the standard test press and hold the test button until the MEMORY LED come's
on. Releasing the test button will cause RibbonJoG®to go through the test
again, this time not stopping until the last pin (64). The connection details will
be put into memory. After all 64 pins have been stored RibbonJoG®will be
ready.
8. Memory Test
The MEMORY will stay on during the test.The test stops at the last wire (64).
The memory can hold up to 128 differences from the normal pin 1 to pin 1, pin
2 to pin 2 etc. connections.
9. Memory Test Results
a) PASS - The Pass LED will turn on.
b) FAIL - OPEN circuit, the Fail OPEN LED will be on.
c) FAIL - SHORT circuit, the Fail SHORT LED will be on.
As in the standard test (section 6) the PASS and FAIL LED's work in
conjunction with the identifier LED's to give as much information as possible
about the cable under test. However because the connection details in memory
may be very complicated the identifier LED's may not be able show the true
fault location.
10. On completion of the test it is possible to reset the MEMORY option by
pressing and holding the test button until the MEMORY LED goes off.
Releasing the test button will cause the RibbonJoG®mkII to go through the
standard test

Popular Cable Tester manuals by other brands

Fluke IT200 user manual

Fluke

Fluke IT200 user manual

Steren HER-435 manual

Steren

Steren HER-435 manual

Rosewill RTK-T05 user manual

Rosewill

Rosewill RTK-T05 user manual

Klein Tools VDV Scout Pro 3 instruction manual

Klein Tools

Klein Tools VDV Scout Pro 3 instruction manual

Tripp Lite T020-001-PSF owner's manual

Tripp Lite

Tripp Lite T020-001-PSF owner's manual

Shineway Tech NCT-500 user manual

Shineway Tech

Shineway Tech NCT-500 user manual

Steren HER-256 instruction manual

Steren

Steren HER-256 instruction manual

Chauvin Arnoux CA 7028 user manual

Chauvin Arnoux

Chauvin Arnoux CA 7028 user manual

Belkin F5F314-T user manual

Belkin

Belkin F5F314-T user manual

Fluke MicroMapper user guide

Fluke

Fluke MicroMapper user guide

Triplett CTX200PA user manual

Triplett

Triplett CTX200PA user manual

Triplett WireMaster HDMI2 instruction manual

Triplett

Triplett WireMaster HDMI2 instruction manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.