Richard Wolf E2085.00 Series User manual

EE
(LOF)
MODEL
E2085.00
SERIES
BIPOLAR
ELECTROSURGICAL
GENERATOR
OPERATION
MANUAL
This
instruction
manual
covers
the
functions
of
units
E2085.00B
(black
faceplate)
and
E2085.00
(cream
faceplate).

OLE
丹
MODEL
E2085.00
|
|
BIPOLAR
ELECTROSURGICAL
GENERATOR
TABLE
OF
CONTENTS
PAGE
GENERAL
DESCRIPTION
PRECAUTIONS
OPERATION
FUSE
REPLACEMENT
WARRANTY
AND
CUSTOMER
SERVICE
TROUBLESHOOTING
SPECIFICATIONS
OD
B
BNB
-+
GENERAL
DESCRIPTION
The Richard
Wolf
Model
E2085.00
is
a
mini-bipolar
electrosurgical
unit.
An
am-
meter
is
incorporated
into
the
E2085.00
to
provide
the
surgeon
with
a
visual
indica-
tion
of
the
progress
of
the
operation.
Richard
Wolf,
as
manufacturer
and
seller
of
these
units,
will
not
accept
any
liability
for
direct
or
consequential
damage
caused
by
incorrect
use
or
operation
of
these
units,
especially
if
these
instructions
are
not
followed
or
the
unit
Is
subjected
to
incorrect
care
or
service.
E64-07-87
1/5

PRECAUTIONS
|
Always
observe.
the
following
precautions
when
operating
the
E2085.00
Electrosurgical
Generator:
e
Carefully
unpack
the
unit
and
visibly
check
to
see
if
any
damage
occured
during
shipment.
e
This
unit
was
fully
tested
at
the
factory
before
shipment.
As
a
precaution,
it
is
recommended
that
the
unit
be
tested
prior
to
a
surgical
procedure.
NEVER
operate
this
unit
in
the
presence
of
flammable
anesthetics.
NEVER
remove
the
cover,
because
of
electric
shock
hazard.
Refer
servicing
to
qualified
personnel.
For
continued
protection
against
fire
hazard,
always
repiace
the
blown
fuse
with
the
same
type
and
rating.
Do
not
use
this
unit
without
proper
electrical
ground.
Do
not
block
the
ventilation
vents.
OPERATION
This
section
provides
a
description
of
the
features
and
modes
of
operation
of
the
Model
E2085.00
Bipolar
Electro-
surgical
Generator.
POWER
The
Power
Switch
(1)
supplies
current
to
the
electrosurgical
unit
E2085.00.
This
switch
should
be
turned
on
only
when
Bipolar
current
is
required
and
only
then
after
following
the
operating
instructions.
OPERATING
INSTRUCTIONS:
BIPOLAR
WARNING
DO
NOT
MODIFY
THE
BIPOLAR
CABLE
IN
ANY
WAY.
ANY
MODIFICATIONS
ARE
DONE
AT
YOUR
OWN
RISK
AND
WILL
VOID
ALL
WARRANTIES
ON
THIS
CABLE
AND
ANY
WOLF
INSTRUMENTS
USED
WITH
IT.
1.
Make
sure
all
cables
are
in
good
condition.
2.
Make
sure
ail
connections
are
completely
free
of
moisture.
3.
Connect
footswitch
cable
to
Footswitch
Receptacle
(2).
Place
footswitch
in
proper
position
for
operation
(by
surgeon
only.)
4.
Insert
active
Bipolar
cable
into
the
Bipolar
Receptacle
(3).
Do
not
connect
active
cable
to
instruments
until
unit
is
ready
to
be
used.
5.
Depress
the
Power
Switch
(1).
6.
Depress
the
footswitch
when
power
is
needed.
7.
The
Ammeter
(5)
provides
the
surgeon
with
a
visual
indication
of
the
progress
of
his
operation.
Normal
meter
operation
would
show
a
decrease
in
current
flow
as
the
tubal
ligation
progresses.
8.
The
tone
emitted
by
the
unit
and
the
illumination
of
the
Bipolar Indicator
Light
(6),
above
the
Bipolar
Recep-
tacle,
indicates
that
the
unit
is
functioning.
215
E64-07-87

OPERATION
FIGURE
1.
Model
2085.00
Bipolar
Electrosurgical
Generator
FRONT
BACK
1.
POWER
SWITCH
6.
BIPOLAR
INDICATOR
LIGHT
2.
FOOTSWITCH
RECEPTACLE
7.
BUMPER
TRIM
3.
BIPOLAR
RECEPTACLE
8.
LINE
CORD
4.
BIPOLAR
CURRENT
CONTROL
9.
FUSE—3
A/250
V
5.
AMMETER
10.
HANDLE
E64-07-87
3/5

FUSE
REPLACEMENT
|
To
replace
the fuse,
push
the
Fuseholder
Cap
(9)
in
and
to
the
left.
Replace
a
blown
fuse
with
the
same
type
of
3
A/250
V
(9)
fuse.
Push
Fuseholder
Cap
(9)
in
and
turn
to
the
right.
If
trouble
is
encountered
with
the
Model
E2085.00,
perform
the
procedures
in
the
Troubleshooting
Chart.
If
the
problem
persists,
refer
the
unit
to
qualified
personne!
for
servicing.
For
technical
assistance,
contact
the
Richard
Wolf
Customer
Service
Department.
WARRANTY
AND
CUSTOMER
SERVICE.
We
unconditionally
guarantee
our
instruments
to
be
free
from
any
defects
in
materials
and
workmanship
under
normal
use
and
service.
If
repair
becomes
necessary,
our
policy
is
one
of
customer
accommodation.
These
instructions
do
not
attempt
to
cover
all
details
or
variations
in
equipment,
nor
to
provide
for
every
possible
contingency
to
be
met
in
connection
with
installation,
operation,
or
maintenance.
Should
further
information
be
required
or
should
problems
arise
which
are
not
covered
sufficiently
for
the
purchaser's
purpose,
the
matter
should
be
referred
to
the
Richard
Wolf
Medical
Instruments
Corp.
Our
national
sales
and
service
offices,
as well
as
our
manufacturing
facility,
are
located
in
Illinois.
Trained
manufacturer’s
representatives
are
located
throughout
the
United
States
to
serve
you.
For
any
ques-
tions
regarding
these
instruments,
or
to
place
an
order,
contact
the
Richard
Wolf
Customer
Service
Department
at
the
following
numbers:
In
Illinois,
(708)
913-1113;
Outside
of
Illinois,
(800)
323-WOLF.
Instrument
Ordering
Policy
We
reserve
the
right
to
make
substitutions,
if
necessary,
without
prior
notice.
Repair
Policy
Defective
merchandise
will
be
repaired
or
replaced
at
no
charge
to
the
customer,
provided
the
customer
delivers
such
defective
merchandise
prepaid.
Any
repairs,
maintenance
or
servicing
of
our
merchandise
by
anyone
other
than
a
factory
authorized
represen-
tative
will
render
our
warranty
null
and
void.
When
returning
your
instrument
for
repair,
we
suggest
that
you
use
the
box
it
was
originally
shipped
in,
in
order
to
prevent
damage
to
the
instrument
in
transit.
We
also
recommend
that
the
instrument
be
insured
for
an
amount
to
cover
the
cost
of
replacement.
IMPORTANT
FOR
GENERAL
SAFETY
AND
HEALTH
REASONS,
WE
REQUIRE
THAT
YOU
CLEAN
AND
STERILIZE
ALL
INSTRUMENTS
BEFORE
RETURNING
THEM
FOR
REPAIR.
EFFECTIVE
OCTOBER
1,
1990,
IF
INSTRUMENTS
ARE
RECEIVED
IN
AN
UNSANITARY
CONDITION,
THEY
WILL
BE
RETURNED
IMMEDIATELY
TO
THEIR
POINT
OF
ORIGIN,
PREPAID.
TROUBLESHOOTING.
PROBLEM
POSSIBLE
SOLUTION
No
Bipolar
Output
Verify
that
the
unit
is
connected
to
the
AC
power
supply.
No
Indicator
Light
or
Audible
Tone
Inspect
line
cord
for
visible
damage.
Check
for
blown
3A
fuse.
Check
that
footswitch
plug
is
properly
inserted
and
secured.
No
Bipolar
Output
Check
to
ensure
cables,
plugs
and
insulation
are
in
Indicator
Lamp
Lights
and
Tone
good
condition.
| |
Sounds
but
No
Power
Output
Check
that
cable
between
bipolar
forceps
and
bipolar
receptacle
is
properly
inserted
and
secured.
Check
that
instrument
tips
are
free
of
encrusted
tissue.
Check
that
an
adequate
power
setting
is
selected.
415
E64-07-87

SPECIFICATIONS
PHYSICAL
Height...............
5.0
in.
Width...............
12.5
in.
Depth
..............
12.0
in
Weight
..............
16
Ibs
ELECTRICAL
.
Power
Supply
Inside
Fuse
Outside
Fuse
Cord
Plug
Line
Cord
Bipolar
Output
Maximum
Power
120
V
AC.
60
Hz
2.5
A/250
V
SLO-BLO
3
A/250
V
Hospital
Grade
Hubbell
SJT
18/3-8ft.
long
50
Watts
200
Watts
RICHARD
WOLF
MEDICAL
INSTRUMENTS
CORP.
353
CORPORATE
WOODS
PARKWAY
«
VERNON
HILLS,
IL
60061
Tel:
(708)
913-1113
+
Customer
Service:
1
(800)
323-
WOLF
Repair
Service:1
(800)
323-2160
E64-07-87
515
This manual suits for next models
1