SAFETY INFORMATION – We recommend
that luminaires be installed by a fully qualied and
competent electrician who understands building
regulations and the current IEE wiring regulations. The
light source contained in this luminaire shall only be
replaced by the manufacturer or a qualied professional.
Before commencing any installation or
Maintenance work, ensure that the electricity is
switched off at the mains.
PLEASE READ THESE INSTRUCTIONS CAREFULLY BEFORE INSTALLATION AND LEAVE
A COPY WITH THE END USER FOR FUTURE REFERENCE.
IMPORTANT USER INFORMATION
Please install and use strictly in accordance with
these instructions. Make sure that you have all the
tools and equipment to complete the installation
safely and correctly. Improper installation could
cause harm to your property and/or person and
void your warranty.
It is the installer’s responsibility to consider re
and safety risks and take appropriate precautions.
RoHSRoHS
IP65
SPECIFICATION & DIMENSIONS
Kelvin: 5000K
Power Supply: AC220-240V
Power Factor: >0.90
CRI: >80 Ra
Body: Die-Cast Aluminium
PRE INSTALLATION INSTRUCTIONS & GUIDELINES
• Do not disassemble or amend the structure of the luminaire as this can be dangerous and it would void your warranty.
• Ensure that ALL electrical connections are tight with no loose strands.
• This product may contain substances that can be hazardous to the environment if not disposed of properly.
• Electrical and electronic equipment should never be disposed of with general household waste but must be separated for its correct
treatment and recovery. Where possible recycle your packaging.
• This product contains a light source of energy efciency class F.
A
B
C
Product Code Wattage Lumens Running
Current Unit Weight (kg)
R301500/50W 50W 5654 625mA 0.94
R301500/100W 100W 13904 220mA 2.20
R301500/150W 150W 19119 470mA 4.13
R301500/200W 200W 27744 625mA 5.50
Wattage A B C
50W 200mm 237mm 39mm
100W 282mm 321mm 41mm
150W 420mm 333mm 51mm
200W 470mm 385mm 51mm

ifl
0161-451-5924 support@ricoman.com www.ricoman.com
Before following these steps please ensure you have read and adhered to the guidelines and information overleaf.
Hydra LED Floodlight
INSTALLATION STEPS
STEP 1 STEP 2
ENVIRONMENTAL PROTECTION
Waste Electrical & Electronic Equipment Regulations (WEEE) requires that any of our products showing this marking must not be disposed of with
other household or commercial waste. To prevent possible harm to the environment or human health from uncontrolled waste disposal, please
separate any such product from other waste types and recycle it responsibly at your local facilities. Check with your Local Authority, Recycling
Centre or retailer for recycling advice.
WARRANTY
This product is in warranty in the UK for a period of 5 year from the date of purchase. The guarantee is invalid in the case of improper use, installation,
tampering, removal of the Q.C. date label, installation in an improper working environment or installation not according to the current edition of the IEE Wiring
Regulations. Should this product fail during the warranty period, it will be replaced free of charge, subject to the aforementioned conditions and return of the
faulty unit. We do not accept responsibility for any installation costs associated with the replacement of this product. Your statutory rights are not affected.
Product Code: SSTE/50/ST/BK/850
SSTE/100/ST/BK/850
SSTE/150/ST/BK/850
SSTE/200/ST/BK/850
Product Description: Stealth LED Floodlight
Installation Instruction
SSTE/50/ST/BK/850 SSTE/100/ST/BK/850 SSTE/150/ST/BK/850 SSTE/200/ST/BK/850_II_V1
565
Dimension
Important Information
It is recommended that luminaires are installed / maintained by a fully qualified electrician and wired in accordance
to the latest IEC standards or national equivalent.
Mains power must be switched off during any installation or maintenance.
This product is guaranteed for a period of 5 years from date of purchase. The guarantee is invalid in the case of
improper use, improper installation or tampering. Should the product fail during the guarantee period it will be
replaced free of charge, subject to correct installation and return of the faulty unit. The manufacturer is not
responsible for any costs associated with the replacement of this product.
This product may contain substances that can be hazardous to the environment if not disposed of properly.
Electrical and electronic equipment should never be disposed of with general household waste but must be
separated for its correct treatment and recovery. Where possible recycle your packaging.
This product contains a light source of energy efficiency class F.
LH
W
12
ALWAYS SWITCH OFF THE
MAINS SUPPLY BEFORE
INSTALLATION OR SERVICING
50W
L W H
100W
150W
200W
200mm 237mm 39mm
41mm
51mm
51mm
320mm
333mm
385mm
282mm
420mm
470mm
Turn off the mains power supply.
Product Code: SSTE/50/ST/BK/850
SSTE/100/ST/BK/850
SSTE/150/ST/BK/850
SSTE/200/ST/BK/850
Product Description: Stealth LED Floodlight
Installation Instruction
SSTE/50/ST/BK/850 SSTE/100/ST/BK/850 SSTE/150/ST/BK/850 SSTE/200/ST/BK/850_II_V1
565
Dimension
Important Information
It is recommended that luminaires are installed / maintained by a fully qualified electrician and wired in accordance
to the latest IEC standards or national equivalent.
Mains power must be switched off during any installation or maintenance.
This product is guaranteed for a period of 5 years from date of purchase. The guarantee is invalid in the case of
improper use, improper installation or tampering. Should the product fail during the guarantee period it will be
replaced free of charge, subject to correct installation and return of the faulty unit. The manufacturer is not
responsible for any costs associated with the replacement of this product.
This product may contain substances that can be hazardous to the environment if not disposed of properly.
Electrical and electronic equipment should never be disposed of with general household waste but must be
separated for its correct treatment and recovery. Where possible recycle your packaging.
This product contains a light source of energy efficiency class F.
LH
W
12
ALWAYS SWITCH OFF THE
MAINS SUPPLY BEFORE
INSTALLATION OR SERVICING
50W
L W H
100W
150W
200W
200mm 237mm 39mm
41mm
51mm
51mm
320mm
333mm
385mm
282mm
420mm
470mm
Install the bracket.
STEP 3 STEP 4
Install the bracket.
Installation Instruction
4
3
5
9
SSTE/50/ST/BK/850 SSTE/100/ST/BK/850 SSTE/150/ST/BK/850 SSTE/200/ST/BK/850_II_V1
50W Max. M6: 15N.m
100W Max. M8: 30N.m
150W Max. M10: 40N.m
200W Max. M10: 40N.m
NL
Blue
Yellow/Green
Brown
Installation Instruction
4
3
5
9
SSTE/50/ST/BK/850 SSTE/100/ST/BK/850 SSTE/150/ST/BK/850 SSTE/200/ST/BK/850_II_V1
50W Max. M6: 15N.m
100W Max. M8: 30N.m
150W Max. M10: 40N.m
200W Max. M10: 40N.m
NL
Blue
Yellow/Green
Brown
Installation Instruction
4
3
5
9
SSTE/50/ST/BK/850 SSTE/100/ST/BK/850 SSTE/150/ST/BK/850 SSTE/200/ST/BK/850_II_V1
50W Max. M6: 15N.m
100W Max. M8: 30N.m
150W Max. M10: 40N.m
200W Max. M10: 40N.m NL
Blue
Yellow/Green
Brown
STEP 5
Turn the power back on and test.
This manual suits for next models
3
Table of contents
Popular Floodlight manuals by other brands

Festool
Festool SYSLITE DUO Original operating manual

Boca Flasher
Boca Flasher HPCCS installation manual

thomann
thomann STAIRVILLE xBrick Quad 16x8W RGBW user manual

American DJ
American DJ Millennium Y2L User instructions

Stahl
Stahl 6125 Series operating instructions

Scanic
Scanic LED Double Eye Moonflower DMX instruction manual