Plano Exam - VA Check
2.2 Data Input/Transfer from Lens Meter
Setting Menu
Examination Basic Flow
1. Start up and System Initialization
2.1 Data Input/Transfer from Autoref
3. PD and Forehead Rest Adjustment
4.1 Preset Program EXAM.
- auto initialized as turn on
power, or
To initialize RVll system
- manual initialization
press AC twice, or
Please refer to RVll Instruction Manual for details.
Selectable preset programs
program finish if
"End Program"
indicated on
screen of CB
refer to Leaflet "Program
Examination" for details
Press R, L or R&L
Press ▲▼
to check
highest VA
Press
Plano
AUTOREF or LM data transferred first will be copied in SBJ1
Selectable receiving 1 or 10 data in setting menu “Communication Setting 2”
After press REF, if selected receiving 1 data, Autoref data is set
After press REF, if
selected receiving 10
data, select data
number in dot screen
Press SET
Press NEXT or
BACK to select
Selectable receiving 1 or 10 data in setting menu “Communication Setting 2”
After press LM, if selected receiving 1 data, Autoref data is set
After press LM, if
selected receiving 10
data, select data
number in dot screen
Press SET
Press NEXT or
BACK to select
AUTOREF or LM data transferred first will be copied in SBJ1
1. Start up
and system
initialization
3. PD and forehead
rest adjustment
2.1 AUTOREF Data
2.2 LM Data
5. Data comparison
6. Print and/or data to PC
4.1 Preset program
4.2 Individual Exam.
Basic Flow
turn on the RVll power box
turn on the chart instruments
L40P RG24RT
Dot matrix LED
indicates
Data receive
To receive data
press
To transfer data, press/touch
- Speedy K2 - touch screen
- Speedy i/iK - press
- Retinomax - press
to trasnfer data, press
of LM screen
select COM by setting menu if
LINK indicated on LM screen
Dot matrix LED
indicates
Data receive
To receive data
press
to start, status should
be SBJ1 or SBJ2
press press select program
on control box
screen, then
touch SET for
start
press BACK
return to
previous
press NEXT
for next step
turn jog dial for adjust
2. Data transfer
turn jog dial for
PD adjust
turn dial and set the corneal
vertex distance
VD:12mm
VD:13.75mm
press PD
press R or L
To adjust split PD
press OFF
to exit PD
press SBJ1,
if in other
status
turn jog dial for
PD adjust
4. Exam
Program NP3S Pola RG
Prog1(editable) Yes Yes Yes
Prog2(editable) Yes Yes Yes
Speedy Yes Yes Yes
21point No No No
MCH No No No
- changed communication
setting and saved
After change of chart instrument, in the program menu screen, touch RESET to show SET and EDIT
RVII Quick Reference
Operation by Remote Control (RC)
Main Menu
Initial Setting
Simple Setting
Eye Exam
Program Edit
Factory Default
Back to previous
RVll R3 ver.2
SET IN
Press
SET
Blinking
for set
Press R,L,S,C,A to set
the value
Press SET IN,
to set the lens
Press to cancel SET IN
SET IN function is equipped after ver.3.02.01.