Rinnai Brivis 1F83C-11PRBR User manual

Brivis 1 DGH Manual Controller IM
by
Programmable Controller
Installation Manual
Model
1F83C-11PRBR
Single Stage Thermostat

Brivis 2 DGH Manual Controller IM
For continued safety of this appliance it must be installed
and maintained in accordance with the manufacturer’s
instructions. Read precautions carefully before proceeding
with installation.

Brivis 3 DGH Manual Controller IM
TABLE OF CONTENTS
Thermostat Applications.....................................................................................4
Specications ......................................................................................................4
Thermostat Installation 5
Wiring....................................................................................................................5
Precautions ..........................................................................................................5
Installer Menu.......................................................................................................6
Test Equipment ....................................................................................................7
Using The Thermostat 8
Thermostat Overview ..........................................................................................8
User Menu ............................................................................................................9
Thermostat Operation .........................................................................................9
Thermostat Schedule / Programming..............................................................10
Troubleshooting.................................................................................................10
Contacts .............................................................................................................12

Brivis 4 DGH Manual Controller IM
Electrical Rating:
Battery Power ..................................... mV to 30 VAC, NEC Class II, 50/60 Hz
Input-Hardwire.................................... 20 to 30 VAC, NEC Class II, 50/60 Hz
Terminal Load.......................................... 1.0 A per terminal, 1.5A maximum all terminals combined
Setpoint Range ........................................ 45° to 99° F (7° to 37° C)
Rated Dierentials: Fast Med Slow
Heat (@ 6°F/ Hr).................................. 0.5°F 0.75°F 1.9°F
Cool (@ 6°F/ Hr) .................................. 0.9°F 1.2°F 1.7°F
Operating Ambient .................................. 32°F to +105°F (0° to +41°C)
Display Temperature Range ....................... 32°F to +99°F (0 to 37°C)
Operating Humidity ................................. 90% non-condensing max
Shipping Temperature Range................... -20°F to + 150°F (-29° to +65°C)
Thermostat Dimensions........................... 3-3/4” H x 6” W x 1-1/8” D
BRIVIS: CNTRLHTRPROGE
PART NO. 37-7788001
1912
1F83C-11PRBR (Programmable)
Installation and Operating Instructions
Single Stage Thermostat
Battery Powered or Hardwired with Common
Thermostat Applications
Maximum
Stages
Heat/Cool
Conventional Gas, Oil, Electric (mV and
24V), Heat Only, Cool Only or Heat/
Cool Systems
1/1
Heat Pump (air source or geothermal)
with no Aux. Heat 1/1
Thermostat Installation 2-4
Wiring 2
Installer Menu 3-4
Using the Thermostat 5-7
Thermostat Overview 5
User Menu 6
Thermostat Operation 6
Thermostat Schedule 7
INDEX
SPECIFICATIONS
MERCURY NOTICE: This product does not contain
mercury. However, this product may replace a product
that contains mercury. Mercury and products containing
mercury must not be discarded in household trash.
Refer to www.thermostat-recycle.org for information
on disposing of products containing mercury.
THERMOSTAT APPLICATIONS
SPECIFICATIONS
Electrical Rating:
Battery Power ..................................... mV to 30 VAC, NEC Class II, 50/60 Hz
Input-Hardwire.................................... 20 to 30 VAC, NEC Class II, 50/60 Hz
Terminal Load.......................................... 1.0 A per terminal, 1.5A maximum all terminals combined
Setpoint Range ........................................ 45° to 99° F (7° to 37° C)
Rated Dierentials: Fast Med Slow
Heat (@ 6°F/ Hr).................................. 0.5°F 0.75°F 1.9°F
Cool (@ 6°F/ Hr) .................................. 0.9°F 1.2°F 1.7°F
Operating Ambient .................................. 32°F to +105°F (0° to +41°C)
Display Temperature Range ....................... 32°F to +99°F (0 to 37°C)
Operating Humidity ................................. 90% non-condensing max
Shipping Temperature Range................... -20°F to + 150°F (-29° to +65°C)
Thermostat Dimensions........................... 3-3/4” H x 6” W x 1-1/8” D
BRIVIS: CNTRLHTRPROGE
PART NO. 37-7788001
1912
1F83C-11PRBR (Programmable)
Installation and Operating Instructions
Single Stage Thermostat
Battery Powered or Hardwired with Common
Thermostat Applications
Maximum
Stages
Heat/Cool
Conventional Gas, Oil, Electric (mV and
24V), Heat Only, Cool Only or Heat/
Cool Systems
1/1
Heat Pump (air source or geothermal)
with no Aux. Heat 1/1
Thermostat Installation 2-4
Wiring 2
Installer Menu 3-4
Using the Thermostat 5-7
Thermostat Overview 5
User Menu 6
Thermostat Operation 6
Thermostat Schedule 7
INDEX
SPECIFICATIONS
MERCURY NOTICE: This product does not contain
mercury. However, this product may replace a product
that contains mercury. Mercury and products containing
mercury must not be discarded in household trash.
Refer to www.thermostat-recycle.org for information
on disposing of products containing mercury.

Brivis 5 DGH Manual Controller IM
2
Terminal Designations Terminal Function
RC* Power for Cooling
RH* Power for Heating
O/B Changeover Terminal-Energized in Heat (B) or Cool (O)
for Heat Pump or Damper Systems
Y** Cooling Relay
G Fan Relay
W** Heating Relay
CCommon wire for 24V (optional with batteries)
*When both RC and RH wires are present, cut RC/RH jumper (see next page).
**For heat pump systems, add a jumper wire to connect terminalsY and W
THERMOSTAT INSTALLATION
Leveling Thermostat
Leveling is for appearance only and
will not aect thermostat operation.
WIRING
Refer to equipment manufacturer’s instructions for specic system wiring information. After
wiring, see INSTALLER MENU for proper thermostat conguration. Wiring table shown are
for typical systems and describe the thermostat terminal functions.
WARNING
!
Do not use on circuits exceeding specied voltage.
Higher voltage will damage control and could
cause shock or re hazard.
Do not short out terminals on gas valve or primary
control to test. Short or incorrect wiring will burn
out thermostat and could cause personal injury
and/or property damage.
CAUTION
!
To prevent electrical shock and/or equipment
damage, disconnect electrical power to system,
at main fuse or circuit breaker box,until
installation is complete.
Precautions
• Do not exceed the specication ratings.
• All wiring must conform to local and national electrical codes and ordinances.
• This control is a precision instrument, and should be handled carefully. Rough handing or
distorting components could cause the control to malfunction.
THERMOSTAT INSTALLATION
WIRING
PRECAUTIONS

Brivis 6 DGH Manual Controller IM
3
1.) Gas/Elec Switch
If the system is a heat pump or electric furnace, the GAS/ELEC Switch must be set to
Elec. If your system is a gas or oil furnace, the switch must be set to Gas.
2.) O/B Terminal Switch
The O/B switch on this thermostat is factory set to the Oposition. This will accommodate
the majority of heat pump applications, which require the changeover relay to be
energized in Cool. If the heat pump being installed requires a Bterminal, to energize the
changeover relay in Heat, the O/B switch must be moved to the Bposition.
3.) RC/RH Jumper Wire
This thermostat electrically connects the RC and RH terminals so a jumper wire is not
required. If the application provides a separate wire for RC and RH, clip the RC/RH
jumper. This will isolate both terminals so they can be independently used.
INSTALLER MENU
MENU and an USER MENU.The INSTALLER’S MENU provides access to every option, while
the INSTALLER’S MENU press the Menu button for 8 seconds. The display will show item 30 in
the table below. Use Next and Backto navigate through menu items. Press or to change
a menu setting.
Installer’s Menu #
(Hold Menu 8 Seconds) Description Default Setting Settings
(Press or )
30 Heat Cycle Rate (howoften
the heat will turn on) MEd
SLO – slow
MEd – medium
FAS – fast
35 Cool Cycle Rate (how often
the cooling will turn on) MEd
SLO – slow
MEd – medium
FAS – fast
50 Compressor Lockout
(protects the compressor
from short cycling)
OFF On – 5minute display
OFF – no delay
65 Maximum Heat Limit
(maximum set point for heat mode) 99 47 to 99°F
66 Minimum Cool Limit (minimum
set point for cool mode) 45 45 to 97°F
74 Schedule Type (set as either 7-Day,
5-1-1 Day or Non-Programmable) 5
7– 7 Day
5– 5-1-1 Day
0– Non Programmable
1
3
2
Premium AA alkaline batteries
are required when C-wire is
not available. When C-wire is
available, the batteries provide
a back-up source of power (this
will maintain the clock in the
event of a power outage).
INSTALLER MENU

Brivis 7 DGH Manual Controller IM
4
Installer’s Menu #
(Hold Menu 8 Seconds) Description Default Setting
(ashing icons) Settings
76
Early Start (starts heating or
cooling early so your programmed
temperature is reached by the
programmed time)
OFF
On – start early
OFF – start at program
period time
79 Fahrenheit or Celsius °F °F – Fahrenheit
°C – Celsius
81
Temperature Display
Adjustment (adjust the displayed
“Room Temperature”)
0-5 to +5°F
83
Continuous Display Light (keep
the backlight always on – “C” wire
required)
OFF On – always on
OFF – momentarily
86 Change Air Filter (set up a
monthly reminder) OFF
1 to 12 – reminder time
(months)
OFF – no lter reminder
99 Keypad Lock (prevent unwanted
changes to the thermostat) OFF
On – disable buttons
OFF – all buttons are
active
INSTALLER MENU (C0ntinued)
TEST EQUIPMENT
Turn on power to the system.
Fan Operation
If your system does not have a G terminal connection, skip to Heating System.
1.) Move fan switch to On position. The blower should begin to operate.
2.) Move fan switch to Auto position. The blower should stop immediately.
Heating System
1.) Move System Switch to Heat position.
2.) Press to adjust thermostat setting to 1° above room temperature. The system should
begin to operate and the thermostat will indicate Heat On.
3.) Press to adjust thermostat setting 1° below room temperature. The heating system
should stop operating and the thermostat should indicate Heat.
Cooling System
1.) Move System Switch to Cool position.
2.) Press to adjust thermostat setting 1° below room temperature. The blower should
come on immediately on high speed, followed by cold air circulation. The thermostat will
indicate Cool On. There can be up to a 5 minute delay. (see INSTALLER MENU, item 50)
3.) Press to adjust thermostat setting to 1° above room temperature. The cooling system
should stop operating and the thermostat will indicate Cool.
Note: If Starting Soon is shown on the display, the compressor lockout feature is operating.
There will be up to a 5 minute delay before the compressor turns on.(see INSTALLER MENU,
item 50)
CAUTION
!
To prevent compressor and/or property damage, if the outdoor temperature is below 50°F,
DO NOT operate the cooling system.
Do not allow the compressor to run unless the compressor oil heaters have been operational
for 6 hours and the system has not been operational for at least 5minutes.
TEST EQUIPMENT

Brivis 8 DGH Manual Controller IM
5
5
THERMOSTAT OVERVIEW
Before you begin using your thermostat, you should be familiar with its features, display and
the location/operation of the thermostat buttons and switches.
THERMOSTAT BUTTONS AND SWITCHES THE DISPLAY
1.) Fan Switch 10.) Thermostat is protecting the equipment from short
cycling (5-minute delay)
2.) System Switch 11.) Indicates that the system is running in cool or heat
3.) Backlight Button (located on the top
of the thermostat
12.) Displays the current time
4.) Set Correct Time 13.) Battery status indicator
5.) Hold a Permanent Temperature 14.) Low battery indicator
6.) Cancels Hold – Returns to Programmed
Schedule
15.) Day of the week used when programming a schedule
7.) Raises Temperature Setting 16.) Permanent hold (bypassing the schedule)
8.) Access Menu Options 17.) Temperature setpoint
9.) Lowers Temperature Setting 18.) Appears when the keypad is locked (to prevent unwanted
changes)
19.) Next (Menu button) is used to navigate within a menu
20.) Access the schedule and customize thermostat features
21.) Back (Run button) is used to navigate within a menu
22.) Exit (Hold button) returns to the home screen
23.) SEE TROUBLESHOOTING
USING THE THERMOSTAT
1
2
3
4 5 6
7
8
9
10
11
12 13 14 15 17
18
19
20
21
22
16
23
Whenever “Replace ”appears in the display, new premium brand AA alkaline batteries
should be installed. If the house will be unoccupied for an extended period and either “”
or “ Replace ” is displayed, install new batteries before leaving.
USING THE THERMOSTAT
THERMOSTAT OVERVIEW

Brivis 9 DGH Manual Controller IM
6
THERMOSTAT OPERATION
Set Current Time and Day
Note: Time icons will ash at initial power up or after a reset.
1.) Press Set Time
2.) Use or to adjust the hour
3.) Press Next to advance to set the minutes and day of the week
4.) Press Exit when nished.
The default program is 5-1-1 Day, but can be setup as a 7-Day or Non-Programmable
thermostat (refer to the User Menu above)
• Hold Temperature (bypassing the schedule) – With the System switch set to Heat or
Cool, momentarily press the Hold button. Hold will be displayed. Use or to adjust
the temperature. The thermostat will hold the room temperature at the selected setting
until you press Run to start program operation again.
• Program Override (Temporary Hold) – Press or until the desired temperature is
displayed. The thermostat will override the schedule until the next programmed time
period with a minimum override of 2hours. Then the thermostat will automatically revert
to the program.
• Keypad Lockout – To prevent unwanted changes, the buttons can be disabled. To turn
this feature On, press and hold and the Menu button unl the icon appears. To turn
O, press and hold and the Menu button for 3seconds.
USER MENU
To customize thermostat settings, press the Menu button from the home screen. Use the
or buttons to highlight Settings and press Next. Use Next and Back to navigate
through menu items. Press or to change the setting.
User’s Menu #
(Press Menu button
and release)
Description Default Setting
(ashing icons)
Settings
(Press or )
01 Schedule Type (set as either 7-Day,
5-1-1 Day or Non Programmable) 5
7– 7 Day
5– 5-1-1 Day
0– Non-programmable
02
Early Start (starts heating or
cooling early so your programmed
temperature is reached by the
programmed time)
OFF
On – start early
OFF – start at program
period time
03 Fahrenheit or Celsius °F °F – Fahrenheit
°C – Celsius
04 Temperature Display Adjustment
(adjust the RoomTemperature) 0 -5 to +5°F
05
Continuous Display Light (keep
the backlight always on – “C” wire
required)
OFF On – always on
OFF – momentarily
06 Change Air Filter (set up a monthly
reminder) OFF
1 to 12 – reminder time
(months)
OFF – no lter reminder
USER MENU
THERMOSTAT OPERATION

Brivis 10 DGH Manual Controller IM
7
P1/Wake P2/Leave P3/Return P4/Sleep
Heating Schedule 6:00 AM - 70°F 8:00 AM - 62°F 5:00 PM - 70°F 10:00 PM - 62°F
Cooling Schedule 6:00 AM - 78°F 8:00 AM - 85°F 5:00 PM - 78°F 10:00 PM - 82°F
Note: Thermostat can be programmed on or o the subbase
Modify the Heating Schedule
1.) Slide the system switch to Heat
2.) Press Menu
3.) Press Next to enter the schedule
4.) The time icons will ash – use or to set the time for the start of a period
5.) Press Next – the set point icons will ash – use or to set the temperature for the
current period
6.) Continue to press Next to advance through all periods (P1/Wake, P2/Leave, P3/Return,
P4/Sleep) for all days of the week.
Note: Press Back to return to the previous setting. Once all days of the week have been
programmed the thermostat will display End. Press Exit at any time to save changes
and return to home screen.
Modify the Cooling Schedule
1.) Slide the system switch to Cool
2.) Repeat steps 2-6 from the heating schedule
Symptom Possible Cause Corrective Action
No Heat/
No Cool/
No Fan
(common problem)
1.) Blown fuse or tripped circuit
breaker
2.) Furnace power switch to OFF
3.) Furnace blower compartment
door panel loose or not
properly installed
4.) Loose connection to
thermostat or system
1.) Replace fuse or reset breaker
2.) Turn switch to ON
3.) Replace door panel in proper position to engage
safety interlock or door switch
4.) Tighten Connections
No Heat
1.) System Switch not set to
Heat
2.) Loose connection to
thermostat or system
3.) Heating System requires
service or thermostat
requires replacement
Verify thermostat and system wires are securely
aached.
Diagnosc: Set System Switch to Heat and raise
the setpoint above room temperature. Within ve
minutes the thermostat should make a so click
sound and “Heat On” should appear on display.
This sound indicates the thermostat is operang
properly. If the thermostat does not click, try the
reset operaon listed below. If the thermostat does
not click aer being reset, contact your heang and
cooling service person or place of purchase for a
replacement. If the thermostat clicks, contact the
furnace manufacturer or a service person to verify
the heang system is operang correctly.
THERMOSTAT SCHEDULE / PROGRAMMING
Energy Saving Factory Schedule
This thermostat is programmed with the energy saving settings shown in the table below for
all days of the week.
TROUBLESHOOTING
THERMOSTAT SCHEDULE / PROGRAMMING
TROUBLESHOOTING

Brivis 11 DGH Manual Controller IM
Resetting the Thermostat or Thermostat Settings
If the thermostat has good batteries, but has a blank display or does not respond to key
presses, the thermostat should be reset by removing the batteries for 2 minutes. This reset
will not change the menu settings or program. If the condition persists after reinstalling the
batteries, replace the thermostat.
To conveniently reset only the schedule and user settings back to factory defaults, press Menu
and Backlight buttons at the same time and hold until the display goes blank and resets.
Symptom Possible Cause Corrective Action
No Cool
1.) System Switch not set to
Cool
2.) Loose connection to
thermostat or system
3.) Cooling System requires
service or thermostat
requires replacement
Verify thermostat and system wires are securely
aached.
Diagnosc: Set System Switch to Cool and lower
setpoint below room temperature. Same procedures
as diagnosc for “No Heat” condion except set the
thermostat to Cool and lower the setpoint below the
room temperature. There may be up to a ve minute
delay before the thermostat clicks in Cooling if the
compressor lock-out opon is selected in the installer
menu. (see INSTALLER MENU, item 50)
Heat, Cool or Fan
Runs Constantly
Possible short in wiring,
thermostat, heat, cool or fan
system
Check each wire connection to verify they are not
shorted or touching other wires. Try resetting the
thermostat. If the condition persists contact your
HVAC service person.
Thermostat Display
& Thermometer
Disagree
Thermostat display requires
adjustment
Display can be adjusted +/-5°. See User Menu item
04
Furnace (Air
Conditioner)
Cycles Too Fast or
Slow (narrow or
wide temperature
swing)
The location of the thermostat
and/or the size of the Heating
System may be inuencing the
cycle rate
Digital thermostats provide precise control and cycle
faster than older mechanical models. The system
turns on and o more frequently but runs for a shorter
time. If you would like to increase cycle time, choose
SLO for slow cycle in the Installer menu. (Reference
menu items 30 & 35) If an acceptable cycle rate is not
achieved, contact your HVAC service person.
“Call for Service”
icon appears on
displayed
1.) Heating system is not able
to heat the space to within
10 degrees of the setpoint
within 2hours
2.) Cooling system is not able
to cool the space to within
10 degrees of the setpoint
within 2 hours
3.) If “--” is displayed for the
Room Temperature, a
replacement thermostat is
needed
4.) None of the buttons operate
on the thermostat
1.) See corrective action for “No Heat”
2.) See corrective action for “No Cool”
3.) Replace thermostat
4.) Make sure keypad lockout is not turned on
(denoted by icon)
TROUBLESHOOTING (C0ntinued)

CNTRLHTRPROGE PART NO. 37-7788001 12 DGH Manual Controller IM - Issue 2 May 2020
CONTACTS
Rinnai Australia Pty Ltd
ABN 74 005 138 769 | AU24752
100 Atlantic Drive, Keysborough, Victoria 3173
P.O. Box 460, Braeside, Victoria 3195
Tel: (03) 9271 6625
Fax: (03) 9271 6622
National Help Line
Tel: 1300 555 545* Fax: 1300 555 655
Monday to Friday, 8.00 am to 5.00 pm EST.
*Cost of a local call higher from mobile or public phones.
For further information visit www.rinnai.com.au
or email enquiry@rinnai.com.au
Rinnai has a Service and Spare Parts network with
personnel who are fully trained and equipped to give
the best service on your Rinnai appliance. If your
appliance requires service, please call our National
Help Line.
With our policy of continuous improvement, we
reserve the right to change, or discontinue at any
time, specifications or designs without notice.
Table of contents
Other Rinnai Thermostat manuals
Popular Thermostat manuals by other brands

Emerson
Emerson 1F83-0471 operating instructions

Blanke
Blanke ELOTOP TOUCH operating instructions

Honeywell
Honeywell MultiPRO TB7100A1000/U manual

HAI
HAI Omnistat RC-80BZ installation instructions

Honeywell
Honeywell EConnect TL9160AR operating manual

Danfoss
Danfoss TP9000 Installation and user instructions