SET TIMES
ECONOMY UP
6. Connect the red and blue pins of the sub PCB (Central Timer Harness) to the corresponding red and blue connecng pins of the
direct vent furnace.
7. Wire the sub PCB (Power Harness) to the transformer and the eld supplied wall thermostat (see wiring diagrams on following
page).
8. Re-connect power supply.
9. Adjust heater to Remote Thermostat mode by having the unit in OFF mode (sll plugged in). Press and hold the ECONOMY +
UP + SET TIMES buons (PROGRAM buon for EX38CT model) for 2.5 seconds. The display will show 00. Press the UP buon;
the display will read 01. Press the ON/OFF buon, the display will go blank. The unit is now in Remote Thermostat mode. Do
not unplug the direct vent furnace within two hours of making the mode adjustments; if the direct vent furnace is un-
plugged within two hours, it will revert back to the default Control Panel mode.
PROGRAM buon for
EX38CT models