1. Introduction of BTM-D1A -Ear Thermometer
Key Pads & Functions
(1) The Receiver
Theinstruction oftheKeysand thePowerIndicator:※
Ear Temperature Key: for the use of the ear temperature measuring
Ok Key、Left Key、and right Key: for the use of the high/low temperature alarm setting
Power Key: for the use of the lasting armpit temperature measuring
Power Indicator: for the use of the easy identification of the Receiver at dark
Note: This product is designed without a protective covering on the Ear Monitor. Clean with
alcohol after each use.
Left Key
Right Key
OK Key
Power Key
Ear
Temperature
Key
Power Indicator

3
(2)The LCD Display of the Receiver
(3) The Armband
Battery Installation:
Using a coin or screw-driver, turn counter-clockwise to open the battery cover. To close the
cover turn clockwise.
Note: This product is made of a silicone gel. Clean the product surface of the Armband using
water and a tissue. Do not immerse Armband into water.
Power Key
Power Indicator
Temperature Sensor
Armpit Temperature Status
Ear Temperature
Indicator Elephant Indicator
℃/℉
Temperature Indicator
High/Low Temperature
Alarm Setting
Wireless
Transmission
Indicator
Receiver Battery Indicator
Armband Battery
Indicator

4
2. Operating Instructions
(1)Ear Temperature Measuring:
Step 1. Press "Ear Temperature Key" for 2 seconds until the "Elephant Indicator" and the "Ear
Temperature Indicator" begin to flash.
Step 2. When the "Elephant Indicator" stops flashing it has a full power supply. Then, insert
the Ear Monitor into the ear of the patient. Press and hold the "Ear Temperature Key"
until it beeps once, and then record the ear temperature of the patient which is displayed
on the screen.
Step 3. The Receiver will turn off automatically after 15 seconds.
Notes: The Receiver will turn off automatically in 30 seconds without any operation.
(2)Armpit Temperature Measuring:
uArmpit Temperature Measuring:
Step 1.Press the "Power Key" for 2 seconds until the green light flashes every 4 seconds.
Step 2. Repeat Step 1. The display will show armpit temperature. It also indicates that the
wireless transmission is operating.
Step 3. Place Temperature Sensor "face up" and fasten the Armband securely to upper-arm,
near the armpit.
Step 4. Record the patient's temperature. Allow 3 to 5 minutes to accurately assess temperature
stability. The Display will show the current temperature readings every 12 seconds
allowing the operator to accurately determine the average temperature of the patient.
Step 5. To turn the Receiver off, press the "Power Key" for two seconds and wait for one
"beep" to turn off Receiver Display screen. Remove Armband from patient's arm and
press the "Power Key" and wait until the red light blinks once to indicate that the
Armband is turned off.
vTemperature Alarm Setting:
The operator can set both high and low temperature alarm signals. When applicable, the
Receiver will exhibit a series of "Beeps" alerting the operator to take appropriate action. The

5
alarm setting procedures are as follows:
Step1. High temperature setting: Press the “OK Key”for 2 seconds then the Receiver Beeps
twice to get into the temperature alarm setting mode. The Display shows “HI”and
the Default figures flashing on it.
Step2. Press “Right Key” or “Left Key” to adjust the alarm temperature setting. The
temperature is adjusted by 0.5℃(or 1℉) a time such as 38.5,39,39.5 and so on, then
press “OK Key”to finish setting.
Step3. Low temperature setting: Repeat Step1, press the “OK Key, ”when the “HI”and the
Default figures flashing on it, to get into the “LO”and the Default figures flashing on
the Display.
Step4. Press “Right Key” or “Left Key” to adjust the alarm temperature setting (see Step 2).
Note:
®The Default:The Default figures of the temperature alarm setting are HI:38℃and LO:34℃
(or HI:100℉and LO:93℉)and the Receiver will take these figures as the
Temperature Alarm Setting without any change in advance. The high
temperature alarm ranges from 32 to 42℃(or 96 to 104℉); the low
temperature alarm ranges from 32 to 34.5℃(or 89 to 96℉).
®Unintentionally Pressing function:The receiver will return to the temperature monitoring
mode and without change any setting if the operations mentioned above are
not finished within 10 seconds.
®Priority Alarm processing:The product is designed to process the alarm situation prior to the
temperature alarm setting model, or any other operations. Without saving any
setting if not pressing the “OK Key. ”the operator is better off to operate
temperature alarm setting with the full power supply.
®Please re-set the High/Low temperature alarm setting after replacing the batteries, or the
Receiver will get the default as the temperature alarm setting.
wCheck the High/Low temperature alarm setting:
The figures of “HI” and “LO” on the LCD Display show the setting of the High/Low
temperature alarm set by the operator.

6
xAbnormal Temperature Alarm:
®Alarm:The High/Low Temperature Alarm Setting of the Display will be flashing on the
“HI”and “LO”and their related figures when the temperature of a patient out of the
temperature alarm setting. That is, the “HI”and the figures are flashing and vice versa. The
Receiver will “Beep, Beep, Beep, Beep”every 2 seconds to inform the operator to take
adequate actions.
®Lasting alarm:The Receiver will check every 10 minutes the temperature of a patient if or
not out of the temperature alarm setting. The Receiver will keep noticing the operator to
take adequate actions via the lasting Beeps if out of the temperature alarm setting. Press any
key on the Receiver to stop Beep alarm.
Note:
1. In case that the original temperature of the Receiver lowers the low temperature alarm
setting then starts the alarm system, this product, when power on, will trigger the low
temperature alarm system after the normal temperature higher than that of the low
temperaturealarmsetting by 0.5 .℃
2. Itmay cause low temperature alarm when the Armband got off. Please check immediately
the patient and take adequate setting to the armband.

7
3. The Instructions of Indicators
Armband Power Indicator
Light Status Flashing
Green Normal 4 seconds each
Orange Low Volt 4 seconds each
Red Power Off One blink then power off
Low Battery Alarm
(1) Receiver Battery Indicator:
Power Supply Status
Receiver Battery
Indicator
Alarm sounds
Full power supply Full battery No sounds
Low power supply Flashing on the
Indicator
Beep twice /10 seconds
(2) Armband Battery Indicator:
Power Supply
Status
Armband Battery Indicator Alarm sounds
Full power supply Full battery No sounds
Low power supply Flashing on the Indicator
Beep twice /10 seconds

8
Poor Signal Warning
1. The Temperature Indicator shows “---”on theLCDDisplay oftheReceiverwhen failed℃
to receive the signal from the Armband after turning on the Receiver and then it will Beep
twice per 10 seconds. Please reset the Receiver to start receiving the signal from the
Armband.
Status Temperature Indicator
Alarm sounds
Poor signal ---℃Beep twice /10 seconds
PS. The LCD Display shows ”---”on it when Beeping.℃
2.Poor Signal Trouble Shooting:
Please move the Receiver more closed to the Armband then wait for the LCD Display of the
Receiver shows that the signal from the Armband is received. If the poor signal status still exits,
please reset both the Receiver and the Armband.
“Beep, Beep”“Beep, Beep”“Beep, Beep”“Beep, Beep”… ..

9
4. Importance Precautions
1. This product is designed to function properly under the conditions of the surrounding
temperaturebetween 15 to 40 , and therelativehumidity of95%and lower. Pleasedo not℃
use this product when temperature and humidity is out of the ranges above.
2. The transmission distance of this product can be reached to 30 meters without any obstacle.
3. In case to interfere the precision medical facilities in the hospital, please do not use this
product in it.
4. Please follow the manual to carefully operate this product.
5. The main function of this product is to alert the care-taker when the patient under the
abnormal temperature. The measurement, however, can sometimes be influenced by the
surrounding temperature. ONLY do the readings of this product are for reference, and the
medical attention from a qualified physician should be still sought for actual diagnosis.
6. Please pay much attention on the child with using this product. Please also keep out of reach
of children and place it on a higher position.
5.Specifications
Receiver Armband
Power supply Two A4 batteries and up to
80-100 hours of lasting
operation
Power supply One 3Volt lithium button
type (CR2032) and up to
72-96 hours of lasting
operation
Dimensions
(mm)
156H*42W*39D Dimensions
(mm)
136H*85W*9.5D
Weight 88g Weight 25g
Operating
temperature
15~40℃
Notice before using:
1. Keep out of using this product after exercising, bathing, having meals, and taking
walk within 30 minutes.
2. Make sure the sweat under the armpit of a child is wiped before using this product,
especially for the children with sweaty.

10
Temperature
transmission
frequency
Every 12 seconds
Valid
temperature
alarm ranges
HI:35-42℃(96-104 )℉LO:32-34.5℃(89-96 )℉
Transmission
frequency
2.4 Ghz
Radio
modulation
technique
FSK
Transmission
distance
20 meters
Armpit
temperature
precision
±0.1℃
Ear
temperature
precision
±0.2℃
Notice : The changes or modifications not expressly approved by the party
Responsible for compliance could void the user’s authority to operate the
equipment.
IMPORTANT NOTE: To comply with the FCC RF exposure compliance requirements, no
change to the antenna or the device is permitted. Any change to the
antenna or the device could result in the device exceeding the RF
exposure requirements and void user’s authority to operate the device.

11
General Agent :RIO FLEXON TECHNOLOGY CO., LTD
15 Fl, No 868-2 Chung-Cheng Rd, Chung Ho, Taipei County
0800 Customer Direct Line﹕0800-800306
Fax Number﹕02-82218198
E-mail:service@rio-flexon.com.tw
http://www.rio-flexon.com.tw
Attached behind the warranty card
Table of contents