6 Series OUTPOST®Wireless Callbox Basic Operation
2Have questions? Call 800-USA-1-USA (800-872-1872) or visit our website at www.ritron.com
O
PERATING THE
6
S
ERIES
O
UTPOST
®
C
ALLBOX WITH
F
ACTORY
D
EFAULT
S
ETTINGS
....................................................................
The 6 Series OUTPOST®Callbox Factory Default setting
is with Automatic Turn Off ENABLED. This means the
callbox is OFF and will not receive a call until the callbox
first initiates a call.
In Automatic Turn Off mode the callbox automatically
shuts off whenever there is “no activity” for ten (10)
seconds.
To Initiate a Call
Press and hold the ON/PTT Button. The callbox will send
a unique CALL TONE to alert radio equipped personnel.
This CALL TONE will also be heard at the callbox.
Listen for the “beep”, then begin speaking into the MIC.
For best communication, the caller should be 3 feet or
less from the microphone.
To Receive a Call
1. When you have finished speaking, release the
ON/PTT Button.
2. Any reply will be heard through the callbox speaker. If
a call is not received within 10 seconds of releasing
the ON/PTT Button and there is no activity on the
channel, the callbox will sound a low double tone and
turn-off automatically. This automatic turn-off feature
is designed to conserve battery life.
Operation Notes
The 6 Series OUTPOST®must be powered with D-cell
Alkaline batteries ONLY, or alternatively, with an external
12 VDC power supply, order Ritron model RPS-EXPO
110 VAC to 12 VDC cube power supply. When using an
external 12 VDC supply, Alkaline or NiCd batteries can
be used as back-up. See page 3.
If there has been no activity for 10 seconds, i.e. either
the ON/PTT Button has not been pressed or a call has
not been received, the unit automatically shuts OFF.
Low Battery Alert
The callbox will transmit an Alert Tone at the end of each
transmission when the batteries approach end-of-life. This
allows sufficient time for you to replace the batteries and
assure uninterrupted service.
E
XPOSURE TO
R
ADIO
F
REQUENCY
E
NERGY
...................................
These products generate radio frequency (RF) energy when
the ON/PTT button on the front of the unit is depressed.
These products have been evaluated for compliance with
the maximum permissible exposure limits for RF energy at
the maximum power rating of the unit when using antennas
available from RITRON.
These products are not to be used by the general public in
an uncontrolled environment unless compliance with the
Uncontrolled / General Population limits for RF exposure
can be assured.
Antennas other than those available from RITRON listed
below have not been tested for compliance and may or may
not meet the exposure limits at the distances given. Higher
gain antennas are capable of generating higher fields in the
strongest part of their field and would, therefore, require a
greater separation from the antenna.
RQX-456: For both the AFB-1545 and RAM-1545
antennas, at the 20 cm (7.9 inches) minimum expected
separation distance and greater, the maximum RF exposure
is well below the General Population / Uncontrolled limits.
RQX-156: To comply with the General Population /
Uncontrolled limits, all persons must be at least 7.9 inches
(20 cm) from the AFB-1545 antenna which is supplied by
RITRON to be attached directly to the top of the unit. For the
RITRON RAM-1545 magnet mount antenna, which can be
located away from the unit, all persons must be at least 10.8
inches (28 cm) from the antenna.
To limit exposure to RF energy to levels below the limit,
please observe the following:
• Use only the antenna(s) available from RITRON for
these models. DO NOT operate the radio without an
antenna.
• Keep talk times as short and infrequent as possible. DO
NOT depress the ON/PTT button when not actually
wishing to transmit. These radios are equipped with an
internal timer to limit continuous transmit times.
• When transmitting, make certain that the distance limits
for the particular model in use are observed.
• DO NOT allow children to operate the radio.
When used as directed, this series of radios is designed to
comply with the FCC’s RF exposure limits for “Uncontrolled /
General Population”. In addition, they are designed to
comply with the following Standards and Guidelines:
• FCC OET Bulletin 65, Edition 97-01, Supplement C,
Evaluating Compliance with FCC Guidelines for Human
Exposure to Radio Frequency Electromagnetic Fields.
• American National Standards Institute (C95.1-1992),
IEEE Standard for Safety Levels with Respect to Human
Exposure to Radio Frequency Electromagnetic Fields, 3
kHz to 300 GHz.
• American National Standards Institute (C95.3-1992),
IEEE Recommended Practice for the Measurement of
Potentially Hazardous Electromagnetic Fields-RF and
Microwave.