Pop-Up Wizard
The Wizard routine will display factory default settings. Each setting will
display for ten seconds. Use the or buttons to change the setting.
Settings that are not changed will operate with the values that are displayed.
To fast forward through the Wizard, press Edit Schedule. The Wizard can be
exited by pressing Start/Stop Schedule. This will save the settings and place
the thermostat into operation.
Use this chart to write down the desired settings before applying power.
Displayed Details Default Change To
SCAL (choose F° or C°) °F _______
CLOC* (choose 12 or 24 hour) 12 _______
LITE (1 = always on, 0 = off) 0 _______
DIFF (differential, set between 0.5 to 3.0 F°
or 0.5 to 1.5 C°) 1F° _______
DIF2** (2nd stage differential,
added to first stage differential) 2F° _______
DLY2** (2nd stage delay, in minutes) 20 _______
DEDB (auto changeover deadband
in degrees) 3F° _______
HI (heat setting limit in degrees) 90°F _______
LO (cool setting limit in degrees) 45°F _______
VAC HEAT* (vacation heat setpoint in degrees) 62°F _______
VAC COOL* (vacation cool setpoint in degrees) 85°F _______
CHECK*** (check filter timer in hours) OFF _______
CYCL (compressor short cycle delay in minutes) 5 _______
CAL (calibration offset in degrees) 0 _______
* Not displayed on RS4000 and RS6000 models.
** Will not be displayed if the thermostat is single stage.
*** On RS4000 models, the Filter Check feature can be turned to OFF (0) or ON (1).
The number of hours cannot be set.
After the Wizard has configured the thermostat, the settings can be edited by
pressing and simultaneously. This will allow you to change settings.
Factory settings that have not been changed will use the default settings
for operation.
Additional Default Settings for RS4000
The RS4110 and RS4220 are single setpoint non-programmable (no clock)
thermostats and do not have a schedule.
Default settings that are not set in the Pop-Up Wizard are:
The fan setting is auto.
The setpoint is 70°F.
The keypad has no password protection.