RocketLinx ES8105 Series User manual

Quick Installation Guide
ES8105 and ES8105F
www.comtrol.com
2000553 Rev C
Comtrol Customer Service
Contact Method Web Address or Phone Number
Support http://www.comtrol.com/pub/en/support
Downloads ftp://ftp.comtrol.com/html/ES8105.htm
Web Site http://www.comtrol.com
Phone 763.957.6000
You can use one of the following methods to contact Comtrol Corporation.
45
IEEE organization recommends maximum optical fiber cable distances as defined in
the following table:
ROCKETLINX ES8105
Industrial Ethernet Switch
The following table provides information about optical fiber cable attenuation:
Fiber Type
Wavelength
Attenuation /km *1
Attenuation /km *2
Connector
Loss
Splice
Loss
Multi-Mode
50/125um
850nm
1310mm 3.5dBm
1.5dBm 2.5dBm
0.8dBm 0.75dBm 0.1dBm
Multi-Mode
62.5/125um
850nm
1310nm 3.5dBm
1.5dBm 3.0dBm
0.7dBm 0.75dBm 0.1dBm
Single-Mode
9/125um 1310nm 0.4dBm 0.35dBm 0.75dBm 0.1dBm
Single-Mode
9/125um 1550nm 0.3dBm 0.22dBm 0.75dBm 0.1dBm
*1. These values are per TIA/EIA and other industrial specifications.
*2. These values are an example of the performance that can be obtained with a new fiber installation.
Standard
Data Rate
(Mbps)
Cable Type
IEEE Standard
Distance
10Base-FL 10
850nm, 50/125um or 62.5/125um
Multi-mode optical fiber cable 2km
100Base-FX 100
1310nm, 50/125um or 62.5/125um
Multi-mode optical fiber cable 2km
100Base-SX 100
850nm, 50/125um or 62.5/125um
Multi-mode optical fiber cable 300m
1000Base-SX 1000
850nm, 50/125um
Multi-mode optical fiber cable
850nm, 62.5/125um
Multi-mode optical fiber cable
550m
220m
1000Base-LX 1000
1310nm, 50/125um or 62.5/125um
Multi-mode optical fiber cable
1310nm, 9/125um
Single-mode optical fiber cable
550m
5km
1000Base-LH 1000
1550nm,9/125um
Single-mode optical fiber cable 70km

Introduction
The RocketLinx ES8105/ES8105F series of industrial Ethernet switches provide three
models:
ES8105 supports five 10/100BASE-TX ports
ES8105F-Multi-Mode: supports four 10/100BASE-TX ports and one
100BASE-FX Ethernet port
ES8105F-Single-Mode: supports four 10/100BASE-TX ports and one
100BASE-FX Ethernet port
The RocketLinx ES8105 series provides a slim industrial design to save rail space for
compact system requirements. The ES8105 series is enclosed in an industrial-grade
aluminum case with IP30 standard protection. It provides one relay output to alarm
port link failure events, which is enabled and disabled by a DIP switch.
Refer to the Comtrol web site for specification information. For more detailed
installation information, see the RocketLinx ES8105/ES8105F User Guide, which is
available at: ftp://ftp.comtrol.com/html/ES8108_docs.htm.
Wiring the Power Inputs
1. Insert the positive and negative wires into the power V+ and V- contacts on the
terminal block connector.
2. Tighten the wire-clamp screws to prevent the wires from being loosened.
Note: The recommended working voltage is 24VDC (18- 32VDC)
or 18VAC (18-27VAC).
Wiring the Relay Output
The relay output alarm contacts are on the terminal block
connector as shown in the figure.
If you insert the wires and enable the DIP switch for the port,
the relay output alarm will detect any port failures, and form
a short circuit. The alarm relay output is Normal Open.
Enabling the Event Alarm
Use this table to set the DIP switch for the relay output alarm.
123
r
t,
m
m
.
This is a Class 1 Laser/LED product.
Do not stare into the Laser/LED Beam.
ATTENTION
!
RX
TX
RX
TX
Cable Wiring(SC to SC)
RX A TX B
TX A RX B
AB
Pin Status Description
1-5 On Enables the port link failure alarm on this port.
Off Disables the port link failure alarm on this port.
4
NO
123 5
Grounding the ES8105/ES8105F
There is one grounding screw on the bottom side of the ES8105/ES8105F. Loosen the
screw and connect a ground wire from the ES8105/ES8510F to a grounded surface to
ensure safety and prevent noise.
Mounting the Unit
You can mount the ES8105 series on a DIN rail.
Connecting the Ethernet Port
Connect one end of an Ethernet cable into the Ethernet port of the ES8105/ES8105F
and the other end to the attached networking device. The Fast Ethernet ports support
10BASE-T and 100BASE-TX, full- or half-duplex modes.
The Fast Ethernet ports automatically detect the signal from the connected devices to
negotiate the link speed and duplex mode. Auto MDI/MDIX allows you to connect
another switch, hub, or workstation without changing straight-through or crossover
cables. Crossover cables cross-connect the transmit lines at each end to the received
lines at the opposite end.
The Ethernet cables use Pins 1, 2, 3, and 6 of an 8-pin RJ45 connector. The signals of
these pins are converted by the automatic MDIX function, as shown in the following
table:
3 TD+
6 TD- 3 RD+
6 RD-
Switch Router or PC
1 RD+
2 RD- 1 TD+
2 TD-
Straight-Through Cabling Schematic
3 TD+
6 TD- 3 TD+
6 TD-
Switch Switch
1 RD+
2 RD- 1 RD+
2 RD-
Crossover Cabling Schematic
Pin MDIX Signals MDI Signals
1 RD+ TD+
2 RD- TD-
3 TD+ RD+
6 TD- RD-
The LINK/ACT LED is lit when the cable is correctly connected. The LINK/ACT LED is
lit yellow for a 10BASE-TX Ethernet connection or green for a 100BASE-TX Ethernet
connection. Always make sure that the cables between the switches and attached
devices (for example, switch, hub, or workstation) are less than 100 meters (328 feet).
Connecting the Fiber Port (ES8105F)
Connect the fiber port on the ES8105F to another fiber Ethernet device using the
following information.
A wrong connection will cause the fiber port not to work properly.
The fiber connector is a standard connector or square connector (SC).
Note: In the IEEE standard, it suggests the available transmission distance is 2KM for
62.5/125um fiber optical cable in 1310nm wave length. Actually, the attenuation
of Multi-Mode 62.5/125um optical fiber cable is 1.5dBm/km and the maximum link
distance can be up to 4 to 5km.
Mode Cable Type Wavelength Transmit
Power
(min.)
Transmit
Power
(max.)
Receive
Sensitivity
(max.)
Receive
Sensitivity
(min.)
Min. Launch
Power –Max.
Receive
Sensitivity
Distance(km)
Multi 50/125um
62.5/125um 1310nm -20dBm -14dBm -31dBm 0dBm 11dBm 2km
Note (below)
Single 8-10/125um 1310nm -15dBm -8dBm -34dBm -8dBm 19dBm 30km

Introduction
The RocketLinx ES8105/ES8105F series of industrial Ethernet switches provide three
models:
ES8105 supports five 10/100BASE-TX ports
ES8105F-Multi-Mode: supports four 10/100BASE-TX ports and one
100BASE-FX Ethernet port
ES8105F-Single-Mode: supports four 10/100BASE-TX ports and one
100BASE-FX Ethernet port
The RocketLinx ES8105 series provides a slim industrial design to save rail space for
compact system requirements. The ES8105 series is enclosed in an industrial-grade
aluminum case with IP30 standard protection. It provides one relay output to alarm
port link failure events, which is enabled and disabled by a DIP switch.
Refer to the Comtrol web site for specification information. For more detailed
installation information, see the RocketLinx ES8105/ES8105F User Guide, which is
available at: ftp://ftp.comtrol.com/html/ES8108_docs.htm.
Wiring the Power Inputs
1. Insert the positive and negative wires into the power V+ and V- contacts on the
terminal block connector.
2. Tighten the wire-clamp screws to prevent the wires from being loosened.
Note: The recommended working voltage is 24VDC (18- 32VDC)
or 18VAC (18-27VAC).
Wiring the Relay Output
The relay output alarm contacts are on the terminal block
connector as shown in the figure.
If you insert the wires and enable the DIP switch for the port,
the relay output alarm will detect any port failures, and form
a short circuit. The alarm relay output is Normal Open.
Enabling the Event Alarm
Use this table to set the DIP switch for the relay output alarm.
123
r
t,
m
m
.
This is a Class 1 Laser/LED product.
Do not stare into the Laser/LED Beam.
ATTENTION
!
RX
TX
RX
TX
Cable Wiring(SC to SC)
RX A TX B
TX A RX B
AB
Pin Status Description
1-5 On Enables the port link failure alarm on this port.
Off Disables the port link failure alarm on this port.
4
NO
123 5
Grounding the ES8105/ES8105F
There is one grounding screw on the bottom side of the ES8105/ES8105F. Loosen the
screw and connect a ground wire from the ES8105/ES8510F to a grounded surface to
ensure safety and prevent noise.
Mounting the Unit
You can mount the ES8105 series on a DIN rail.
Connecting the Ethernet Port
Connect one end of an Ethernet cable into the Ethernet port of the ES8105/ES8105F
and the other end to the attached networking device. The Fast Ethernet ports support
10BASE-T and 100BASE-TX, full- or half-duplex modes.
The Fast Ethernet ports automatically detect the signal from the connected devices to
negotiate the link speed and duplex mode. Auto MDI/MDIX allows you to connect
another switch, hub, or workstation without changing straight-through or crossover
cables. Crossover cables cross-connect the transmit lines at each end to the received
lines at the opposite end.
The Ethernet cables use Pins 1, 2, 3, and 6 of an 8-pin RJ45 connector. The signals of
these pins are converted by the automatic MDIX function, as shown in the following
table:
3 TD+
6 TD- 3 RD+
6 RD-
Switch Router or PC
1 RD+
2 RD- 1 TD+
2 TD-
Straight-Through Cabling Schematic
3 TD+
6 TD- 3 TD+
6 TD-
Switch Switch
1 RD+
2 RD- 1 RD+
2 RD-
Crossover Cabling Schematic
Pin MDIX Signals MDI Signals
1 RD+ TD+
2 RD- TD-
3 TD+ RD+
6 TD- RD-
The LINK/ACT LED is lit when the cable is correctly connected. The LINK/ACT LED is
lit yellow for a 10BASE-TX Ethernet connection or green for a 100BASE-TX Ethernet
connection. Always make sure that the cables between the switches and attached
devices (for example, switch, hub, or workstation) are less than 100 meters (328 feet).
Connecting the Fiber Port (ES8105F)
Connect the fiber port on the ES8105F to another fiber Ethernet device using the
following information.
A wrong connection will cause the fiber port not to work properly.
The fiber connector is a standard connector or square connector (SC).
Note: In the IEEE standard, it suggests the available transmission distance is 2KM for
62.5/125um fiber optical cable in 1310nm wave length. Actually, the attenuation
of Multi-Mode 62.5/125um optical fiber cable is 1.5dBm/km and the maximum link
distance can be up to 4 to 5km.
Mode Cable Type Wavelength Transmit
Power
(min.)
Transmit
Power
(max.)
Receive
Sensitivity
(max.)
Receive
Sensitivity
(min.)
Min. Launch
Power –Max.
Receive
Sensitivity
Distance(km)
Multi 50/125um
62.5/125um 1310nm -20dBm -14dBm -31dBm 0dBm 11dBm 2km
Note (below)
Single 8-10/125um 1310nm -15dBm -8dBm -34dBm -8dBm 19dBm 30km

Introduction
The RocketLinx ES8105/ES8105F series of industrial Ethernet switches provide three
models:
ES8105 supports five 10/100BASE-TX ports
ES8105F-Multi-Mode: supports four 10/100BASE-TX ports and one
100BASE-FX Ethernet port
ES8105F-Single-Mode: supports four 10/100BASE-TX ports and one
100BASE-FX Ethernet port
The RocketLinx ES8105 series provides a slim industrial design to save rail space for
compact system requirements. The ES8105 series is enclosed in an industrial-grade
aluminum case with IP30 standard protection. It provides one relay output to alarm
port link failure events, which is enabled and disabled by a DIP switch.
Refer to the Comtrol web site for specification information. For more detailed
installation information, see the RocketLinx ES8105/ES8105F User Guide, which is
available at: ftp://ftp.comtrol.com/html/ES8108_docs.htm.
Wiring the Power Inputs
1. Insert the positive and negative wires into the power V+ and V- contacts on the
terminal block connector.
2. Tighten the wire-clamp screws to prevent the wires from being loosened.
Note: The recommended working voltage is 24VDC (18- 32VDC)
or 18VAC (18-27VAC).
Wiring the Relay Output
The relay output alarm contacts are on the terminal block
connector as shown in the figure.
If you insert the wires and enable the DIP switch for the port,
the relay output alarm will detect any port failures, and form
a short circuit. The alarm relay output is Normal Open.
Enabling the Event Alarm
Use this table to set the DIP switch for the relay output alarm.
123
r
t,
m
m
.
This is a Class 1 Laser/LED product.
Do not stare into the Laser/LED Beam.
ATTENTION
!
RX
TX
RX
TX
Cable Wiring(SC to SC)
RX A TX B
TX A RX B
AB
Pin Status Description
1-5 On Enables the port link failure alarm on this port.
Off Disables the port link failure alarm on this port.
4
NO
123 5
Grounding the ES8105/ES8105F
There is one grounding screw on the bottom side of the ES8105/ES8105F. Loosen the
screw and connect a ground wire from the ES8105/ES8510F to a grounded surface to
ensure safety and prevent noise.
Mounting the Unit
You can mount the ES8105 series on a DIN rail.
Connecting the Ethernet Port
Connect one end of an Ethernet cable into the Ethernet port of the ES8105/ES8105F
and the other end to the attached networking device. The Fast Ethernet ports support
10BASE-T and 100BASE-TX, full- or half-duplex modes.
The Fast Ethernet ports automatically detect the signal from the connected devices to
negotiate the link speed and duplex mode. Auto MDI/MDIX allows you to connect
another switch, hub, or workstation without changing straight-through or crossover
cables. Crossover cables cross-connect the transmit lines at each end to the received
lines at the opposite end.
The Ethernet cables use Pins 1, 2, 3, and 6 of an 8-pin RJ45 connector. The signals of
these pins are converted by the automatic MDIX function, as shown in the following
table:
3 TD+
6 TD- 3 RD+
6 RD-
Switch Router or PC
1 RD+
2 RD- 1 TD+
2 TD-
Straight-Through Cabling Schematic
3 TD+
6 TD- 3 TD+
6 TD-
Switch Switch
1 RD+
2 RD- 1 RD+
2 RD-
Crossover Cabling Schematic
Pin MDIX Signals MDI Signals
1 RD+ TD+
2 RD- TD-
3 TD+ RD+
6 TD- RD-
The LINK/ACT LED is lit when the cable is correctly connected. The LINK/ACT LED is
lit yellow for a 10BASE-TX Ethernet connection or green for a 100BASE-TX Ethernet
connection. Always make sure that the cables between the switches and attached
devices (for example, switch, hub, or workstation) are less than 100 meters (328 feet).
Connecting the Fiber Port (ES8105F)
Connect the fiber port on the ES8105F to another fiber Ethernet device using the
following information.
A wrong connection will cause the fiber port not to work properly.
The fiber connector is a standard connector or square connector (SC).
Note: In the IEEE standard, it suggests the available transmission distance is 2KM for
62.5/125um fiber optical cable in 1310nm wave length. Actually, the attenuation
of Multi-Mode 62.5/125um optical fiber cable is 1.5dBm/km and the maximum link
distance can be up to 4 to 5km.
Mode Cable Type Wavelength Transmit
Power
(min.)
Transmit
Power
(max.)
Receive
Sensitivity
(max.)
Receive
Sensitivity
(min.)
Min. Launch
Power –Max.
Receive
Sensitivity
Distance(km)
Multi 50/125um
62.5/125um 1310nm -20dBm -14dBm -31dBm 0dBm 11dBm 2km
Note (below)
Single 8-10/125um 1310nm -15dBm -8dBm -34dBm -8dBm 19dBm 30km

Quick Installation Guide
ES8105 and ES8105F
www.comtrol.com
2000553 Rev C
Comtrol Customer Service
Contact Method Web Address or Phone Number
Support http://www.comtrol.com/pub/en/support
Downloads ftp://ftp.comtrol.com/html/ES8105.htm
Web Site http://www.comtrol.com
Phone 763.957.6000
You can use one of the following methods to contact Comtrol Corporation.
45
IEEE organization recommends maximum optical fiber cable distances as defined in
the following table:
ROCKETLINX ES8105
Industrial Ethernet Switch
The following table provides information about optical fiber cable attenuation:
Fiber Type
Wavelength
Attenuation /km *1
Attenuation /km *2
Connector
Loss
Splice
Loss
Multi-Mode
50/125um
850nm
1310mm 3.5dBm
1.5dBm 2.5dBm
0.8dBm 0.75dBm 0.1dBm
Multi-Mode
62.5/125um
850nm
1310nm 3.5dBm
1.5dBm 3.0dBm
0.7dBm 0.75dBm 0.1dBm
Single-Mode
9/125um 1310nm 0.4dBm 0.35dBm 0.75dBm 0.1dBm
Single-Mode
9/125um 1550nm 0.3dBm 0.22dBm 0.75dBm 0.1dBm
*1. These values are per TIA/EIA and other industrial specifications.
*2. These values are an example of the performance that can be obtained with a new fiber installation.
Standard
Data Rate
(Mbps)
Cable Type
IEEE Standard
Distance
10Base-FL 10
850nm, 50/125um or 62.5/125um
Multi-mode optical fiber cable 2km
100Base-FX 100
1310nm, 50/125um or 62.5/125um
Multi-mode optical fiber cable 2km
100Base-SX 100
850nm, 50/125um or 62.5/125um
Multi-mode optical fiber cable 300m
1000Base-SX 1000
850nm, 50/125um
Multi-mode optical fiber cable
850nm, 62.5/125um
Multi-mode optical fiber cable
550m
220m
1000Base-LX 1000
1310nm, 50/125um or 62.5/125um
Multi-mode optical fiber cable
1310nm, 9/125um
Single-mode optical fiber cable
550m
5km
1000Base-LH 1000
1550nm,9/125um
Single-mode optical fiber cable 70km

Quick Installation Guide
ES8105 and ES8105F
www.comtrol.com
2000553 Rev C
Comtrol Customer Service
Contact Method Web Address or Phone Number
Support http://www.comtrol.com/pub/en/support
Downloads ftp://ftp.comtrol.com/html/ES8105.htm
Web Site http://www.comtrol.com
Phone 763.957.6000
You can use one of the following methods to contact Comtrol Corporation.
45
IEEE organization recommends maximum optical fiber cable distances as defined in
the following table:
ROCKETLINX ES8105
Industrial Ethernet Switch
The following table provides information about optical fiber cable attenuation:
Fiber Type
Wavelength
Attenuation /km *1
Attenuation /km *2
Connector
Loss
Splice
Loss
Multi-Mode
50/125um
850nm
1310mm 3.5dBm
1.5dBm 2.5dBm
0.8dBm 0.75dBm 0.1dBm
Multi-Mode
62.5/125um
850nm
1310nm 3.5dBm
1.5dBm 3.0dBm
0.7dBm 0.75dBm 0.1dBm
Single-Mode
9/125um 1310nm 0.4dBm 0.35dBm 0.75dBm 0.1dBm
Single-Mode
9/125um 1550nm 0.3dBm 0.22dBm 0.75dBm 0.1dBm
*1. These values are per TIA/EIA and other industrial specifications.
*2. These values are an example of the performance that can be obtained with a new fiber installation.
Standard
Data Rate
(Mbps)
Cable Type
IEEE Standard
Distance
10Base-FL 10
850nm, 50/125um or 62.5/125um
Multi-mode optical fiber cable 2km
100Base-FX 100
1310nm, 50/125um or 62.5/125um
Multi-mode optical fiber cable 2km
100Base-SX 100
850nm, 50/125um or 62.5/125um
Multi-mode optical fiber cable 300m
1000Base-SX 1000
850nm, 50/125um
Multi-mode optical fiber cable
850nm, 62.5/125um
Multi-mode optical fiber cable
550m
220m
1000Base-LX 1000
1310nm, 50/125um or 62.5/125um
Multi-mode optical fiber cable
1310nm, 9/125um
Single-mode optical fiber cable
550m
5km
1000Base-LH 1000
1550nm,9/125um
Single-mode optical fiber cable 70km
This manual suits for next models
1
Table of contents