Rockford Systems PROTECTOR Series User manual

5795 Logistics Parkway • Rockford Systems, Illinois 61109 • Toll Free 1-800-922-7533 (USA only) • Phone (815) 874-7891
Manual No. KSL306
INSTALLATION MANUAL FOR
PROTECTOR SERIES LIGHT CURTAINS
IMPORTANT: PLEASE REVIEW THIS ENTIRE
PUBLICATION BEFORE INSTALLING, OPERATING
OR MAINTAINING THIS DEVICE.

TABLE OF CONTENTS
Protector Series Light Curtains
Rockford Systems, LLC
2Call: 1-800-922-7533
TABLE OF CONTENTS
OVERVIEW................................................................................... 3
Important — Read before Proceeding!....................................... 3
Warnings and Cautions ............................................................. 3
STANDARDS AND REGULATIONS ................................................ 4
Applicable U.S. Standards ......................................................... 4
Applicable OSHA Regulations..................................................... 4
International/European Standards............................................... 4
PRODUCT OVERVIEW................................................................... 5
Protector Series Light Curtain Overview................................... 5-6
Appropriate Applications and Limitations .................................... 6
Components ........................................................................ 7-16
Operating Features............................................................. 16-19
SPECIFICATIONS ....................................................................... 20
General Specifications............................................................. 20
Receiver Specifications............................................................ 21
Emitter Specifications.............................................................. 21
Dimensions........................................................................ 22-23
MECHANICAL INSTALLATIONS .................................................. 24
Mechanical Installation Considerations ................................ 24-32
Mounting System Components ........................................... 33-37
ELECTRICAL INSTALLATION AND TESTING................................ 38
Routing Cordsets................................................................ 38-39
Initial Electrical Connections..................................................... 39
Initial Checkout Procedure ................................................. 40-45
Electrical Connections to the Guarded Machine ................... 46-49
Wiring Diagrams ................................................................ 50-54
SYSTEM OPERATION................................................................. 55
Security Protocol..................................................................... 55
Status Indicator....................................................................... 55
Normal Operation.................................................................... 57
Periodic Checkout Requirements.............................................. 57
CHECKOUT PROCEDURES ......................................................... 58
Schedule of Checkouts............................................................ 58
Commissioning Checkout ................................................... 58-59
TROUBLESHOOTING .................................................................. 60
Lockout Conditions.................................................................. 60
Recovery Procedures.......................................................... 60-62
Electrical and Optical Noise ..................................................... 63
PRODUCT SUPPORT AND MAINTENANCE.................................. 64
Replacement Parts.................................................................. 64
Cleaning................................................................................. 64
Manufacturing Date................................................................. 64
Disposal ................................................................................. 64
Terms & Conditions of Sale ..................................................... 65
Protector Series Light Curtains Warranty .................................. 66
CASCADE .................................................................................. 67
Overview of Cascading ............................................................ 67
Determining Interconnect Cordset Lengths .......................... 68-69
Response Time for Cascaded Light Screens ............................. 70
Emergency Stop Buttons in Cascaded Systems.................... 71-72
Interlock Switches in Cascaded Systems .................................. 73
Remote TEACH Fixed Blanking (Wiring) .................................... 74
ACCESSORIES ........................................................................... 75
Cordsets ........................................................................... 75-79
AC Interface Boxes.................................................................. 80
Universal (Input) Safety Modules .............................................. 81
Safety Controllers.................................................................... 81
Muting Module........................................................................ 81
Interface Modules ................................................................... 81
Contractors............................................................................. 81
Optional Mounting Brackets................................................ 82-83
Remote Blanking Key Switch Box............................................. 84
Alignment Aids........................................................................ 84
Snap-On Lens Shields............................................................. 84
Tubular Enclosures.................................................................. 85
Protector Series Light Curtains............................................ 85-87
MSM Series Corner Mirrors ..................................................... 88
SSM Series Corner Mirrors ................................................. 89-90
MSA Series Stands ................................................................. 90
Muting Accessories................................................................. 91
GLOSSARY ...........................................................................92-94

Rockford Systems, LLC
Call: 1-800-922-7533 3
IMPORTANT — READ BEFORE PROCEEDING!
OVERVIEW
© 2023 Rockford Systems, LLC All rights reserved. Not to be reproduced in whole or in part without written permission. Litho in U.S.A.
It is the responsibility of the machine designer, controls engineer, machine builder, machine operator, and/or maintenance personnel or electrician
to apply and maintain this device in full compliance with all applicable regulations and standards. The device can provide the required safeguarding
function only if it is properly installed, properly operated, and properly maintained. This manual attempts to provide complete installation, operation,
and maintenance instruction. Reading the manual in its entirety is highly recommended to ensure proper understanding of the operation, installation,
and maintenance. Please direct any questions regarding the application or use of the device to Banner Engineering.
For more information regarding U.S. and international institutions that provide safeguarding application and safeguarding device performance
standards, see Standards and Regulations on page 4.
The precautions and statements used throughout this document are indicated by alert symbols and must be followed for the safe use of the Protector
Series Light Curtain. Failure to follow all precautions and alerts may result in unsafe use or operation. The following signal words and alert symbols
are defined as follows:
WARNING:
• The user is responsible for following these instructions.
• Failure to follow any of these responsibilities may potentially create a dangerous condition that could result in serious injury
or death.
• Carefully read, understand, and comply with all instructions for this device.
• Perform a risk assessment that includes the specific machine guarding application. Guidance on a compliant methodology can be found in
ISO 12100 or ANSI B11.0.
• Determine what safeguarding devices and methods are appropriate per the results of the risk assessment and implement per all applicable
local, state, and national codes and regulations. See ISO 13849-1, ANSI B11.19, and/or other appropriate standards.
• Verify that the entire safeguarding system (including input devices, control systems, and output devices) is properly configured and installed,
operational, and working as intended for the application.
• Periodically re-verify, as needed, that the entire safeguarding system is working as intended for the application.
WARNINGS AND CAUTIONS
Signal Word Definition Symbol
WARNING: Warnings refer to potentially hazardous situations which, if not avoided, could result
in serious injury or death.
CAUTION: Cautions refer to potentially hazardous situations which, if not avoided,
could result in minor or moderate injury.
These statements are intended to inform the machine designer and manufacturer, the end user, and maintenance personnel, how to avoid
misapplication and effectively apply the Protector Series Light Curtain to meet the various safeguarding application requirements. These individuals
are responsible to read and abide by these statements.
SECTION 1 — IN GENERAL
Protector Series Light Curtains
The applications described in this manual are for instructional and informational purposes only; the photos in this manual are for illustrative purposes
only. They may not represent actual usage. This manual has been carefully checked for accuracy and is thought to be fully consistent with the
products described herein. However, Rockford Systems, LLC does not assume liability for the contents of this publication or for the use of any
products described herein. Rockford Systems, LLC reserves the right to make changes to the products and documentation without further notice.
This document contains proprietary information protected by copyright. No part of this manual may be reproduced, transmitted, stored in a retrieval
system, or translated into any language, in any form or by any means without prior written permission from Rockford Systems, LLC, 5795 Logistics
Parkway, Rockford, Illinois 61109. Rockford Systems reserves the right to make changes or revisions to the material contained in this manual and
cannot be held liable for incidental or consequential damages resulting from the furnishing, performance or use of this material.

TABLE OF CONTENTS
Protector Series Light Curtains
Rockford Systems, LLC
4Call: 1-800-922-7533
SECTION 2 — STANDARDS AND REGULATIONS
Protector Series Light Curtains
APPLICABLE U.S. STANDARDS
B11.0 Safety of Machinery, General Requirements,
and Risk Assessment
B11.1 Mechanical Power Presses
B11.2 Hydraulic Power Presses
B11.3 Power Press Brakes
B11.4 Shears
B11.5 Iron Workers
B11.6 Lathes
B11.7 Cold Headers and Cold Formers
B11.8 Drilling, Milling, and Boring
B11.9 Grinding Machines
B11.10 Metal Sawing Machines
B11.11 Gear Cutting Machines
B11.12 Roll Forming and Roll Bending Machines
B11.13 Single- and Multiple-Spindle Automatic Bar and
Chucking Machines
B11.14 Coil Slitting Machines
B11.15 Pipe, Tube, and Shape Bending Machines
B11.16 Metal Powder Compacting Presses
B11.17 Horizontal Extrusion Presses
B11.18 Machinery and Machine Systems for the Processing
of Coiled Strip, Sheet, and Plate
B11.19 Performance Criteria for Safeguarding
B11.20 Manufacturing Systems
B11.21 Machine Tools Using Lasers
B11.22 Numerically Controlled Turning Machines
B11.23 Machining Centers
B11.24 Transfer Machines
R15.06 Safety Requirements for Industrial Robots and
Robot Systems
NFPA 79 Electrical Standard for Industrial Machinery
B155.1 Package Machinery and Packaging-Related Converting
Machinery — Safety Requirements
APPLICABLE OSHA REGULATIONS
OSHA Documents listed are part of: Code of Federal Regulations
Title 29, Parts 1900 to 1910
OSHA 29 CFR 1910.212 General Requirements for (Guarding of)
All Machines
OSHA 29 CFR 1910.147 The Control of Hazardous Energy
(lockout/tagout)
OSHA 29 CFR 1910.217 (Guarding of) Mechanical Power Presses
INTERNATIONAL/EUROPEAN STANDARDS
EN ISO 12100 Safety of Machinery – General Principles for Design
— Risk Assessment and Risk Reduction
ISO 13857 Safety of Machinery – Safety Distances to Prevent
Hazard Zones Being Reached
ISO 13850 (EN 418) Emergency Stop Devices, Functional Aspects
– Principles for Design
ISO 13851 Two-Hand Control Devices – Principles for Design and
Selection
IEC 62061 Functional Safety of Safety-Related Electrical, Electronic
and Programmable Control Systems
EN ISO 13849-1 Safety-Related Parts of Control Systems
EN 13855 (EN 999) The Positioning of Protective Equipment in
Respect to Approach Speeds of Parts of the Human Body
ISO 14119 (EN 1088) Interlocking Devices Associated with Guards
– Principles for Design and Selection
EN 60204-1 Electrical Equipment of Machines Part 1: General
Requirements
IEC 61496 Electro-sensitive Protection Equipment
IEC 60529 Degrees of Protection Provided by Enclosures
IEC 60947-1 Low Voltage Switchgear – General Rules
IEC 60947-5-1 Low Voltage Switchgear – Electromechanical
Control Circuit Devices
IEC 60947-5-5 Low Voltage Switchgear – Electrical Emergency
Stop Device with Mechanical Latching Function
IEC 61508 Functional Safety of Electrical/Electronic/Programmable
Electronic Safety-Related Systems
IEC 62046 Safety of Machinery – Applications of Protective
Equipment to Detect the Presence of Persons
ISO 3691-4 Industrial Trucks—Safety Requirements and
Verification, Part 4 Driverless Industrial trucks and their Systems
STANDARDS AND REGULATIONS
The list of standards below is included as a convenience
for users of this Rockford Systems device. Inclusion of the
standards below does not imply that the device complies
specifically with any standard, other than those specified in
the Specifications section of this manual.

Rockford Systems, LLC
Call: 1-800-922-7533 5
PROTECTOR SERIES LIGHT CURTAIN OVERVIEW
Rockford Systems Protector Series Light Curtain is a two-piece (emitter and receiver), redundant, microprocessor-controlled, opposed-mode
optoelectronic "light curtain" or "safety light screen". Models are available in 14 mm, 23 mm, or 40 mm resolution. Up to four pairs of SLLC.. model
emitters and receivers can be cascaded together.
Emitters have a row of synchronized modulated infrared (invisible) light-emitting diodes (LEDs) in a robust, compact metal housing. Receivers have
a corresponding row of synchronized photodetectors. The sensing field created by the emitter and receiver is called the "defined area"; its width
and height are determined by the length of the sensor pair and the distance between them. The sensing range spans:
• 280 mm to 1820 mm length models: 0.1 m to 12 m (4 in to 39 ft)
• 1890 mm to 2380 mm length models: 0.1 m to 10 m (4 in to 32.8 ft)
The range decreases with the use of corner mirrors and/or lens shields:
• Lens shields — approx 10% less range per shield
• Glass-surface mirrors — approx 8% less range per mirror
The length of the sensor pair (housing) is dependent on the model, with lengths available from 280 mm to 2380 mm (11 in to 93.7 in). The end to
end sensing design of the Protector Series Light Curtain, also known as "no blind zone" and "no dead zone," allows mounting with minimal or no
gaps in detection when using EZLSA-MBK-12 center-mount or EZLSA-MBK-16 side-mount brackets.
The Protector Series Light Curtain models have trip output (auto power-up and automatic reset). In typical operation, if any part of an operator's
body (or any opaque object) of more than a pre-determined cross section is detected, the solid-state output signal switching device (OSSD) safety
outputs turn Off. These safety outputs are connected to the guarded machine's final switching devices (FSDs) that control the machine primary
control elements (MPCEs), which immediately stop the motion of the guarded machine. When the defined area becomes clear, the OSSD outputs
are allowed to turn ON.
Protector Series Light Curtain sensors are extensively FMEA (Failure Mode and Effects Analysis) tested to establish an extremely high degree of
confidence that when properly installed, no system component (even if it should ever fail) can cause a failure to danger. Because of the dual scan
technology, Protector Series Light Curtain sensors are also highly immune to EMI, RFI, ambient light, weld flash, and strobe light.
Eight-conductor Protector Series Light Curtain systems (receivers with 8-pin pigtail QD or flying leads) do not require an external controller when
using the external device monitoring (EDM) function. This function ensures the fault detection capability required by U.S. Control Reliability and ISO
13849-1 Categories 3 or 4 and PL d or e for controlling final switching devices (FSDs) or Machine Primary Control Elements (MPCEs).
Protector Series Light Curtain shown without and with the optional EZLSA-K30LGR EZ-LIGHT
PRODUCT OVERVIEW
SECTION 3 — PRODUCT OVERVIEW
Protector Series Light Curtains

Rockford Systems, LLC
6Call: 1-800-922-7533
PROTECTOR SERIES LIGHT CURTAIN OVERVIEW
When configured with a five-conductor hookup, the Protector Series Light Curtain requires a self-checking safety module, safety controller, or safety
PLC/PES that conforms to the level of performance required by the risk assessment. Examples include the UM-FA-9A/-11A safety module, SC10-
2roe or XS/SC26-2 safety controller for applications requiring Control Reliability and/or ISO 13849-1 Categories 3 or 4 and PL d or e.
Electrical connections (power, ground, inputs and outputs) are made via M12 quick-disconnect cordsets or unique RD (removable disconnect)
cordsets, depending on model. A "System" as referred to in this manual, is defined as an emitter and its receiver, plus their cabling, or to a cascade
of emitters and their receivers and their cabling.
Available features include selectable scan code via hookup, an auxiliary fault output, a recessed exit window, and robust metal housing and end-
caps for industry leading durability.
Additional features on cascade models include automatic configuration of up to four sensor pairs (any length or resolution), optional Protector Series
Light Curtain indication (integral or remotely located) the ability to interface an E-Stop button or Interlocking switches (hard contacts), and remote
fixed blanking. All models require a supply voltage of +24 V dc ±15%.
Both emitter and receiver feature 7-segment Diagnostic Displays and individual LEDs to provide continuous indication of operating status,
configuration and error conditions. An adhesive Diagnostics label is provided that includes a summary of the operational and error codes. Active
Alignment (Segment) Indicators provide beam block information and easier installation. See Status Indicators on page 55 for more information.
APPROPRIATE APPLICATIONS AND LIMITATIONS
APPROPRIATE APPLICATIONS
The Protector Series Light Curtainability to perform its safeguarding function depends upon the appropriateness of the application and upon
its proper mechanical and electrical installation and interfacing to the guarded machine. If all mounting, installation, interfacing, and checkout
procedures are not followed properly, the Protector Series Light Curtain cannot provide the protection for which it was designed.
Protector Series Light Curtain is typically used for, but is not limited to, the following applications:
• Automated production equipment
• Robotic work cells
• Molding and power presses
• Assembly and packaging machines
• Lean manufacturing systems
WARNING:
• Read this Section Carefully Before Installing the System
• Failure to follow these instructions could result in serious injury or death.
• If all mounting, installation, interfacing, and checkout procedures are not followed properly, this Banner Engineering device cannot provide
the protection for which it was designed.
• The user is responsible for ensuring that all local, state, and national laws, rules, codes, or regulations relating to the installation and use
of this control system in any particular application are satisfied. Ensure that all legal requirements have been met and that all technical
installation and maintenance instructions contained in this manual are followed.
• The user has the sole responsibility to ensure that this Banner Engineering device is installed and interfaced to the guarded machine by
Qualified Persons, in accordance with this manual and applicable safety regulations. A Qualified person is a person who, by possession
of a recognized degree or certificate of professional training, or who, by extensive knowledge, training and experience, has successfully
demonstrated the ability to solve problems relating to the subject matter and work.
WARNING:
• Install System Only on Appropriate Applications
• Failure to follow these instructions could result in serious injury or death.
• Use Rockford System Protector Series Light Curtain only on machinery that can be stopped immediately after a stop signal is issued at any
point in the machine's stroke or cycle, such as part-revolution clutched machines. Under no circumstances may the Protector Series Light
Curtain be used on full-revolution clutched machinery or in unsuitable applications.
• If there is any doubt about whether or not your machinery is compatible with the Protector Series Light Curtain, contact Banner Engineering.
SECTION 3 — PRODUCT OVERVIEW
Protector Series Light Curtains

Rockford Systems, LLC
Call: 1-800-922-7533 7
EXAMPLES: INAPPROPRIATE APPLICATIONS
CONTROL RELIABILITY: REDUNDANCY AND SELF-CHECKING
COMPONENTS
MODELS
A Protector Series Light Curtain “System” refers to a compatible emitter and receiver of equal length and resolution (available in pairs or separately),
including cascaded sensors, and their cordsets. Mounting hardware may be included with each emitter and receiver, depending on model. Special-
purpose mounting brackets both for standalone pairs and for cascades are also available. Depending on the connection option, interfacing solutions
include IM-T-.. modules, redundant positively guided contactors, safety modules/controllers, and muting modules.
The 13 mm (0.5 in) minimum bend radius for all cordset models accommodates low-clearance installations; cords can exit to the left, right, or back
of the sensor, when mounting. The pigtail QD option is useful for connection to splitter cables or other QD cordsets.
If a Protector Series Light Curtain is installed for use as a perimeter guard (where a pass-through hazard may exist, see Reducing or Eliminating
Pass-Through Hazards on page 26), the dangerous machine motion can be initiated by normal means only after the safeguarded area is clear of
individuals and the Protector Series Light Curtain has been manually reset.
Do not use Protector Series Light Curtain in the following applications:
• With any machine that cannot be stopped immediately after a stop signal is issued, such as single-stroke (or full-revolution) clutched machinery
• With any machine with inadequate or inconsistent machine response time and stopping performance
• With any machine that ejects materials or component parts through the defined area
• In any environment that is likely to adversely affect photoelectric sensing efficiency. For example, corrosive chemicals or fluids or unusually severe levels of
smoke or dust, if not controlled, may degrade sensing efficiency
• As a tripping device to initiate or reinitiate machine motion (PSDI applications), unless the machine and its control system fully comply with the relevant
standard or regulation (see OSHA 29CFR1910.217, NFPA 79, ANSI B11.19, ISO 12100, IEC 60204-1, IEC 61496-1, or other appropriate standard)
Redundancy requires that Protector Series Light Curtain circuit components be backed up to the extent that, if the failure of a single component will
prevent effective machine stopping action when needed, that component must have a redundant counterpart which will perform the same function.
The Protector Series Light Curtain is designed with redundant microprocessors.
Redundancy must be maintained whenever the Protector Series Light Curtain is in operation. Because a redundant system is no longer redundant
after a component has failed, Protector Series Light Curtain is designed to monitor itself continuously. A component failure detected by or within the
self-checking system causes a stop signal to be sent to the guarded machine and puts the Protector Series Light Curtain into a Lockout condition.
A recovery from this type of Lockout condition requires:
• Replacement of the failed component (to restore redundancy)
• The appropriate reset procedure
The Diagnostic Display is used to diagnose causes of a Lockout condition. See Troubleshooting on page 60.
Figure 1. Protector Series Light Curtain System:
Emitter, Receiver, Interconnecting Cordsets
Figure 2. Protector Series Light Curtain cordset options
Test
Receiver
Emitter
Defined
Area
Status Indicators .......
visible on sensor face
RD Cordset
Euro QD Termination Pigtail;
requires mating QD cordset
for machine connection
RD to RD cordset
options are available
for compact sensor-to-
sensor connections
RD cordset with
flying leads
Cable pivots as it exits hous-
ing; bends to fit against
perpendicular surfaces
R 13 mm ...........
[0.5"] min. bend
Qty Description
2EZLSA-MBK-12 Center-Mount Bracket Kit (two brackets included for models with defined areas ≥ 980 mm)
1 Test Rod (STP-13 for 14 mm models; STP-19 for 23 mm models; or STP-20 for 40 mm models)
1 Literature packet with Diagnostic Label
Qty Description
1 Protector Series Light Curtain Receiver
1 Protector Series Light Curtain Emitter
2EZLSA-MBK-11 End-Cap Bracket Kit (four brackets)
SECTION 3 — PRODUCT OVERVIEW
Protector Series Light Curtains

Rockford Systems, LLC
8Call: 1-800-922-7533
Product Family Cascadable System Type Resolution - Defined Area Termination
Options:
SLL
Options:
Blank = No
C= Yes
Options:
E= Emitter only
R= Receiver only
P= Pair
(Emitter and
Receiver)
Options:
14 = 14 mm
23 = 23 mm
40 = 40 mm
- Options:
280 = 280 mm *
350 = 350 mm
420 = 420 mm
490 = 490 mm
560 = 560 mm
630 = 630 mm
700 = 700 mm
770 = 770 mm
840 = 840 mm
910 = 910 mm
980 = 980 mm
1050 = 1050 mm
1120 = 1120 mm
1190 = 1190 mm
1260 = 1260 mm
1330 = 1330 mm
1400 = 1400 mm
1470 = 1470 mm
1540 = 1540 mm
1610 = 1610 mm
1680 = 1680 mm
1750 = 1750 mm
1820 = 1820 mm
1960L = 1960 mm**
2100L = 2100 mm**
2380L = 2380 mm**
Options:
BLANK = no pigtail, RD
connection (for middle/end
units in cascade, includes
standard brackets
P5 = 300 mm pigtail, 5-Pin
M12 QD (individual Emitter
or Receiver models); includes
standard brackets
P55 = 300 mm pigtail, 5-Pin
M12 QD (paired models);
includes standard brackets
P8 = 300 mm pigtail, 8-Pin
M12 QD (individual Emitter
or Receiver models); includes
standard brackets
P88 = 300 mm pigtail, 8-Pin
M12 QD (paired models);
includes standard brackets
-S = no pigtail, RD connection
(individual Emitter or Receiver
only); brackets ordered
separately
EXAMPLE: SLLCP23-1470P88
* 280 mm defined area not available on cascade systems.
**1960 mm, 2100 mm, and 2380 mm defined area only available in 23 mm resolution non-cascade systems. Contact Banner Engineering for additional model availability.
Table 1: Protector Series Light Curtain Model Key
To determine the components required for a Protector Series Light Curtain system using the Model Key:
1. Determine if the application calls for a stand-alone (a single, non-cascade emitter and receiver pair) or if a cascade pair is to be used as a
stand-alone and/or with multiple pairs to be ordered are part of a cascaded system.
2. Choose an Emitter (E), a Receiver (R), or a Pair (P).
3. Choose resolution (14, 23, or 40 mm) and defined area.
4. Determine the Machine Interface connection style: 300 mm pigtail QD (5-pin or 8-pin) or a Removable Disconnect (RD).
5. Model number(s) can be verified in the models tables.
6. See Cordsets on page 75 for mating cordsets:
• Models with RD connection use either DELS-11..E, DELSE-81D, or DELSE-51D
• Models with P8 (P88) suffix use QDE-8..D, DEE2R-8..D, or CSB-M128..M1281
• Models with P5 (P55) suffix use QDE-5..D, DEE2R-5..D, or CSB-M125..M1251 (MQDEC-406SS is used in applications where pin 5 is open and ground is
via mounting brackets)
7. See Accessories on page 75 for additional cordsets (for cascade systems), interfacing solutions, and accessories.
8. For the "-S" models, see Mounting Dimensions on page 36 and Optional Mounting Brackets on page 82 for bracket options.
SECTION 3 — PRODUCT OVERVIEW
Protector Series Light Curtains

Rockford Systems, LLC
Call: 1-800-922-7533 9
ORDERING GUIDE
To order a Protector Series Light Curtain system, see Figure 3 below:
1. Determine if the application calls for a stand-alone (single, non-cascade emitter and receiver pair) or if a cascade pair is to be used as a
stand-alone and/or with multiple pairs to be ordered are part of a cascaded system.
2. Determine the connection style, which is typically dictated by the type of interfacing with the machine's safety-related control system (300
mm pigtail QD (5-pin or 8-pin) or a Removable Disconnect).
3. 3. Chose the model number(s) from the applicable model number table. Model numbers listed in the tables are RD connection style model
numbers. Add a P5 (or P55) or a P8 (or P88) at the end of the listed model number for a sensor with a 300 mm (1 ft) pigtail M12/Euro-style QD.
Figure 3. Ordering guide for stand-alone systems
Stand-Alone Cascade
Removable Disconnect (RD)5-Pin Pigtail QD
See tables for model numbers:
Resolution
See Table 2: 14 mm
See Table 3: 23 mm
See Table 4: 40 mm
Connection Style
Add the following suffix to
order a 5-pin pigtail QD:
P5 = Individual sensor
P55 = Pair
Interfacing Options*:
UM-FA-..A
XS/SC26-2..
SC10-2roe
MMD-TA-..B
General Accessories (including):
Mounting Brackets Stands Alignment Aids
Splitter Cordsets Lens Shield Mirrors
Light Curtain Indicators
See tables for model numbers:
Resolution
See Table 2: 14 mm
See Table 3: 23 mm
See Table 4: 40 mm
Connection Style
Add the following suffix to
order a 8-pin pigtail QD:
P8 = Individual sensor
P88 = Pair
Interfacing Options*:
IM-T-9A/-11A
SR-IM-9A/11A
Contactors
Alternate Options:
UM-FA-..A
XS/SC26-2..
SC10-2roe
MMD-TA-..B
Interfacing Options*:
IM-T-9A/-11A
SR-IM-9A/11A
Contactors
Alternate Options:
UM-FA-..A
XS/SC26-2..
SC10-2roe
MMD-TA-..B
See tables for model numbers:
Resolution
See Table 2: 14 mm
See Table 3: 23 mm
See Table 4: 40 mm
Connection Style
The model numbers listed
in these tables have RD
connections.
8-Pin Pigtail QD
Cordset Options:
5-pin cordset see:
Single-ended QDE-5..D
Double-ended DEE2R-5..D
Cordset Options:
8-pin cordset see:
Single-ended QDE-8..D
Double-ended DEE2R-8..D
Cordset Options:
8-pin cordset see:
Double-ended DELSE-8..D
See the next figure
for Cascade Ordering
System Guide
* 5-pin models must be interfaced with a self-checking safety module, safety controller, or safety PLC/PES that conforms
to the level of performance required by the risk assessment (such as Control Reliability and/or ISO13849-1 Categories 3 or 4 and PL d or e).
SECTION 3 — PRODUCT OVERVIEW
Protector Series Light Curtains

Rockford Systems, LLC
10 Call: 1-800-922-7533
Cordset models, interfacing option models and general accessory models can be found in Accessories on page 75.
Cordset models, interfacing option models and general accessory models can be found in Accessories on page 74
To order a cascade system, see Figure 4 below:
1. Determine the configuration of the first sensor pair (a stand-alone or the "Master" is connected to the machine control).
2. Determine the model from the applicable model number table. Model numbers listed in the tables are RD connection style model numbers.
Add a P5 (or P55) or a P8 (or P88) at the end of the listed model number for a sensor with a 300 mm (1 ft) pigtail M12/Euro-style QD.
3. Determine the remaining sensor pairs (slaves), which will be an RD connection style that uses a DELS 11xxE interconnection cordset.
Figure 4. Ordering guide for cascading systems
* 5-pin models must be interfaced with a self-checking safety module, safety controller, or safety PLC/PES that conforms
to the level of performance required by the risk assessment (such as Control Reliability and/or ISO13849-1 Categories 3 or 4 and PL d or e).
Sensor Pair #1 (Master/Machine Control)
Removable Disconnect (RD)5-Pin Pigtail QD
See tables for model numbers:
Resolution
See Table 5: 14 mm
See Table 6: 23 mm
See Table 7: 40 mm
Connection Style
Add the following suffix to
order a 5-pin pigtail QD:
P5 = Individual sensor
P55 = Pair
Interfacing Options*:
UM-FA-..A
XS/SC26-2..
SC10-2roe
MMD-TA-..B
General Accessories (including):
Mounting Brackets Stands Alignment Aids
Splitter Cordsets Lens Shield Mirrors
Light Curtain Indicators
See tables for model numbers:
Resolution
See Table 5: 14 mm
See Table 6: 23 mm
See Table 7: 40 mm
Connection Style
Add the following suffix to order
a 8-pin pigtail QD:
P8 = Individual sensor
P88 = Pair
Interfacing Options*:
IM-T-9A/-11A
SR-IM-9A/11A
Contactors
Alternate Options:
UM-FA-..A
XS/SC26-2..
SC10-2roe
MMD-TA-..B
Interfacing Options*:
IM-T-9A/-11A
SR-IM-9A/11A
Contactors
Alternate Options:
UM-FA-..A
XS/SC26-2..
SC10-2roe
MMD-TA-..B
See tables for model numbers:
Resolution
See Table 5: 14 mm
See Table 6: 23 mm
See Table 7: 40 mm
Connection Style
The model numbers listed
in these tables have RD
connections.
See tables for model number:
Resolution
See Table 5: 14 mm
See Table 6: 23 mm
See Table 7: 40 mm
Connection Style
The model numbers listed
in these tables have RD
connections.
If a stand-alone (standard)
pair is to be used as the end
sensor pair, see tables:
Resolution
See Table 2: 14 mm
See Table 3: 23 mm
See Table 4: 40 mm
Connection Style
The model numbers listed
in these tables have RD
connections.
8-Pin Pigtail QD
Cordset Options:
5-pin cordset see:
Single-ended QDE-5..D
Double-ended DEE2R-5..D
Cordset Options:
8-pin cordset see:
Single-ended QDE-8..D
Double-ended DEE2R-8..D
Cordset Options:
8-pin cordset see:
Double-ended DELSE-8..D
Cordset Options:
RD-to-RD cordset see:
DELS-11xxE
Cordsets for optional
features, see:
Light Curtain options: DELSEF-4..D
Sensor Pair
#2, #3, and
#4 (Slaves)
SECTION 3 — PRODUCT OVERVIEW
Protector Series Light Curtains

Rockford Systems, LLC
Call: 1-800-922-7533 11
MODELS TABLES
As listed in the following tables, the models include an RD connection (for middle/end units in cascade). Add one of these suffixes to the end of the
model number(s) listed in the tables below:
• P5: 300 mm (1 ft) PVC cable with a 5-pin M12 male quick-disconnect connector (individual Emitter or Receiver models)
• P55: 300 mm (1 ft) PVC cable with a 5-pin M12 male quick-disconnect connector (only Paired models)
• P8: 300 mm (1 ft) PVC cable with an 8-pin M12 male quick-disconnect connector (individual Emitter or Receiver models)
• P88: 300 mm (1 ft) PVC cable with an 8-pin M12 male quick-disconnect connector (only Paired models)
• -S: a unit with no mounting brackets (individual Emitter or Receiver models)
Table 2: Protector Series Light Curtain 14 mm Resolution Models (Standard/Stand-alone with RD connection)
Emitter Receiver Pair Defined Area Response Time,
Tr (ms)
Recovery Time, Type, OSSDs OFF to ON (ms)
Non-sync beam
blocked All beams blocked
SLLE14-280 SLLR14-280 SLLP14-280 280 mm 11.6 47 160
SLLE14-350 SLLR14-350 SLLP14-350 350 mm 13.3 55 186
SLLE14-420 SLLR14-420 SLLP14-420 420 mm 15.0 63 211
SLLE14-490 SLLR14-490 SLLP14-490 490 mm 16.7 69 237
SLLE14-560 SLLR14-560 SLLP14-560 560 mm 18.4 78 263
SLLE14-630 SLLR14-630 SLLP14-630 630 mm 20.1 86 288
SLLE14-700 SLLR14-700 SLLP14-700 700 mm 21.8 93 314
SLLE14-770 SLLR14-770 SLLP14-770 770 mm 23.5 101 339
SLLE14-840 SLLR14-840 SLLP14-840 480 mm 25.2 108 365
SLLE14-910 SLLR14-910 SLLP14-910 910 mm 26.9 116 391
SLLE14-980 SLLR14-980 SLLP14-980 980 mm 28.6 122 416
SLLE14-1050 SLLR14-1050 SLLP14-1050 1050 mm 30.3 130 442
SLLE14-1120 SLLR14-1120 SLLP14-1120 1120 mm 32.0 137 467
SLLE14-1190 SLLR14-1190 SLLP14-1190 1190 mm 33.7 145 493
SLLE14-1260 SLLR14-1260 SLLP14-1260 1260 mm 35.4 153 518
SLLE14-1330 SLLR14-1330 SLLP14-1330 1330 mm 37.1 160 544
SLLE14-1400 SLLR14-1400 SLLP14-1400 1400 mm 38.7 168 570
SLLE14-1470 SLLR14-1470 SLLP14-1470 1470 mm 40.4 175 595
SLLE14-1540 SLLR14-1540 SLLP14-1540 1540 mm 42.1 183 621
SLLE14-1610 SLLR14-1610 SLLP14-1610 1610 mm 43.8 191 646
SLLE14-1680 SLLR14-1680 SLLP14-1680 1680 mm 45.5 198 672
SLLE14-1750 SLLR14-1750 SLLP14-1750 1750 mm 47.2 206 697
SLLE14-1820 SLLR14-1820 SLLP14-1820 1820 mm 48.9 215 723
SECTION 3 — PRODUCT OVERVIEW
Protector Series Light Curtains

Rockford Systems, LLC
12 Call: 1-800-922-7533
Table 3: Protector Series Light Curtain 23 mm Resolution Models (Standard/Stand-alone with RD Connection)
Emitter Receiver Pair Defined Area Response Time,
Tr (ms)
Recovery Time, Type, OSSDs OFF to ON (ms)
Non-sync beam
blocked All beams blocked
SLLE23-280 SLLR23-280 SLLP23-280 280 mm 8.2 32 110
SLLE23-350 SLLR23-350 SLLP23-350 350 mm 9.1 36 124
SLLE23-420 SLLR23-420 SLLP23-420 420 mm 9.9 40 135
SLLE23-490 SLLR23-490 SLLP23-490 490 mm 10.8 44 148
SLLE23-560 SLLR23-560 SLLP23-560 560 mm 11.6 47 160
SLLE23-630 SLLR23-630 SLLP23-630 630 mm 12.5 51 175
SLLE23-700 SLLR23-700 SLLP23-700 700 mm 13.3 55 186
SLLE23-770 SLLR23-770 SLLP23-770 770 mm 14.2 59 199
SLLE23-840 SLLR23-840 SLLP23-840 840 mm 15.0 63 211
SLLE23-910 SLLR23-910 SLLP23-910 910 mm 15.9 67 225
SLLE23-980 SLLR23-980 SLLP23-980 980 mm 16.7 69 237
SLLE23-1050 SLLR23-1050 SLLP23-1050 1050 mm 17.5 74 249
SLLE23-1120 SLLR23-1120 SLLP23-1120 1120 mm 18.4 78 269
SLLE23-1190 SLLR23-1190 SLLP23-1190 1190 mm 19.2 82 274
SLLE23-1260 SLLR23-1260 SLLP23-1260 1260 mm 20.1 86 288
SLLE23-1330 SLLR23-1330 SLLP23-1330 1330 mm 20.9 89 300
SLLE23-1400 SLLR23-1400 SLLP23-1400 1400 mm 21.8 93 314
SLLE23-1470 SLLR23-1470 SLLP23-1470 1470 mm 22.6 97 325
SLLE23-1540 SLLR23-1540 SLLP23-1540 1540 mm 23.5 101 339
SLLE23-1610 SLLR23-1610 SLLP23-1610 1610 mm 24.3 104 350
SLLE23-1680 SLLR23-1680 SLLP23-1680 1680 mm 25.2 108 365
SLLE23-1750 SLLR23-1750 SLLP23-1750 1750 mm 26.0 112 376
SLLE23-1820 SLLR23-1820 SLLP23-1820 1820 mm 26.9 116 391
SLLE23-1960L SLLR23-1960L SLLP23-1960L 1960 mm 28.6 123 416
SLLE23-2100L SLLR23-2100L SLLP23-2100L 2100 mm 30.3 130 442
SLLE23-2380L SLLR23-2380L SLLP23-2380L 2380 mm 33.7 145 493
SECTION 3 — PRODUCT OVERVIEW
Protector Series Light Curtains

Rockford Systems, LLC
Call: 1-800-922-7533 13
SECTION 3 — PRODUCT OVERVIEW
Protector Series Light Curtains
Table 4: Protector Series Light Curtain 40 mm Resolution Models (Standard/Stand-alone with RD Connection)
Emitter Receiver Pair Defined Area Response Time,
Tr (ms)
Recovery Time, Type, OSSDs OFF to ON (ms)
Non-sync beam
blocked All beams blocked
SLLE40-280 SLLR40-280 SLLP40-280 280 mm 8.2 32 110
SLLE40-350 SLLR40-350 SLLP40-350 350 mm 8.2 32 110
SLLE40-420 SLLR40-420 SLLP40-420 420 mm 8.2 32 110
SLLE40-490 SLLR40-490 SLLP40-490 490 mm 8.2 32 110
SLLE40-560 SLLR40-560 SLLP40-560 560 mm 8.2 32 110
SLLE40-630 SLLR40-630 SLLP40-630 630 mm 8.6 34 117
SLLE40-700 SLLR40-700 SLLP40-700 700 mm 9.1 36 124
SLLE40-770 SLLR40-770 SLLP40-770 770 mm 9.5 38 129
SLLE40-840 SLLR40-840 SLLP40-840 840 mm 9.9 40 135
SLLE40-910 SLLR40-910 SLLP40-910 910 mm 10.3 42 142
SLLE40-980 SLLR40-980 SLLP40-980 980 mm 10.8 44 148
SLLE40-1050 SLLR40-1050 SLLP40-1050 1050 mm 11.2 45 155
SLLE40-1120 SLLR40-1120 SLLP40-1120 1120 mm 11.6 47 160
SLLE40-1190 SLLR40-1190 SLLP40-1190 1190 mm 12.0 49 168
SLLE40-1260 SLLR40-1260 SLLP40-1260 1260 mm 12.5 51 175
SLLE40-1330 SLLR40-1330 SLLP40-1330 1330 mm 12.9 53 179
SLLE40-1400 SLLR40-1400 SLLP40-1400 1400 mm 13.3 55 186
SLLE40-1470 SLLR40-1470 SLLP40-1470 1470 mm 13.7 57 193
SLLE40-1540 SLLR40-1540 SLLP40-1540 1540 mm 14.2 59 199
SLLE40-1610 SLLR40-1610 SLLP40-1610 1610 mm 14.6 61 206
SLLE40-1680 SLLR40-1680 SLLP40-1680 1680 mm 15.0 63 211
SLLE40-1750 SLLR40-1750 SLLP40-1750 1750 mm 15.4 65 216
SLLE40-1820 SLLR40-1820 SLLP40-1820 1820 mm 15.9 67 225

Rockford Systems, LLC
14 Call: 1-800-922-7533
Table 5: Protector Series Light Curtain 14 mm Resolution Models (Cascade with RD Connection)
Emitter Receiver Pair Defined Area Response Time,
Tr (ms)
Recovery Time, Type, OSSDs OFF to ON (ms)
Non-sync beam
blocked All beams blocked
SLLCE14-350 SLLCR14-350 SLLCP14-350 350 mm 13.3 55 186
SLLCE14-420 SLLCR14-420 SLLCR14-420 420 mm 15.0 63 211
SLLCE14-490 SLLCR14-490 SLLCR14-490 490 mm 16.7 69 237
SLLCE14-560 SLLCR14-560 SLLCR14-560 560 mm 18.4 78 263
SLLCE14-630 SLLCR14-630 SLLCR14-630 630 mm 20.1 86 288
SLLCE14-700 SLLCR14-700 SLLCR14-700 700 mm 21.8 93 314
SLLCE14-770 SLLCR14-770 SLLCR14-770 770 mm 23.5 101 339
SLLCE14-840 SLLCR14-840 SLLCR14-840 840 mm 25.2 108 365
SLLCE14-910 SLLCR14-910 SLLCR14-910 910 mm 26.9 116 391
SLLCE14-980 SLLCR14-980 SLLCR14-980 980 mm 28.6 122 416
SLLCE14-1050 SLLCR14-1050 SLLCR14-1050 1050 mm 30.3 130 442
SLLCE14-1120 SLLCR14-1120 SLLCR14-1120 1120 mm 32.0 137 467
SLLCE14-1190 SLLCR14-1190 SLLCR14-1190 1190 mm 33.7 145 493
SLLCE14-1260 SLLCR14-1260 SLLCR14-1260 1260 mm 35.4 153 518
SLLCE14-1330 SLLCR14-1330 SLLCR14-1330 1330 mm 37.1 160 544
SLLCE14-1400 SLLCR14-1400 SLLCR14-1400 1400 mm 38.7 168 570
SLLCE14-1470 SLLCR14-1470 SLLCR14-1470 1470 mm 40.4 175 595
SLLCE14-1540 SLLCR14-1540 SLLCR14-1540 1540 mm 42.1 183 621
SLLCE14-1610 SLLCR14-1610 SLLCR14-1610 1610 mm 43.8 191 646
SLLCE14-1680 SLLCR14-1680 SLLCR14-1680 1680 mm 45.5 198 672
SLLCE14-1750 SLLCR14-1750 SLLCR14-1750 1750 mm 47.2 206 297
SLLCE14-1820 SLLCR14-1820 SLLCR14-1820 1820 mm 48.9 215 723
SECTION 3 — PRODUCT OVERVIEW
Protector Series Light Curtains

Rockford Systems, LLC
Call: 1-800-922-7533 15
Table 6: Protector Series Light Curtain 23 mm Resolution Models (Cascade with RD Connection)
Emitter Receiver Pair Defined Area Response Time,
Tr (ms)
Recovery Time, Type, OSSDs OFF to ON (ms)
Non-sync beam
blocked All beams blocked
SLLCE23-350 SLLCR23-350 SLLCP23-350 350 mm 9.1 36 124
SLLCE23-420 SLLCR23-420 SLLCP23-420 420 mm 9.9 40 135
SLLCE23-490 SLLCR23-490 SLLCP23-490 490 mm 10.8 44 148
SLLCE23-560 SLLCR23-560 SLLCP23-560 560 mm 11.6 47 160
SLLCE23-630 SLLCR23-630 SLLCP23-630 630 mm 12.5 51 175
SLLCE23-700 SLLCR23-700 SLLCP23-700 700 mm 13.3 55 186
SLLCE23-770 SLLCR23-770 SLLCP23-770 770 mm 14.2 59 199
SLLCE23-840 SLLCR23-840 SLLCP23-840 840 mm 15.0 63 211
SLLCE23-910 SLLCR23-910 SLLCP23-910 910 mm 15.9 67 225
SLLCE23-980 SLLCR23-980 SLLCP23-980 980 mm 16.7 69 237
SLLCE23-1050 SLLCR23-1050 SLLCP23-1050 1050 mm 17.5 74 249
SLLCE23-1120 SLLCR23-1120 SLLCP23-1120 1120 mm 18.4 78 269
SLLCE23-1190 SLLCR23-1190 SLLCP23-1190 1190 mm 19.2 82 274
SLLCE23-1260 SLLCR23-1260 SLLCP23-1260 1260 mm 20.1 86 288
SLLCE23-1330 SLLCR23-1330 SLLCP23-1330 1330 mm 20.9 89 300
SLLCE23-1400 SLLCR23-1400 SLLCP23-1400 1400 mm 21.8 93 314
SLLCE23-1470 SLLCR23-1470 SLLCP23-1470 1470 mm 22.6 97 325
SLLCE23-1540 SLLCR23-1540 SLLCP23-1540 1540 mm 23.5 101 339
SLLCE23-1610 SLLCR23-1610 SLLCP23-1610 1610 mm 24.3 104 350
SLLCE23-1680 SLLCR23-1680 SLLCP23-1680 1680 mm 25.2 108 365
SLLCE23-1750 SLLCR23-1750 SLLCP23-1750 1750 mm 26.0 112 376
SLLCE23-1820 SLLCR23-1820 SLLCP23-1820 1820 mm 26.9 116 391
SECTION 3 — PRODUCT OVERVIEW
Protector Series Light Curtains

Rockford Systems, LLC
16 Call: 1-800-922-7533
Table 7: Protector Series Light Curtain 40 mm Resolution Models (Cascade with RD Connection)
Emitter Receiver Pair Defined Area Response Time,
Tr (ms)
Recovery Time, Type, OSSDs OFF to ON (ms)
Non-sync beam
blocked All beams blocked
SLLCE40-350 SLLCR40-350 SLLCP40-350 350 mm 8.2 32 110
SLLCE40-420 SLLCR40-420 SLLCP40-420 420 mm 8.2 32 110
SLLCE40-490 SLLCR40-490 SLLCP40-490 490 mm 8.2 32 110
SLLCE40-560 SLLCR40-560 SLLCP40-560 560 mm 8.2 32 110
SLLCE40-630 SLLCR40-630 SLLCP40-630 630 mm 8.6 34 117
SLLCE40-700 SLLCR40-700 SLLCP40-700 700 mm 9.1 36 124
SLLCE40-770 SLLCR40-770 SLLCP40-770 770 mm 9.5 38 129
SLLCE40-840 SLLCR40-840 SLLCP40-840 840 mm 9.9 40 135
SLLCE40-910 SLLCR40-910 SLLCP40-910 910 mm 10.3 42 142
SLLCE40-980 SLLCR40-980 SLLCP40-980 980 mm 10.8 44 148
SLLCE40-1050 SLLCR40-1050 SLLCP40-1050 1050 mm 11.2 45 155
SLLCE40-1120 SLLCR40-1120 SLLCP40-1120 1120 mm 11.6 47 160
SLLCE40-1190 SLLCR40-1190 SLLCP40-1190 1190 mm 12.0 49 168
SLLCE40-1260 SLLCR40-1260 SLLCP40-1260 1260 mm 12.5 51 175
SLLCE40-1330 SLLCR40-1330 SLLCP40-1330 1330 mm 12.9 53 179
SLLCE40-1400 SLLCR40-1400 SLLCP40-1400 1400 mm 13.3 55 186
SLLCE40-1470 SLLCR40-1470 SLLCP40-1470 1470 mm 13.7 57 193
SLLCE40-1540 SLLCR40-1540 SLLCP40-1540 1540 mm 14.2 59 199
SLLCE40-1610 SLLCR40-1610 SLLCP40-1610 1610 mm 14.6 61 206
SLLCE40-1680 SLLCR40-1680 SLLCP40-1680 1680 mm 15.0 63 211
SLLCE40-1750 SLLCR40-1750 SLLCP40-1750 1750 mm 15.4 65 216
SLLCE40-1820 SLLCR40-1820 SLLCP40-1820 1820 mm 15.9 67 225
OPERATING FEATURES
TRIP OUTPUT
The Rockford Systems Protector Series Light Curtain models described in this manual feature several functions (depending on model).
The System is configured for Trip Output which allows the System to enter Run mode automatically. Other measures must be taken to prevent a
pass-through hazard; see Reducing or Eliminating Pass-Through Hazards on page 26 and the warning below for more information.
The OSSD outputs turn ON after power is applied, and the receiver passes its internal self-test/synchronization and recognizes that all beams are
clear. The Trip Output also automatically resets after all beams are cleared.
WARNING:
• Use of automatic (trip) or manual (latch) start/restart
• Failure to follow these instructions could result in a serious injury or death.
• Applying power to the Banner Engineering device, clearing the defined area, or resetting a latch condition must not initiate dangerous
machine motion. Design the machine control circuitry so that one or more initiation devices must be engaged to start the machine (a
conscious act), in addition to the Banner Engineering device going into Run mode.
EXTERNAL DEVICE MONITORING (EDM)
The External Device Monitoring (EDM) feature allows the Protector Series Light Curtain to monitor the status of external devices, such as MPCEs. The
choices are 1-channel monitoring or no monitoring. EDM is used when the Protector Series Light Curtain OSSD outputs directly control the MPCEs
or other external devices.
This feature is only available when an 8-conductor interface is used.
SECTION 3 — PRODUCT OVERVIEW
Protector Series Light Curtains

Rockford Systems, LLC
Call: 1-800-922-7533 17
FAULT OUTPUT
The current sourcing (PNP) solid-state output (70 mA maximum) is used for control functions that are not safety related; a typical use is to signal a
lockout (fault) to a programmable logic controller (PLC). Available on both the receiver and emitter, the output provides a fault signal (lockout = On).
Interrupting (blocking) the sensing field is not considered a lockout, so the Fault Output does not change state.
This feature is available only when an 8-conductor interface is used.
SCAN CODE CONFIGURATION
WIRING OPTIONS
Use the scan code to allow operation of multiple pairs of emitters and receivers in close proximity without the effects of cross-talk. The emitter and
receiver may be configured to use one of two scan codes (1 or 2); a receiver recognizes light only from an emitter with the same scan code. Set the
scan code using the wiring on each sensor (see Scan Code Select on page 49). The scan code is configured at power-up and remains set until the
input is changed and power is cycled. Both the emitter and its corresponding receiver must have the same setting. Cascaded emitters and receivers
automatically alternate scan codes based on the scan code of the first (master) pair.
This feature is only available when an 8-conductor interface is used.
The Machine Interface connection has several options, including:
• A 300 mm (1 ft) pigtail cable with an 8-pin M12/Euro-style male quick disconnect (QD)
• A 300 mm (1 ft) pigtail cable with a 5-pin M12/Euro-style male quick disconnect (QD)
• The Removable Disconnect (RD) that can mate with either a double-ended RD cordset as an interconnect between cascaded sensors or an 8-wire flying
lead RD cordset
Each connection option is intended for maximum flexibility to solve unique application requirements such as directly connecting the Protector Series
Light Curtain to remotely located safety I/O blocks. For interfacing modules or remotely located safety I/O blocks where pin 5 of a 5-pin M12 QD
is not earth ground, a 4-pin cordset where pin 5 is not physically present or is not electrically connected can be used (such as MQDEC-406SS
double-ended cordset). In such situations, earth ground must be provided via the mounting brackets.
Additionally, a Protector Series Light Curtain emitter can be connected either to its own power supply or to the receiver cable, color-for-color. The
color-for-color wiring allows the emitter and receiver positions to be interchanged (swapped) without rewiring.
Figure 5. 300 mm Pigtail with M12/Euro-style QD Figure 6. RD Connection with 8-wire
Flying Lead Cordset
Figure 7. RD Connection with
Double-ended RD Cordset
CASCADING
Up to four sensor pairs (any length or resolution) can be combined into one system. The cascade system automatically configures at power up when
the terminator plug is installed (pre-installed from factory) or when a standard sensor pair or an interfacing cordset is used at the end of the series.
Double-ended DELS-11xE cordsets are required for connecting sensors in a cascade.
SECTION 3 — PRODUCT OVERVIEW
Protector Series Light Curtains

Rockford Systems, LLC
18 Call: 1-800-922-7533
PROTECTOR SERIES LIGHT CURTAIN INDICATION
Protector Series Light Curtain cascading models have the ability to connect and remotely locate an EZ-LIGHT or other indicator using a DELSEF-4xD
cordset. Solid-state current sourcing (PNP) outputs (24 V DC at 100 mA) allow for the connection of remote indicators or other devices for non-safety
status information that includes OSSDs ON or OSSDs OFF/Lockout (flashing).
Additionally, EZ-LIGHT model EZLSA-K30LGR (patent pending) is designed to mount directly to the end of a cascade receiver via the cascade RD
connector. The EZLSA-K30LGR provides a replaceable integral solution with a bright 360° red/green indication.
For the Protector Series Light Curtain standard (non-cascade) 8-pin pigtail QD models, a CSB-M128..M1281 splitter cable and optional DEE2R-8..D
double-ended cables can be used with specific models of EZ-LIGHTs at the machine interface connection. The EZ-LIGHT can be remotely mounted
on the machine frame or another convenient mounting surface and provides clear, 360°indication of the Protector Series Light Curtain receiver’s
OSSD output status.
For both standard and cascade solutions, refer to the EZ-LIGHTS listed in the Accessories on page 74.
INTERFACING AN E-STOP BUTTON OR INTERLOCKING SWITCH
REMOTE FIXED BLANKING
Protector Series Light Curtain cascading models can connect electrical (hard) contacts from external devices, such as emergency stop buttons and
interlocking switches, by using an RDLS-8..D cordset. The cascade input may be used to monitor emergency stop buttons, interlocked gates, or
guards and meets or exceeds the requirements for OSHA/ANSI control reliability and up to Category 4 PLe, per ISO 13849-1.
On cascade models, fixed blanking is available to, in effect, "disable" beams that would otherwise be continually blocked by a stationary object. One
or multiple areas within a Protector Series Light Curtain sensor pair may be "blanked out," with a minimum of one beam between two blanked areas.
The first sensing beam (CH1 synchronization beam) at the display end of sensor must remain clear (cannot be blanked); any other beam may be
blanked. All beams of a fixed blanked area must remain blocked during operation in order for the OSSDs to remain ON.
The Remote Fixed Blanking feature can be used on a Protector Series Light Curtain cascade receiver as a stand-alone system or in a cascaded
system. A DELSEF-81D cordset used with a EZA-RBK-1 Remote Blanking Key Switch and indicator provides a convenient means to program the
blanked area. (See Remote TEACH Fixed Blanking (Wiring) on page 73.)
The remote programming is effective on all receivers in the cascaded systems (for example, multiple areas can be blanked on different sensor pairs).
After programing, the EZA-RBK-1 Remote Blanking Key Switch can be removed (with power OFF) and replaced by the terminator plug, an EZ-LIGHT
(integral or remotely mounted), or an Emergency Stop/Interlocking switch via a RDLS-8..D cordset.
Figure 8. Protector Series Light Curtain
with M18 EZ-LIGHT
Figure 9. Protector Series Light Curtain with
EZLSA-K30LGR EZ-LIGHT
Figure 10. Protector Series Light Curtain
with TL50 EZ-LIGHT
SECTION 3 — PRODUCT OVERVIEW
Protector Series Light Curtains

Rockford Systems, LLC
Call: 1-800-922-7533 19
STATUS INDICATORS
Status indicators on both the emitter and receiver are visible on each sensor's front panel.
Emitter
Bi-color red/green Status indicator — shows whether power is applied, and whether the emitter is in RUN mode
(green) or Lockout condition (flashing red)
1-Digit Diagnostic Display — indicates configuration or specific error conditions.
Receiver
Bi-color red/green Status indicator — shows system status:
• outputs are ON or OFF (green ON or red OFF), or
• the System is in Lockout condition (flashing red)
Amber RUN mode indicator — shows system status:
• RUN mode (ON), or
• Lockout (OFF)
1-Digit Diagnostic Display — indicates conguration or specic error conditions,
or the total number of blocked beams.
Bi-color red/green Alignment indicators — show status of a group of beams (+/- 35 mm of indicator)
along the length of the exit window:
• aligned and clear (green ON), or
• blocked and/or misaligned (red ON),
• fixed blanked area (flashing green),
• lockout (all OFF), or
• Beam 1 (sync) is blocked (Alignment Indicator 1 is red and all others are OFF).
SECTION 3 — PRODUCT OVERVIEW
Protector Series Light Curtains
Figure 11. Status Indicators
– Emitter
Figure 12. Status Indicators
– Receiver
Status Indicator
Diagnostic Display
Run Mode Indicator
Status Indicator
Diagnostic Display
Alignment Indicator(s)

Rockford Systems, LLC
20 Call: 1-800-922-7533
SPECIFICATIONS
Emitter
Receiver*
Cascade** Standard
Length Max*** Typical Max*** Typical Typical
280 30 25 112 - 69
350 30 25 115 100 72
420 30 25 117 102 74
490 30 25 11i 104 76
560 30 25 122 106 78
630 30 25 124 108 80
700 31 25 127 110 82
770 31 26 129 112 84
840 31 26 132 114 86
910 31 26 134 117 89
980 31 26 137 119 91
1050 31 26 139 121 93
1120 31 26 141 123 95
1190 31 26 144 125 97
1260 32 26 146 127 99
1330 32 26 149 129 101
1400 32 26 151 131 103
1470 32 27 154 134 106
1540 32 27 156 136 108
1610 32 27 159 138 110
1680 32 27 161 140 112
1750 32 27 163 142 114
1820 32 27 166 144 116
1960 33 27 171 N/A 120
2100 33 27 176 N/A 125
2380 33 28 185 N/A 133
GENERAL SPECIFICATIONS
Supply Current (mA)
*Supply current exclusive of OSSD1 and OSSD2 loads (up to additional 0.5 A each) and
Fault Output load (up to 0.070 A).
**Adding an indicator (EZ-LIGHT) to the CSSI will increase the receiver current draw.
Consult the indicator specications for the value of the additional current.
***Maximum current occurs at a supply voltage of 20 V DC.
Operating Conditions
–20 °C to +55 °C (–4 °F to +131°F)
95% maximum relative humidity (non-condensing)
Enclosure Ratings
280 mm to 1820 mm length models: IP65/IP67 1890 mm
to 2380 mm length models: IP65
Supply Voltage at the Device
24 V DC ±15% (use a SELV-rated power supply according to EN IEC 60950).
The external voltage supply must be capable of buffering brief mains
interruptions of 20 ms, as specified in IEC/EN 60204-1.
Residual Ripple
±10% maximum
Short Circuit Protection
All inputs and outputs are protected from short circuits to +24 V DC or
DC common
Electrical Safety Class
III (per IEC 61140: 1997)
Operating Range
280 mm to 1820 mm length models: 0.1 m to 12 m (4 in to 39 ft) 1890
mm to 2380 mm length models: 0.1 m to 10 m (4 in to 32.8 ft) The range
decreases with the use of mirrors and/or lens shields:
• Lens shields — approx 10% less range per shield
• Glass-surface mirrors — approx 8% less range per mirror
See the specific mirror datasheet for more information. Contact Rockford
Systems for more information.
Resolution
14 mm, 23 mm, or 40 mm, depending on model
Effective Aperture Angle (EAA)
Meets Type 4 requirements per IEC 61496-2
Enclosure
Extruded aluminum housing with yellow polyester powder finish standard
and well-sealed, rugged die-cast zinc end caps, acrylic lens cover
Mounting Hardware
Emitter and receiver each are supplied with a pair of end-mounting
brackets. Models longer than 910 mm also include an additional center-
mount bracket for support. Mounting brackets are 8-gauge cold-rolled
steel, black zinc finish.
For models ending in -S, all mounting hardware is ordered separately. The
1890 mm to 2380 mm models require at least 2 center brackets.
Cables and Connections
See Cordsets on page 75
Safety Rating
Type 4 per IEC 61496-1, -2
Category 4 PL e per EN ISO13849-1
SIL3 per IEC 61508; SIL CL3 per IEC 62061 PFHd:
Non-Cascade 1.30 × 10-10
1- Pair Cascade 3.92 × 10-10
2- Pair Cascade 7.83 × 10-10
3- Pair Cascade 1.18 × 10-9
4- Pair Cascade 1.57 × 10-9
Proof Test Interval: 20 years
Vibration and Mechanical Shock
Components have passed vibration and shock tests according to IEC
61496-1 (Class 3M4). This includes vibration (30 cycles) of 5 to 150
Hz at 3.5 mm (0.14 in) amplitude and shock of 15 g for 6 milliseconds
(600 cycles).
Certifications
SECTION 4 — SPECIFICATIONS
Protector Series Light Curtains