4Eastwood Technical Assistance: 800.343.9353 >> techelp@eastwood.com
SET-UP
• Using a good quality Teflon sealing tape (not included), thread the 1/4” MNPT, Male quick
disconnect inlet fitting into the air inlet.
INJURY HAZARD!
To avoid injury, always disconnect air supply to Die Grinder before installing
or replacing accessories.
INJURY HAZARD!
To avoid injury, only use accessories rated for High-RPM,
(20,000 or greater) use.
TO INSTALL OR SWITCH ACCESSORIES (NOT INCLUDED):
• With air supply disconnected,
Slide the smaller 11mm Shaft
Wrench over the flats of the
shaft and the larger 17mm Collet
Wrench over the flats of the Collet
Retainer (FIG 1). Loosen the
threaded-on Collet Retainer to re-
lease the Collet grip on accessory
then and pull out the accessory.
Replace accessory with one of
the same size shank by sliding
the shank into the Collet then
retighten securely.
TO SWITCH TO A COLLET OF ANOTHER SIZE:
• With air supply disconnected,
Slide the smaller 11mm Shaft
Wrench over the flats of the
shaft and the larger 17mm Collet
Wrench over the flats of the Collet
Retainer. Loosen then remove the
threaded-on Collet Retainer and
place it aside for re-installation
(FIG 2).
• Withdraw the accessory (if
installed) and the Collet (FIG 2).
• Install Collet into bore of Shaft.
• Place accessory (not included) into Collet.
• Replace Collet Retainer and tighten securely with included Wrenches.
1/8”
Collet
FIG. 1
FIG. 2
1/4” Collet
Collet
Retainer
11mm Wrench
17mm Wrench