Rocstor SolidRack R3100 User manual

®
SolidRack R3100 Rack 42U Enclosure With Side Panels
User Manual
Y10E007-B1

Rocstor Legal Disclaimer
Introduction
Dimensions Specication
Important Safety Information
Safety Instructions
Component Identication
Hardware and Accessories
Cabinet Installation
Level the Rack Cabinet
Join the Cabinets
Ground the Cabinet
Install & Remove Side Panels
Five-Year Factory Warranty
1
2
2
3
4
5
6
7
8
9
10
11
12
Page
Table of Contents

The information presented in this manual is not warranted by Rocstor to be totally authoritative, error free,
or complete. This publication is not meant to be a substitute for a detailed operational and a site-specic
development plan for the use of the product. Therefore, Rocstor assumes no liability for damages, violations
of codes, improper installation, system failures, or any other problems that could arise based on the use of
this Manual.
THE WARRANTY AND REMEDIES SET FORTH ABOVE ARE LIMITED IN TIME TO THE DURATION OF THE
WARRANTY AS STATED HEREIN AND IS EXCLUSIVE IN LIEU OF ALL OTHER WARRANTIES, LEGAL THEORIES,
REMEDIES AND CONDITIONS, WHETHER ORAL OR WRITTEN, EXPRESS OR IMPLIED. IN NO EVENT SHALL
ROCSTOR, OR ANY PARENT, AFFILIATE OR SUBSIDIARY COMPANY OF ROCSTOR OR THEIR RESPECTIVE
OFFICERS, DIRECTORS, OR EMPLOYEES BE LIABLE FOR ANY DIRECT, INDIRECT, CONSEQUENTIAL, PUNITIVE,
SPECIAL, OR INCIDENTAL DAMAGES, INCLUDING, WITHOUT LIMITATION, DAMAGES FOR LOSS OF BUSINESS,
CONTRACTS, REVENUE, LOST PROFITS, DATA, INFORMATION, GOODWILL OR BUSINESS INTERRUPTION
RESULTING FROM OR ARISING OUT OF THE USE OF THE PRODUCT OR FAILURE TO FOLLOW INSTRUCTIONS
IN THE MANUAL.
FURTHERMORE, ROCSTOR SPECIFICALLY DISCLAIMS ANY AND ALL IMPLIED WARRANTIES INCLUDING,
WITHOUT LIMITATION, WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. IF
ROCSTOR CANNOT LAWFULLY DISCLAIM SUCH IMPLIED WARRANTIES, THOSE IMPLIED WARRANTIES WILL BE
LIMITED IN DURATION TO THE DURATION SET FORTH ABOVE.
FURTHER STILL, ROCSTOR RESERVES THE RIGHT TO MAKE CHANGES OR UPDATES WITH RESPECT TO THE
CONTENT OF THE PUBLICATION OR THE FORMAT THEREOF AT ANY TIME AFTER PURCHASE WITHOUT
NOTICE.
Some states and provinces do not allow the exclusion or limitation of incidental or consequential damages
or exclusions or limitations on the duration of implied warranties or conditions, so the above limitations or
exclusions may not apply to you. This warranty gives you specic legal rights and you may also have other
rights that vary by state or province.
Copyright, intellectual, and all other proprietary rights in the content of the manual (including but not
limited to software, audio, video, text, and photographs) rests with Rocstor or its licensor. All rights in the
content are the property of Rocstor and are not granted, licensed, assigned or otherwise passed to the
purchaser’ of the product or to persons having access to the information in the manual
Page 1
Rocstor Legal Disclaimer

Introduction
Dimensions Specication
The Rocstor SolidRack R3100 cabinet is a reliable and high-quality cabinet for storing of industry-standard (EIA/ECA-310), 19 in.
(483 mm) rack-mount hardware and equipment. Users can use this storage rack for data storage, servers, telecommunication
equipment such as voice, data, networking and power protection equipment.
This manual provides notes for the general installation and conguration of SolidRack R3100 Cabinets.
Width(mm)
42U 600 1070
Capacity(U) Depth(mm)
Available Rack Dimensions
Depth
(1070mm) - (42.13in)
Hight
(1992mm) - (78.43in)
Width
(600mm) - (23.62in)
Page 2

Important Safety Information
Please review and read the instructions very carefully in order to understand the specication of the equipment. This is
essential information before installing, operating, service or maintaining your equipment. These messages or alerts may appear
throughout this publication and manual for your purchased equipment. The messages are designed to warn you of possible
hazards or to bring to your attention the information that would assist and claries steps and procedures.
DANGER
WARNING
CAUTION
CAUTION
NOTICE
DANGER This symbol represents an imminently hazardous situation which, if not avoided,
will result in death or serious injury. Please follow instructions carefully.
WARNING This symbol represents a potentially hazardous situation which, if not avoided, can
result in death or serious injury. Please follow instructions carefully.
CAUTION This symbol indicates a potentially hazardous situation which, if not avoided, can
result in minor or moderate injury.
CAUTION, This symbol is used without the safety alert symbol, indicates a potentially
hazardous situation which, if not avoided, can result in equipment damage. Please follow
instructions carefully. Please follow instructions carefully.
NOTICE This symbol provides informations and practices not related to physical injury
including certain environmental hazards, potential damage or loss of data. Please follow
instructions carefully.
This is a safety alert symbol. It is used to alert you to potential personal
injury hazards. Please follow the instructions very carefully and obey all
safety messages that follow this symbol to avoid possible injury or death.
This symbol and label provides Danger or Warning safety which indicates
an electrical hazard exists. If instructions are not fully followed, it may
result in personal injury.
Page 3

Safety Instructions
Please follow the essential and important instructions in this manual. The information provides you useful instructions for
installation and customization of the rack or equipment.
• The content of this packaging is easily tipped. Please be extra careful and use extreme caution
when moving or unpacking this cabinet.
• Two people are preferred and are required to move and unpack the cabinet.
• Before moving the cabinet on its casters, load in the means of servers, storage, or other
equipment 159 kg (350 lb) of equipment into rack and place the equipment at the bottom of the
cabinet for additional stability.
• Make sure the leveling feet are up when moving or pushing the cabinet. DO NOT push the
cabinet from its sides.
TIP/ HEAVY EQUIPMENT HAZARD
Not following these instructions carefully, it can result in death, serious injury, or
equipment damage
WARNING
Labels
Look for additional safety information axed to the cabinet.
Page 4

Component Identication
Cabinet
Top cover
Front door
Door frame
Side Door
Cable management rack
Right rear
Left bracket
Left rear
1
2
2
3
3
4
Beam Welded Body
6
7
7
8
8
9
9
5
M12 leveling feet
Right bracket
Cabinet reinforcement plate
2 inch casters
10
10
11
11
12
12
13
13
1
4
5
6
Page 5

Hardware and Accessories
To ensure proper and secure installation, cage nuts need to be installed horizontally
as shown below. Installing cage nuts in the incorrect orientation can cause injury or
equipment damage.
M6 Cage Nut (50)M6 Phillips-Head Screw (50) Cup Washer (50)
Allen Wrench Key (2)Retention Tab*
Page 6

Cabinet Installation
Move the Cabinet
• Be extremely cautious when moving or unpacking this rack/cabinet.
• When moving or unpacking this cabinet. Two people are preferred and are required to move and unpack
the cabinet.
• Before moving the cabinet on its casters, place a load 159 kg (350 lb) of equipment such as servers or
storage equipment into rack at the bottom of the cabinet for additional stability.
• Make sure the leveling feet are up when moving or pushing the cabinet. DO NOT push the cabinet from its
sides.
TIP/ HEAVY EQUIPMENT HAZARD
WARNING
Not following these instructions carefully, it can result in death, serious injury, or equipment
damages.
Page 7

The leveling feet at the corners of the equipment provide a stable base if the door is uneven, but they cannot
compensate for a badly sloped surface. Ensure the cabinet is in its intended location. Remove the front and
rear doors.
NOTE: Before removing the front door, unplug the ground wires and any other wire connections that may
interfere with the removal of the doors.
NOTE:
• Use an 18 mm open-end wrench to lower each leveler A until it reaches the
oor. (There are 4 levelers, 2 at the front and 2 at the rear.) Make sure each
leveler contacts the oor solidly.
• Adjust each foot and, using a level, adjust the feet until the cabinet is level
and plumb. Do not install the doors until after the cabinet is joined to others
in the row.
Level the Rack Cabinet
Note: Lower a leveler by turning it clockwise; raise a leveler by turning it
counter-clockwise.
Page 8

Join the Cabinets
Join cabinets with the baying brackets option kit included with the SolidRack 42U. Which will provide
alignment and added stability. SolidRack AR3100 cabinets may be joined with or without the side panels
installed.
TIP HAZARD
If multiple racks are used, joining cabinets provides limited stability to the
cabinets. Secure the cabinet to the oor before installing equipment.
Please follow these instructions very carefully. Failure to follow these
instructions can result in death, serious injury, or equipment damage.
WARNING
Enclosures within the same row can be connected together by using the included brackets.
Side panels can be removed for access between enclosures but is not necessary. There are two
connecting brackets on the front and two on the rear of each enclosure.
1. Align the enclosures that will be connected together.
2. Remove the enclosure doors.
NOTE: See the Remove Front and Rear Doors section for instructions.
3. Remove a connecting bracket, shown below. Align the connecting bracket between the
enclosures such that each end can screw into the other enclosure. Repeat this step for all
connecting brackets. Each pair of enclosures should be connected together by two front and
two rear brackets.
Page 9

Ground the Cabinet
HAZARD OF ELECTRIC SHOCK
Connection of the cabinet to building Common Bonding Network (CBN) is required.
Failure to follow these instructions will result in death or serious injury.
DANGER
Please note that each cabinet should be bonded directly to a common ground using one of the designated
grounding points (M6 threaded inserts) at the bottom of the cabinet.
• All enclosure doors have a pre-installed ground wire connected to the enclosure frame.
• To connect the enclosure to facility's ground, please use the reserved grounding holes
on the base of the front or rear door frame.
• Install an 8 AWG wire with the included M6 screw, and connect the other side of the
wire to the facility's grounding point.
Page 10

Install & Remove Side Panels
Adding or Removing Side Panels
Removing Side Panel
1- Open the latch by sliding it downward.
2- Tilt the top of the panel away from the enclosure.
3 Lift the panel away from the brace that supports it.
To Reinstall Side Panel, Reverse Steps 1-3
Door and Side Panel Locks
The front door, rear door and side panel locks are keyed-alike. Use the included keys to operate the locks.
1
2 3
Page 11

Five-Year Factory Warranty
Rocstor provides a Limited Factory Warranty which applies to products you have purchased for commercial
or industrial use in the ordinary course of your business.
Terms of warranty
Rocstor warrants its SolidRack product series to be free from defects in materials and workmanship for a
period of ve years from the date of purchase. Rocstor’s obligation under this warranty coverage is limited
to repairing or replacing, at its sole discretion, any such defective products. This warranty does not apply to
equipment that has been damaged by accident, negligence, or misapplication or has been altered or
modied in any way. In the event Rocstor repairs or provide a replacement of a defective product or part,
the warranty does not extend the original warranty period. Rocstor reserves the right to repair or replace
any parts under warranty as new or factory re manufactured.
Non-transferable warranty
This warranty extends only to the original purchaser who must have properly registered the product.
The product may be registered at the Rocstor Web site, https://rocstor.com/customer-support/warranty
registration.
Exclusions
If Rocstor tests or examines the alleged defect in the product and nds that the damages or defects do not
exist or were caused by a third party or an end user’s misuse, improper installation or testing, or negligence,
then Rocstor shall not be liable under the warranty. Furthermore, unauthorized attempts to repair or modify
the product by wrong or inadequate electrical connection or voltage, inadequate or inappropriate site
operation conditions, repair, installation corrosive area or atmosphere, a change in location or operating
conditions or use, repair by non-Rocstor designated personnel, exposure to the elements, re, Acts of God,
theft, or equipment installation not recommended or contrary to Rocstor’s specications or
recommendations. Warranties will be void and Rocstor will not be liable if the product serial number is
tampered with, altered, removed, defaced or any other cause beyond the range of intended use.
Page 12

Table of contents
Other Rocstor Enclosure manuals
Popular Enclosure manuals by other brands

GAMDIAS
GAMDIAS Talos P1 Quick installation guide

Pulsar
Pulsar AWO 200PU Assembly instructions

Audio international
Audio international EN-650W-01-x installation manual

Amphenol
Amphenol Charles CUBE-PM628155N4 General description and installation

Kontron
Kontron MicroTCA OM6040D user guide

Hammond Manufacturing
Hammond Manufacturing H1 quick start guide