ROE MC-7H User manual

- 1 -
User Manual
MC-7H with Touring frame
(BlackLED / No transparency)

- 2 -
Control System
Contents
Safety Information
03
Specification 06
Connection 07
Physical Connection 14
Accessories
Base bar Assembly
08
09
16
18Package
17
Service and Maintance

The following symbols are used to identify important safety information on the product and in this manual:
WARNING!
Read the safety precautions in this section before
installing, powering, operating or servicing this
product.
WARNING!
Safety hazard.
Risk of severe
injury or death.
WARNING!
Refer to
manual before
installing,
powering or
servicing.
WARNING!
Hazardous
voltage. Risk of
lethal or severe
electric shock.
WARNING!
Hot surface. Do
not touch.
WARNING!
Fire hazard.
WARNING!
Emission
hazardous to
eyesight.
This product is for professional use only. It is not for household use.
This product presents risks of severe injury or death due to fire hazards, electric shock and falls.
Read this manual before installing, powering or servicing this product, follow the safety precau-
tions listed below and observe all warnings in this manual and printed on the product.
If you have questions about how to operate the panel safely, please contact your ROE supplier.
PROTECTION FROM ELECTRIC SHOCK
Connect the product to AC mains power within the range 100-240V nominal at 50 or 60 Hz only .
Disconnect the product from power when not in use.
Always ground (earth) the product electrically.
Before using the product, check that all power distribution equipment and cables are in perfect
condition and rated for the current requirements of all connected devices.
Do not use the product if the power cable or a power plug is in any way damaged, defective or
showing signs of overheating.
Do not attempt to open any cover.
Refer any service operation not described in this manual to a qualified technician.
- 3 -
01 Safety Information:

PROTECTION FROM FIRE
Do not stick filters, masks or other materials directly onto LED modules.
Do not modify the product in any way not described in this manual.
Install only genuine ROE parts in or on the product unless an alternative is described in this manual.
PROTECTION FROM INJURY
Create an installation by installing panels at the top and working downwards. Disassemble an
installation by removing panels at the bottom and working upwards.
Check that all external covers and rigging hardware are securely fastened.
Block access below the work area and work from a stable platform whenever installing, servicing
or moving the product.
- 4 -
Do not operate the product full load if the ambient temperature of power units (Ta) exceeds 45°C
(113° F) or less than -20℃(-4° F).
165+5 170+5
1480
2000
Pout/W
Vin/Vac

In order to protect against risk of electric shock, the installation should be prop
erly grounded. Defeating the purpose of the grounding type plug will expose you
to the risk of electric shock.
of Leakage current. In order to avoid risk of electric shock due to high leakage
Important warnings
Maximum and minimum ambient temperature:
The maximum ambient temperature for the LED wall is 45 °C; the minimum tem-
perature is -20 °C.
High leakage current:
The combination of power boxes in an installation results in increased levels
Data cables:
The data cables provided with this system have special properties for safety.
They are not user serviceable. If the data cables are damaged, replace them
only with new ones. Never try to repair a data cable. Per requirements of the
National Electrical Code®in the USA, the length of a data cable must not
exceed 100 m (332 feet). Avoid exposure of data cables to accidental contact
with lightning or power conductors.
MC-7H Panels cannot be hot swapped:
Always disconnect the power cord from the control box before connecting or
-
-
current, proper grounding of the installation is required.
Power system
Mains cords:
The power cords delivered with this system have special properties for safety.
They are not user Serviceable. If the power cords are damaged, replace them
only with new ones. Never try to repair a power cord.
- 5 -
disconnecting the cable string or one of MC-7H Panels.
This equipment MUST be earthed:
--
-

- 6 -
MC-7H Dimensions:MC-7H Specification:
Specification:
02
600.0mm
7.5mm
7.5mm
600.0mm 95.0mm
95.0mm
A
A
B
B
H
IJ
E
E
CD F
G K
A. Horizontal Lock
B. Lock Pin
C. Testing Button
D. Indicator Light
E. Horizontal Downel
F. Vertical Connector
G. Position Pin
H. Breather Value
I. Handle
J. Leather Sheath
K. Pothook
Backside diagram
Note:
MC-H Panels is lightweight and virtually transparent outdoor LED display.They offer wide viewing angles
with excellent image integrity and color uniformity, owning the common characteristics of lightweight and
firm structure. With the amazing flexibility and high density, both of them can be able to multi-angle folded,
satisfy your solution for applications with long viewing distances.
IP(Front/Reverse)
LED Type
Transparency
Brightness(Nit or CD/m²)
3in1 SMD
7.5mm
0%
600.0×600.0×95.0
0.36m²
80×80
17778
160°
-10°/0°/+10°
13.50kg/29.76lbs
1/5
1800Hz
360W
ETL/TUV/CE
Scan
Processing 2560×1024
Color Depth
Certificates
-20°C to 45°CWorking Temperature
Pixel Pitch
Module Size(mm) W×H×D
Module Area
Pixels/Module
Pixels/m²
Viewing Horizontal/Vertical
Weight/Module(with frame)
8.0kg/17.64lbs
Weight/Module
Curve Angle
Max.hanging
Max.stacking
16bit
IP65
Refresh Rate
Max Powe/Module
Black 3535,4000
20 panels
8 panels

- 7 -
Connection:
03
MC-7H Built in Power Supply
Hanging system
Stacking system
MC-7H MC-7H MC-7H MC-7H
MC-7H MC-7H MC-7H MC-7H
MC-7H MC-7H MC-7H MC-7H
MC-7H MC-7H MC-7H MC-7H
MC-7H MC-7H MC-7H MC-7H
MC-7H MC-7H MC-7H MC-7H
MC-7H MC-7H MC-7H MC-7H
MC-7H MC-7H MC-7H MC-7H
7
6
Evision
Evision

- 8 -
Accessories
04
Name
Part No.
Dimension
Weight
Material
Base bar
207002S(0012/0013)
L(562/1162)xW89xD202mm
6.40kg
Cold Rolled Steel
:
:
:
:
:
Name
Part No.
Dimension
Weight
Material
Base bar
207002S(0012/0013)
L(562/1162)xW89xD159mm
6.40kg
Cold Rolled Steel
:
:
:
:
:
Name
Part No.
Dimension
Weight
Max Current
Max Capacity
Power Cable
208001S0611
30m
4.60kg
16A
8 tiles of MC-7H(AC 220V)
4 tiles of MC-7H(AC 110V)
:
:
:
:
:
:
Name
Part No.
Dimension
Weight
Max Length
CAT-5
208004S0194
30m
1.40kg
100m
:
:
:
:
:
Name
Part No.
Dimension
Weight
Evision
201000S0009
L480 x W240 x H45mm
2.30kg
:
:
:
:
Name
Part No.
Dimension
Max Capacity
T Dolly
206002S0049
L1295xW790xH1500mm
24 tiles of MC-H
:
:
:
:
Name
Part No.
Dimension
Max Capacity
Flightcase
309003-00036
L1334xW600xH885mm
8 tiles of MC-H
:
:
:
:
Name
Part No.
Dimension
Weight
CAT-5
208002S0225
0.93m
0.10kg
:
:
:
:
Name
Part No.
CAT-5
203000S0015
:
:
Dimension
Weight
L56xW32xH26mm
0.10kg
:
:

- 9 -
Base Bar Assembly:
05
A
B
D
E
F
C
Hanging System
89mm 605mm
175mm
Base Bar
Hanging Installation
Figure 1
Figure 2
A: Horizontal connector
E: Lock of base truss
F: Ring(For hanging installaon)
B: Level adjusng screw
C: Locaon Pin(For stacking installaon)
D: Vercal connecon lock
Note:
Ring and Locaon pin can be removed and exchange with each other.
Before hanging installaon, please make sure the ring is on the top of the bar.
Adjust the level adjustment and make sure the boom of the base bar is flat.
Open the vercal connecon lock.

- 10 -
1. Bars connecon with each other.
Adjust the direcon of the horizontal connectors and make sure one red and one blue
on the top side.
0 degree
2. Install the base bar with panels
Install the base bar on the panels with touring frame. And lock the vercal connecon
lock before raising the screen.

- 11 -
Stacking System
Stacking Installation
Rear support truss Rear bridge
Base bar Base truss
Before hanging installaon, please make sure the locaon pin is on the top of the bar.
Adjust the level adjusng screw and make the base bar keep horizontal on the ground
Adjust the direcon of the horizontal connectors and make sure one red and one blue
on the top side.
1. Base bars connecon with each other.
0 degree

- 12 -
2. Base bar connecon with base truss.(Two kinds of different installaon.)
Adjust the knob and make sure
the base truss horizontal.
Lock of base truss
Case 1:
Case 1:
Adjust the knob and make sure
the base truss horizontal.
Lock of base truss
3. Rear support truss and rear bridge installaon
Case 2:
Case 2:

- 13 -
Case 1
Case 2
Touring frame
Rear support truss
Rear bridge
Base bar
Base truss
Stacking system
4. Panel installaon

- 14 -
Physical Connection:
06
Straight installation
Horizontal connector operation
1. Press the red buon to loosen the handle.(pic1)
2. Pull the handle to turn the connecng bar.(pic3)
3. Connect two panels and align them.(pic5)
4. Keep the connecng buon on “0 degree”.(pic5)
5. Push handle back for locking.(pic7)
Picture 1 Picture 2 Picture 3 Picture 4
Picture 5 Picture 6 Picture 7 Finish
MC-7H panles
Curve Installation(stacking and hanging)
Our touring system can make 10 degrees curve installation horizontally.
Befor installaon, please adjust the horizontal connectors on base bars and panles’ touring frames.
Base bar

- 15 -
0 degree
+10 degree
stacking installaon
hanging installaon
stacking installaon
hanging installaon
-10 degree
stacking installaon
hanging installaon

01234
56789
Black
DVI
HDMI
OK
Esc Fn
Menu
- 16 -
Software:
Please read software manual firstly,(download link as below):
Http://www.roevisual.com/how-to-make-led-display
The control system of MC-7H consist of receiving card and sending card.
Receiving card is integrated with LED panels.
Control System:
07
Evision (201000S0009)
Working
v o
ltage
Power
100-240V AC
<20W
Working temperature -20°C to 45°C
Input port DVI
Output ports number 4 ports
Communication port USB/RJ45
2560
×1024
Max resolution
2560
×
1024
1024
Data transmission port 1000M Ethernet
Material AL6061
Dimension
L480×W240×H45mm
Weight 2.30kg
1. Power switch
2. Number keys
3. LCD screen
4. Function keys
5. Knob
6. DVI port
7. HDMI port
8. USB port
9. RJ45 data port
10. Power port
Front
Behind
INPUT 100-240V AC 50/60HZ
PORT 4PORT 3PORT 2PORT 1USB2USB1HDMIDVI
1
678910
2 3 4 5
640 640 640 640

Note: When the failure occurs,the color of indicator light will show the prority in the following order.
1. Error receiving card.
2. The power is above 36V or below 24V
3. Excessive panel temperature.
4. Wrong signal.
5. No signal.
Light status on the backside of MC-7H Series
OK Signal input from top
to bottom
Green (2Hz/second) Normal
Normal
The receiving card doesn’t work.
The supply voltage is above 36V or below 24V.
The temperature of panel exceeds 50℃.
1.The bad connection between the receiving cards.
2.The pins on the receiving card is curved or broken.
Disconnected the UTP cable between the receiving
card and the panel.
Blue (2Hz/second)
Red (Always)
Red (2Hz/second)
Green (Always)
Blue (Always)
Yellow (2Hz/second)
Signal input from
bottom to top
Error receiving card
OK
OK
Wrong signal
No signal
OK
OK
OK
OK
OK
Above 36V or below 24V
Power Data Color of Light Factors
Service and Maintance:
08
- 17 -
Picture 1 Picture 2 Picture 3
Picture 4 Picture 5 Picture 6
Maintance:
1. Remove the Power Cable.
2. Remove the Data Cable.
3. Pull out the Lock Pin.
4. Hold the handle to push the panle forward.
Maintenance on overall installaon, just replace the bad panels.

Package
09
- 18 -
8pcs LED panels per Flightcase
24pcs LED panels per T Dolly
Pictures
Flightcase T Dolly

- 19 -
The end
ROE Visual Co., Ltd
No.1-3 Floor, Bldg 7,Zhong Yuntai Technology Industrial Park,
Songbai Road, Shiyan Street, Baoan,Shenzhen,China
Tel:+86-0755-83924892 Fax:+86-0755-83924891
E-mail:[email protected]
www.roevisual.com
Table of contents
Other ROE Monitor manuals