EA-1 Instruction Manual Rev.A.doc 20/10/2010
Page 4from 4
Technical specification
Parameter Characteristics Remarks
Reading distance Up to 10 cm for ISO
proximity cards
(dimensions of typical ATM
card) or approx. 5 cm for
proximity tags (key fob)
Reading distance is specified for
model proximity cards in optimal
position against the module, when
card geometrical axis coincides with
loop antenna geometrical axis.
Reading distance can vary
depending on the card type and the
card producer.
Dimensions 85 x 58mm
Connection cable length 1,5m No cable modifications allowed
Environmental conditions Temp.: -25°C- +60°C,
Relative humidity: 10 to
95% (no condensation)
The module requires protection
against rainfalls and can be used
outdoors only if it is protected
against rainfalls.
Certificates CE
This symbol placed on a product or packaging indicates that the product should
not be disposed of with other wastes as this may have a negative impact on the
environment and health. The user is obliged to deliver used equipment to the
designated point of collection of used electric and electronic equipment. For
detailed information on recycling, contact your local authorities, waste disposal
company or point of purchase. Separate collection and recycling of this type of
wastes contributes to the protection of the natural resources and is safe to health
and the environment. Equipment weight is specified in instruction.
Contact information
Roger sp. j.
82-410 Sztum
Gościszewo 59
Tel.: +48 55 272 01 32
Fax: +48 55 272 01 33
PSTN technical support: +48 55 267 01 26
e-mail: biuro@roger.pl