Errata and Supplementary Notes
The following are supplementary notes that explain some important points that have are not in the Owner's Manual.
S-4000R Unit: Error Indicators
++
© 2005 Roland Corporation
All rights reserved. No part of this publication may be reproduced in any form without the written permission of
ROLAND CORPORATION.
Indicator Status Definition Troubleshooting Action
CLIP 1/
SIG 1
Lit The MAIN REAC connection has
failed and the system has
switched to the BACKUP REAC
connection
Check MAIN REAC cabling
Check MAIN REAC connections
Check in-line switching hub (if used) on MAIN REAC connection
Flashing Recovery from the above error None
CLIP 2 Lit An exhaust fan (or fans) on the
Master REAC unit has stopped
working
Shut down the unit to prevent overheating and damage.
Flashing Recovery from the above error None
CLIP 3 Lit Abnormal (high) temperature
detected on the Master REAC
unit
Make sure the intake and/or exhaust vents on the Master REAC unit
are not blocked
Shut down the unit to prevent overheating and damage
Flashing Recovery from the above error None
CLIP 4/
SIG 4
Lit REAC packets error detected on
the unit connected to the S-4000R
Check MAIN and BACKUP REAC cabling
Check MAIN and BACKUP REAC connections
Check in-line switching hub (if used) on MAIN and BACKUP REAC
connections
CLIP 5/
SIG 5
Lit There is a problem with one or
more modules installed in the
S-4000S Master REAC device.
View CLIP and SIG indicators 9-19 to determine the location of the
problem module(s). Refer to the following for more information.
When CLIP 5 and SIG 5 are lit, this indicates that there’s a problem with one or more modules installed in an S-4000S set as the Master
REAC device.
When this occurs, CLIP and SIG indicators 9-19 show the status of any installed modules. Use these indicators to determine the lo-
cation of the problem module(s).
CLIP 9-19 represent A/D modules (SI-AD4, etc.) installed in Slots 1-11.
The S-4000S recognizes an A/D module installed in a particular slot when the following indicators are lit:
• CLIP 9—Slot 1 (leftmost slot)
• CLIP 10—Slot 2
↓
• CLIP 19—Slot 11
SIG 9-19 represent D/A modules (SO-DA4, etc.) installed in Slots 1-11.
The S-4000S recognizes a D/A module installed in a particular slot when the following indicators are lit:
• SIG 9—Slot 1 (leftmost slot)
• SIG 10—Slot 2
↓
• SIG 19—Slot 11
If an A/D or D/A module is installed in one of the slots and the appropriate indicator (CLIP or SIG 9-19) does not light, this
indicates that the S-4000S does not recognize the module. In this case, contact an RSS Authorized Service Center for assistance.
Note: If no module is installed a particular slot location, the CLIP and SIG indicators that represent that slot will not light.
SIG 2 Lit An exhaust fan (or fans) on a
Slave/Split REAC unit has
stopped working
Shut down the unit(s) to prevent overheating and damage
Flashing Recovery from the above error None
SIG 3 Lit Abnormal (high) temperature
detected on a Slave/Split REAC
unit
Make sure the intake and/or exhaust vents on the Slave/Split units
are not blocked
Shut down the unit(s) to prevent overheating and damage
Flashing Recovery from the above error None
LED
Display
Flashes
“Er”
This happens whenever one of
the previously described
S-4000R error indicators lights or
flashes
Look for the source of the error
Press [CLIP CLEAR/ENTER] to return to normal S-4000R operation