RTS ADAM-M User guide

F.01U.216.986 Rev. 10 OCTOBER/2015
ADAM - M
Advanced Digital Audio Matrix
System Installation Guide

Bosch Security Systems, Inc. System Installation Guide F.01U.216.986 Rev. 10
2 ADAM-M System Installation Guide
PROPRIETARY NOTICE
The product information and design disclosed herein were origi-
nated by and are the property of Bosch Security Systems, Inc.
Bosch reserves all patent, proprietary design, manufacturing, repro-
duction, use and sales rights thereto, and to any article disclosed
therein, except to the extent rights are expressly granted to others.
COPYRIGHT NOTICE
Copyright 2012 by Bosch Security Systems, Inc. All rights
reserved. Reproduction, in whole or in part, without prior written
permission from Bosch is prohibited.
*All other trademarks are property of their respective owners.
WARRANTY AND SERVICE INFORMATION
For warranty and service information, refer to the appropriate web
site below:
RTS ............................................... www.rtsintercoms.com/warranty
RTSTW ..................................................... www.rtstw.com/warranty
AudioCom................................. www.telexaudiocom.com/warranty
RadioCom .................................. www.telexradiocom.com/warranty
Headsets ................................ www.intercomheadsets.com/warranty
CUSTOMER SUPPORT
Technical questions should be directed to:
Customer Service Department
Bosch Security Systems, Inc.
12000 Portland Avenue South
Burnsville, MN 55337 USA
Telephone: 877-863-4169
Fax: 800-323-0498
TECHNICAL QUESTIONS EMEA
Bosch Security Systems Technical Support EMEA
http://www.rtsintercoms.com/contact_main.php
DISCLAIMER
THE LIGHTNING
FLASH AND
ARROWHEAD
WITHIN THE
TRIANGLE IS A
WARNING SIGN
ALERTING YOU OF
“DANGEROUS
VOLTAGE” INSIDE
THE PRODUCT.
CAUTION: TO REDUCE
THE RISK OF ELECTRIC
SHOCK, DO NOT REMOVE
COVER. NO USER-
SERVICABLE PARTS
INSIDE. REFER
SERVICING TO
QUALIFIED SERVICE
PERSONNEL.
THE EXCLAMATION
POINT WITHIN THE
TRIANGLE IS A
WARNING SIGN
ALERTING YOU OF
IMPORTANT
INSTRUCTIONS
ACCOMPANYING
THE PRODUCT.
SEE MARKING ON BOTTOM/BACK OF PRODUCT.
WARNING: APPARATUS SHALL NOT BE EXPOSED TO DRIPPING OR
SPLASHING AND NO OBJECTS FILLED WITH LIQUIDS, SUCH AS VASES,
SHALL BE PLACED ON THE APPARATUS.
WARNING: THE MAIN POWER PLUG MUST REMAIN READILY OPERABLE.
CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK, GROUNDING OF
THE CENTER PIN OF THIS PLUG MUST BE MAINTAINED.
WARNING: TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT
EXPOSE THIS APPRATUS TO RAIN OR MOISTURE.
WARNING:TO PREVENT INJURY, THIS APPARATUS MUST BE SECURELY
ATTACHED TO THE FLOOR/WALL/RACK IN ACCORDANCE WITH THE
INSTALLATION INSTRUCTIONS.
This product is AC only.
The manufacturer of the equipment described herein makes
no expressed or implied warranty with respect to anything
contained in this manual and shall not be held liable for any
implied warranties of fitness for a particular application or
for any indirect, special, or consequential damages. The
information contained herein is subject to change without
prior notice and shall not be construed as an expressed or
implied commitment on the part of the manufacturer.

Important Safety Instructions
1. Read these instructions.
2. Keep these instructions.
3. Heed all warnings.
4. Follow all instructions.
5. Do not use this apparatus near water.
6. Clean only with dry cloth.
7. Do not block any ventilation openings. Install in accordance with the
manufacturer’s instructions.
8. Do not install near any heat sources such as radiators, heat registers, stoves,
or other apparatus (including amplifiers) that produce heat.
9. Do not defeat the safety purpose of the polarized or grounding-type plug. A
polarized plug has two blades with one wider than the other. A grounding
type plug has two blades and a third grounding prong. The wide blade or the
third prong are provided for your safety. If the provided plug does not fit
into your outlet, consult an electrician for replacement of the obsolete outlet.
10. Protect the power cord from being walked on or pinched particularly at
plugs, convenience receptacles, and the point where they exit from the
apparatus.
11. Only use attachments/accessories specified by the manufacturer.
12. Use only with the cart, stand, tripod, bracket, or table specified by the
manufacturer, or sold with the apparatus. When a cart is used, use caution
when moving the cart/apparatus combination to avoid injury from tip-over.
13. Unplug this apparatus during lightning storms or when unused for long
periods of time.
14. Refer all servicing to qualified service personnel. Servicing is required
when the apparatus has been damaged in any way, such as power-supply
cord or plug is damaged, liquid has been spilled or objects have fallen into
the apparatus, the apparatus has been exposed to rain or moisture, does not
operate normally, or has been dropped.
Bosch Security Systems, Inc. System Installation Guide
ADAM-M System Installation Guide 3
F.01U.216.986 Rev. 10

Bosch Security Systems, Inc. System Installation Guide F.01U.216.986 Rev. 10
4 ADAM-M System Installation Guide

Table
of
Contents
Bosch Security Systems, Inc. System Installation Guide F.01U.216.986 Rev. 10
INTRODUCTION ......................................................................................................................... 9
General Description .................................................................................................................................9
Features ....................................................................................................................................................9
Reference View ......................................................................................................................................10
Specifications .........................................................................................................................................11
Alarm Operation ....................................................................................................................................12
Status Relay Pin Out .......................................................................................................................................... 12
CHASSIS ..................................................................................................................................... 13
Mounting the Central Matrix Components ............................................................................................13
Initial Setup ............................................................................................................................................15
Checklist before cabling: ................................................................................................................................... 15
ADAM-M Cards ....................................................................................................................................17
Front Card Access ............................................................................................................................................. 17
Card Removal and Installation .......................................................................................................................... 17
Unused Back Card Slots .................................................................................................................................... 19
Supported ADAM-M Configurations ................................................................................................................ 19
Master Controller Card DIP Switches ............................................................................................................... 20
Power Supply Removal and Installation ................................................................................................23
Fan Removal and Replacement ..............................................................................................................24
AC Power - Chassis ...............................................................................................................................25
Fan Air Filter Replacement ....................................................................................................................25
Fuse Replacement ..................................................................................................................................26
ADAM-M Frame Power-Up ..................................................................................................................27
Circuit Card Reset and Fail Indication ...................................................................................................28
XCP-ADAM-MC ......................................................................................................................... 29
Breakout Panel .......................................................................................................................................29
Connector Pinouts ..................................................................................................................................30
Connections .................................................................................................................................................... 32
DEVICE CONNECTIONS ......................................................................................................... 35
General Information ...............................................................................................................................35
Logical Keypanel Numbers ...................................................................................................................36
General Procedure for Connecting Devices to the Intercom .................................................................37
Specifications .....................................................................................................................................................38
Baud Rates for the XCP-ADAM-MC ...............................................................................................................38

Bosch Security Systems, Inc. System Installation Guide
6 ADAM-M System Installation Guide
Rev. 10
F.01U.216.986
Connecting the Master Controller Breakout Panel ............................................................................................ 39
Configuration Computer Connection and Check .............................................................................................. 39
Trunk Master ..................................................................................................................................................... 40
General Description ....................................................................................................................................... 40
Hardware Requirements ................................................................................................................................. 40
Connecting the TM-2000/MTM-2000 ........................................................................................................... 41
UIO-256/GPIO-16 Input/Output Frame ............................................................................................................ 41
Connecting a single UIO-256/GPIO-16 Frame .............................................................................................. 42
Connecting Additional UIO-256/GPIO-16 Frames ....................................................................................... 42
PAP-32 .............................................................................................................................................................. 44
General Description ....................................................................................................................................... 44
Connecting a PAP-32 ..................................................................................................................................... 44
LCP-102 ............................................................................................................................................................ 45
General Description ....................................................................................................................................... 45
Connecting an LCP-102 ................................................................................................................................. 45
RJ-45 BACKCARD .....................................................................................................................57
Notes ......................................................................................................................................................61

List
of
Figures
Bosch Security Systems, Inc. System Installation Guide F.01U.216.986 Rev. 10
FIGURE 1. ADAM-M Reference View ............................................................................................... 10
FIGURE 2. ADAM-M—Proper Carrying Position ............................................................................. 13
FIGURE 3. ADAM-M–Blank Card ..................................................................................................... 19
FIGURE 4. MCII-e Master Controller Card Board View. (Gilman, Mike, illus. 2010) ...................... 20
FIGURE 5. Reset Button and LED Failure Indicator .......................................................................... 28
FIGURE 6. XCP-ADAM-MC (Gilman, Mike, illus. 2010) ................................................................. 29
FIGURE 7. Typical GPI input connection ........................................................................................... 32
FIGURE 8. Typical GPI output connection ......................................................................................... 33
FIGURE 9. Y-Cable Diagram .............................................................................................................. 43
FIGURE 10. Interconnect Cable From ADAM-M ................................................................................ 46
FIGURE 11. Cable to interconnect two (2) LCPs. ................................................................................. 46
FIGURE 12. Keypanel with Data Cabling ............................................................................................. 47
FIGURE 13. Audio Only Cabling .......................................................................................................... 48

Bosch Security Systems, Inc. System Installation Guide F.01U.216.986 Rev. 10
8 ADAM-M System Installation Guide

Bosch Security Systems, Inc. System Installation Guide F.01U.216.986 Rev. 10
CHAPTER 1
Introduction
General Description
Re-engineered with the latest design and technology, the ADAM-M Matrix Intercom bridges legacy with innovation.
The sleek re-design provides 128+ ports in an extremely compact 3 RU (rack unit) package, with full redundancy on the
master controllers and power supplies. The Matrix frame supports current ADAM cards, including AIO-16, RVON-16,
MADI-16 Plus, DBX, TriBus and MCII-e controllers. It also supports existing ADAM wiring schemes and options.
Built for the entire world and the REAL world, the chassis plugs and plays anywhere, running on 90-264VAC at 50/60Hz.
The chassis is built with improved low noise cooling, hot-swappable components (including cooling modules), and improved
status reporting.
Features
Port Density The ADAM-M supports 128+ ports in a 3RU unit, giving more functionality with less rack
space used.
Redundant Master
Controllers
Every ADAM-M is equipped with two (2) master controllers that are fully redundant to each
other, so if one fails the other will take over until the failed controller can be brought back
online.
Power System The ADAM-M has two fully redundant, hot-swappable power supplies that work from 90-
264VAC, 50/60Hz with low noise cooling and advanced status reporting capabilities. UL, CSA,
CE, VDE, FCC and PSE approved.
Compatibility Bridging
with Past and Future
The ADAM-M supports existing legacy products, such as the AIO-16, RVON-16, MCII-e,
Tribus, DBX, and MADI, as well as our next generation of cards.
Extended Back Card
Capabilities
The ADAM-M includes provisions for expanded back cards to increase wiring options and
simplicity.
Integration/Expansion The ADAM-M, utilizing existing cables and bus expanders, integrates and expands existing
intercom systems into larger systems with minimal effort.
Hot Swappable
Components
Not only are the I/O cards in the ADAM-M hot-swappable, but the power supplies and fans are
completely removable and hot swappable, making replacement and maintenance easier than
ever.

10 Introduction ADAM-M System Installation Guide
Bosch Security Systems, Inc. System Installation Guide F.01U.216.986 Rev. 10
Reference View
FIGURE 1. ADAM-M Reference View
1. Status LEDs
2. Front Cover Thumb Screws
3. Alarm Override Button
4. Power Supplies
5. DC Power On/Off Button
6. DC Power On/Off Button
7. Filter Module
8. Power Test Point Banana Jacks
9. Fan Module
10. AC Power Connectors
11. Fuses
12. AC Power On/Off Button
13. Status Relay Connector

ADAM-M System Installation Guide Introduction 11
Bosch Security Systems, Inc. System Installation Guide F.01U.216.986 Rev. 10
Specifications
General
Matrix Size
16-128 ports, frame expandable up to 880 ports
Cards Supported
AIO-16: 16 Analog ports with individual, bi-directional data 15Hz to 20kHz, >90dB A-weighted S/N
MADI-16 Plus: 16 to 64 channels of MADI
RVON-16: 16 VoIP ports supporting G.711, G.729A, and G.723
DBX: Dual Bus Expander for linking between ADAM-M and other ADAM frames.
Tri-Bus: Triple Bus Expander for linking between ADAM-M and other ADAM frames.
MCII-e:Ethernet Master Controllers in redundant configuration.
Electrical
Power Supply
Universal PSU 90V to 264V 50/60Hz
Power Consumption
System dissipation up to 237 Watts
Environmental
Temperature
Operating: 0°C to +50°C (+32°F to +122°F)
Storage: -40°C to +55°C (-40°F to +131°F)
Humidity: 0 to 95% non-condensing
Dimensions
Height: 5.25” (133.35mm) 3RU
Width (frame with rack ears): 19” (482.6mm)
Depth: 20” (508mm)
Weight: 22.05lbs (10.00kg)
Approvals
UL, CSA, CE, VDE, FCC, PSE, REACH, RoHS, WEEE, CCC, ACMA C-Tick, China RoHS, and IECEE CB Scheme
CAUTION:
•Ventilation: Minimum 6” clearance on the sides to keep fan area unobstructed (EN 60065 Clause 4.1.4)
•Apparatus shall not be exposed to dripping or splashing and no objects filled with liquids shall not be placed on
the apparatus (EN 60065 Clause 5.4.1a).
•The ADAM-M is to be connected to a mains socket outlet with a protective earth connection (EN 60065 Clause
5.4.1d).
REFERENCE: For information on ADAM-M Frame accessory specification, consult the individual device’s user manual.
Most user manuals can be found at www.rtsintercoms.com.

12 Introduction ADAM-M System Installation Guide
Bosch Security Systems, Inc. System Installation Guide F.01U.216.986 Rev. 10
Alarm Operation
The ADAM-M is equipped with a power supply fault, fan fault, and over-temperature alarm. If there is a problem detected in
any of these areas, an audible alarm sounds.
Power issue If only one (1) power supply is running, an alarm sounds because redundant power is not active.
Fan issue If any of the three (3) fans stops, an alarm is triggered.
Heat issue If the heat within the chassis goes above 140°F (60°C), an alarm is triggered. There are three (3) heat
sensors in the ADAM M chassis – at the chassis rear, on the backplane, and in the chassis air vent.
The chassis provides an aux alarm relay for when the chassis mounted in unoccupied areas to trigger a remotely located alarm.
Contact closure is given to the connector when a failure is detected.
It is possible to disable these alarms by engaging the Alarm Override button (see Figure 1 on page 10). If the alarm override
switch is engaged, a red ring appears around the button, the alarm is being by-passed and no notification is heard. By
disengaging the alarm override button, the alarm resumes its audible notification.
NOTE:
•The power supply alarm also sounds if a power supply is turned off. This is normal. Either turn on the
power supply, or turn off the alarm override switch.
•Alarm override does not override the alarm for the status relay connection.
Status Relay Pin Out
Relay 1 consists of pins 1, 2, and 6 of the DB-9 Connector.
IMPORTANT: The relay driver must be capable of 5v, 50ma
TABLE 1. DB-9 Pin Out
Pin Description
1NO
2NC
3n/a
4n/a
6Common
7n/a
8n/a
9n/a
.

Bosch Security Systems, Inc. System Installation Guide F.01U.216.986 Rev. 10
CHAPTER 2
Chassis
Mounting the Central Matrix Components
CAUTION: To avoid potentially dropping and damaging the ADAM-M, verify the thumbscrews are secure and be sure to
grasp the front door and the main unit rack ears together when transporting the frame.
FIGURE 2. ADAM-M—Proper Carrying Position

14 Chassis ADAM-M System Installation Guide
Bosch Security Systems, Inc. System Installation Guide F.01U.216.986 Rev. 10
To mount the ADAM-M unit, do the following:
1. Using a flatblade screwdriver, loosen the thumb screws on both sides of the front door. (see Figure 1 on page 10)
2. Remove the front door from the ADAM-M.
3. Bolt the ADAM-M Frame into the front of the equipment rack.
4. Using the rear brackets, bolt the ADAM-M into the back of the equipment rack.
5. Replace the front cover on the ADAM-M.
NOTE: Make sure the ventilation holes on the both sides are unobstructed (minimum 2”). The rack space behind the
ADAM-M Card Frame should be kept completely clear to allow for connections and the insertion and removal
of back cards (at least 2 feet).
Station Breakout Panels and Translation Panels are usually mounted in the back of the equipment rack, and are generally
arranged to allow intercom station cabling to exit the frame at the top or bottom, as required.
Optional UIO-256/GPIO-16 Frames can be mounted in the front of an equipment rack. When positioning a
UIO-256/GPIO-16, consideration should be given to the visibility of the front panel LEDs, which provide visual indication for
any active inputs and outputs.
Optional PAP(Program Assign Panels) units should be mounted in the front of an equipment rack. Generally, a PAP should be
located slightly below eye height when sitting or standing to allow for viewing of the front panel indicators and easy activation
of the front panel controls.

ADAM-M System Installation Guide Chassis 15
Bosch Security Systems, Inc. System Installation Guide F.01U.216.986 Rev. 10
Initial Setup
IMPORTANT: If you are running four (4) cards (including master controllers) or less, verify the Load Card is installed.
Checklist before cabling:
•Verify unit is not damaged
•Verify the power supplies are firmly seated in their slots
•Verify the MCII-e (s) are in slots MC1 and MC2
To set up the ADAM-M, do the following
1. Connect the power cord connector end(s) to the power module on the rear side of the ADAM-M.
2. Connect the power cord plug(s) to an electrical outlet.
3. Using an Ethernet cable, connect the Primary MCII-e (J1) to the computer hosting AZedit.
4. Using an Ethernet cable, connect the Standby MCII-e (J1) to the computer hosting AZedit (optional).
5. Using the appropriate user manuals, cable the specific I/O cards used in your system.
REFERENCE: For a complete list of RTS User Manuals, visit http://www.rtsintercoms.com/manuals.php.
6. Power on the ADAM-M unit.

16 Chassis ADAM-M System Installation Guide
Bosch Security Systems, Inc. System Installation Guide F.01U.216.986 Rev. 10
7. Verify the following Status LEDs are good (on):
•AC/DC Status
•Power Status
•Alarm Status
•Fan Status
8. Using AZedit, verify ADAM is communicating with the computer.

ADAM-M System Installation Guide Chassis 17
Bosch Security Systems, Inc. System Installation Guide F.01U.216.986 Rev. 10
ADAM-M Cards
Front Card Access
To access the front cards, do the following
1. Loosen the thumb screws on both sides of the front door. (see Figure 1 on page 10)
2. Grasp the ADAM-M front cover on each hand hold.
3. Firmly pull the chassis front door from one side.
The other side of the chassis door automatically pops free.
4. Remove the front door and set it aside.
Card Removal and Installation
All ADAM-M circuit cards can be hot-installed, which means you do not have to turn the power off before installing or
removing a card. This permits continuous operation of the intercom system - with no interruptions to unaffected ports - in the
event of a card failure.
NOTE:
•Tribus cards should be placed in slot 5 or slot 6.
•When using MADI cards, place the cards in slots 4 and 8 of the ADAM-M frame for maximum system
reliability.
•If less than four (4) cards are loaded in the ADAM-M (including Master Controllers), use the Load Card
in slot 1. This guarantees power supply redundancy.
CAUTION: The connector pins on the back plane inside the ADAM-M frame can be easily damaged by improper or hurried
insertion of the circuit cards.

18 Chassis ADAM-M System Installation Guide
Bosch Security Systems, Inc. System Installation Guide F.01U.216.986 Rev. 10
To insert back cards, do the following:
1. Orient the card so the component side of the board is facing up.
2. Insert the card edges into the right and left guides in the back of the ADAM-M frame.
3. Push the card in until the mounting plate is flush with the ADAM-M frame.
4. Install mounting screws in the left and right of the card plate to lock it in place.
IMPORTANT: Slots designate MC1 and MC2 are reserved for Master Controllers. Do not install I/O cards in these
slots.
To insert front cards, do the following:
1. Orient the front card so the reset switch is on the left-hand side.
2. Insert the card edges into the right and left card guides in the front of the ADAM-M frame.
3. Push the front card into the slot until initial resistance is felt.
4. When initial resistance is felt, apply slightly more pressure to begin engaging the connector pins.
5. Once the connector pins have started to engage, press firmly to completely seat the connectors.
When the card is properly seated, the card mounting plate should be flush with the ADAM-M frame.
NOTE: Mount screws for the front cards are not required, but are recommended for mobile installations.
To remove a front card, do the following:
1. Press the ejector levers.
2. Once released from the back plane connector, pull the front card straight out of the frame.
To remove a back card, do the following:
1. Release the front card by pressing the ejector levers.
2. Unscrew and remove the back card mounting screws.
3. Remove the back card.
NOTE: When a front or back audio card is removed, the displays on any keypanel connected to that card displays
asterisks instead of the normal key assignments. After a card is reinstalled, it may take a minute or two for the
keypanel displays to return to normal.

ADAM-M System Installation Guide Chassis 19
Bosch Security Systems, Inc. System Installation Guide F.01U.216.986 Rev. 10
Unused Back Card Slots
To ensure proper air flow, each unused back card slot should be fitted with a card blank, shown in Figure 3,
(P/N 9000-7467-003) to cover the opening.
FIGURE 3. ADAM-M–Blank Card
Supported ADAM-M Configurations
The ADAM-M has a limit of only two (2) MADI cards. The following configurations are supported:
TABLE 2. Supported MADI/TBX Configurations for the ADAM-M
ADAM-M with 2 MADI cards and 0 TBX Cards
Place MADI Cards in slots 3 and 6
ADAM-M with 2 MADI cards and 1 TBX Card
Place MADI Cards in slots 3 and 8
Place TBX Card in slot 6
ADAM-M with 2 MADI cards and 2 TBX Cards
Place MADI Cards in slots 3 and 8
Place TBX Cards in slots 5 and 6
ADAM-M with 1 MADI Cardaand 3 TBX Cards
a. When three (3) TBX cards are used in the ADAM-M, only one (1) MADI card can be used in the system.
Place MADI Card in slot 8
Place TBX Cards in slots 4, 5, and 6

20 Chassis ADAM-M System Installation Guide
Bosch Security Systems, Inc. System Installation Guide F.01U.216.986 Rev. 10
Master Controller Card DIP Switches
As shipped from the factory, all master controller card DIP switches are set to the default operation position. These settings are
satisfactory for most applications. Optional settings are summarized in Table 3 on page 21 If any changes are made to the
settings, make sure both the main and backup controller cards are set the same.
FIGURE 4. MCII-e Master Controller Card Board View. (Gilman, Mike, illus. 2010)
Table of contents
Popular Computer Hardware manuals by other brands

Meilhaus Electronic
Meilhaus Electronic ME-6000 Series manual

Arbor Technology
Arbor Technology ETX-PC/104+ Quick installation guide

Kingston Technology
Kingston Technology KHX16C10B1RK2/16X Specifications

Alesis
Alesis airSynth Programming chart

Asus
Asus AAEON EPIC-KBS7 user manual

NXP Semiconductors
NXP Semiconductors OM15080-K32W quick start guide