RugDoctor Mighty PRO X3 User manual

User’s Guide
3 Safety Instructions
5 Cleaning Carpet and Upholstery
7 Maintenance
8 Replacement Parts & Troubleshooting
10 Warranty and Product Registration
11 Rug Doctor Cleaning Products
Retain for your records: To save time if
calling Customer Service for information about
your Rug Doctor® Machine, it is recommended
that you record your machine information here:
Serial # is found inside machine behind the recovery
tank stamped into the body of the machine.
Serial #

2
was founded by a professional carpet cleaner in
1972 with the rst machines having been designed
and built for professional use. A brand was born
and soon after, Rug Doctor launched the rst rental
program that made professional-grade carpet
cleaning machines available to the public. More than
35 years later, Rug Doctor has grown to become
a household name and continues as the leader in
carpet care rental systems with powerful machines
and innovative products.
Rug Doctor, Inc.
4701 Old Shepard Place
Plano, Texas 75093
E-mail: consumer. support@rugdoctor. com
Web Site: www.rugdoctor. com

3
IMPORTANT SAFETY INSTRUCTIONS
Please read all instructions before using. When using an electrical appliance, basic precautions
should always be followed, including the following:
WARNING — To reduce the risk of re, electric shock, or injury:
• Do not leave appliance when plugged in. Unplug from outlet when not in use and before servicing.
• To reduce the risk of re and electric shock due to internal component damage, use only Rug Doctor® cleaning
products intended for use with this appliance. See the Cleaning Product section of this manual.
WARNING— To reduce the risk of electric shock - use indoors only.
• Do not allow to be used as a toy. Close attention is necessary when used by or near children.
• Use only as described in this manual. Use only manufacturer’s recommended attachments.
• Do not use with damaged cord or plug. If appliance is not working as it should, has been dropped, damaged, left
outdoors, or dropped into water, return it to a service center.
• Do not pull or carry by cord, use cord as a handle, close a door on cord, or pull cord around sharp edges or
corners. Do not run appliance over cord. Keep cord away from heated surfaces.
• Do not unplug by pulling on cord. To unplug, grasp the plug, not the cord.
• Do not handle plug or appliance with wet hands.
• Do not put any object into openings. Do not use with any opening blocked; keep free of dust, lint, hair, and
anything that may reduce air ow.
• Keep hair, loose clothing, ngers, and all parts of body away from openings and moving parts.
• Turn off all controls before unplugging.
• Use extra care when cleaning on stairs.
• Do not use to pick up ammable or combustible liquids such as gasoline or use in areas where they may be present.
• Do not use to pick up anything that is burning or smoking, such as cigarettes, matches, or hot ashes.
• Do not use without lters in place.
• Connect to a properly grounded outlet only. See “Grounding Instructions.”
• Use only on surfaces moistened by cleaning process or small spills. Do not place machine in standing water
or try to clear ooded areas.
• Do not clean over oor electrical outlets.
• Do not use without upper (white) tank in place.
• The use of an extension cord is not recommended.
Failure to follow the foregoing instructions may expose the user to electric shock, personal injury and/or death.
SAVE THESE INSTRUCTIONS
Grounding Instructions
This appliance must be grounded. If it should malfunction or breakdown, grounding provides a
path of least resistance for electric current to reduce the risk of electric shock. This appliance
is equipped with a cord having an equipment grounding conductor and grounding plug. The
plug must be inserted into an appropriate outlet that is properly installed and grounded in
accordance with all local codes and ordinances.
WARNING
Improper connection of equipment-grounding conductor can result in a risk of electric shock.
Check with a qualied electrician or service person if you are in doubt as to whether the
outlet is properly grounded. Do not modify the plug provided with the appliance—if it will not
t the outlet, have a proper outlet installed by a qualied electrician. This appliance is for use
on a nominal 120-volt circuit and has a grounded plug that looks like the plug illustrated in
Figure A. Make sure that the appliance is connected to an outlet having the same conguration
as the plug. No adapter should be used with this appliance.
Grounded Outlet Box
Grounded Outlet
ALCI Reset
Grounding Pin
Figure A

4
Cleaning With Your Rug Doctor Machine And Products
Read all instructions completely before you begin. To assure proper results, test carpets and
upholstery for colorfastness. Wet an inconspicuous area with a small amount of cleaner.
After 1–2 minutes, blot with a white paper towel and check for color transfer. Follow these
additional guidelines when cleaning with your Rug Doctor machine:
• Rug Doctor machines and Rug Doctor cleaning products are safe for most carpets. However, you risk damage
to carpets and hard oor surfaces not intended for water extraction method cleaning. Do not use the Rug Doctor
machine or cleaning products on natural ber oriental rugs (silk or wool), hand-loomed wool rugs, braided rugs,
sisal or jute carpets; hardwood or laminate ooring. Some stains require professional treatment. Use cool water
when cleaning wool, wool blends or delicate bers.
• Rug Doctor machines and Rug Doctor cleaning products are safe for many fabrics, even delicate bers. However, you
risk damage to fabrics not intended for water extraction method cleaning. Do not use Rug Doctor machines or
products to clean fabric with cleaning codes S or X, silk, Haitian cotton, velour, brushed corduroy, leather or non-
colorfast fabrics, mattresses or mattress toppers made with memory foam, foam or goose down. Some stains
require professional treatment. Use cool water when cleaning wool, wool blends or delicate bers.
• The machine was designed for use on carpet and upholstery applications in accordance with the instructions and
recommendations in this manual. If you use the Rug Doctor machine to clean surfaces other than carpet and
upholstery, such as hard surface oors, use only Rug Doctor recommended products. Rug Doctor Oxy-Steam® Carpet
Cleaner can be safely and effectively used for either carpeting or water-safe hard surface oor coverings.
• Do NOT put bleach, dye or products other than Rug Doctor cleaners in this machine. Use of inappropriate products
may cause this machine to malfunction and may result in carpet or machine damage.
• Foam should never be ingested through the dome lter. Damage to the carpet and/or vacuum motor could result.
• To Reduce the Risk of Fire and Electric Shock due to internal component damage, use only Rug Doctor®
cleaning products intended for use with this appliance. See the Cleaning Product section of this manual.
An de réduire les risques d’incendie et de décharge électrique provoqués par des composants internes endommagés,
utilisez uniquement les produits de nettoyage Rug Doctor conçus pour ce produit. Lire la section consacrée aux
produits de nettoyage dans le présent manuel.
• Avoid picking up hard or sharp objects with the carpet cleaning machine. They may damage the machine. Do not
use the machine for dry vacuuming because this machine does not have a ne dust lter. Dry vacuuming damages the
vacuum motor.
• Do not use the machine to vacuum large quantities of liquid, such as a ooded basement or large spill. This machine is
not equipped with an automatic overow shutoff.
• To avoid damage, do not place the machine or hand tool on hardwood or laminate ooring or allow any solution or
overspray to contact such ooring.
• To avoid pump damage, do not continue to press the spray (pump) switch when the solution tank is empty.
Read instructions carefully. Rug Doctor, Inc. is not responsible for damage due to misuse of this machine.
Carpet Cleaning Tips For Best Results
• Treating difcult spots. Rug Doctor machines are designed to deep clean and extract in one cleaning pass. Your best
choice for cleaning difcult spots, stains or trafc areas is to use Rug Doctor’s specialty products: Hi-Trafc Pre-
Treatment, Spot & Stain Remover, Urine Eliminator, or Odor Remover.
• Avoid over-wetting your carpet. Don’t go over a heavily-soiled spot more than 2 times. Berber, Multi-Level or Looped
carpets retain more liquid. For these types of carpets, DO NOT repeat cleaning passes. If additional cleaning is desired,
allow carpets to dry before attempting to reclean heavily-soiled areas. Because they retain more liquid, Berber carpets
that are overwet can experience “wick up” of soils or spills very deeply embedded in the carpet or backing. If you
experience this problem, allow area to dry completely then clean again using single, quick passes (1-2 feet per second).
• Cleaning Berber carpet; You can use your Rug Doctor machine to clean Berber carpet. For best results, make only
one pass while depressing the thumb switch to release solution. Make a second pass over the same area without
pressing the switch so that you are only vacuuming the liquid. Make sure the vacuum slot at the front bottom edge
of the machine is snug against the carpet.
• Overlap passes slightly to cover all areas. IMPORTANT: When pressing the red button, keep machine moving so
vibrating brush does not agitate in one place.
• Liquid recovery. You should recover 70 - 80% of the liquid used depending on your carpet type. With Berber carpet, you
may recover a little less liquid.
• Avoid excessive foam in the recovery tank, which can be expelled through the machine and may affect your carpet. If
foaming occurs turn off the machine and empty the upper white tank if it is full.
• If you replace furniture before the carpet is completely dry, place aluminum foil under furniture legs to prevent stains.
Leave aluminum foil under furniture legs until carpet is completely dry.
• For faster drying, ventilate area. Open doors and windows. Place fans pointed downward on carpet. Turn on heat in
damp or cold weather. Turn on air conditioner in humid or hot weather. This is highly recommended when cleaning
Berber carpets.

5
Before You Begin
Review machine safety warnings found in
the front of this manual. Using a normal dry
vacuum cleaner, vacuum the area you want
to clean to remove loose dirt before using
the Rug Doctor machine. This will help
keep the brushes and water vacuum system
working efciently. Pre-treat any special
problem areas with appropriate Rug Doctor
solutions. For example, use Urine Eliminator
on tough pet stains and other bio-origin
stains.
Set Up
Check the back of the machine to ensure
hose connections are secure and set to
clean carpet instead of upholstery (ILLUS.1)
Lift up on the recovery latch and raise dome
hood (ILLUS.2). Remove the recovery tank.
Depending on how dirty your carpets are,
add 2oz- 4oz (1/4 to 1/2) cup of Rug Doctor
Oxy-Steam® Carpet Cleaner product per
gallon of hot tap water in a clean bucket
(ILLUS.3). Use caution to insure water is not
so hot as to scald or burn skin.
The lower tank capacity for the Rug Doctor
Mighty Pro X3™ is 3 gallons. Fill the lower
tank with the Rug Doctor Oxy-Steam®
Cleaning solution by pouring through the
white lter screen. Machine is full when
liquid halfway covers the lter screen
(ILLUS.4). Replace recovery tank and close
the dome hood (ILLUS.2).
Plug in the power cord and position the
machine. Refer to the label on the side of
the handle. Slide the switch to the “Carpet”
position for carpet cleaning (ILLUS.5).
Cleaning Carpets
(ILLUS.1)
(ILLUS.2)
(ILLUS.3)
(ILLUS.4)
(ILLUS.5)
(ILLUS.6)
(ILLUS.7)
(ILLUS.8)
(ILLUS.9)
press for spray
tool / 0 /carpet “0” is off position
reset button is located below
recovery latch
& dome hood
recovery tank lower tank
vacuum slot
(bottom edge
of machine)
dome lter
handle release
Start Cleaning
While depressing the press for spray red button
on the top of the handle (ILLUS.6), pull the
machine slowly and steadily backward in a
straight line, keeping vacuum slot against the
carpet surface. On lightly soiled carpets you can
pull the machine quickly at one foot per second.
For moderately, or heavily soiled carpets, pull
the machine at approximately one foot every two
seconds. You will begin to see soiled solution
entering the clear dome. (If you don’t, stop and
refer to the Troubleshooting section).
IMPORTANT: When depressing the press for
spray red button, keep machine moving so the
vibrating brush does not agitate in one place
(ILLUS.7).
Release the red button 6 to 12 inches before
ending each pass to stop cleaning solution. Tilt
machine back and push it forward to start a new
backward cleaning pass (ILLUS.8).
Continue cleaning in this manner, overlapping
each pass slightly. When the lower tank runs
out of cleaning solution, the pump sound will
increase in volume slightly and dirty water will
stop entering the dome. Switch the machine to
“0” for the off position. Remove and empty the
recovery tank by pouring dirty solution into a
toilet or outdoors (ILLUS.9).
Rinse the recovery tank and rell the lower tank
with clean solution/water mixture using a clean
bucket. If you are near the end of your cleaning
job, ll the lower tank half full so it empties by
the end of your job. Replace the recovery tank.
Continue the cleaning process until area to be
cleaned is covered. When cleaning is complete,
switch the machine to “0” for the off position. To
drain and clean the machine, please refer to the
Maintaining Your Rug Doctor Machine section.
To learn more about how to clean your carpets, refer to “Using your Rug Doctor” section on www.rugdoctor.com
Other manuals for Mighty PRO X3
6
Table of contents
Languages:
Other RugDoctor Floor Machine manuals