Ruud RQNA-B024JK User manual

FORM NO. P22-764 REV. 3
Supersedes Form No. P22-764 Rev. 2
RQNA-B HIGH EFFICIENCY 13-SEER SERIES
NOMINAL SIZES 2-4 TONS [7.03-14.07 kW]
PACKAGE HEAT PUMPS

2
TABLE OF CONTENTS
Unit Features & Benefits ..............................................................................3-4
Model Identification Options ..........................................................................5-6
General Data
RQNA-B Series ........................................................................................7-8
General Data Notes ........................................................................................9
Performance Data
RQNA-B Series ....................................................................................10-14
Airflow Performance
RQNA-B Series ....................................................................................15-16
Electrical Data
RQNA-B Series ........................................................................................17
Electric Heater Kits ..................................................................................18-19
Dimensional Data ....................................................................................20-21
Typical Installations ......................................................................................22
Accessories ............................................................................................23-30
Typical Wiring ..........................................................................................31-34
Limited Warranty ..........................................................................................36

UNIT FEATURES & BENEFITS—RQNA-B
These quality features are included in the Ruud
Outdoor Package Heat Pumps
4
5
3

4
UNIT FEATURES & BENEFITS—RQNA-B SERIES
1. All models feature Copeland®Scroll®compressors for
maximum efficiency and quiet operation.
2. Louvered condenser compartment for protecting the
coil against yard hazards and/or weather extremes.
3. One-piece top with a deep flange to help keep water
out of the unit.
4. Supply and return air openings feature a one-inch tall
flange to prevent water migration into the ductwork.
5. Access panels have “weep holes” and channels to
further help manage water run-off.
6. Side and down discharge options available on all
models. (Shipped Downflow Standard).
7. Easily accessible blower section complete with slide-
out blower. All units feature a system matched indoor
coil with low static pressure drop and excellent cooling
capacities.
8. Refrigerant connections are conveniently located for
easy service diagnostics.
9. Condenser and evaporator coils feature enhanced
fins for better heat transfer and rifled copper tubing for
greater efficiency.
10. Supplemental electric heat strips up to 15 kW are
available (field or factory installed) for periods of
extreme cold temperatures. Single point wiring makes
installation even easier.
11. All units feature an internal trap on the condensate
line eliminating the need for installing an on-site
external trap.
12. Easily accessible control box.
Features Below Correspond to Photos on Page 3

R Q N A — B036 J K 000 XXX
Factory Installed Options
(See Next Page)
Heating Capacity (Factory Installed)
000 = No Resistance Heat
005 = 05 KW Resistance Heat (018-030)
010 = 10 KW Resistance Heat (024-048)
015 = 15 KW Resistance Heat (036-048)
Drive Package
K = Direct Drive
Electrical Designation
J = 208-230V—1PH—60 Hz
C = 208-230V—3PH—60 Hz
Cooling Capacity (BTUH) [kW]
024 = 24,000 [7.03]
030 = 30,000 [8.79]
036 = 36,000 [10.55]
042 = 42,000 [12.31]
048 = 48,000 [14.07]
Design Series
A = 1st Design
Efficiency Designation
N = 13 SEER High Efficiency
Product Classification
Q = Package Heat Pump
Tradebrand
R = Ruud
[ ] Designates Metric Conversions
5
MODEL IDENTIFICATION—RQNA-B SERIES

6
OPTIONS—RQNA-B SERIES
Option
Code Side Flow
AA No Option
AKA x
FACTORY INSTALLED OPTION CODES
Example: RQNA-B036JK000XX (where XX is factory installed option)
Example: No Options
RQNA-B036JK000
Example: Options with Sideflow
RQNA-B036JK000AKA
Note: Factory installed economizer is not available on these models.
Instructions for Factory Installed Option(s) Selection
Note: Two characters following the model number will be utilized to designate a factory-installed option or com-
bination of options. If no factory option(s) is required, nothing follows the model number.
Step 1. After a basic rooftop model is selected, choose a two-character option code from the FACTORY
INSTALLED OPTION SELECTION TABLE.

7
GENERAL DATA—RQNA-B SERIES
NOMINAL SIZES 2-4 TONS [7.03-14.07 kW]
Model RQNA-B Series B024JK B030JK B036CK B036JK
Cooling Performance1
Gross Cooling Capacity Btu [kW] 24,400 [7.15] 31,400 [9.2] 36,600 [10.72] 36,600 [10.72]
EER/SEER211/13 11/13 11/13 11/13
Nominal CFM/ARI Rated CFM [L/s] 800/800 [378/378] 1000/1050 [472/495] 1200/1200 [566/566] 1200/1200 [566/566]
ARI Net Cooling Capacity Btu [kW] 23,600 [6.91] 30,200 [8.85] 35,400 [10.37] 35,400 [10.37]
Net Sensible Capacity Btu [kW] 17,900 [5.24] 22,100 [6.48] 26,300 [7.71] 26,300 [7.71]
Net System Power kW 2.14 2.74 3.22 3.22
Heating Performance (Heat Pumps)
Heating Input Btu [kW] Rating 23,000 [6.74] 29,000 [8.5] 34,200 [10.02] 34,200 [10.02]
System Power KW/COP 1.95/3.4 2.44/3.4 2.91/3.4 2.91/3.4
Low Temp. Btuh [kW] Rating 12,900 [3.78] 16,100 [4.72] 19,500 [5.71] 19,500 [5.71]
Net Weight lbs. [kg] 391 [177] 444 [201] 471 [214] 468 [212]
System Power KW/COP 1.89/2 2.29/2 2.72/2.1 2.72/2.1
Refrigerant Control TX Valves TX Valves TX Valves TX Valves
HSPF (Btu/Watts-hr) 7.7 7.7 7.7 7.7
Compressor
No./Type 1/Copeland Scroll 1/Copeland Scroll 1/Copeland Scroll 1/Copeland Scroll
Outdoor Sound Rating (dB)376 76 76 76
Outdoor Coil—Fin Type Louvered Louvered Louvered Louvered
Tube Type Rifled Rifled Rifled Rifled
Tube Size in. [mm] OD 0.375 [9.5] 0.375 [9.5] 0.375 [9.5] 0.375 [9.5]
Face Area sq. ft. [sq. m] 14.51 [1.35] 16.32 [1.52] 11.2 [1.04] 11.2 [1.04]
Rows / FPI [FPcm] 1 / 22 [9] 1 / 22 [9] 2 / 22 [9] 2 / 22 [9]
Net Latent Capacity Btu [kW] 5,700 [1.67] 8,100 [2.37] 9,100 [2.67] 9,100 [2.67]
Indoor Coil—Fin Type Louvered Louvered Louvered Louvered
Tube Type Rifled Rifled Rifled Rifled
Tube Size in. [mm] 0.375 [9.5] 0.375 [9.5] 0.375 [9.5] 0.375 [9.5]
Face Area sq. ft. [sq. m] 5.54 [0.51] 7.39 [0.69] 7.39 [0.69] 7.39 [0.69]
Rows / FPI [FPcm] 2 / 15 [6] 2 / 15 [6] 2 / 15 [6] 2 / 15 [6]
Refrigerant Control TX Valves TX Valves TX Valves TX Valves
Drain Connection No./Size in. [mm] 1/1 [25.4] 1/1 [25.4] 1/1 [25.4] 1/1 [25.4]
Outdoor Fan—Type Propeller Propeller Propeller Propeller
No. Used/Diameter in. [mm] 1/22 [558.8] 1/22 [558.8] 1/22 [558.8] 1/22 [558.8]
Drive Type/No. Speeds Direct/1 Direct/1 Direct/1 Direct/1
CFM [L/s] 2700 [1274] 2700 [1274] 2700 [1274] 2700 [1274]
No. Motors/HP 1 at 1/5 HP 1 at 1/5 HP 1 at 1/5 HP 1 at 1/5 HP
Motor RPM 1075 1075 1075 1075
Indoor Fan—Type FC Centrifugal FC Centrifugal FC Centrifugal FC Centrifugal
No. Used/Diameter in. [mm] 1/9x7 [228.6x177.8] 1/10x9 [254x228.6] 1/10x9 [254x228.6] 1/10x9 [254x228.6]
Drive Type/No. Speeds Direct/2 Direct/3 Direct/1 Direct/1
No. Motors 1 1 1 1
Motor HP 1/4 1/2 1/3 1/3
Motor RPM 1075 1075 1075 1075
Motor Frame Size 48 48 48 48
Filter—Type Field Supplied Field Supplied Field Supplied Field Supplied
Furnished No No No No
(No.) Size Recommended in. [mm] (1)1x20x20 [25x508x508] (1)1x24x24 [25x610x610] (1)1x24x24 [25x610x610] (1)1x24x24 [25x610x610]
Refrigerant Charge Oz. [g] 86 [2438] 93 [2637] 122 [3459] 122 [3459]
Weights
Ship Weight lbs. [kg] 401 [182] 455 [206] 482 [219] 479 [217]
CONTINUED
See Page 9 for Notes. [ ] Designates Metric Conversions

8
GENERAL DATA—RQNA-B SERIES
Model RQNA-B Series B042CK B042JK B048CK B048JK
Cooling Performance1
Gross Cooling Capacity Btu [kW] 44,500 [13.04] 44,500 [13.04] 50,000 [14.65] 50,000 [14.65]
EER/SEER211/13 11/13 11/13 11/13
Nominal CFM/ARI Rated CFM [L/s] 1400/1400 [661/661] 1400/1400 [661/661] 1600/1600 [755/755] 1600/1600 [755/755]
ARI Net Cooling Capacity Btu [kW] 43,500 [12.75] 43,500 [12.75] 48,500 [14.21] 48,500 [14.21]
Net Sensible Capacity Btu [kW] 31,800 [9.32] 31,800 [9.32] 36,000 [10.55] 36,000 [10.55]
Net System Power kW 3.96 3.96 4.41 4.41
Heating Performance (Heat Pumps)
Heating Input Btu [kW] Rating 39,500 [11.57] 39,500 [11.57] 46,000 [13.48] 46,000 [13.48]
System Power KW/COP 3.34/3.4 3.34/3.4 4.11/3.28 4.11/3.28
Low Temp. Btuh [kW] Rating 22,800 [6.68] 22,800 [6.68] 27,400 [8.03] 28,000 [8.2]
Net Weight lbs. [kg] 508 [230] 505 [229] 500 [227] 510 [231]
System Power KW/COP 3.18/2.1 3.18/2.1 3.86/2.08 3.86/2.08
Refrigerant Control TX Valves TX Valves TX Valves TX Valves
HSPF (Btu/Watts-hr) 7.7 7.7 7.7 7.7
Compressor
No./Type 1/Copeland Scroll 1/Copeland Scroll 1/Copeland Scroll 1/Copeland Scroll
Outdoor Sound Rating (dB)376 76 78 78
Outdoor Coil—Fin Type Louvered Louvered Louvered Louvered
Tube Type Rifled Rifled Rifled Rifled
Tube Size in. [mm] OD 0.375 [9.5] 0.375 [9.5] 0.375 [9.5] 0.375 [9.5]
Face Area sq. ft. [sq. m] 16.32 [1.52] 16.32 [1.52] 16.32 [1.52] 16.32 [1.52]
Rows / FPI [FPcm] 2 / 22 [9] 2 / 22 [9] 2 / 22 [9] 2 / 22 [9]
Net Latent Capacity Btu [kW] 11,700 [3.43] 11,700 [3.43] 12,500 [3.66] 12,500 [3.66]
Indoor Coil—Fin Type Louvered Louvered Louvered Louvered
Tube Type Rifled Rifled Rifled Rifled
Tube Size in. [mm] 0.375 [9.5] 0.375 [9.5] 0.375 [9.5] 0.375 [9.5]
Face Area sq. ft. [sq. m] 7.39 [0.69] 7.39 [0.69] 7.39 [0.69] 7.39 [0.69]
Rows / FPI [FPcm] 2 / 15 [6] 2 / 15 [6] 2 / 15 [6] 2 / 15 [6]
Refrigerant Control TX Valves TX Valves TX Valves TX Valves
Drain Connection No./Size in. [mm] 1/1 [25.4] 1/1 [25.4] 1/1 [25.4] 1/1 [25.4]
Outdoor Fan—Type Propeller Propeller Propeller Propeller
No. Used/Diameter in. [mm] 1/22 [558.8] 1/22 [558.8] 1/22 [558.8] 1/22 [558.8]
Drive Type/No. Speeds Direct/1 Direct/1 Direct/1 Direct/1
CFM [L/s] 3300 [1557] 3300 [1557] 3000 [1416] 3000 [1416]
No. Motors/HP 1 at 1/3 HP 1 at 1/3 HP 1 at 1/3 HP 1 at 1/3 HP
Motor RPM 1075 1075 1075 1075
Indoor Fan—Type FC Centrifugal FC Centrifugal FC Centrifugal FC Centrifugal
No. Used/Diameter in. [mm] 1/10x9 [254x228.6] 1/10x9 [254x228.6] 1/10x9 [254x228.6] 1/10x9 [254x228.6]
Drive Type/No. Speeds Direct/2 Direct/2 Direct/2 Direct/2
No. Motors 1 1 1 1
Motor HP 3/4 3/4 3/4 3/4
Motor RPM 1075 1075 1725 1075
Motor Frame Size 48 48 48 48
Filter—Type Field Supplied Field Supplied Field Supplied Field Supplied
Furnished No No No No
(No.) Size Recommended in. [mm] (1)1x24x24 [25x610x610] (1)1x24x24 [25x610x610] (1)1x24x24 [25x610x610] (1)1x24x24 [25x610x610]
Refrigerant Charge Oz. [g] 158 [4479] 158 [4479] 150 [4252] 150 [4252]
Weights
Ship Weight lbs. [kg] 519 [235] 516 [234] 511 [232] 521 [236]
NOMINAL SIZES 2-4 TONS [7.03-14.07 kW]
See Page 9 for Notes. [ ] Designates Metric Conversions

NOTES:
1. Cooling Performance is rated at 95° F ambient, 80° F entering dry bulb, 67° F entering wet bulb. Gross capacity does not
include the effect of fan motor heat. ARI capacity is net and includes the effect of fan motor heat. Units are suitable for
operation in CFM range shown in airflow tables. Units are certified in accordance with the Unitary Air Conditioner
Equipment certification program, which is based on ARI Standard 210/240 or 360.
2. EER and/or SEER are rated at ARI conditions and in accordance with DOE test procedures.
3. Outdoor Sound Rating shown is tested in accordance with ARI Standard 270.
9
GENERAL DATA—RQNA-B SERIES

COOLING PERFORMANCE DATA—RQNA-B024
ENTERING INDOOR AIR @ 80°F [26.7°C] dbE ➀
wbE 71°F [21.7°C] 67°F [19.4°C] 63°F [17.2°C]
CFM [L/s] 900 [425] 800 [378] 700 [330] 900 [425] 800 [378] 700 [330] 900 [425] 800 [378] 700 [330]
DR ➀.19 .16 .11 .19 .16 .11 .19 .16 .11
O
U
T
D
O
O
R
D
R
Y
B
U
L
B
T
E
M
P
E
R
A
T
U
R
E
°F
[°C]
75
[23.9]
Total BTUH [kW]
Sens BTUH [kW]
Power
31.4 [9.20]
18.2 [5.33]
1.6
30.7 [9.00]
17.2 [5.04]
1.5
30.0 [8.79]
16.2 [4.75]
1.5
29.1 [8.53]
21.6 [6.33]
1.6
28.4 [8.32]
20.4 [5.98]
1.5
27.8 [8.15]
19.2 [5.63]
1.5
28.6 [8.38]
23.3 [6.83]
1.5
28.0 [8.21]
22.0 [6.45]
1.5
27.4 [8.03]
20.7 [6.07]
1.5
80
[26.7]
Total BTUH [kW]
Sens BTUH [kW]
Power
30.5 [8.94]
18.0 [5.28]
1.6
29.8 [8.73]
17.0 [4.98]
1.6
29.2 [8.56]
16.0 [4.69]
1.6
28.2 [8.26]
21.4 [6.27]
1.6
27.6 [8.09]
20.2 [5.92]
1.6
27.0 [7.91]
19.0 [5.57]
1.6
27.8 [8.15]
23.1 [6.77]
1.6
27.2 [7.97]
21.8 [6.39]
1.6
26.5 [7.77]
20.5 [6.01]
1.6
85
[29.4]
Total BTUH [kW]
Sens BTUH [kW]
Power
29.5 [8.65]
17.6 [5.16]
1.7
28.8 [8.44]
16.6 [4.86]
1.7
28.2 [8.26]
15.7 [4.60]
1.7
27.2 [7.97]
21.0 [6.15]
1.7
26.6 [7.80]
19.8 [5.80]
1.7
26.0 [7.62]
18.7 [5.48]
1.7
26.8 [7.85]
22.7 [6.65]
1.7
26.2 [7.68]
21.4 [6.27]
1.7
25.6 [7.50]
20.2 [5.92]
1.7
90
[32.2]
Total BTUH [kW]
Sens BTUH [kW]
Power
28.4 [8.32]
17.1 [5.01]
1.8
27.8 [8.15]
16.1 [4.72]
1.8
27.1 [7.94]
15.2 [4.45]
1.8
26.1 [7.65]
20.4 [5.98]
1.8
25.5 [7.47]
19.3 [5.66]
1.8
25.0 [7.33]
18.2 [5.33]
1.8
25.7 [7.53]
22.1 [6.48]
1.8
25.1 [7.36]
20.9 [6.13]
1.8
24.5 [7.18]
19.7 [5.77]
1.8
95
[35]
Total BTUH [kW]
Sens BTUH [kW]
Power
27.3 [8.00]
16.5 [4.84]
1.9
26.7 [7.83]
15.6 [4.57]
1.9
26.1 [7.65]
14.7 [4.31]
1.9
25.0 [7.33]
19.9 [5.83]
1.9
24.5 [7.18]
18.8 [5.51]
1.9
23.9 [7.00]
17.7 [5.19]
1.9
24.6 [7.21]
21.6 [6.33]
1.9
24.0 [7.03]
20.4 [5.98]
1.9
23.5 [6.89]
19.2 [5.63]
1.9
100
[37.8]
Total BTUH [kW]
Sens BTUH [kW]
Power
26.3 [7.71]
15.9 [4.66]
2.0
25.7 [7.53]
15.0 [4.40]
2.0
25.1 [7.36]
14.1 [4.13]
2.0
24.0 [7.03]
19.2 [5.63]
2.0
23.5 [6.89]
18.2 [5.33]
2.0
22.9 [6.71]
17.1 [5.01]
2.0
23.5 [6.89]
20.9 [6.13]
2.0
23.0 [6.74]
19.8 [5.80]
2.0
22.5 [6.59]
18.6 [5.45]
2.0
105
[40.6]
Total BTUH [kW]
Sens BTUH [kW]
Power
25.4 [7.44]
15.3 [4.48]
2.1
24.9 [7.30]
14.5 [4.25]
2.1
24.3 [7.12]
13.6 [3.99]
2.0
23.1 [6.77]
18.7 [5.48]
2.1
22.6 [6.62]
17.6 [5.16]
2.1
22.1 [6.48]
16.6 [4.86]
2.0
22.7 [6.65]
20.4 [5.98]
2.1
22.2 [6.51]
19.2 [5.63]
2.1
21.7 [6.36]
18.1 [5.30]
2.0
110
[43.3]
Total BTUH [kW]
Sens BTUH [kW]
Power
24.8 [7.27]
14.8 [4.34]
2.2
24.3 [7.12]
14.0 [4.10]
2.2
23.7 [6.95]
13.2 [3.87]
2.1
22.5 [6.59]
18.1 [5.30]
2.2
22.0 [6.45]
17.1 [5.01]
2.2
21.5 [6.30]
16.1 [4.72]
2.1
22.1 [6.48]
19.8 [5.80]
2.2
21.6 [6.33]
18.7 [5.48]
2.1
21.1 [6.18]
17.7 [5.19]
2.1
115
[46.1]
Total BTUH [kW]
Sens BTUH [kW]
Power
24.5 [7.18]
14.4 [4.22]
2.3
24.0 [7.03]
13.6 [3.99]
2.2
23.4 [6.86]
12.8 [3.75]
2.2
22.2 [6.51]
17.8 [5.22]
2.3
21.7 [6.36]
16.8 [4.92]
2.2
21.3 [6.24]
15.8 [4.63]
2.2
21.8 [6.39]
19.5 [5.71]
2.3
21.3 [6.24]
18.4 [5.39]
2.2
20.8 [6.10]
17.3 [5.07]
2.2
HEATING PERFORMANCE DATA—RQNA-B024
IDB 60°F [15.5°C] 70°F [21.1°C] 80°F [26.7°C]
CFM [L/s] 900 [425] 800 [378] 700 [330] 900 [425] 800 [378] 700 [330] 900 [425] 800 [378] 700 [330]
O
U
T
D
O
O
R
D
R
Y
B
U
L
B
T
E
M
P
E
R
A
T
U
R
E
°F
[°C]
0
[-17.8]
Total BTUH [kW]
Power
7.8 [2.29]
1.2
7.7 [2.26]
1.2
7.6 [2.23]
1.3
7.1 [2.08]
1.4
7.0 [2.05]
1.4
7.0 [2.05]
1.5
5.8 [1.70]
1.5
5.8 [1.70]
1.6
5.7 [1.67]
1.6
5
[-15]
Total BTUH [kW]
Power
9.4 [2.75]
1.3
9.3 [2.73]
1.3
9.2 [2.70]
1.3
8.7 [2.55]
1.4
8.6 [2.52]
1.5
8.5 [2.49]
1.5
7.4 [2.17]
1.6
7.3 [2.14]
1.6
7.3 [2.14]
1.6
15
[-9.4]
Total BTUH [kW]
Power
12.4 [3.63]
1.3
12.3 [3.60]
1.3
12.2 [3.58]
1.4
11.7 [3.43]
1.5
11.6 [3.40]
1.5
11.5 [3.37]
1.5
10.4 [3.05]
1.6
10.3 [3.02]
1.7
10.2 [2.99]
1.7
10
[-12.2]
Total BTUH [kW]
Power
10.9 [3.19]
1.3
10.8 [3.17]
1.3
10.7 [3.14]
1.3
10.2 [2.99]
1.5
10.1 [2.96]
1.5
10.0 [2.93]
1.5
8.9 [2.61]
1.6
8.9 [2.61]
1.6
8.8 [2.58]
1.6
25
[-3.9]
Total BTUH [kW]
Power
15.4 [4.51]
1.4
15.3 [4.48]
1.4
15.1 [4.43]
1.4
14.7 [4.31]
1.6
14.6 [4.28]
1.6
14.4 [4.22]
1.6
13.4 [3.93]
1.7
13.3 [3.90]
1.7
13.2 [3.87]
1.7
35
[1.7]
Total BTUH [kW]
Power
18.6 [5.45]
1.4
18.4 [5.39]
1.4
18.3 [5.36]
1.5
17.9 [5.25]
1.6
17.7 [5.19]
1.6
17.6 [5.16]
1.7
16.6 [4.86]
1.7
16.5 [4.84]
1.8
16.3 [4.78]
1.8
20
[-6.7]
Total BTUH [kW]
Power
13.9 [4.07]
1.3
13.8 [4.04]
1.4
13.6 [3.99]
1.4
13.2 [3.87]
1.5
13.1 [3.84]
1.6
13.0 [3.81]
1.6
11.9 [3.49]
1.7
11.8 [3.46]
1.7
11.7 [3.43]
1.7
30
[-1.1]
Total BTUH [kW]
Power
17.0 [4.98]
1.4
16.8 [4.92]
1.4
16.7 [4.89]
1.4
16.3 [4.78]
1.6
16.1 [4.72]
1.6
16.0 [4.69]
1.6
15.0 [4.40]
1.7
14.9 [4.37]
1.7
14.7 [4.31]
1.8
40
[4.4]
Total BTUH [kW]
Power
20.3 [5.95]
1.4
20.2 [5.92]
1.5
20.0 [5.86]
1.5
19.7 [5.77]
1.6
19.5 [5.71]
1.7
19.3 [5.66]
1.7
18.4 [5.39]
1.8
18.2 [5.33]
1.8
18.1 [5.30]
1.8
50
[10]
Total BTUH [kW]
Power
24.3 [7.12]
1.5
24.1 [7.06]
1.5
23.9 [7.00]
1.5
23.6 [6.92]
1.7
23.4 [6.86]
1.7
23.2 [6.80]
1.7
22.3 [6.54]
1.8
22.1 [6.48]
1.8
21.9 [6.42]
1.9
45
[7.2]
Total BTUH [kW]
Power
22.2 [6.51]
1.5
22.0 [6.45]
1.5
21.8 [6.39]
1.5
21.5 [6.30]
1.7
21.3 [6.24]
1.7
21.2 [6.21]
1.7
20.3 [5.95]
1.8
20.1 [5.89]
1.8
19.9 [5.83]
1.8
IDB—Indoor air dry bulb [ ] Designates Metric Conversions
NOTES:
➀When the entering air dry bulb is other than 80°F [27°C], adjust the sensible
capacity from the table by adding [1.10 x CFM x (1 – DR) x (dbE – 80)].
DR —Depression ratio
dbE —Entering air dry bulb
wbE—Entering air wet bulb
Total —Total capacity x 1000 BTUH
Sens —Sensible capacity x 1000 BTUH
Power—KW input
10
SYSTEMS PERFORMANCE—RQNA-B SERIES

11
COOLING PERFORMANCE DATA—RQNA-B030
ENTERING INDOOR AIR @ 80°F [26.7°C] dbE ➀
wbE 71°F [21.7°C] 67°F [19.4°C] 63°F [17.2°C]
CFM [L/s] 1180 [557] 1050 [496] 920 [434] 1180 [557] 1050 [496] 920 [434] 1180 [557] 1050 [496] 920 [434]
DR ➀.19 .16 .11 .19 .16 .11 .19 .16 .11
O
U
T
D
O
O
R
D
R
Y
B
U
L
B
T
E
M
P
E
R
A
T
U
R
E
°F
[°C]
75
[23.9]
Total BTUH [kW]
Sens BTUH [kW]
Power
37.6 [11.02]
22.4 [6.56]
1.9
36.8 [10.79]
21.2 [6.21]
1.9
35.9 [10.52]
19.9 [5.83]
1.9
35.2 [10.32]
26.5 [7.77]
1.9
34.4 [10.08]
25.0 [7.33]
1.9
33.6 [9.85]
23.6 [6.92]
1.9
34.1 [9.99]
28.8 [8.44]
1.9
33.3 [9.76]
27.2 [7.97]
1.9
32.5 [9.52]
25.6 [7.50]
1.9
80
[26.7]
Total BTUH [kW]
Sens BTUH [kW]
Power
37.4 [10.96]
22.4 [6.56]
2.1
36.6 [10.73]
21.2 [6.21]
2.0
35.7 [10.46]
19.9 [5.83]
2.0
35.0 [10.26]
26.5 [7.77]
2.1
34.2 [10.02]
25.0 [7.33]
2.0
33.5 [9.82]
23.6 [6.92]
2.0
33.9 [9.94]
28.8 [8.44]
2.1
33.1 [9.70]
27.2 [7.97]
2.0
32.4 [9.50]
25.6 [7.50]
2.0
85
[29.4]
Total BTUH [kW]
Sens BTUH [kW]
Power
36.7 [10.76]
22.0 [6.45]
2.2
35.9 [10.52]
20.8 [6.10]
2.2
35.1 [10.29]
19.6 [5.74]
2.1
34.4 [10.08]
26.1 [7.65]
2.2
33.6 [9.85]
24.7 [7.24]
2.2
32.8 [9.61]
23.2 [6.80]
2.1
33.2 [9.73]
28.4 [8.32]
2.2
32.5 [9.52]
26.9 [7.88]
2.1
31.7 [9.29]
25.3 [7.41]
2.1
90
[32.2]
Total BTUH [kW]
Sens BTUH [kW]
Power
35.7 [10.46]
21.4 [6.27]
2.3
34.9 [10.23]
20.2 [5.92]
2.3
34.2 [10.02]
19.0 [5.57]
2.3
33.3 [9.76]
25.5 [7.47]
2.3
32.6 [9.55]
24.1 [7.06]
2.3
31.9 [9.35]
22.7 [6.65]
2.3
32.2 [9.44]
27.8 [8.15]
2.3
31.5 [9.23]
26.3 [7.71]
2.3
30.8 [9.03]
24.7 [7.24]
2.2
95
[35]
Total BTUH [kW]
Sens BTUH [kW]
Power
34.5 [10.11]
20.6 [6.04]
2.4
33.7 [9.88]
19.5 [5.71]
2.4
33.0 [9.67]
18.3 [5.36]
2.4
32.1 [9.41]
24.7 [7.24]
2.4
31.4 [9.20]
23.3 [6.83]
2.4
30.7 [9.00]
21.9 [6.42]
2.4
31.0 [9.09]
27.0 [7.91]
2.4
30.3 [8.88]
25.5 [7.47]
2.4
29.6 [8.67]
24.0 [7.03]
2.4
100
[37.8]
Total BTUH [kW]
Sens BTUH [kW]
Power
33.2 [9.73]
19.7 [5.77]
2.5
32.4 [9.50]
18.6 [5.45]
2.5
31.7 [9.29]
17.6 [5.16]
2.5
30.8 [9.03]
23.8 [6.98]
2.5
30.1 [8.82]
22.5 [6.59]
2.5
29.4 [8.62]
21.2 [6.21]
2.5
29.6 [8.67]
26.1 [7.65]
2.5
29.0 [8.50]
24.7 [7.24]
2.5
28.3 [8.29]
23.3 [6.83]
2.5
105
[40.6]
Total BTUH [kW]
Sens BTUH [kW]
Power
31.8 [9.32]
18.9 [5.54]
2.7
31.1 [9.11]
17.9 [5.25]
2.6
30.4 [8.91]
16.8 [4.92]
2.6
29.4 [8.62]
23.0 [6.74]
2.7
28.8 [8.44]
21.7 [6.36]
2.6
28.1 [8.24]
20.5 [6.01]
2.6
28.3 [8.29]
25.3 [7.41]
2.6
27.7 [8.12]
23.9 [7.00]
2.6
27.0 [7.91]
22.5 [6.59]
2.6
110
[43.3]
Total BTUH [kW]
Sens BTUH [kW]
Power
30.6 [8.97]
18.3 [5.36]
2.8
29.9 [8.76]
17.3 [5.07]
2.8
29.2 [8.56]
16.3 [4.78]
2.7
28.2 [8.26]
22.3 [6.54]
2.8
27.6 [8.09]
21.1 [6.18]
2.7
26.9 [7.88]
19.9 [5.83]
2.7
27.1 [7.94]
24.7 [7.24]
2.8
26.5 [7.77]
23.3 [6.83]
2.7
25.9 [7.59]
21.9 [6.42]
2.7
115
[46.1]
Total BTUH [kW]
Sens BTUH [kW]
Power
29.6 [8.67]
17.9 [5.25]
2.9
29.0 [8.50]
16.9 [4.95]
2.9
28.3 [8.29]
15.9 [4.66]
2.8
27.2 [7.97]
21.9 [6.42]
2.9
26.6 [7.80]
20.7 [6.07]
2.9
26.0 [7.62]
19.5 [5.71]
2.8
26.1 [7.65]
24.3 [7.12]
2.9
25.5 [7.47]
22.9 [6.71]
2.9
24.9 [7.30]
21.6 [6.33]
2.8
HEATING PERFORMANCE DATA—RQNA-B030
5
[-15]
Total BTUH [kW]
Power
11.8 [3.46]
1.5
11.7 [3.43]
1.5
11.6 [3.40]
1.6
10.7 [3.14]
1.7
10.7 [3.14]
1.8
10.6 [3.11]
1.8
10.1 [2.96]
1.9
10.0 [2.93]
1.9
9.9 [2.90]
2.0
IDB
15
[-9.4]
60°F [15.5°C]
Total BTUH [kW]
Power
15.7 [4.60]
1.6
70°F [21.1°C]
15.6 [4.57]
1.6
15.4 [4.51]
1.6
80°F [26.7°C]
14.7 [4.31]
1.8
14.5 [4.25]
1.8
CFM [L/s]
14.4 [4.22]
1.9
14.0 [4.10]
2.0
1180 [557] 1050 [496] 920 [434] 1180 [557] 1050 [496] 920 [434] 1180 [557] 1050 [496] 920 [434]
13.8 [4.04]
2.0
13.7 [4.02]
2.1
O
U
T
D
O
O
R
D
R
Y
B
U
L
B
T
E
M
P
E
R
A
T
U
R
E
°F
[°C]
0
[-17.8]
Total BTUH [kW]
Power
9.7 [2.84]
1.5
9.7 [2.84]
1.5
9.6 [2.81]
1.5
8.7 [2.55]
1.7
8.6 [2.52]
1.7
8.5 [2.49]
1.8
8.0 [2.34]
1.9
7.9 [2.32]
1.9
7.8 [2.29]
1.9
10
[-12.2]
Total BTUH [kW]
Power
13.8 [4.04]
1.5
13.7 [4.02]
1.6
13.6 [3.99]
1.6
12.7 [3.72]
1.8
12.6 [3.69]
1.8
12.5 [3.66]
1.8
12.0 [3.52]
2.0
11.9 [3.49]
2.0
11.8 [3.46]
2.0
25
[-3.9]
Total BTUH [kW]
Power
19.5 [5.71]
1.7
19.4 [5.69]
1.7
19.2 [5.63]
1.7
18.5 [5.42]
1.9
18.3 [5.36]
1.9
18.1 [5.30]
2.0
17.8 [5.22]
2.1
17.6 [5.16]
2.1
17.5 [5.13]
2.1
35
[1.7]
Total BTUH [kW]
Power
23.6 [6.92]
1.7
23.4 [6.86]
1.8
23.2 [6.80]
1.8
22.5 [6.59]
2.0
22.3 [6.54]
2.0
22.1 [6.48]
2.0
21.8 [6.39]
2.1
21.6 [6.33]
2.2
21.4 [6.27]
2.2
20
[-6.7]
Total BTUH [kW]
Power
17.6 [5.16]
1.6
17.5 [5.13]
1.6
17.3 [5.07]
1.7
16.6 [4.86]
1.9
16.4 [4.81]
1.9
16.3 [4.78]
1.9
15.9 [4.66]
2.0
15.7 [4.60]
2.1
15.6 [4.57]
2.1
30
[-1.1]
Total BTUH [kW]
Power
21.5 [6.30]
1.7
21.3 [6.24]
1.7
21.1 [6.18]
1.7
20.4 [5.98]
1.9
20.3 [5.95]
2.0
20.1 [5.89]
2.0
19.8 [5.80]
2.1
19.6 [5.74]
2.1
19.4 [5.69]
2.2
40
[4.4]
Total BTUH [kW]
Power
25.8 [7.56]
1.8
25.5 [7.47]
1.8
25.3 [7.41]
1.8
24.7 [7.24]
2.0
24.5 [7.18]
2.0
24.3 [7.12]
2.1
24.0 [7.03]
2.2
23.8 [6.98]
2.2
23.6 [6.92]
2.2
50
[10]
Total BTUH [kW]
Power
30.7 [9.00]
1.8
30.4 [8.91]
1.9
30.2 [8.85]
1.9
29.6 [8.67]
2.1
29.4 [8.62]
2.1
29.1 [8.53]
2.1
28.9 [8.47]
2.3
28.7 [8.41]
2.3
28.4 [8.32]
2.3
45
[7.2]
Total BTUH [kW]
Power
28.1 [8.24]
1.8
27.9 [8.18]
1.8
27.6 [8.09]
1.9
27.1 [7.94]
2.0
26.8 [7.85]
2.1
26.6 [7.80]
2.1
26.4 [7.74]
2.2
26.1 [7.65]
2.3
25.9 [7.59]
2.3
IDB—Indoor air dry bulb [ ] Designates Metric Conversions
NOTES:
➀When the entering air dry bulb is other than 80°F [27°C], adjust the sensible
capacity from the table by adding [1.10 x CFM x (1 – DR) x (dbE – 80)].
DR —Depression ratio
dbE —Entering air dry bulb
wbE—Entering air wet bulb
Total —Total capacity x 1000 BTUH
Sens —Sensible capacity x 1000 BTUH
Power—KW input
SYSTEMS PERFORMANCE—RQNA-B SERIES

12
SYSTEMS PERFORMANCE—RQNA-B SERIES
COOLING PERFORMANCE DATA—RQNA-B036
ENTERING INDOOR AIR @ 80°F [26.7°C] dbE ➀
wbE 71°F [21.7°C] 67°F [19.4°C] 63°F [17.2°C]
CFM [L/s] 1350 [637] 1200 [566] 1050 [496] 1350 [637] 1200 [566] 1050 [496] 1350 [637] 1200 [566] 1050 [496]
DR ➀.19 .16 .11 .19 .16 .11 .19 .16 .11
O
U
T
D
O
O
R
D
R
Y
B
U
L
B
T
E
M
P
E
R
A
T
U
R
E
°F
[°C]
75
[23.9]
Total BTUH [kW]
Sens BTUH [kW]
Power
46.3 [13.57]
26.6 [7.80]
2.4
45.3 [13.28]
25.1 [7.36]
2.4
44.3 [12.98]
23.7 [6.95]
2.4
43.0 [12.60]
31.7 [9.29]
2.4
42.1 [12.34]
29.9 [8.76]
2.4
41.1 [12.05]
28.2 [8.26]
2.3
41.4 [12.13]
33.4 [9.79]
2.4
40.4 [11.84]
31.5 [9.23]
2.4
39.5 [11.58]
29.7 [8.70]
2.4
80
[26.7]
Total BTUH [kW]
Sens BTUH [kW]
Power
45.2 [13.25]
25.8 [7.56]
2.6
44.2 [12.95]
24.4 [7.15]
2.5
43.2 [12.66]
22.9 [6.71]
2.5
41.9 [12.28]
30.9 [9.06]
2.5
41.0 [12.02]
29.2 [8.56]
2.5
40.1 [11.75]
27.5 [8.06]
2.5
40.3 [11.81]
32.6 [9.55]
2.5
39.4 [11.55]
30.8 [9.03]
2.5
38.5 [11.28]
29.0 [8.50]
2.5
85
[29.4]
Total BTUH [kW]
Sens BTUH [kW]
Power
43.9 [12.87]
25.1 [7.36]
2.7
42.9 [12.57]
23.8 [6.98]
2.6
41.9 [12.28]
22.4 [6.56]
2.6
40.6 [11.90]
30.2 [8.85]
2.6
39.7 [11.63]
28.5 [8.35]
2.6
38.8 [11.37]
26.9 [7.88]
2.6
38.9 [11.40]
31.9 [9.35]
2.7
38.0 [11.14]
30.2 [8.85]
2.6
37.2 [10.90]
28.4 [8.32]
2.6
90
[32.2]
Total BTUH [kW]
Sens BTUH [kW]
Power
42.4 [12.43]
24.6 [7.21]
2.8
41.4 [12.13]
23.3 [6.83]
2.8
40.5 [11.87]
21.9 [6.42]
2.7
39.1 [11.46]
29.7 [8.70]
2.8
38.2 [11.20]
28.0 [8.21]
2.7
37.3 [10.93]
26.4 [7.74]
2.7
37.4 [10.96]
31.4 [9.20]
2.8
36.6 [10.73]
29.7 [8.70]
2.7
35.7 [10.46]
27.9 [8.18]
2.7
95
[35]
Total BTUH [kW]
Sens BTUH [kW]
Power
40.8 [11.96]
24.1 [7.06]
2.9
39.9 [11.69]
22.8 [6.68]
2.9
39.0 [11.43]
21.5 [6.30]
2.9
37.5 [10.99]
29.2 [8.56]
2.9
36.7 [10.76]
27.6 [8.09]
2.8
35.8 [10.49]
26.0 [7.62]
2.8
35.8 [10.49]
30.9 [9.06]
2.9
35.0 [10.26]
29.2 [8.56]
2.9
34.2 [10.02]
27.5 [8.06]
2.8
100
[37.8]
Total BTUH [kW]
Sens BTUH [kW]
Power
39.3 [11.52]
23.6 [6.92]
3.0
38.4 [11.25]
22.3 [6.54]
3.0
37.5 [10.99]
21.0 [6.15]
3.0
36.0 [10.55]
28.7 [8.41]
3.0
35.2 [10.32]
27.1 [7.94]
3.0
34.4 [10.08]
25.5 [7.47]
2.9
34.3 [10.05]
30.4 [8.91]
3.0
33.5 [9.82]
28.7 [8.41]
3.0
32.8 [9.61]
27.0 [7.91]
2.9
105
[40.6]
Total BTUH [kW]
Sens BTUH [kW]
Power
37.8 [11.08]
23.0 [6.74]
3.2
37.0 [10.84]
21.7 [6.36]
3.1
36.2 [10.61]
20.5 [6.01]
3.1
34.5 [10.11]
28.1 [8.24]
3.1
33.8 [9.91]
26.5 [7.77]
3.1
33.0 [9.67]
25.0 [7.33]
3.0
32.9 [9.64]
29.8 [8.73]
3.1
32.1 [9.41]
28.1 [8.24]
3.1
31.4 [9.20]
26.5 [7.77]
3.1
110
[43.3]
Total BTUH [kW]
Sens BTUH [kW]
Power
36.6 [10.73]
22.2 [6.51]
3.3
35.8 [10.49]
21.0 [6.15]
3.2
35.0 [10.26]
19.8 [5.80]
3.2
33.3 [9.76]
27.3 [8.00]
3.2
32.6 [9.55]
25.8 [7.56]
3.2
31.8 [9.32]
24.3 [7.12]
3.2
31.6 [9.26]
29.0 [8.50]
3.3
30.9 [9.06]
27.4 [8.03]
3.2
30.2 [8.85]
25.8 [7.56]
3.2
115
[46.1]
Total BTUH [kW]
Sens BTUH [kW]
Power
35.7 [10.46]
21.3 [6.24]
3.4
34.9 [10.23]
20.1 [5.89]
3.4
34.1 [9.99]
18.9 [5.54]
3.3
32.4 [9.50]
26.3 [7.71]
3.4
31.7 [9.29]
24.9 [7.30]
3.3
30.9 [9.06]
23.4 [6.86]
3.3
30.7 [9.00]
28.0 [8.21]
3.4
30.0 [8.79]
26.5 [7.77]
3.3
29.3 [8.59]
25.0 [7.33]
3.3
HEATING PERFORMANCE DATA—RQNA-B036
5
[-15]
Total BTUH [kW]
Power
15.8 [4.63]
1.8
15.7 [4.60]
1.9
15.5 [4.54]
1.9
14.9 [4.37]
2.1
14.8 [4.34]
2.1
14.7 [4.31]
2.2
14.1 [4.13]
2.4
14.0 [4.10]
2.4
13.8 [4.04]
2.4
IDB
15
[-9.4]
60°F [15.5°C]
Total BTUH [kW]
Power
19.4 [5.69]
1.9
70°F [21.1°C]
19.2 [5.63]
2.0
19.1 [5.60]
2.0
80°F [26.7°C]
18.5 [5.42]
2.2
18.3 [5.36]
2.2
CFM [L/s]
18.2 [5.33]
2.3
17.7 [5.19]
2.5
1350 [637] 1200 [566] 1050 [496] 1350 [637] 1200 [566] 1050 [496] 1350 [637] 1200 [566] 1050 [496]
17.5 [5.13]
2.5
17.3 [5.07]
2.5
O
U
T
D
O
O
R
D
R
Y
B
U
L
B
T
E
M
P
E
R
A
T
U
R
E
°F
[°C]
0
[-17.8]
Total BTUH [kW]
Power
13.9 [4.07]
1.8
13.8 [4.04]
1.8
13.6 [3.99]
1.8
13.0 [3.81]
2.0
12.9 [3.78]
2.1
12.7 [3.72]
2.1
12.1 [3.55]
2.3
12.0 [3.52]
2.4
11.9 [3.49]
2.4
10
[-12.2]
Total BTUH [kW]
Power
17.6 [5.16]
1.9
17.5 [5.13]
1.9
17.3 [5.07]
1.9
16.7 [4.89]
2.1
16.6 [4.86]
2.2
16.4 [4.81]
2.2
15.9 [4.66]
2.4
15.8 [4.63]
2.5
15.6 [4.57]
2.5
25
[-3.9]
Total BTUH [kW]
Power
23.0 [6.74]
2.0
22.8 [6.68]
2.1
22.6 [6.62]
2.1
22.1 [6.48]
2.3
21.9 [6.42]
2.3
21.7 [6.36]
2.4
21.3 [6.24]
2.6
21.1 [6.18]
2.6
20.9 [6.13]
2.6
35
[1.7]
Total BTUH [kW]
Power
27.3 [8.00]
2.1
27.1 [7.94]
2.2
26.8 [7.85]
2.2
26.4 [7.74]
2.4
26.2 [7.68]
2.4
25.9 [7.59]
2.5
25.6 [7.50]
2.7
25.3 [7.41]
2.7
25.1 [7.36]
2.7
20
[-6.7]
Total BTUH [kW]
Power
21.2 [6.21]
2.0
21.0 [6.15]
2.0
20.8 [6.10]
2.0
20.3 [5.95]
2.2
20.1 [5.89]
2.3
19.9 [5.83]
2.3
19.4 [5.69]
2.5
19.3 [5.66]
2.6
19.1 [5.60]
2.6
30
[-1.1]
Total BTUH [kW]
Power
25.1 [7.36]
2.1
24.8 [7.27]
2.1
24.6 [7.21]
2.1
24.1 [7.06]
2.3
23.9 [7.00]
2.4
23.7 [6.95]
2.4
23.3 [6.83]
2.6
23.1 [6.77]
2.6
22.9 [6.71]
2.7
40
[4.4]
Total BTUH [kW]
Power
29.9 [8.76]
2.2
29.6 [8.67]
2.2
29.4 [8.62]
2.2
29.0 [8.50]
2.4
28.7 [8.41]
2.5
28.5 [8.35]
2.5
28.1 [8.24]
2.7
27.9 [8.18]
2.7
27.6 [8.09]
2.8
50
[10]
Total BTUH [kW]
Power
36.3 [10.64]
2.3
35.9 [10.52]
2.3
35.6 [10.43]
2.3
35.4 [10.37]
2.5
35.0 [10.26]
2.6
34.7 [10.17]
2.6
34.5 [10.11]
2.8
34.2 [10.02]
2.8
33.9 [9.94]
2.9
45
[7.2]
Total BTUH [kW]
Power
32.8 [9.61]
2.2
32.6 [9.55]
2.3
32.3 [9.47]
2.3
31.9 [9.35]
2.5
31.7 [9.29]
2.5
31.4 [9.20]
2.6
31.1 [9.11]
2.8
30.8 [9.03]
2.8
30.6 [8.97]
2.8
IDB—Indoor air dry bulb [ ] Designates Metric Conversions
NOTES:
➀When the entering air dry bulb is other than 80°F [27°C], adjust the sensible
capacity from the table by adding [1.10 x CFM x (1 – DR) x (dbE – 80)].
DR —Depression ratio
dbE —Entering air dry bulb
wbE—Entering air wet bulb
Total —Total capacity x 1000 BTUH
Sens —Sensible capacity x 1000 BTUH
Power—KW input

13
SYSTEMS PERFORMANCE—RQNA-B SERIES
COOLING PERFORMANCE DATA—RQNA-B042
5
[-15]
Total BTUH [kW]
Power
18.0 [5.28]
2.3
17.8 [5.22]
2.3
17.7 [5.19]
2.3
16.4 [4.81]
2.6
16.3 [4.78]
2.6
16.1 [4.72]
2.7
15.4 [4.51]
2.9
15.2 [4.45]
2.9
15.1 [4.43]
3.0
IDB
15
[-9.4]
60°F [15.5°C]
Total BTUH [kW]
Power
22.9 [6.71]
2.4
70°F [21.1°C]
22.7 [6.65]
2.4
22.5 [6.59]
2.4
80°F [26.7°C]
21.3 [6.24]
2.7
21.1 [6.18]
2.7
CFM [L/s]
20.9 [6.13]
2.8
20.3 [5.95]
3.0
1580 [746] 1400 [661] 1220 [576] 1580 [746] 1400 [661] 1220 [576] 1580 [746] 1400 [661] 1220 [576]
20.1 [5.89]
3.0
19.9 [5.83]
3.1
O
U
T
D
O
O
R
D
R
Y
B
U
L
B
T
E
M
P
E
R
A
T
U
R
E
°F
[°C]
0
[-17.8]
Total BTUH [kW]
Power
16.0 [4.69]
2.2
15.8 [4.63]
2.2
15.7 [4.60]
2.3
14.4 [4.22]
2.5
14.3 [4.19]
2.6
14.2 [4.16]
2.6
13.4 [3.93]
2.8
13.3 [3.90]
2.9
13.1 [3.84]
2.9
10
[-12.2]
Total BTUH [kW]
Power
20.3 [5.95]
2.3
20.1 [5.89]
2.4
20.0 [5.86]
2.4
18.7 [5.48]
2.6
18.6 [5.45]
2.7
18.4 [5.39]
2.7
17.7 [5.19]
2.9
17.6 [5.16]
3.0
17.4 [5.10]
3.0
25
[-3.9]
Total BTUH [kW]
Power
28.5 [8.35]
2.5
28.2 [8.26]
2.5
28.0 [8.21]
2.6
26.9 [7.88]
2.8
26.7 [7.83]
2.8
26.4 [7.74]
2.9
25.9 [7.59]
3.1
25.7 [7.53]
3.1
25.4 [7.44]
3.2
35
[1.7]
Total BTUH [kW]
Power
34.2 [10.02]
2.6
33.9 [9.94]
2.6
33.6 [9.85]
2.7
32.6 [9.55]
2.9
32.4 [9.50]
2.9
32.1 [9.41]
3.0
31.6 [9.26]
3.2
31.3 [9.17]
3.3
31.1 [9.11]
3.3
20
[-6.7]
Total BTUH [kW]
Power
25.6 [7.50]
2.4
25.4 [7.44]
2.5
25.2 [7.39]
2.5
24.1 [7.06]
2.7
23.8 [6.98]
2.8
23.6 [6.92]
2.8
23.0 [6.74]
3.0
22.8 [6.68]
3.1
22.6 [6.62]
3.1
30
[-1.1]
Total BTUH [kW]
Power
31.4 [9.20]
2.5
31.1 [9.11]
2.6
30.8 [9.03]
2.6
29.8 [8.73]
2.8
29.5 [8.65]
2.9
29.3 [8.59]
2.9
28.8 [8.44]
3.1
28.5 [8.35]
3.2
28.3 [8.29]
3.2
40
[4.4]
Total BTUH [kW]
Power
37.0 [10.84]
2.6
36.6 [10.73]
2.7
36.3 [10.64]
2.7
35.4 [10.37]
2.9
35.1 [10.29]
3.0
34.8 [10.20]
3.0
34.4 [10.08]
3.3
34.1 [9.99]
3.3
33.8 [9.91]
3.4
50
[10]
Total BTUH [kW]
Power
41.8 [12.25]
2.7
41.5 [12.16]
2.8
41.1 [12.05]
2.8
40.3 [11.81]
3.0
39.9 [11.69]
3.1
39.6 [11.61]
3.1
39.2 [11.49]
3.4
38.9 [11.40]
3.4
38.5 [11.28]
3.5
45
[7.2]
Total BTUH [kW]
Power
39.5 [11.58]
2.7
39.2 [11.49]
2.7
38.8 [11.37]
2.8
38.0 [11.14]
3.0
37.6 [11.02]
3.0
37.3 [10.93]
3.1
36.9 [10.81]
3.3
36.6 [10.73]
3.4
36.3 [10.64]
3.4
HEATING PERFORMANCE DATA—RQNA-B042
NOTES:
➀When the entering air dry bulb is other than 80°F [27°C], adjust the sensible
capacity from the table by adding [1.10 x CFM x (1 – DR) x (dbE – 80)].
DR —Depression ratio
dbE —Entering air dry bulb
wbE—Entering air wet bulb
Total —Total capacity x 1000 BTUH
Sens —Sensible capacity x 1000 BTUH
Power—KW input
IDB—Indoor air dry bulb [ ] Designates Metric Conversions
ENTERING INDOOR AIR @ 80°F [26.7°C] dbE ➀
wbE 71°F [21.7°C] 67°F [19.4°C] 63°F [17.2°C]
CFM [L/s] 1580 [746] 1400 [661] 1220 [576] 1580 [746] 1400 [661] 1220 [576] 1580 [746] 1400 [661] 1220 [576]
DR ➀.19 .16 .11 .19 .16 .11 .19 .16 .11
O
U
T
D
O
O
R
D
R
Y
B
U
L
B
T
E
M
P
E
R
A
T
U
R
E
°F
[°C]
75
[23.9]
Total BTUH [kW]
Sens BTUH [kW]
Power
57.5 [16.85]
33.3 [9.76]
3.1
56.2 [16.47]
31.4 [9.20]
3.1
54.9 [16.09]
29.6 [8.67]
3.1
53.3 [15.62]
38.9 [11.40]
3.1
52.1 [15.27]
36.8 [10.79]
3.1
51.0 [14.95]
34.6 [10.14]
3.0
51.4 [15.06]
41.3 [12.10]
3.1
50.3 [14.74]
39.0 [11.43]
3.1
49.2 [14.42]
36.7 [10.76]
3.0
80
[26.7]
Total BTUH [kW]
Sens BTUH [kW]
Power
54.2 [15.88]
31.6 [9.26]
3.3
53.0 [15.53]
29.8 [8.73]
3.2
51.8 [15.18]
28.1 [8.24]
3.2
50.0 [14.65]
37.2 [10.90]
3.2
48.9 [14.33]
35.2 [10.32]
3.2
47.8 [14.01]
33.1 [9.70]
3.2
48.2 [14.13]
39.6 [11.61]
3.2
47.1 [13.80]
37.4 [10.96]
3.2
46.0 [13.48]
35.2 [10.32]
3.2
85
[29.4]
Total BTUH [kW]
Sens BTUH [kW]
Power
52.0 [15.24]
30.4 [8.91]
3.4
50.8 [14.89]
28.7 [8.41]
3.4
49.7 [14.57]
27.0 [7.91]
3.4
47.8 [14.01]
36.1 [10.58]
3.4
46.7 [13.69]
34.1 [9.99]
3.4
45.7 [13.39]
32.1 [9.41]
3.3
45.9 [13.45]
38.4 [11.25]
3.4
44.9 [13.16]
36.3 [10.64]
3.4
43.9 [12.87]
34.2 [10.02]
3.3
90
[32.2]
Total BTUH [kW]
Sens BTUH [kW]
Power
50.5 [14.80]
29.6 [8.67]
3.6
49.4 [14.48]
27.9 [8.18]
3.6
48.3 [14.16]
26.3 [7.71]
3.5
46.4 [13.60]
35.2 [10.32]
3.6
45.3 [13.28]
33.3 [9.76]
3.5
44.3 [12.98]
31.3 [9.17]
3.5
44.5 [13.04]
37.6 [11.02]
3.6
43.5 [12.75]
35.5 [10.40]
3.5
42.5 [12.46]
33.4 [9.79]
3.5
95
[35]
Total BTUH [kW]
Sens BTUH [kW]
Power
49.6 [14.54]
29.0 [8.50]
3.7
48.5 [14.21]
27.4 [8.03]
3.7
47.4 [13.89]
25.8 [7.56]
3.7
45.5 [13.33]
34.7 [10.17]
3.7
44.5 [13.04]
32.8 [9.61]
3.7
43.5 [12.75]
30.9 [9.06]
3.6
43.6 [12.78]
37.0 [10.84]
3.7
42.6 [12.48]
35.0 [10.26]
3.7
41.7 [12.22]
32.9 [9.64]
3.6
100
[37.8]
Total BTUH [kW]
Sens BTUH [kW]
Power
49.0 [14.36]
28.6 [8.38]
3.9
47.9 [14.04]
27.0 [7.91]
3.9
46.8 [13.72]
25.5 [7.47]
3.8
44.8 [13.13]
34.3 [10.05]
3.9
43.8 [12.84]
32.4 [9.50]
3.8
42.8 [12.54]
30.5 [8.94]
3.8
42.9 [12.57]
36.6 [10.73]
3.9
42.0 [12.31]
34.6 [10.14]
3.8
41.0 [12.02]
32.6 [9.55]
3.8
105
[40.6]
Total BTUH [kW]
Sens BTUH [kW]
Power
48.3 [14.16]
28.3 [8.29]
4.1
47.2 [13.83]
26.7 [7.83]
4.0
46.1 [13.51]
25.1 [7.36]
4.0
44.1 [12.92]
33.9 [9.94]
4.0
43.2 [12.66]
32.0 [9.38]
4.0
42.2 [12.37]
30.2 [8.85]
3.9
42.3 [12.40]
36.3 [10.64]
4.0
41.3 [12.10]
34.3 [10.05]
4.0
40.4 [11.84]
32.3 [9.47]
3.9
110
[43.3]
Total BTUH [kW]
Sens BTUH [kW]
Power
47.3 [13.86]
27.8 [8.15]
4.2
46.3 [13.57]
26.3 [7.71]
4.2
45.2 [13.25]
24.8 [7.27]
4.1
43.2 [12.66]
33.5 [9.82]
4.2
42.2 [12.37]
31.7 [9.29]
4.1
41.2 [12.07]
29.8 [8.73]
4.1
41.3 [12.10]
35.8 [10.49]
4.2
40.4 [11.84]
33.9 [9.94]
4.1
39.5 [11.58]
31.9 [9.35]
4.1
115
[46.1]
Total BTUH [kW]
Sens BTUH [kW]
Power
45.8 [13.42]
27.2 [7.97]
4.4
44.8 [13.13]
25.7 [7.53]
4.3
43.7 [12.81]
24.2 [7.09]
4.3
41.6 [12.19]
32.9 [9.64]
4.3
40.7 [11.93]
31.1 [9.11]
4.3
39.8 [11.66]
29.3 [8.59]
4.2
39.7 [11.63]
35.3 [10.35]
4.3
38.9 [11.40]
33.3 [9.76]
4.3
38.0 [11.14]
31.4 [9.20]
4.2

14
SYSTEMS PERFORMANCE—RQNA-B SERIES
COOLING PERFORMANCE DATA—RQNA-B048
5
[-15]
Total BTUH [kW]
Power
18.3 [5.36]
2.6
18.1 [5.30]
2.7
17.9 [5.25]
2.7
17.5 [5.13]
3.1
17.3 [5.07]
3.1
17.2 [5.04]
3.2
16.6 [4.86]
3.4
16.5 [4.84]
3.5
16.3 [4.78]
3.5
IDB
15
[-9.4]
60°F [15.5°C]
Total BTUH [kW]
Power
25.5 [7.47]
2.7
70°F [21.1°C]
25.3 [7.41]
2.8
25.0 [7.33]
2.8
80°F [26.7°C]
24.7 [7.24]
3.2
24.5 [7.18]
3.3
CFM [L/s]
24.3 [7.12]
3.3
23.9 [7.00]
3.5
1800 [850] 1600 [755] 1400 [661] 1800 [850] 1600 [755] 1400 [661] 1800 [850] 1600 [755] 1400 [661]
23.6 [6.92]
3.6
23.4 [6.86]
3.7
O
U
T
D
O
O
R
D
R
Y
B
U
L
B
T
E
M
P
E
R
A
T
U
R
E
°F
[°C]
0
[-17.8]
Total BTUH [kW]
Power
15.1 [4.43]
2.6
14.9 [4.37]
2.6
14.8 [4.34]
2.6
14.3 [4.19]
3.0
14.2 [4.16]
3.1
14.1 [4.13]
3.1
13.4 [3.93]
3.4
13.3 [3.90]
3.4
13.2 [3.87]
3.5
10
[-12.2]
Total BTUH [kW]
Power
21.8 [6.39]
2.7
21.6 [6.33]
2.7
21.4 [6.27]
2.8
21.0 [6.15]
3.1
20.8 [6.10]
3.2
20.6 [6.04]
3.2
20.1 [5.89]
3.5
20.0 [5.86]
3.5
19.8 [5.80]
3.6
25
[-3.9]
Total BTUH [kW]
Power
33.0 [9.67]
2.9
32.7 [9.58]
2.9
32.4 [9.50]
3.0
32.3 [9.47]
3.3
32.0 [9.38]
3.4
31.7 [9.29]
3.4
31.4 [9.20]
3.7
31.1 [9.11]
3.7
30.8 [9.03]
3.8
35
[1.7]
Total BTUH [kW]
Power
39.8 [11.66]
3.0
39.5 [11.58]
3.0
39.1 [11.46]
3.1
39.1 [11.46]
3.5
38.7 [11.34]
3.5
38.4 [11.25]
3.6
38.2 [11.20]
3.8
37.9 [11.11]
3.9
37.5 [10.99]
3.9
20
[-6.7]
Total BTUH [kW]
Power
29.3 [8.59]
2.8
29.0 [8.50]
2.8
28.8 [8.44]
2.9
28.5 [8.35]
3.3
28.3 [8.29]
3.3
28.0 [8.21]
3.4
27.6 [8.09]
3.6
27.4 [8.03]
3.7
27.2 [7.97]
3.7
30
[-1.1]
Total BTUH [kW]
Power
36.6 [10.73]
2.9
36.3 [10.64]
3.0
35.9 [10.52]
3.0
35.8 [10.49]
3.4
35.5 [10.40]
3.4
35.2 [10.32]
3.5
34.9 [10.23]
3.7
34.6 [10.14]
3.8
34.3 [10.05]
3.8
40
[4.4]
Total BTUH [kW]
Power
42.7 [12.51]
3.0
42.3 [12.40]
3.1
41.9 [12.28]
3.1
41.9 [12.28]
3.5
41.5 [12.16]
3.6
41.2 [12.07]
3.6
41.0 [12.02]
3.9
40.7 [11.93]
3.9
40.3 [11.81]
4.0
50
[10]
Total BTUH [kW]
Power
46.5 [13.63]
3.2
46.1 [13.51]
3.2
45.7 [13.39]
3.3
45.8 [13.42]
3.6
45.4 [13.31]
3.7
45.0 [13.19]
3.8
44.9 [13.16]
4.0
44.5 [13.04]
4.0
44.1 [12.92]
4.1
45
[7.2]
Total BTUH [kW]
Power
45.0 [13.19]
3.1
44.6 [13.07]
3.2
44.2 [12.95]
3.2
44.2 [12.95]
3.6
43.8 [12.84]
3.6
43.4 [12.72]
3.7
43.3 [12.69]
3.9
42.9 [12.57]
4.0
42.5 [12.46]
4.0
HEATING PERFORMANCE DATA—RQNA-B048
NOTES:
➀When the entering air dry bulb is other than 80°F [27°C], adjust the sensible
capacity from the table by adding [1.10 x CFM x (1 – DR) x (dbE – 80)].
DR —Depression ratio
dbE —Entering air dry bulb
wbE—Entering air wet bulb
Total —Total capacity x 1000 BTUH
Sens —Sensible capacity x 1000 BTUH
Power—KW input
IDB—Indoor air dry bulb [ ] Designates Metric Conversions
ENTERING INDOOR AIR @ 80°F [26.7°C] dbE ➀
wbE 71°F [21.7°C] 67°F [19.4°C] 63°F [17.2°C]
CFM [L/s] 1800 [850] 1600 [755] 1400 [661] 1800 [850] 1600 [755] 1400 [661] 1800 [850] 1600 [755] 1400 [661]
DR ➀.19 .16 .11 .19 .16 .11 .19 .16 .11
O
U
T
D
O
O
R
D
R
Y
B
U
L
B
T
E
M
P
E
R
A
T
U
R
E
°F
[°C]
75
[23.9]
Total BTUH [kW]
Sens BTUH [kW]
Power
61.3 [17.97]
36.1 [10.58]
3.4
60.0 [17.58]
34.1 [9.99]
3.3
58.6 [17.17]
32.1 [9.41]
3.3
57.1 [16.73]
42.7 [12.51]
3.3
55.9 [16.38]
40.3 [11.81]
3.3
54.6 [16.00]
38.0 [11.14]
3.2
54.2 [15.88]
44.8 [13.13]
3.3
53.0 [15.53]
42.3 [12.40]
3.2
51.8 [15.18]
39.9 [11.69]
3.2
80
[26.7]
Total BTUH [kW]
Sens BTUH [kW]
Power
60.0 [17.58]
35.7 [10.46]
3.5
58.7 [17.20]
33.7 [9.88]
3.5
57.3 [16.79]
31.7 [9.29]
3.5
55.8 [16.35]
42.2 [12.37]
3.5
54.6 [16.00]
39.9 [11.69]
3.4
53.3 [15.62]
37.6 [11.02]
3.4
52.9 [15.50]
44.4 [13.01]
3.5
51.7 [15.15]
41.9 [12.28]
3.4
50.5 [14.80]
39.5 [11.58]
3.4
85
[29.4]
Total BTUH [kW]
Sens BTUH [kW]
Power
58.5 [17.14]
35.0 [10.26]
3.7
57.2 [16.76]
33.0 [9.67]
3.7
55.9 [16.38]
31.1 [9.11]
3.6
54.3 [15.91]
41.5 [12.16]
3.7
53.1 [15.56]
39.3 [11.52]
3.6
51.9 [15.21]
37.0 [10.84]
3.6
51.4 [15.06]
43.7 [12.81]
3.6
50.3 [14.74]
41.2 [12.07]
3.6
49.1 [14.39]
38.8 [11.37]
3.6
90
[32.2]
Total BTUH [kW]
Sens BTUH [kW]
Power
56.9 [16.68]
34.1 [9.99]
3.9
55.7 [16.32]
32.2 [9.44]
3.9
54.4 [15.94]
30.3 [8.88]
3.8
52.7 [15.44]
40.7 [11.93]
3.8
51.6 [15.12]
38.4 [11.25]
3.8
50.4 [14.77]
36.2 [10.61]
3.7
49.8 [14.59]
42.8 [12.54]
3.8
48.7 [14.27]
40.4 [11.84]
3.8
47.6 [13.95]
38.1 [11.17]
3.7
95
[35]
Total BTUH [kW]
Sens BTUH [kW]
Power
55.4 [16.24]
33.2 [9.73]
4.1
54.1 [15.86]
31.3 [9.17]
4.0
52.9 [15.50]
29.5 [8.65]
4.0
51.2 [15.01]
39.7 [11.63]
4.0
50.0 [14.65]
37.5 [10.99]
4.0
48.9 [14.33]
35.3 [10.35]
3.9
48.3 [14.16]
41.8 [12.25]
4.0
47.2 [13.83]
39.5 [11.58]
3.9
46.1 [13.51]
37.2 [10.90]
3.9
100
[37.8]
Total BTUH [kW]
Sens BTUH [kW]
Power
53.9 [15.80]
32.2 [9.44]
4.2
52.7 [15.44]
30.4 [8.91]
4.2
51.5 [15.09]
28.7 [8.41]
4.2
49.7 [14.57]
38.8 [11.37]
4.2
48.6 [14.24]
36.6 [10.73]
4.1
47.5 [13.92]
34.5 [10.11]
4.1
46.8 [13.72]
40.9 [11.99]
4.2
45.7 [13.39]
38.6 [11.31]
4.1
44.7 [13.10]
36.4 [10.67]
4.1
105
[40.6]
Total BTUH [kW]
Sens BTUH [kW]
Power
52.5 [15.39]
31.4 [9.20]
4.4
51.3 [15.03]
29.6 [8.67]
4.4
50.2 [14.71]
27.9 [8.18]
4.3
48.3 [14.16]
37.9 [11.11]
4.4
47.2 [13.83]
35.8 [10.49]
4.3
46.2 [13.54]
33.7 [9.88]
4.3
45.4 [13.31]
40.0 [11.72]
4.3
44.4 [13.01]
37.8 [11.08]
4.3
43.4 [12.72]
35.6 [10.43]
4.2
110
[43.3]
Total BTUH [kW]
Sens BTUH [kW]
Power
51.3 [15.03]
30.7 [9.00]
4.6
50.2 [14.71]
29.0 [8.50]
4.5
49.1 [14.39]
27.3 [8.00]
4.5
47.2 [13.83]
37.3 [10.93]
4.5
46.1 [13.51]
35.2 [10.32]
4.5
45.1 [13.22]
33.2 [9.73]
4.4
44.3 [12.98]
39.4 [11.55]
4.5
43.3 [12.69]
37.2 [10.90]
4.5
42.3 [12.40]
35.0 [10.26]
4.4
115
[46.1]
Total BTUH [kW]
Sens BTUH [kW]
Power
50.5 [14.80]
30.3 [8.88]
4.8
49.3 [14.45]
28.7 [8.41]
4.7
48.2 [14.13]
27.0 [7.91]
4.7
46.3 [13.57]
36.9 [10.81]
4.7
45.2 [13.25]
34.9 [10.23]
4.7
44.2 [12.95]
32.8 [9.61]
4.6
43.4 [12.72]
39.0 [11.43]
4.7
42.4 [12.43]
36.9 [10.81]
4.6
41.4 [12.13]
34.7 [10.17]
4.6

15
AIRFLOW PERFORMANCE—RQNA-B SERIES
External Static Pressure—Inches W.C. [kPa]
CFM [L/s] Air Delivery/RPM/Watts—208 Volts Side Discharge—Wet Coil
RPM 730
Nominal
Cooling
Capacity
Tons [kW]
Motor
Speed
from
Factory
775
Manufacturer
Recommended
Air-Flow Range
(Min/Max) CFM
Motor
Speed
820 865 905 940 975
Watts 356 349 341 331 320 305 287
Medium
CFM 1222 [577] 1197 [565] 1179 [556] 1162 [548] 1137 [537] 1097 [518]
0.1 [.02] 0.2 [.05] 0.3 [.07] 0.4 [.10] 0.5 [.12] 0.6 [.15] 0.7 [.17]
1033 [488]
RPM 765 810 855 890
RPM 695 785 870 905 940 980 1020
920 960 995
Watts 221 214 203 191 171 163 149
High
CFM 898 [424] 861 [406] 822 [388] 777 [367] 721 [340] 651 [307] 562 [265]
2.5
[8.79] Low 875 CFM/1125 CFM
[413/531 L/s]
Low
CFM 1076 [508]
RPM 940 965 995 1020 1045 1070 1090
1059 [500] 1032 [487] 996 [470] 950 [448] 896 [423] 832 [393]
Watts 423 415 407 397 386 370 351
High
CFM 1222 [577] 1201 [567] 1173 [554] 1137 [537] 1090 [514] 1030 [486] 954 [450]
RPM 785 805 830 870 905 950 990
Watts 355 352 346 340 331 320 306
RPM 824 856 889 931 968 1009 1041
Watts 268 280 288 303 311 325 331
High
CFM 1559 [736] 1530 [722] 1488 [702] 1454 [686] 1417 [669] 1375 [649] 1336 [631]
RPM 870 893 932 968 1007 1036 1072
3.5
[12.31] Low 1225 CFM/1575 CFM
[578/743 L/s]
Low
CFM 1455 [687] 1431 [675] 1396 [659] 1360 [642] 1315 [621] 1285 [606] 1241 [586]
Watts 321 327 338 351 364 371 381
2.0
[7.03] High 700 CFM/900 CFM
[271/319 L/s]
Low
CFM 675 [319] 657 [310] 634 [299] 602 [284] 560 [264] 505 [238] 435 [205]
Watts 292 278 266 253 239 221 199
RPM 923 944 979 1013 1045 1077 1098
Watts 390 401 412 425 433 440 432
High
CFM 1770 [835] 1751 [826] 1706 [805] 1672 [789] 1624 [766] 1555 [734] 1463 [690]
RPM 966 989 1018 1050 1078 1100 1115
4.0
[14.07] Low 1350 CFM/1700 CFM
[496/802 L/s]
Low
CFM 1675 [791] 1658 [782] 1610 [760] 1580 [746] 1535 [724] 1491 [704] 1422 [671]
Watts 454 466 473 486 490 481 460
Blower Size/
Motor
HP [W] &
# of Speeds
10x9
1/2 HP [372]
2 Speed
Motor
10x9
3/4 HP [559]
2 Speed
Motor
9x7
1/4 HP [186]
2 Speed
Motor
10x9
3/4 HP [559]
2 Speed
Motor
High
CFM 1514 [715] 1461 [690] 1415 [668] 1370 [647] 1322 [624] 1266 [597] 1197 [565]
RPM 895 930 965 985 1005 1025 1045
Watts 538 514 493 473 454 434 412
3.0
[10.55] Low 1050 CFM/1350 CFM
[496/637 L/s]
10x9
1/3 HP [248]
1 Speed
Motor
INDOOR AIRFLOW PERFORMANCE—208 VOLTS
NOTE: Effect of electric heat strip on airflow performance is negligible.
[ ] Designates Metric Conversions

16
AIRFLOW PERFORMANCE—RQNA-B SERIES
External Static Pressure—Inches W.C. [kPa]
CFM [L/s] Air Delivery/RPM/Watts—230 Volts Side Discharge—Wet Coil
RPM 760
Blower Size/
Motor
HP [W] &
# of Speeds
Nominal
Cooling
Capacity
Tons [kW]
10x9
1/2 HP [373]
2 Speed
Motor
Motor
Speed
from
Factory
815
Manufacturer
Recommended
Air-Flow Range
(Min/Max) CFM
Motor
Speed
870 910 950 975 1000
Watts 419 406 394 381 368 353 334
10x9
3/4 HP [559]
2 Speed
Motor
Medium
CFM 1411 [666] 1368 [646] 1327 [626] 1285 [606] 1238 [584] 1183 [558]
0.1 [.02] 0.2 [.05] 0.3 [.07] 0.4 [.10] 0.5 [.12] 0.6 [.15] 0.7 [.17]
1116 [527]
RPM 865 900 935 970
RPM 825 870 910 950 985 1010 1030
1000 1020 1035
3.0
[10.55]
Watts 253 242 230 217 204 189 181
9x7
1/4 HP [186]
2 Speed
Motor
10x9
3/4 HP [559]
2 Speed
Motor
High
High
CFM 946 [446] 922 [435] 882 [416] 830 [392] 769 [363] 701 [331] 630 [297]
2.5
[8.79] Low 875 CFM/1125 CFM
[413/531 L/s]
Low
CFM 1206 [569]
RPM 990 1015 1035 1055 1070 1085 1100
1182 [558] 1157 [546] 1128 [532] 1091 [515] 1044 [493] 983 [464]
Watts 498 498 481 464 447 431 391
1050 CFM/1350 CFM
[496/637 L/s]
10x9
1/3 HP [249]
1 Speed
Motor
High
CFM 1391 [656] 1357 [640] 1312 [619] 1258 [594] 1201 [567] 1145 [540] 1093 [516]
RPM 835 875 915 940 965 985 1000
Watts 428 419 406 392 378 365 355
RPM 831 854 894 932 972 1005 1042
Watts 276 282 297 307 319 326 341
High
CFM 1550 [732] 1520 [717] 1486 [701] 1449 [684] 1407 [664] 1382 [652] 1337 [631]
RPM 867 890 930 974 1003 1039 1073
3.5
[12.31] Low 1225 CFM/1575 CFM
[578/743 L/s]
Low
CFM 1467 [692] 1439 [679] 1408 [665] 1360 [642] 1331 [628] 1287 [607] 1259 [594]
Watts 317 323 339 355 362 377 385
2.0
[7.03] High 700 CFM/900 CFM
[271/319 L/s]
Low
CFM 771 [364] 751 [354] 725 [342] 691 [326] 645 [304] 584 [276] 546 [258]
Watts 315 303 288 273 257 241 226
RPM 931 950 982 1018 1054 1082 1103
Watts 404 409 424 434 450 453 443
High
CFM 1748 [825] 1718 [811] 1686 [796] 1647 [777] 1616 [763] 1543 [728] 1472 [695]
RPM 955 978
High
1010 1043 1073 1096 1111
4.0
[14.07] Low 1350 CFM/1700 CFM
[496/802 L/s]
Low
CFM 1692 [799] 1661 [784] 1633 [771] 1589 [750] 1560 [736] 1512 [714] 1442 [681]
Watts 440 446 462 475 484 473 459
CFM 1641 [774] 1577 [744] 1515 [715] 1455 [687] 1393 [657] 1329 [627] 1262 [596]
RPM 980 1000 1020 1035 1050 1065 1080
Watts 589 565 543 523 503 481 456
INDOOR AIRFLOW PERFORMANCE—230 VOLTS
CFM [L/s] 600 [283] 800 [378] 1000 [472] 1200 [566] 1400 [661]
Pressure Drop—Inches W.C. [kPa] .00 .01 [.002] .02 [.005] .03 [.007] .05 [.012]
1600 [775]
.07 [.017]
DOWN DISCHARGE PRESSURE DROP (ADD TO EXTERNAL STATIC PRESSURE)
[ ] Designates Metric Conversions
NOTE: Effect of electric heat strip on airflow performance is negligible.

ELECTRICAL DATA – RQNA-B SERIES
Minimum Circuit Ampacity 17/17
Unit Information
Unit Operating
Voltage Range 187-253
Minimum Overcurrent
Protection Device Size 20/20
Maximum Overcurrent
Protection Device Size 25/25
Compressor Motor
No. 1
Volts 208/230
Phase 1
HP 2
RPM 3450
Amps (RLA) 10.9/10.9
Amps (LRA) 54/54
Condenser Motor
No. 1
Volts 208/230
Phase 1
HP 1/5
Amps (FLA) 1.3
Amps (LRA) 2.2
Evaporator Fan
No. 1
Volts 208/230
Phase 1
HP 1/4
Amps (FLA) 1.5
Amps (LRA) 2.4 5.1
2.4
1/2
1
208/230
1
2.2
1.3
1/5
1
208/230
1
72.5/72.5
13.5/13.5
3450
2 1/2
1
208/230
1
30/30
25/25
21/21
187-253
2.5
1.7
1/3
1
208/230
1
2.2
1.3
1/5
1
208/230
1
77/77
10.3/10.3
3450
3
3
200/230
1
25/25
20/20
16/16
187-253
2.5
1.7
1/3
1
208/230
1
2.2
1.3
1/5
1
208/230
1
88/88
16/16
3450
3
1
208/230
1
35/35
30/30
24/24
187-253
0
6.8
3/4
1
208/230
1
3.9
2
1/3
1
208/230
1
88/88
12.4/12.4
3450
3 1/2
3
200/230
1
35/35
30/30
25/25
187-253
0
6.8
3/4
1
208/230
1
3.9
2
1/3
1
208/230
1
95/95
17.9/17.9
3450
3 1/2
1
208/230
1
45/45
40/40
32/32
187-253
0
6.8
3/4
1
208/230
1
3.9
2
1/3
1
208/230
1
88/88
12.4/12.4
3450
4
3
200/230
1
35/35
30/30
25/25
187-253
0
6.8
3/4
1
208/230
1
3.9
2
1/3
1
208/230
1
137/137
22/22
3450
4
1
208/230
1
50/50
45/45
37/37
187-253
-B024JK -B030JK -B036CK -B036JK -B042CK -B042JK -B048CK -B048JK
17
ELECTRICAL DATA—RQNA-B SERIES
1. Horsepower Per Compressor.
2. Amp Draw Per Motor. Multiply Value By Number of Motors to Determine Total Amps.

Unit Model Application Electric Heater Kit Models
RXQJ-A10J (208-240 volt, 1-ph, 10kW)
RXQJ-A05J (208-240 volt, 1-ph, 5kW)
RXQJ-A05J (208-240 volt, 1-ph, 5kW)
RXQJ-A15J (208-240 volt, 1-ph, 15kW)
RXQJ-A10J (208-240 volt, 1-ph, 10kW)
RXQJ-A10J (208-240 volt, 1-ph, 10kW)
RXQJ-B10J (208-240 volt, 1-ph, 10kW)
RXQJ-B15J (208-240 volt, 1-ph, 15kW)
RQNA-B036CK
RXQJ-B10J (208-240 volt, 1-ph, 10kW)
RXQJ-B15J (208-240 volt, 1-ph, 15kW)
RXQJ-A10C (208-240 volt, 3-ph, 10kW)
RXQJ-A15C (208-240 volt, 3-ph, 15kW)
RXQJ-A10C (208-240 volt, 3-ph, 10kW)
RQNA-B048CK
RXQJ-A15C (208-240 volt, 3-ph, 15kW)
RXQJ-A10C (208-240 volt, 3-ph, 10kW)
RXQJ-A15C (208-240 volt, 3-ph, 15kW)
RQNA-B042CK
RQNA-B024JK
RQNA-B030JK
RQNA-B036JK
RQNA-B042JK
RQNA-B048JK
WARNING
ONLY ELECTRIC HEATER KITS SUPPLIED BY THIS MANU-
FACTURER AS DESCRIBED IN THIS PUBLICATION HAVE
BEEN DESIGNED, TESTED, AND EVALUATED BY A NATION-
ALLY RECOGNIZED SAFETY TESTING AGENCY FOR USE
WITH THIS UNIT. USE OF ANY OTHER MANUFACTURED
ELECTRIC HEATERS INSTALLED WITHIN THIS UNIT MAY
CAUSE HAZARDOUS CONDITIONS RESULTING IN PROP-
ERTY DAMAGE, FIRE, BODILY INJURY OR DEATH.
18
ELECTRIC HEATER KITS—RQNA-B SERIES

19
ELECTRIC HEATER KITS—RQNA-B SERIES
B024JK
No Heat — — — 17/17 20/25 20/25
A10J 2 24.56/32.75 34.6/40.0 60/67 60/60 70/70
A05J 1 12.28/16.38 17.3/20.0 39/42 40/40 45/45
44/50 45/50 — — —
— — 17/17 20/25 20/25
22/25 25/25 — — —
RXQJ-
Heater Kit
Nominal kW
No. of
Elements
Heater
KBTU/Hr
@ 208-240 V
Heater
Amp.
@ 208-240 V
Unit Min. Ckt.
Ampacity
@ 208-240 V
Over Current
Protective Device Size
Min./Max.
@ 208 V
Min./Max.
@ 240 V
Min. Ckt.
Ampacity
208/240V
Max. Fuse
Size
208/240V
Min. Circuit
Ampacity
208-240 V
Over Current
Protective Device Size
Min./Max.
@ 208 V
Min./Max.
@ 240 V
7.2/9.6
—
3.6/4.8
Rated
Heater kW
@ 208-240 V
2
—
1
No. of
Sequence
Steps
208-240 VOLT, SINGLE PHASE, 60 HZ, AUXILIARY ELECTRIC HEATER KITS CHARACTERISTICS AND APPLICATION
B030JK
No Heat — — — — 21/21 25/30 25/30 — — 21/21 25/30 25/30
A05J 1 1 3.6/4.8 12.28/16.38 17.3/20.0 43/46 45/50 50/50 22/25 25/25 — — —
A10J 2 2 7.2/9.6 24.56/32.75 34.6/40.0 64/71 70/70 80/80 44/50 45/50 — — —
B036JK
No Heat — — — — 24/24 30/35 30/35 — — 24/24 30/35 30/35
A10J 2 2 7.2/9.6 24.56/32.75 34.6/40.0 67/74 70/70 80/80 44/50 45/50 — — —
A15J 3 2 10.8/14.4 36.84/49.13 51.9/60.0 88/99 90/90 100/100 65/75 70/80 — — —
B042JK
No Heat — — — — 31/31 35/45 35/45 — — 31/31 35/45 35/45
B10J 2 2 7.2/9.6 24.56/32.75 34.6/40.0 74/81 80/80 90/90 44/50 45/50 — — —
B15J 3 2 10.8/14.4 36.84/49.13 51.9/60.0 96/106 100/100 110/110 65/75 70/80 — — —
B048JK
No Heat — — — — 36/36 45/50 45/50 — — 36/36 45/50 45/50
B10J 2 2 7.2/9.6 24.56/32.75 34.6/40.0 79/86 80/90 90/90 44/50 45/50 — — —
B15J 3 2 10.8/14.4 36.84/49.13 51.9/60.0 101/111 110/110 125/125 65/75 70/80 — — —
Heater Kit Heat Pump
Unit
Model
No.
RQNA-
Heater Kit Heat Pump
Single Power Supply For Both Unit and Heater Kit Separate Power Supply For Both Unit and Heater Kit
10.8/14.4A15C 3 36.84/49.13 30.1/34.7 54/60 60/60
208-240 VOLT, THREE PHASE, 60 HZ, AUXILIARY ELECTRIC HEATER KITS CHARACTERISTICS AND APPLICATION
—
7.2/9.6
60/60
B042CK
No Heat — — — — 24/24 30/35 30/35 — — 24/24 30/35 30/35
A10C 3 3 7.2/9.6 24.56/32.75 20.0/23.1 49/53 50/50 60/60 25/29 25/30 — — —
A15C 3
B036CK
No Heat
3 10.8/14.4
— — 16/16 20/25 20/25
36.84/49.13 30.1/34.7 62/67
A10C
70/70 70/70
3 24.56/32.75 20.0/23.1 41/45 45/45 45/45
38/44 40/45 — — —
B048CK
No Heat — — — — 26/26 30/35 30/35 — — 26/26 30/35 30/35
A10C 3 3 7.2/9.6 24.56/32.75 20.0/23.1 51/55 60/60 60/60 25/29 25/30 — — —
A15C 3 3 10.8/14.4 36.84/49.13 30.1/34.7 63/69 70/70 70/70 38/44 40/45 — —
Rated
Heater kW
@ 208-240 V
3
—
—
3
Heater Kit Heat Pump
Unit
Model
No.
RQNA-
Heater Kit Heat Pump
Single Power Supply For Both Unit and Heater Kit Separate Power Supply For Both Unit and Heater Kit
No. of
Sequence
Steps
38/44 40/45 — — —
— — 16/16 20/25 20/25
25/29 25/30 — — —
RXQJ-
Heater Kit
Nominal kW
No. of
Elements
Heater
KBTU/Hr
@ 208-240 V
Heater
Amp.
@ 208-240 V
Unit Min. Ckt.
Ampacity
@ 208-240 V
Over Current
Protective Device Size
Min./Max.
@ 208 V
Min./Max.
@ 240 V
Min. Ckt.
Ampacity
208/240V
Max. Fuse
Size
208/240V
Min. Circuit
Ampacity
208-240 V
Over Current
Protective Device Size
Min./Max.
@ 208 V
Min./Max.
@ 240 V

30% 2%
21% 2%
29% 2%
20% 2%
CORNER WEIGHTS
% OF TOTAL
UNIT WEIGHT
THERMOSTAT WIRING
ENTRANCE
ELECTRICAL POWER
ENTRANCE
BLOWER/
EVAPORATOR
ACCESS PANEL
SIDE SUPPLY
DUCT OPENING
SIDE RETURN
DUCT OPENING
UNIT DIMENSIONS
SELF-CONTAINED
AIR CONDITIONERS
OUTDOOR FAN GRILLE
AND COMPRESSOR ACCESS
CONTROL
ACCESS PANEL
LIQUID PRESSURE
SERVICE PORT
SUCTION PRESSURE
SERVICE PORT
THREADED PVC CONDENSATE
DRAIN CONNECTION (3/4
"
[19.05 mm] N.P.T.)
OUTDOOR COIL
PROTECTIVE GRILLE
FILTER ACCESS
PANEL (FOR
UNIT MOUNTED
FILTER ACCESSORY)
OUTDOOR FAN
GRILLE &
COMPRESSOR ACCESS
BOTTOM
RETURN
DUCT
OPENING
BOTTOM
SUPPLY
DUCT
OPENING
4719/32
"
[1209 mm]
5013/16
"
[1290 mm]
451/16
"
[1145 mm]
INSIDE 13/16
"
[30 mm]
TYP.
11/2
"
[38 mm]
TYP.
497/16
"
[1256 mm]
INSIDE
199/16
"
[497 mm]
153/8
"
[391 mm]
33/16
"
[97 mm]
45/16
"
[95 mm]
313/16
"
[97 mm]
141/4
"
[362 mm]
TYP.
[ ] Designates Metric Conversions[ ] Designates Metric Conversions
20
UNIT DIMENSIONS—RQNA-B SERIES
TOP VIEW BOTTOM VIEW
This manual suits for next models
7
Table of contents
Other Ruud Heat Pump manuals
Popular Heat Pump manuals by other brands

Aqua
Aqua PH Series Installation and instruction manual

CIAT
CIAT HCompact2 HA Series Installation, Operation, Commissioning, Maintenance

Lennox
Lennox SunSource brochure

Panasonic
Panasonic WH-SDC12H9E8 Service manual

Hisense
Hisense Hi-Therma Series Service handbook

Daikin
Daikin Altherma 3 H HT W Installer's reference guide

T.I.P.
T.I.P. STEAM 25000 Translation of original operating instructions

Lennox
Lennox VPB H4-3P Series Installation & operation instructions

Samsung
Samsung AM BXVGFH/AA Series Technical data book

Carrier
Carrier OG-HPR410GEN-03 owner's manual

Riello
Riello VegA RMXA Series installation instructions

Carrier
Carrier 25hba installation instructions