Output Cable Connection
1, Every welding machine has been disposed a pair of mobile plugs another end of pincer
cable is connected to black mobile plug and another grounding cable pincer is connected to
red mobile plug. Furthermore, they must be tightened by spanner. Make sure secindary
cables(holder and grounding cable)are connected to mobile plugs firmly, or mobile plug will
be burned up.
2, After mobile plug is inserted in mobile socket. Make sure they has been tightened reliably.
Or plugs and sockets will be burned up if they are operated long time and current is high. That
is very important.
3, Pay attention electrode of cable. As DC welding machine, it has two connection methods:
positive and regular. Positive connection is that work piece is connected to positive electrode
and holder is connected to negative electrode: negative connection is that work piece is
connected to regular electrode and holder is connected to positive electrode. Choose
connection method according to welding process of work piece. If choose wrong that will
cause unstable are and much spatter and atickong to electobe. If run upon the fault, replace
mobile plugs each other. User does not think welding machine is damaged.
4, If it is too far(50-100m) between work piece and welding machine and secind cables (holder
and grounding cables) is longer, so section of cable must be bigger and adequate to welding in
order to reduce voltage drop of cable.
Power Cable Connection
1,Every welding machine has been disposed once power cable, make sure voltage class is
adequate to once cable according to input voltage of machine. If welding machine of
220v/110v power voltage is connected to AC330v power because of carelessness, that will
cause machine into oner voltage protection situation. Please close power switch and connect
is again. The machine may be operated again after 2-3minutes.
2, Make sure once power is connected to coordinated contact of power or socket reliable and
prevent it from oxidizing.
3, Measure voltage volume if it is in waved arrange by AVO meter.
Check
1, If welding machine is grounded reliably according with demands.
2, All contacts is connected firmly, specially between grounding cable pincer and work piece.
3, Secondary output cable is shortly connected to grounding cable.
4, Make sure secondary output electrode is correct.
5, If circuit protect device is used, leakage current must be max 30A.
6, Spatter of machine can cause fire, so make sure if there are combustibles in welding
environment.