9
To activate the re-entry funtion the short circuit jumper labeled ’EMERGENCY’ needs to be
moved to the two pins on the far right according to the figure attached.
Connect the red and black (NC) cables coming from the emergency exit device to
the control unit on terminal block 41-24. Now the motor lock will remain unlocked if
the emergency exit device has been used to open the door.
Reset is made through closed circuit on terminal block 43-44.
Replace lock case
In order to replace the motor lock case the old unit needs to be unpaired. This is done in the control unit
display menu 3: COMM SET. Select Device: unpaired. A new motor lock can now be installed.
Replace control unit
In order to replace the control unit the same procedure as above is required but in the motor lock case
display. Also to counter any manipulation the bolt has to be unlocked and the door magnet has to be
inactive.
1. Bolt has to be unlocked
2. Ensure the door magnet is inactive
3. Go to menu 3: COMM SET, select Device: change to ’Unpaired’. A new control unit can now be installed
with the motor lock.
TERMINAL DESCRIPTION
Terminal Name Description
1-2 Bolt out Activated when the bolt is out in the locked position
3-4 Bolt in Activated when the bolt is in in the unlocked position
5-6 Door open Controlled through the built-in magnetic door sensor
7-8 Door closed Controlled through the built-in magnetic door sensor
9-10 Impuls Closes the circuit upon activation (eg electric strikes)
11-12 Alarm Activated when the bolt is blocked or door is open
13-14 Bolt out (lock 2) Activated when the bolt is out in the locked position
15-16 Bolt in (lock 2) Activated when the bolt is in in the unlocked position
17-18 Door open (lock 2) Controlled through the built-in magnetic door sensor
19-20 Door closed (lock 2) Controlled through the built-in magnetic door sensor
21-22 Impuls (lock 2) Closes the circuit upon activation (eg electric strikes)
23-24 Alarm (lock 2) Activated when the bolt is blocked or door is open
25-26 Aux relay 1 Programmable relay outputs, see page 11
27-28 Aux relay 2 Programmable relay outputs, see page 11
29-30 Activation (lock 1) Activation through closed circuit
31-32 External magnet (lock 1) Input for external magnet
33-34 Activation (lock 2) Activation through closed circuit
35-36 External magnet (lock 2) Input for external magnet
37-38 Aux relay 1 Programmable relay outputs, see page 11
39-40 Aux relay 2 Programmable relay outputs, see page 11
41-42 Re-entry Input from emergency exit device
43-44 Reset, re-entry Reset when re-entry is activated
45-47 Alarm (re-entry) Alarm (NO/NC) when emergency lever is activated
48-50 RS-485 Connect the motor lock through RS-485
REPLACE UNITS
ACTIVATE RE-ENTRY FUNCTION