GL1 Manual
GL1 v.2.02 EN
GSM gateways

2GL1 v.2.02 EN
Introduction
Introduction
Technical Data 3
General information 4
Installation
Components 5
Connecting the unit 6
Using the sim card 7
LED indication 8
Service
Increase RX audio level 9
Troubleshooting 9
Interference/poor sound quality 10
Certicate
Declaration of conformity 11
Content

3
SafeLine GL1
GL1 v.2.02 EN
Introduction
Power: Supply voltage: 10-30 VDC
Line Power: Line voltage: 48 VDC when connected to GSM network.
Current consumption: 12 VDC
250 mA, momentarily when connecting a call.
50 mA at Standby.
Communication: GSM-module Dual Band 900/1800 MHz.
Antenna connector type: SMA (female)
IP code: IP20
Size: 81 x 121 x 24 mm (H x W x D)
Weight: 220 gram
Unit is beeing delivered with a 3 m antenna cable, SMA contact (male).
Technical Data Main Unit

4
elektroniske produkter. Korrekt bortskaffelse af dit gamle produkt hjælper med at forhindre negative
følger for miljøet og helbredet.
GL1 v.2.02 EN
Introduction
This unit was built with state-of-the-art technology and to
generally recognised safety related technical standards currently app-
licable. These installation instructions are to be followed by all people
working with the unit, in both installation and maintenance.
It is extremely important that these installation instructions are made
available at all times to the relevant technicians, engineers or servicing
and maintenance personnel. The basis prerequisite for safe handling
and trouble free operation of this system is a sound knowledge of the
basic and special safety regulations concerning conveyor technology,
and elevators in particular. The unit may only be used for its intended
purpose. Note in particular that, no unauthorised changes or additions
may be made inside the unit or individual components.
Exclusion of liability
The manufacturer is not liable with respect to the buyer of this product
or to third parties for damage, loss, costs or work incurred as a result of
accidents, misuse of the product, incorrect installation or illegal chang-
es, repairs or additions. Claims under warranty are likewise excluded in
such cases. The technical data is the latest available. The manufacturer
accepts no liability arising from printing errors, mistakes or changes.
Declaration of conformity
Download ”The declaration of conformity” at our website:
www.safeline-group.com
Safety Precautions!
- Only trained professionals, who are authorised to work on the equip-
ment, should install and con gure this produc t.
- This quality product is dedicated for the lift industry. It has been
designed and manufactured to be used for its speci ed purpose only.
If it is to be used for any other purpose, SafeLine must be contacted in
advance.
- It should not be modi ed or altered in any way, and should only be
installed and con gured strictly following the procedures described in
this manual.
- All applicable health and safety requirements and equipment
standards should be considered and strictly adhered to when installing
and con guring this product.
- After installation and con guration this product and the operation
of the equipment should be fully tested to ensure correct operation
before the equipment is returned to normal use.
Electrical and electronic products may contain materials, parts and
units that can be dangerous for the environment and human health.
Please inform yourself about the local rules and disposal collection
system for electrical and electronic products. The correct disposal of
your old product will help to prevent negative consequences for the
environment and human health.
General
information

5
1
2
3a
4
3b 3c
5
6
77
GL1 v.2.02 EN
Installation
Components
This unit was built with state-of-the-art technology and to
generally recognised safety related technical standards currently app-
licable. These installation instructions are to be followed by all people
working with the unit, in both installation and maintenance.
It is extremely important that these installation instructions are made
available at all times to the relevant technicians, engineers or servicing
and maintenance personnel. The basis prerequisite for safe handling
and trouble free operation of this system is a sound knowledge of the
basic and special safety regulations concerning conveyor technology,
and elevators in particular. The unit may only be used for its intended
purpose. Note in particular that, no unauthorised changes or additions
may be made inside the unit or individual components.
Exclusion of liability
The manufacturer is not liable with respect to the buyer of this product
or to third parties for damage, loss, costs or work incurred as a result of
accidents, misuse of the product, incorrect installation or illegal chang-
es, repairs or additions. Claims under warranty are likewise excluded in
such cases. The technical data is the latest available. The manufacturer
accepts no liability arising from printing errors, mistakes or changes.
Declaration of conformity
Download ”The declaration of conformity” at our website:
www.safeline-group.com
Safety Precautions!
- Only trained professionals, who are authorised to work on the equip-
ment, should install and con gure this produc t.
- This quality product is dedicated for the lift industry. It has been
designed and manufactured to be used for its speci ed purpose only.
If it is to be used for any other purpose, SafeLine must be contacted in
advance.
- It should not be modi ed or altered in any way, and should only be
installed and con gured strictly following the procedures described in
this manual.
- All applicable health and safety requirements and equipment
standards should be considered and strictly adhered to when installing
and con guring this product.
- After installation and con guration this product and the operation
of the equipment should be fully tested to ensure correct operation
before the equipment is returned to normal use.
Electrical and electronic products may contain materials, parts and
units that can be dangerous for the environment and human health.
Please inform yourself about the local rules and disposal collection
system for electrical and electronic products. The correct disposal of
your old product will help to prevent negative consequences for the
environment and human health.
General
information
1. SIM-card holder
The unit is using a micro SIM card.
2. SMA-antenna connector
The SMA-antenna connector type is female.
3. Terminal
Connection for supply voltage of:
a) Telephone line out for SafeLine phones.
b) 0 VDC
c) 10-30 VDC
4. Reset button
Push the reset button for 3 sec to see GSM eld intensity.
5. LED’s
There are three LED indicators. Refer to the ”LED indication” on
page 7.
6. Mini USB
Use the mini USB connection and the SLPro to update SW.
7. Holder
It is possible to attach the GL1 with either the DIN holder or the
optional holder.

6
GL1
1,5 m 1,5 m
1,5 m
GL1 v.2.02 EN
Installation
To avoid GSM interference: Place the GL1, the lift emergency
telephone and the GSM antenna at least 1,5 m apart.
Connecting
the unit

7GL1 v.2.02 EN
Installation
Using the
SIM card
If you enter the wrong PIN code
3 times, the SIM card will be
blocked (requires PUK code to
de-block). The GL1 cannot be
started and the LED3 will be red.
Before you can start using a new SIM card, the card has to be prepared
and support 2G network. Cards that only support 3G will not function.
• If the PIN code is set to ”1234”, “0000” or if it is deactivated
the SIM card can be moved from the SafeLine GL to any of the
SafeLine GSM products.
• If the PIN code is set to “1111” the SIM card cannot be moved to
any other telephone (SafeLine or otherwise) without the PUK code.
Do not activate the voicemail or if possible ask your provider to
deactivate the voicemail.
If the PIN code is set to “1111” the SIM cards code will be randomly
changed by the SafeLine GSM unit and memorised. This way the
SIM card can only work with the SafeLine GSM unit unless you use
the PUK code for setting up a new PIN code.
If you want to upload a new SIM card with PIN code “1111” you will
need to rst upload a SIM card with PIN code “1234” or “0000” this
to clear the old code in memory.
PIN code (set to “1234”, “0000” or deactivate).
1. Insert the SIM card in an ordinary mobile phone. In the “Security
settings” menu, change the PIN code to “1234”, “0000” or set the
”PIN code request” option to “OFF”.
NOTE! ”0000” can not be use on all SIM cards. Please contact your
service provider for details.
2. Verify the PIN code by switching your phone off and on again.
3. Make a call from your phone to verify that the SIM card is active,
before you move it to the SafeLine GL1.
4. Also make a call to SafeLine GL1 after insertion of the SIM card,
to check that it is possible to get a proper connection.
Protect the SIM card against unauthorized use.
1. Insert the SIM card in a mobile phone.
2. In the “Security settings” menu, change the PIN code to “1111”.
When the SIM card is inserted in the SafeLine unit, the code will be
changed to a random number, thus making it impossible to use the
card in another mobile phone unless it is unblocked by means of
the PUK code.

8GL1 v.2.02 EN
Installation
LED1, indicates the power supply status
Continuous green Power supply OK.
LED2, indicates GSM strength
Indicates GSM strength and recieving audio level, RX-level
(please refer to the tables).
LED3, indicates communication
Continuous red GSM error.
Flashing red
(400/400 ms)
Searching for GSM network.
Flashing yellow/green
(100/100 ms)
Incoming call.
Continuous green Call connected.
Flashing green
(400/400 ms)
Call connection in progress.
Slowly ashing green
(200/4600 ms)
GSM network OK.
Flashing green
(100/100/100/2200 ms)
Handset not applied to/put
on the unit correctly.
LED Indication
LED
1 2 3 GSM SIGNAL
STRENGTH
= 100 %
= 85 %
= 70 %
= 55 %
= 30 %*
= 15 %
= 0 %
*Minimum signal strength for
using GSM interface.
LED 1
LED 2
LED 3

9GL1 v.2.02 EN
Service
It is also possible to adjust the set-
tings via SLPro, under the GL6 tab.
LED
1 2 3 RX AUDIO
LEVEL
= 0 %
= 25 %
= 50 %
= 75 %
= 100 %
Increase the GSM receiving audio level by using of the setup mode.
1. To enter setup mode, rst disconnect the power.
2. Then press the button and hold while restarting power and then for a
further 3seconds without letting go. The setup mode is now active.
3. To setup the GSM receiving audio level press the button to reach
desired output level. The increase is in steps of 25% per push.
4. When the desired level is reached, turn off the power.
5. Then restart the unit. The new GSM receiving audio level is now
stored.
Increase RX
audio level
Troubleshooting LED1 is not lit when when the unit is connected to supply voltage.
• Check the supply voltage polarity.
• Make sure that the supply voltage is 10-30 VDC.
LED3 is lit, continous red.
• Make sure that the SIM-card is correctly positioned.
• Check that the SIM-cards PIN-code is deactivated or that the
PIN-code is set to ”1234”, ”0000” or ”1111” (see the section
SIM-card).
• Make sure that the SIM–card is activated and works by testing
the card in an mobile phone.
The call is interrupted directly after being connected.
• If the unit is powered from a battery make sure the battery is
properly charged.
• Make sure that the main power supply can deliver 300 mA
continuous current.
Call can not be connected! Error message from telephone operator.
• To make a call, area code must always be used.

10 GL1 v.2.02 EN
Service
Interference/
poorsound quality
• Bear in mind that the wiring between GL and the lift telephone/
phone is basically a standard PSTN-line and can therefore not
be placed in the lifts travelling cable together with high voltage.
***(Risk of interference)***
• Always place the antenna in an upward position and at least
1,5 m from GL.
• Place the antenna where the highest eld intensity is obtained
according to the table (”LED indication”, page <?>) for the unit.
• When a call is connected try placing the antenna in different
places to nd where the best receiving/sending position is.

Your partner in lift safety
Antennvägen 10, 13548 Tyresö, Sweden
+46 (0)8-447 79 32, www.safeline-group.com
EU Declaration of Conformity
Product: Mobile network emulator
Type / model: Safeline GL1
Article no: *GL1
Manufacturer: SafeLine Sweden AB
Year: 2017
We herewith declare under our sole responsibility as manufacturer that the products referred to
above complies with the following EC Directives:
Directives
Radio Equipment (RED): 2014/53/EU
RoHS 2: 2011/65/EU
Standards applied
EN 12015:2014 EMC: Emission, Electromagnetic compatibility
EN 12016:2013 EMC/Lifts: Immunity, Electromagnetic compatibility
EN 62368–1:2014/AC:2015 LVD: Information Technology Equipment
EN 50581:2012 RoHS: Technical doc. for assessment of restriction of RoHS.
For RED 2014/53/EU, the conformity assessment procedure “Module A” used as described in Annex II. Accordingly, respective
manufacturer has done the radio modules conformity assessment:
Standards applied Article of Directive 2014/53/EU
EN 60950-1:2006+A11:2009+A1:2010+A12:2011+A2:2013 3.1 (a): Health and safety of the user
EN 62311:2008
EN 301 489-1 v2.1.1 + EN 301 489-52v1.1.0 Draft 3.1 (B): Electromagnetic Compatibility
EN 301 511 v12.5.1 3.2: Effective use of spectrum allocated
Firmware used during assessment
GL865-Dual V3: 16.00.152 / 16.01.150 / 16.01.153
SafeLine GL1: 1.00
Tyresö, 2017-04-07
Lars Gustafsson,
Technical Manager, R&D , SafeLine Group
Module
Notified body
Address
NB nr
Test nr
GL865-Dual V3
Dekra Test &Cert
Parque Tecnologico de Andalucia / SeveroOchoa
2, 29590 Spain
1909
53051 RBN.001

www.safeline-group.com www.safeline-group.com
SafeLine Europe
Industrieterrein 1-8 · 3290 Diest · Belgium
Support: +32 (0)4 85 89 08 95
SafeLine Deutschland GmbH
Kurzgewannstraße 3 · D-68526 Ladenburg · Germany
SafeLine Norway
Solbråveien 49 · 1383 Asker · Norway
SafeLine Denmark
Erhvervsvej 19 · 2600 Glostrup · Denmark
SafeLine Headquarters
Antennvägen 10 · 135 48 Tyresö · Sweden
Support: +46 (0)8 448 73 90
SafeLine Group UK
Unit 47 · Acorn Industrial Park · Crayford ·
Kent · DA1 4AL · United Kingdom
Other manuals for GL1
3
Table of contents
Other Safeline Gateway manuals