Safeline GL1 User manual

SafeLine
GL1
06.2016 www.safeline-group.com
108
42
121 24
81
4 x 5,5
2 x 9,5
MANUAL
GL1 v1.011 EN
Lift emergency telephone
A GSM alternative for all of our lift telephones.

2© 2016 SafeLine and all the SafeLine products and accessories are copyrighted by law.
SafeLine
GL1
GL1 v1.011 EN
TECHNICAL DATA
Power: Supply voltage: 10-30 VDC
Line Power: Line voltage: 48 VDC when connected to GSM network.
Current consumption: 12 VDC
250 mA, momentarily when connecting a call.
50 mA at Standby.
Communication: GSM-module Dual Band 900/1800 MHz.
Antenna connector type: SMA (female)
IP code: IP20
Size: 81 x 121 x 24 mm (H x W x D)
Weight: 220 gram
Unit is beeing delivered with a 3 m antenna cable, SMA contact (male).

3
© 2016 SafeLine and all the SafeLine products and accessories are copyrighted by law.
GL1 v1.011 EN
SERVICE
START UP
INSTALLATION
Table of contents
Components 4
Using the SIM card 5
LED indication 6
Increase RX audio level 6
Troubleshooting 7
Interference/poor sound quality 7

4© 2016 SafeLine and all the SafeLine products and accessories are copyrighted by law.
>> 1,5 m
>> 1,5 m
>> 1,5 m
SafeLine GL1
N
P
X
045
100
16E
045
100
16E
045
100
16E
045
100
16E
045
100
16E
045
100
16E
42432
1000
35E
42432
1000
35E
GL1 v1.011 EN
Installation
COMPONENTS
SIM-card holder
The unit is using a micro SIM card.
SMA-antenna connector
The SMA-antenna connector type is female.
Terminal
Connection for supply voltage of 10-30 VDC and
telephone lines for SafeLine phones.
Reset button
Push the reset button for 3 sec to see GSM field
intensity.
LED’s
There are three LED indicators. Refer to the
”LED indication” on page 6.
Mini USB
Use the mini USB connection and the SLPro to
update SW.
Holder
It is possible to attach the GL1 with either the
DIN holder or the optional holder.
CONNECTING THE UNIT
To avoid GSM interference: Place the GL1, the lift
emergency telephone and the GSM antenna at
least 1,5 m apart.
LED2
LED3
LED1
Reset button
SMA-antenna connector
Micro
SIM-card
10-30 VDC
0 VDC
Telephone line out
Telephone line out
DIN holderOptional holder
Mini USB
SIM-card holder

5
© 2016 SafeLine and all the SafeLine products and accessories are copyrighted by law.
GL1 v1.011 EN
Installation
Before you can start using a new SIM card,
the card has to be prepared and support 2G
network. Cards that only support 3G will not
function.
• If the PIN code is set to ”1234”, “0000” or if
it is deactivated the SIM card can be moved
from the SafeLine GL to any of the SafeLine
GSM products.
• If the PIN code is set to “1111” the SIM card
cannot be moved to any other telephone
(SafeLine or otherwise) without the PUK code.
Do not activate the voicemail or if possible ask
your provider to deactivate the voicemail.
If the PIN code is set to “1111” the SIM cards code
will be randomly changed by the SafeLine GSM
unit and memorised. This way the SIM card can
only work with the SafeLine GSM unit unless you
use the PUK code for setting up a new PIN code.
If you want to upload a new SIM card with PIN
code “1111” you will need to first upload a SIM card
with PIN code “1234” or “0000” this to clear the
old code in memory.
PIN code (set to “1234”, “0000” or deactivate).
1. Insert the SIM card in an ordinary mobile
phone. In the “Security settings” menu,
change the PIN code to “1234”, “0000” or
set the ”PIN code request” option to “OFF”.
NOTE! ”0000” can not be use on all SIM
cards. Please contact your service provider
for details.
2. Verify the PIN code by switching your phone
off and on again.
3. Make a call from your phone to verify that the
SIM card is active, before you move it to the
SafeLine GL1.
4. Also make a call to SafeLine GL1 after
insertion of the SIM card, to check that it is
possible to get a proper connection.
Protect the SIM card against unauthorized use.
1. Insert the SIM card in a mobile phone.
2. In the “Security settings” menu, change
the PIN code to “1111”. When the SIM card is
inserted in the SafeLine unit, the code will be
changed to a random number, thus making it
impossible to use the card in another mobile
phone unless it is unblocked by means of the
PUK code.
If you enter the wrong PIN code 3 times, the
SIM card will be blocked (requires PUK code
to de-block). The GL1 cannot be started and
the LED3 will be red.
USING THE SIM CARD

6© 2016 SafeLine and all the SafeLine products and accessories are copyrighted by law.
N
P
X
045
100
16E
045
100
16E
045
100
16E
42432
1000
35E
GL1 v1.011 EN
Start up
LED INDICATION
LED1, indicates the power supply status
Continuous green Power supply OK.
LED2, indicates GSM strength
Indicates GSM strength and recieving audio level, RX-level (please refer to the tables).
LED3, indicates communication
Continuous red GSM error.
Flashing red (400/400 ms) Searching for GSM network.
Flashing yellow/green (100/100 ms) Incoming call.
Continuous green Call connected.
Flashing green (400/400 ms) Call connection in progress.
Slowly flashing green (200/4600 ms) GSM network OK.
Flashing green (100/100/100/2200 ms) Handset not applied to/put on the unit
correctly.
LED1 LED2 LED3
*Minimum signal strength for using GSM Interface.
INCREASE RX AUDIO LEVEL
Increase the GSM receiving audio level by using
of the setup mode.
1. To enter setup mode, first disconnect the
power.
2. Then press the button and hold while
restarting power and then for a further
3 seconds without letting go. The setup mode
is now active.
3. To setup the GSM receiving audio level press
the button to reach desired output level. The
increase is in steps of 25% per push.
4. When the desired level is reached, turn off the
power.
5. Then restart the unit. The new GSM receiving
audio level is now stored.
It is also possible to adjust the
settings via SLPro, under the
GL6 tab.
COLOUR CODE LED
1 2 3
SIGNAL
STRENGTH
3 green = 100 %
1 yellow, 2 green = 85 %
2 yellow, 1 green = 70 %
3 yellow = 55 %
1 red, 2 yellow* = 30 %
2 red, 1 yellow = 15 %
3 red = 0 %
COLOUR CODE LED
1 2 3
RX AUDIO
LEVEL
Not lit (default) = 0 %
1 green = 25 %
2 green = 50 %
3 green = 75 %
1 red, 2 green = 100 %

7
© 2016 SafeLine and all the SafeLine products and accessories are copyrighted by law.
GL1 v1.011 EN
Service
LED1 is not lit when when the unit is connected
to supply voltage.
• Check the supply voltage polarity.
• Make sure that the supply voltage is
10-30 VDC.
LED3 is lit, continous red.
• Make sure that the SIM-card is correctly
positioned.
• Check that the SIM-cards PIN-code is
deactivated or that the PIN-code is set to
”1234”, ”0000” or ”1111” (see the section
SIM-card).
• Make sure that the SIM–card is activated and
works by testing the card in an mobile phone.
The call is interrupted directly after being
connected.
• If the unit is powered from a battery make
sure the battery is properly charged.
• Make sure that the main power supply can
deliver 300 mA continuous current.
Call can not be connected! Error message from
telephone operator.
• To make a call, area code must always be used.
INTERFERENCE/
POOR SOUND QUALITY
• Bear in mind that the wiring between GL
and the lift telephone/phone is basically a
standard PSTN-line and can therefore not be
placed in the lifts travelling cable together
with high voltage. ***(Risk of interference)***
• Always place the antenna in an upward
position and at least 1,5 m from GL.
• Place the antenna where the highest field
intensity is obtained according to the table
(”LED indication”, page 6) for the unit.
• When a call is connected try placing the
antenna in different places to find where the
best receiving/sending position is.
TROUBLESHOOTING

www.safeline-group.com
SafeLine Europe
Interleuvenlaan 62 · 3001 Heverlee · Belgium
Tel.: +32 (0)16 39 48 66 · info@safeline.eu
Support: +32 (0)4 85 89 08 95
SafeLine Elevator Parts UK
3 Evegate Park Barn · Station Road · Smeeth · Ashford · Kent · TN25 6SX · United Kingdom
Tel.: +44 (0)1303 813414 · info@safeline.uk.com
Support: +44 (0)1303 813 414
SafeLine-Deutschland
Westfalenstraße 22a · D-51688 Wipperfürth · Germany
Tel.: +49 (0) 2267 - 8 67 96 63 · info@safeline-deutschland.de
Support:+49 (0) 2267 - 8 67 97 97
SafeLine Norway
Solbråveien 49 · 1383 Asker · Norway
Tel.: +47 94 14 14 49 · post@safeline.no
Support: +47 94 14 14 49
SafeLine Headquarters
Antennvägen 10 · 135 48 Tyresö · Sweden
Tel.: +46 (0)8 447 79 32 · info@safeline.se
Support: +46 (0)8 448 73 90
SafeLine Denmark
Erhvervsvej 19 · DK - 2600 Glostrup · Denmark
Tel.: +45 44 91 32 72 · info-dk@safeline.se
Support: +45 44 91 32 72
SafeLine - Your partner in lift safety
Other manuals for GL1
3
Table of contents
Other Safeline Gateway manuals
Popular Gateway manuals by other brands

RTA
RTA 460US-NNA4 Product user guide

THOMSON
THOMSON TWG850 quick start guide

Agilent Technologies
Agilent Technologies E2050 Installation and configuration guide

Brocade Communications Systems
Brocade Communications Systems Gateway Administrator's guide

Valcom
Valcom VE8024A manual

CellGate
CellGate Omnipoint Hardware guide