Saia Burgess Controls PCD7.L65T-RC5 Series User manual

Saia-Burgess Controls AG
Bahnhofstrasse 18, 3280 Murten, Switzerland
Tel +41 26 580 30 00, Fax +41 26 580 34 99
www.saia-pcd.com
PP26-058_ENG01
2018-04-25
MC
Metallic ceiling
Screen
RC5x
The distance
between the remote
control unit and the
device is less than
Floor
Remote control PCD7.L65T-RC5x
PAIRING INSTRUCTIONS
To pair your remote control with a radio-frequency device, point it to the device from a distance of 1 to 2 metres.
Please remember, only one remote control can be paired at a time.
Pairing with a device built into the ceiling
In an upright position, if paired with a device built into the ceiling (PCD7.L66D-MC72V)
Pairing with a device built into a suspended metallic ceiling
Where the suspended ceiling is made of metal, the
pairing distance is shorter, less than 30 cm.
If a suspended ceiling is added after the pairing has
been completed, the connection between the remote
and the multi-sensor might be lost.
Once pairing is complete, the connection will be
maintained at distances of up to 7 m or more in the
presence of suspended metallic ceilings.
RC5x in an upright position
MC
Ceiling
Screen
RC5x
Distance:
1 to 2 metres
Height
1.20 m to 1.50 m
Floor
!
!
Saia-Burgess Controls AG
Bahnhofstrasse 18, 3280 Murten, Switzerland
Tel +41 26 580 30 00, Fax +41 26 580 34 99
www.saia-pcd.com
PP26-058_ENG01
2018-04-25
Remote control PCD7.L65T-RC5x
1. Pairing Menu
Connect the radio-frequency device to your regulator’s DALI network
Turn on the remote control unit by pressing the “occupation” button
Press the following 2 buttons simultaneously: “light” and “occupation”
The pairing menu should come on
The distance [between the remote control unit and the pairing device] should be between 1 and
2 metres
The remote control unit should be in an upright or horizontal position as indicated in the above
diagram
Start the pairing by pressing the OK button
oThe remote control unit searches for devices situated at a distance of 3 to 4 metres
oAll MCs responding to the remote control unit will have their green LED lit
oOnce the search is completed (approximately 10 s), use the ± buttons to select a device and press OK to
confirm (the selected device should have the RSSI which is closest to zero)
If the device is flashing: (only applicable to PCD7.L66D-MC72V)
oIf the device’s LED is flashing red and green: press the OK button
oIf not, press the RET button and select another device using the ± button
oIf none of the devices detected is the one you wish to connect to, press on “Occupation” again
(this function might not be available in all remote control versions)
At the end of pairing
oIf pairing is successful, “pairing OK” will be displayed on the screens: press OK to confirm
oIf pairing is not successful, the screen will display “pairing NOK”: press the RET button to try again
Before you can pair with a new device, existing pairing configurations must be cleared from
both the remote control unit and the MC device.
2. Clearing the pairing memory
Connect the radio-frequency device to your regulator’s DALI network
Turn on the remote control unit by pressing the “occupation” button
Press the + and – buttons simultaneously and hold them for 1 second
The sign “!” will appear in the top left corner of the screen
Press the + and – buttons simultaneously again and hold them for 1 second
The “config BA” menu will be displayed
Press the “light” and “temperature” buttons simultaneously
Select “config Radio” from the menu, using the + and – buttons and press OK to confirm
Select the “Delete AC” menu using the + and – buttons and press OK to confirm
oThe remote control unit searches for devices situated at a distance of 3 to 4 metres.
oOnce the search is completed (approximately 10 s), you can select the desired device by using the ± keys.
Press OK to confirm.
oIf the device is flashing:
If the device starts to flash: press the OK button
If not, press the RET button and select another device using the ± button
!

Popular Remote Control manuals by other brands

Flying Industry Development 6S2UB-DC12+1CV-12 quick guide

Flying Industry Development

Flying Industry Development 6S2UB-DC12+1CV-12 quick guide

Long range MT4300 instruction manual

Long range

Long range MT4300 instruction manual

Faber GV60TT/10 user manual

Faber

Faber GV60TT/10 user manual

Sanyo Moonlight RMT-U110 owner's manual

Sanyo

Sanyo Moonlight RMT-U110 owner's manual

Midland BT Remote user guide

Midland

Midland BT Remote user guide

Siku SIKUCONTROL 6701 operating instructions

Siku

Siku SIKUCONTROL 6701 operating instructions

RCA RCR002RWDZ owner's manual

RCA

RCA RCR002RWDZ owner's manual

O6 O6 Portable Smart Bluetooth user guide

O6

O6 O6 Portable Smart Bluetooth user guide

Flying Industry Development S1X2-DC quick guide

Flying Industry Development

Flying Industry Development S1X2-DC quick guide

Vivo E-FD55 FD55 user guide

Vivo

Vivo E-FD55 FD55 user guide

Wibre 5.0690.09.55 installation manual

Wibre

Wibre 5.0690.09.55 installation manual

Roland RC-100 quick guide

Roland

Roland RC-100 quick guide

Sunricher ZG9003T3-RGBW-US Operation manual

Sunricher

Sunricher ZG9003T3-RGBW-US Operation manual

Trikdis GV14 user manual

Trikdis

Trikdis GV14 user manual

Hunter SRR Owner's manual and installation instructions

Hunter

Hunter SRR Owner's manual and installation instructions

Harmony One How to install

Harmony

Harmony One How to install

Eaton xComfort CHSZ-12/03 Instruction leaflet

Eaton

Eaton xComfort CHSZ-12/03 Instruction leaflet

Alpine communications FusionTV quick start guide

Alpine communications

Alpine communications FusionTV quick start guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.