IMPORTANT: IN THE INTEREST OF PRODUCT PERFORMANCEAND SAFETY PLEASE READ THESE INSTALLATION ANDWARRANTY INSTRUCTIONS BEFORE INSTALLING THE PRODUCT.
MUST BE INSTALLED
BY A LICENSED
ELECTRICIAN
DIY
SAL products are designed in accordance with all mandatory International and AS/NZS Standards, which require installation in
accordance with AS/NZS3000 by a qualified installer and regular cleaning and maintenance of the equipment. Products are
sold in accordance with the following instructions and SAL standard terms and conditions of sale, available via www.sal.net.au.
Due to continued product and information updates, product data sourced from sal.net.au shall not form part of any contract and or technical performance
guarantee unless expressly confirmed in writing by SAL at the time of order.
General product application requirements (if applicable) :
1. CCT or POWER selections (where supplied) – IMPORTANT, where CCT colour temperature or POWER selection switching is provided, it is important to switch OFF the
power before the selection is made, otherwise equipment damage may occur.
2. Recycling – SAL encouragesrecycling, please consider the environment when disposing of packaging, batteries & components.
3. Switching or test intervals –For optimum product performance, good design practice doesnot encourage 24/7 operation of lighting products without the provision
of a routine switching or regulatorytest cycle. Asaguide for continual operation installations, atwelve (12) hour duration for Industrial and Commercial applications
and a six (6) hour duration for Residential applications should be considered.
4. Product maintenance – In line with the relevant design standards and to protect your investment, it is important to have in place aroutine cleaning program that
reflects the installation environment and maintains the product in a clean and functional condition.
IMPORTANT - The supply must be isolated before any product maintenance or cleaning is conducted. In addition, damage to ANY cable or cord supplied with the
product must be addressed as follows; For attachment type X having a specially prepared cable, if the external flexible cable is damaged, it must be replaced by an
equivalent cable exclusively available from the manufacturer or authorised installer. For attachment type Y, if the external flexible cable is damaged, it must be
exclusively replaced by an equivalent cable by the manufacturer or authorised installer. For attachment type Z, if the external flexible cable is damaged, the cable
cannot be replaced and the luminaire must be destroyed.
5. Adverse, corrosive and coastal installation environments –Unless the product is specifically designated for such applications in these installation instructions, which is
supported by a professional maintenance program; installation of equipment in such environments is not recommended.
6. Dimming products – Dimming circuits and product compatibility must be validated by the installer before installation; SAL cannot be responsible for third party
changes in dimmer compatibility.
7. Suspended products –For installation safety, any suspended productsmust NOT be installed in high air movement spacesor locations subject to impact.
8. Light source replacements – (Non-replaceable light sources) - The light source of the product is deemednot replaceable, when the product reaches its end of life
the complete product, it must be replaced by a qualified installer. (Non-user replaceable light sources) - The light source of the product must only be replaced by the
manufacturer or qualified installer. Caution, risk of electricshock.
9. Interior downlights and sensors with remote drivers and electrical accessories –The mounting facilities provided for the transformer/driver (if any), need only be
utilized if in the application of the product is required by AS3000. Drivers are not designed for installation environments that restrict conventional airflow.
10. Floodlight products– Unless nominated aiming restrictions or installation parameters apply, products are designed for installation environments between ground and
15 metres in height, subject to the desired optical performance being achieved. For floodlight installation environments that have restricted access (eg: columns and
roof-lines) which are subject to unstable electrical supply or electrical surges (which void warranty), consideration of the installation of an independent surge protector
is strongly recommended.
11. Emergency enabled products – In the interest of transport and safety, emergency products are supplied with the battery disconnected. In addition to specific
emergency commissioning instructions, this battery MUST be connected at the time of installation. Continual use in emergency mode greater than 240 hours without
recharge, will result in battery failure and void battery warranty.
Nominal frequency (Hz) Product installation orientation
Operating ambient min/max (°C) Product application
Operating humidity Pixie connectivity
Storage ambient limit (°C) IP rating*
Storage humidity Attachment type
Enclosed in approved product50
IP rating for interior products: The designated IP rating is “from below the ceiling” unless otherwise specified.
IP rating ALL products: Termination of the product must be made in accordance with the IP rating.
0to 40 Interior residentialor commercial
10% to 85% RH, NC
0to 40 20
N/A10% to 85% RH, NC
No
Model No. Input (V)/(Hz)
Dimension L x W x H (mm) Sensor type
Microwave
SMS830 220-240/50 LED 300 / INCAND 1000W White 122 x 31 x 29
Max loads Colour

SAL National PtyLtd.
40 Biloela Street
Villawood NSW 2163 ABN 21 633 189 474
Copyright SAL V16 JUL 2021 |
www.sal.net.au
| Page 2of 3
12. Specific installation procedures (if any) - this device must be installed by a licensed electrician:
Specifications
Parameter setting
TIME: S3,S4,S5SENS: S1,S2 LUX: S6
S1 S2 S3 S4 S5 S6
Switch to the ON position as "1",
Switch to the OFF position as "0”
TIME:S3,S4,S5
S3 S4 S5
S3 S4
1 1
11
0 1
01
10
S5 TIME
130min
20min
3min
5min
0
0
1
0 10min
0 0 10s
0
0 01min
1
1015min
1
Troubleshooting
360
Detection angle
2.5-3.5m
Height of installation 2.5~3.5M
Min:1m Min:1m
Max: 6m Max: 6m
Height of installation 2.5m
detection range
Detection range setting (sensitivity)
Detection range is the term used to describe the less circular detection zone
produced on the ground the sensor light at a height of 2.5m, switch location
and detection range of the corresponding table is as follows:
SENS:S1,S2
S1 S2
S1 S2 detection range
0 0 25%
0 1 50%
1 0 75%
100%
1 1
NOTE: the above detection range is gained if the detected person is between
1.6m~1.7m tall and moves at a speed of 1.0~1.5m/sec. if a person’s stature,
figure or moving speed changes, the detection distance will also change.
Switch to the ON position as "1",
Switch to the OFF position as "0”,
Time setting
The light can be set to stay ON for any period of time between approx.10sec
and a maximum of 30min. Any movement detected before this time elapse
will re-start the timer.
It is recommended to select the shortest time for adjusting the detection zone
and for performing the walk test. Switch location and detection range of the
corresponding table is as follows:
•Transmission power: <0.2mW
•Rated load:
1000W/5A, Max, incandescent lamp (cosφ=1)
300W/2.5A, Max, fluorescent lamp and LED lamp (cosφ=0.5)
•HF system: 5.8GHz CW electric wave, ISM band
•Detection angle: 360°
•Detection range: 25%/50%/75%/100% (radii).(adjustable)
•Time setting: 10sec/1min/3min/5min/10min/15min/20min/30min(adjustable)
•Light-control: 24H/10-80lux range
•Power consumption: approx 0.5W
•The advantage of this product is stable performance at working
temperatures: 0°C~+40°C, SMS830 adopts a microwave sensor
(highfrequency output<0.2mW), so that it is safe to use.
Shown in chart below:By setting the S1, S2 to set the detection RANGE
of products, by setting S3,S4,S5 to set the DELAY time of products, by
setting the S6 to set the LIGHT-control of products.
NOTE: The product will not function correctly where the sensor is
located behind metallic structures or enclosed in a ceiling cavity.
Malfunction
Cause
Adjust setting
Load faulty Change load
Mains switch OFF Switch ON
check zone setting
the sensor location is incorrect securely mount the enclosure location
Check zone setting
Check zone setting
Incorrect light-control setting selected
Remedy
Movement occurred, but was not identified by the sensor
(movement behind wall, movement of a small object in
immediate lamp vicinity etc. )
Rapid movements are being suppressed to minimize
malfunctioning or the detection zone you have set is too small
The sensor/light will not operate
despite movement
The sensor/light operates without
any identifiable movement
The sensor/light is ON all of the time
The sensor/light will not work
Continuous movement in the detection zone
NOTE: after the light switches OFF, it takes approx. 4sec before it is able to
start detecting movement again. The light will only switch on in response
to movement once this period has elapsed.
Light-control setting
LUX:S6
S6
S6 LUX
024H
110-80 LUX
The chosen light response threshold can be infinitely from approx. 10-80
lux/24H, switch to the ON position as "1" , switch to the OFF position as "0”,
switch location and light-control of the corresponding table is as follows:
Wiring diagram

SAL National PtyLtd.
40 Biloela Street
Villawood NSW 2163 ABN 21 633 189 474
Copyright SAL V16 JUL 2021 |
www.sal.net.au
| Page 3of 3
13. Warranty – In accordance with SAL’s standard terms and conditions of sale, SAL warrant this product to be free from defects in materials and or workmanship for a
period as stated below for goods not subject to incorrect installation, maintenance, operation, mishandling, environmental, unauthorised modifications or electrical
operating conditions outside the nominated product specification as detailed in these installation instructions. The benefits to you given by this warranty are in addition to
other rights and remedies you have under law. Our goods come with guarantees that cannot be excluded under the Australian Consumer Law. You are entitled to a
replacement or refund for a major failure and compensation for any other reasonably foreseeable loss or damage. You are also entitled to have the goods repaired or
replaced if the goods fail to be of acceptable quality and the failure does not amount to a major failure.
Warranty term – Residential usage (36) months, Commercial usage (24) months, Replaceable Lamps (where supplied) (12) months and Lithium batteries where supplied
(24) months from date of purchase. For New Zealand, please refer to www.sal.co.nz for warranty conditions and service.
How to make a claim?
Step # 1 –Within 30 days of the fault discovery, please contact the original place of the SAL product purchase during standard (local) business hours, with the following
information (a) proof of purchase (b) description and quantity of the claimed fault (c) address of installation. (d) operating hours of the product.
Step # 2 – It is then the responsibility of the original place of product purchase to report the matter to SAL aftersales;
NSW | ACT - SAL National Pty Ltd, 40 Biloela Street Villawood NSW 2163 | P # 02 9723 3099
QLD - SAL National Pty Ltd, 36 Whitelaw Place Richlands QLD 4077 | P # 07 3879 5999
VICT | TAS - SAL National Pty Ltd, 46-48 Keys Road Moorabbin Victoria 3189 | P # 03 9532 3168
SA | NT - SAL National Pty Ltd, Unit 1, 9 Alfred Avenue, Beverley SA 5009 | P # 08 7084 1958
WA - SAL National Pty Ltd, 29 Beringarra Av Malaga WA 6090 | P # 08 9248 7458
NZ - Hamer, 130 Bush Road, Albany, Auckland, 0632 | P # 0800 239 239
Step # 3 - Upon review of your claim and if the product is required to be returned to SAL for technical evaluation, then at the owners expense the product must be
returned to SAL as per the above nominated locations.
Step # 4 - Pending the evaluation, the claim will be validated resulting in the product being repaired or replaced with the same or best equivalent product at the
discretion of SAL, or rejected if the product fault was found to be caused by conditions beyond the responsibility of SAL warranty obligations. Consideration of installation,
product removal, return freight and or testing fees are not the responsibility of SAL.
Other SAL Security Sensor manuals
Popular Security Sensor manuals by other brands

resideo
resideo Lyric RCHW3610WF installation guide

LUXOMAT
LUXOMAT PD2N-LTMS-RR Installation and operating instruction

GE
GE 250-CO Installation sheet

Bircher Reglomat
Bircher Reglomat PrimeMotion C Translation of the original instructions

Aritech
Aritech RF-EV1012PI-K4 Installation sheet

DoCash
DoCash BIG Series user manual

Extronic
Extronic PD-22LF installation instructions

aldes
aldes Bahia Curve Assembly instructions

Helios
Helios E-Stop Series user guide

Omniguard
Omniguard 760 series Installation and operating service manual

Family Safety Products
Family Safety Products Siren Pro Series 3 HS71512 manual

SOR
SOR 1550 General instructions