Salvarani TeeJet 844-AB Owner's manual

Software versione v4.01
844-AB PROGRAMMING MANUAL

Software versione v4.01
Summary
Switching ON /OFF - User Programme 1
Operating functions in working stag 2
Special functions displayed in working stage 2
Operator parameters programming (= User Setup) 3
Programming and selection of the row distance 4
Visual alarms 5

1Software version v4.01
Switching ON/OFF
User Programme
Function Operativa/e action /s Initial reading Next reading
ON
ET083.01
1
1
2
2
3
3
G
ON
OFF
m
1234567891011 12
☞
1234567891011 12 1234567891011 12
3.18 I HABL
XX XXX 3.0
Versione
Software
Serie NR.
OFF
ET083.01
1
1
2
2
3
3
G
ON
OFF
m
1234567891011 12
ET083.01
1
1
2
2
3
3
G
ON
OFF
m
1234567891011 12
☞
1234567891011 12
OFF
5
2
1
☞
Pro
BAR L/Ha
Km/h Ha
1234567891011 12
200038
3.2 1255
User
programme
Page10
ET083.01
1
1
2
2
3
3
G
ON
OFF
m
1234567891011 12
☞
1234567891011 12 1234567891011 12
PRO I-1-I
user 3.0
x2
STANDARD FUNCTIONS TO ALL PROGRAMMES:
• Toreadandconrmthedierentparameterspress:
ET083.01
1
1
2
2
3
3
G
ON
OFF
m
1234567891011 12
.
• Tochangethevaluespres:
ET083.01
1
1
2
2
3
3
G
ON
OFF
m
1234567891011 12
,
ET083.01
1
1
2
2
3
3
G
ON
OFF
m
1234567891011 12
.
• Toreturntotheworkstageandquitprogramming,fromanywhere:pressthebuttonforatleast3
seconds
ET083.01
1
1
2
2
3
3
G
ON
OFF
m
1234567891011 12
.

2Software version v4.01
Operating functions in working stage
Special features displayed in working stage
For density = 1.00
(water)
Pressure
Pro
BAR L/Ha
Km/h Ha
1234567891011 12
200038
3.2 1255
Delivereddose
Required dose
Speed
Volume/Area
6 pre-dened
memories of
rows distan-
ce: selectable
values without
needing to stop
the work ☞ 1234567891011 12
I-1-I
3.0
☞ 1234567891011 12
I-2-I
3.25
☞ 1234567891011 12
I-6-I
4.50
Possibility of
increasing or
decreasing the
required dosa-
ge
Also in moving !
Easy way to quickly adjust the required dose temporarily:
Inautomaticmode:pressthebutton (or ),therequireddosewillincrease(ordecrease)by10%;press
thebuttons and simultaneouslytoreturntothestoredrequireddose.
Pro
BAR L/Ha
Km/h Ha
1234567891011 12
1005
3.5 1.034
☞
Pro
BAR L/Ha
Km/h Ha
1234567891011 12
1107
3.5 1.034
☞
Pro
BAR L/Ha
Km/h Ha
1234567891011 12
1209
3.5 1.034
☞
☞
&
Pro
BAR L/Ha
Km/h Ha
1234567891011 12
1105
3.5 1.034
Pro
BAR L/Ha
Km/h Ha
1234567891011 12
1005
3.5 1.034
☞
Pro
BAR L/Ha
Km/h Ha
1234567891011 12
903
3.5 1.034
☞
Pro
BAR L/Ha
Km/h Ha
1234567891011 12
802
3.5 1.034
☞
☞
&
Pro
BAR L/Ha
Km/h Ha
1234567891011 12
1005
3.5 1.034
Automatic swi-
tching o
Thecomputershutsdownautomaticallyifitdoesnotworkfor10minutes(toeconomizethedurationofthe
batteries)Itisalwaysbettertomove-withtheequipmentinastationaryposition-themainswitchdown-
OFF-

3Software version v4.01
Operator parameters programming (= User Setup)
How to do Action Temporary reading Final reading
Master switch
OFF
ET083.01
1
1
2
2
3
3
G
ON
OFF
m
1234567891011 12
☞
1234567891011 12 1234567891011 12
PRO I-1-I
user 3.0
x2
Parameters Display Description Remarks
1.
Memories from
1 to 12
Type-number
and nozzles
ow rates.
Pro
BAR L/Ha
Km/h Ha
1234567891011 12
6,55
3.6
Thearrowisashing:pressthebuttons
ET083.01
1
1
2
2
3
3
G
ON
OFF
m
1234567891011 12
and
ET083.01
1
1
2
2
3
3
G
ON
OFF
m
1234567891011 12
toselect
oneofthe12memories.Thevaluesofthesememorieshave
beenenteredintheManufacturer'sProgrammePage5.
L1 L
L1 L
R
R
+
2.
Selection of the
dose to deliver
Pro
BAR L/Ha
Km/h Ha
1234567891011 12
1209
3.6
L/Ha TheindexL/Haisashing:pressthebuttons
ET083.01
1
1
2
2
3
3
G
ON
OFF
m
1234567891011 12
and
ET083.01
1
1
2
2
3
3
G
ON
OFF
m
1234567891011 12
to
increaseordecreasethevalue(L/ha).
3.
Speed index
calculation : at
which pressu-
re?
Pro
BAR L/Ha
Km/h Ha
1234567891011 12
12.09
3.6
BAR
TheBarindexashes:pressthebuttons
ET083.01
1
1
2
2
3
3
G
ON
OFF
m
1234567891011 12
and
ET083.01
1
1
2
2
3
3
G
ON
OFF
m
1234567891011 12
to
increaseordecreasethevalue.Bykeepingtherequireddose,
itispossibletounderstandwhethertheworkingpressureis
correctaccordingtothespeedthatisindicatedandcalculated
directlybythecomputer.
4.
Pressure index
calculation : at
which speed?
Pro
BAR L/Ha
Km/h Ha
1234567891011 12
12.07
2.8 Km/h
TheKm/Hindexashes:pressthebuttons
ET083.01
1
1
2
2
3
3
G
ON
OFF
m
1234567891011 12
and
ET083.01
1
1
2
2
3
3
G
ON
OFF
m
1234567891011 12
to
increaseordecreasethevalue.Bykeepingtherequireddose,
itispossibletounderstandwhethertheforwardspeediscor-
rectaccordingtothepressurethatisindicatedandcalculated
directlybythecomputer,usefulforthepump.

4Software version v4.01
Programming and selection of the row distance
Programming Selection
☞
min.3 sec.
1
Pro
BAR L/Ha
Km/h Ha
1234567891011 12
I-1- 10.0
☞
2
Pro
BAR L/Ha
Km/h Ha
1234567891011 12
I-2- 16.0
☞
3
Pro
BAR L/Ha
Km/h Ha
1234567891011 12
I-3- 20.0
☞
4
Pro
BAR L/Ha
Km/h Ha
1234567891011 12
I-4-I 0.0
☞
5
Pro
BAR L/Ha
Km/h Ha
1234567891011 12
I-5-I 0.0
☞
6
Pro
BAR L/Ha
Km/h Ha
1234567891011 12
I-6-I 0.0
☞
To exit
one time
☞
One time
1
Pro
BAR L/Ha
Km/h Ha
1234567891011 12
I-1-I
10.0
☞
2
Pro
BAR L/Ha
Km/h Ha
1234567891011 12
I-2-I
16.0
☞
3
Pro
BAR L/Ha
Km/h Ha
1234567891011 12
I-3-I
20.0
☞
4
Pro
BAR L/Ha
Km/h Ha
1234567891011 12
I-4-I
10.0
☞
5
Pro
BAR L/Ha
Km/h Ha
1234567891011 12
I-5-I
16.0
☞
6
Pro
BAR L/Ha
Km/h Ha
1234567891011 12
I-6-I
16.0
☞
To exit
one time
ET083.01
1
1
2
2
3
3
G
ON
OFF
m
1234567891011 12
Remarks : to change the value, use the
ET083.01
1
1
2
2
3
3
G
ON
OFF
m
1234567891011 12
or
ET083.01
1
1
2
2
3
3
G
ON
OFF
m
1234567891011 12
but-
tons. If you do not want to activate the memory, leave
it at 0.0
Remarks : there are 6 available memories, that are not
visible unless actived with a value.

5Software version v4.01
Visual alarms
Type Display Description Displayed
problem
Warning signal
of the delivered
dose
Pro
BAR L/Ha
Km/h Ha
1234567891011 12
2.5
8.6 1034
Err Intheeventofadistributioncontrolproblem,thevalueorthe
indexlt/hastartstoash.Iftheerrordoesnotexceed10%,
onlytheindexlt'haisashing.If,howeveritexceeds10%,(for
morethan6seconds)theword“ERR”alsoappears.
Alarm
pressure
Pressure
Transducer
Pro
BAR L/Ha
Km/h Ha
1234567891011 12
8.6 1034
0.0Err "ERR"startstoashinsteadofthepressurevalue.Thisalarm
isonlyactiveifthetransducerisappliedtotheequipment.
Remark : In some circumstances, several alarms may appear at the same time

Software versione v4.01
viaM.Buonarroti,2
42028Poviglio(RE)-Italy
Tel+390522969177
Fax+390522960612
E-mail:[email protected]
Table of contents
Popular Control Unit manuals by other brands

Spirax Sarco
Spirax Sarco HM Series Installation and maintenance instructions

BERMAD
BERMAD 450-60 manual

Master
Master X60 EGO user manual

Hispacold
Hispacold Ecomaster Clima MH-012 user manual

Steamist
Steamist TSC-250T Installation and operating instructions

CONFLOW
CONFLOW RPX40 Installation and maintenance manual

Hydropa
Hydropa DS-11 Series operating manual

WEG
WEG SSW900-CETH-IP-N Installation, configuration and operations guide

Griswold
Griswold FlowCon EDP Installation and operation instruction

TLV
TLV PowerDyne HR80A instruction manual

DMP Electronics
DMP Electronics 734 Installation and programming guide

Solid State Logic
Solid State Logic SSL G Series user guide