Samlexpower Evolution Series User manual

Remote Control for
EvolutionTM Series
Inverter/ Charger
Model: EVO-RC-PLUS
Please read this
manual BEFORE
operating.
Owner's
Manual
NOTE: REMOTE CONTROL MODEL NO. EVO-RC-PLUS IS OPTIONAL AND IS REQUIRED TO BE ORDERED SEPARATELY.

EVO-RC OWNER'S MANUAL | Index
SECTION 1
Introduction and Layout........................................................ 3
SECTION 2
Installation ........................................................................... 6
SECTION 3
Operation .......................................................................... 8
SECTION 4
Parameter Setup ................................................................ 27
SECTION 5
SD Card ......................................................................... 77
SECTION 6
Monitoring of Operation Using LED and Buzzer ................ 83
SECTION 7
Fault Messages and Troubleshooting Guide ....................... 84
SECTION 8
Specications ..................................................................... 87
SECTION 9
Warranty ......................................................................... 88
Disclaimer of Liability
UNLESS SPECIFICALLY AGREED TO IN WRITING, SAMLEX AMERICA INC:
1. MAKES NO WARRANTY AS TO THE ACCURACY, SUFFICIENCY OR SUITABILITY OF ANY TECHNICAL OR OTHER INFORMATION PRO-
VIDED IN ITS MANUALS OR OTHER DOCUMENTATION.
2. ASSUMES NO RESPONSIBILITY OR LIABILITY FOR LOSSES, DAMAGES, COSTS OR EXPENSES, WHETHER SPECIAL, DIRECT, INDIRECT,
CONSEQUENTIAL OR INCIDENTAL, WHICH MIGHT ARISE OUT OF THE USE OF SUCH INFORMATION. THE USE OF ANY SUCH INFOR-
MATION WILL BE ENTIRELY AT THE USERS RISK.
Samlex America Inc. reserves the right to revise this document and to periodically make changes to the content
hereof without obligation or organization of such revisions or changes.
Copyright Notice/Notice of Copyright
Copyright © 2016 by Samlex America Inc. All rights reserved. Permission to copy, distribute and /or modify this docu-
ment is prohibited without express written permission by Samlex America Inc.

SAMLEX AMERICA INC. | 3
1.0 INTRODUCTION
The EVO-RC-PLUS Remote Control allows you to monitor and customize the operating pa-
rameters of Samlex EVOTM Inverter/Chargers Models EVO-1212F / 1212F-HW, 1224F / 1224F-
HW, 2212, 2224, 3012 and 4024. Layout is shown in Fig 1 below.
It has its own internal Real Time Clock and Super Capacitor Type of Battery for clock operation.
1.1 LAYOUT AND DIMENSIONS
Fault
160
114.2
146
4.2
100
Fig 1.1 Layout and dimensions of
Remote Control Model EVO-RC PLUS
9
5
3
4
678
1
10 11
2
128
32.5
35.5
SECTION 1 | Introduction and Layout
1. LCD Screen:
- 4 rows of 20 characters each
- Blue screen with white
characters
2. ON/OFF Key
3. Blue LED “Status”
4. Red LED “Alarm”
5. Navigation Key “Back”
6. Navigation Key “Up”
7. Navigation Key “Down”
8. Navigation Key “Enter”
9. SD Card Slot – FAT16/32
format, up to 16 GB
10. RJ-45 Jack
Pin # Signal
112V
212V
3ON/OFF
4D+
5D-
6NC
7GND
8GND
11. RJ-12 Jack
Pin # Signal
1NC
2GND
3D-
4D+
512
6ON/OFF
1.2 CONNECTING CABLE
Details of connecting cable provided with the Remote Control are as follows:
• Length: 10m / 33ft
• No of conductors: 8
• Modular Plug: 8P8C, RJ-45
• Plug interconnection: Straight (See Pinout at Fig 1.2)
12345678
1 2 3 4 5 6
12345678
1 2 3 4 5 6
View - Looking into the Jack)
View - Looking into the Jack)

4 | SAMLEX AMERICA INC.
SECTION 1 | Introduction and Layout
1.3 PINOUT DIAGRAMS & INTERNAL INTERCONNECTION OF RJ-45 &
RJ-12 JACKS
RJ-45 Jack (10, Fig 1.1) and RJ-12 Jack (11, Fig 1.1) are internally connected as pinout at Fig 1.3.
RJ-45
Pin #
Signal
112V
212V
3ON/OFF
4D+
5D-
6NC
7GND
8GND
Pin Out of
Plug - End 1
RJ-45
Pin #
Signal
112V
212V
3ON/OFF
4D+
5D-
6NC
7GND
8GND
Pin Out of
Plug - End 2
Top view of Plug -
Locking Tab facing down
Front view of Plug -
Locking Tab
facing up
Fig 1.2 Pin Out of Plugs for 8P8C, RJ-45 Connecting Cable
8P 8C, RJ-45 Modular Plug
RJ-12
Pin #
Signal
6ON/OFF
512V
4D+
3D-
2GND
1NC
RJ-45
Pin #
Signal
112V
212V
3ON/OFF
4D+
5D-
6NC
7GND
8GND
Fig 1.3 Pinout and internal interconnections of RJ-45
and RJ-12 (6P6C) Jacks on EVO-RC-PLUS
Straight
Connection
12345678 1 2 3 4 5 6
12345678 1 2 3 4 5 6
RJ-12 (6P6C) Jack RJ-45 (8P8C) Jack

4 | SAMLEX AMERICA INC. SAMLEX AMERICA INC. | 5
SECTION 1 | Introduction and Layout
“B-6P4C”“A”
1 2 3 4 5 6 1 2 3 4 5 6
Black
Red
Green
Yellow
6P4C Modular Plug
(Locking Tab
Facing Down)
NC Not connected
6P4C Modular Plug
(Locking Tab
Facing Down)
NC 1
GND 2
D– 3
D+ 4
+12V 5
NC 6
1 NC
2 +12V
3 D+
4 D–
5 GND
6 NC
Fig 1.4 RJ-11 (6P4C) cross connected cable
“B-8P8C”
“A”
1 2 3 4 5 6 1 2 3 4 5 6 7 8
Black
Red
Green
Yellow
Black
Red
Green
Yellow
NC Not connected
NC 1
GND 2
D– 3
D+ 4
+12V 5
NC 6
1 NC
2 +12V
3 NC
4 D+
5 D–
6 NC
7 GND
8 NC
* Rewired 8P8C Plug
(Locking tab facing down)
* 6P4C Plug “B-6P4C” of
Fig 1.4 has been cut and
replaced with 8P8C plug
and rewired as shown
Connect to RJ-45 Jack
marked “Remote Control”
on EVO-2212/3012/2224/4024
or EVO-1212F/1212F-HW/
1224F/1224F-HW
Existing 6P6C
Modular Plug
(Locking tab
facing down)
[Fig 1.4]
Connect to
6P6C Jack on
EVO-RC-PLUS
Fig 1.5 RJ-11 (6P4C) cable [Fig 1.4) rewired on one end with RJ-45 (8P8C) Modular Plug

6 | SAMLEX AMERICA INC.
SECTION 2 | Installation
2.0 INSTALLATION GUIDELINES
EVO-RC-PLUS is provided with 10M/33ft, RJ-45 data cable (straight wired). Check the proposed
routing distance of the wire and use longer wire, if necessary.
• Flush mounting of the Remote requires appropriate cut-out in the wall/panel - See Fig 2.1.
Full scale installation Template for panel cut-out and pilot holes for mounting screws is also
provided along with the unit. Take necessary precautions to ensure any wiring/plumbing run-
ning behind the wall/panel is not damaged.
• Route the wire to ensure there are no kinks.
• Use appropriate grommets when the wire is passed through holes in studs/partitions to
prevent damage to insulation.
2.1 TOOLS REQUIRED
Following tools are recommended:
• Phillips head screwdriver • Level • Hand Drill
• Knife/Saw • Pencil • Drill Bit (2mm / 5/64")
EVO-RC-PLUS Installation Template
100 mm / 3.94 in
4.2 mm / 0.17 in
114.2 mm / 4.5 in
95 mm / 3.74 in
131 mm / 5.16 in
146 mm / 5.75 in
160 mm / 6.3 in
Cut the wall / panel along the dotted
line with a jig saw.
This will create a pocket in the wall / panel
for ush mounting the EVO-RC-PLUS.
13 mm / 0.51 in
WALL
Thickness of wall where
mounted should be up
to 13 mm / 0.51 in (see below).
Wall thickness
should be up to
13 mm / 0.51 in.
BOTTOM VIEW
Flush mounting the EVO-RC-PLUS
on the wall with 4 pcs of No. 6 x 5/8”,
Self-Tapping, Flat Head Screws.
A to D: 4 pilot holes, 2mm (5/64") diameter for
accepting No. 6 x 5/7", Self Tapping,
Flat Head Screws.
A
C D
B
Fig 2.1 EVO-RC-PLUS Remote installation details
2.2 FLUSH MOUNT INSTALLATION
To ush mount, the wall opening must have at least 2” (5 cm) depth to make room for the
remote and cable. Also, the thickness of wall/panel board at the place of mounting should not be
more than 13 mm to ensure that the RJ-45 / RJ-12 Jack openings are not obstructed (see Fig. 2.3).

6 | SAMLEX AMERICA INC. SAMLEX AMERICA INC. | 7
SECTION 2 | Installation
1. Cut an opening in the wall using the supplied Installation Template (based on Fig 2.1).
2. Drill four pilot holes (use 2mm / 5/64" diameter drill bit) for 4 screw (Self Taping, Flat Head
No. 6 x 5/8" long) that will attach the remote to the wall (refer to Fig. 2.1 for hole loca-
tions and dimensions).
3. Route one end of the cable through wall opening to the EVOTM Inverter/Charger, and then
plug it into the RJ-45 Remote Control Jack port on the EVOTM Inverter/Charger
4. Take the other end of the remote cable and plug it into the RJ-45 / RJ-12 Jack at the back
of the EVO-RC-PLUS (Fig. 2.3).
5. Check the remote display to ensure the Power-up Self Test initiates.
6. If the self test is successful, secure the EVO-RC-PLUS to the wall using the four screws (Fig. 2.2).
Flush mounting the EVO-RC-PLUS on the wall with 4 screws:
No. 6 x 5/8", Self Tapping, Flat Head.
Fig 2.2 EVO-RC-PLUS Flush Mounting
The thickness of the wall/panel board at the place of mounting should not be
more than 13 mm to ensure that the RJ-45 / RJ-12 jack openings are not obstructed.
Fig 2.3 Wall/Panel Thickness

8 | SAMLEX AMERICA INC.
SECTION 3 | Operation
3.0 GENERAL INFORMATION
EVO-RC-PLUS Remote Control provides the user with the ability to monitor the operation and
also to modify EVOTM Inverter/Charger’s operating parameters. The default settings in EVOTM
Inverter/Charger are adequate for some installations but may have to be modied for others.
This Section provides details on the remote functions, status and menu maps and displays, fault
messages and parameter settings.
3.1 NAVIGATING THE REMOTE
Please refer to the layout at Fig. 1.1.
• LCD Display (1) – The 4-line (20 characters each) LCD display shows status and information
for the EVOTM Inverter/Charger. All Setup Menus and faults also appear on the LCD display.
• ON/OFF Key (2) – The On/Off Key is used for switching on/ switching off the EVOTM
Inverter/Charger and also to enter/exit Standby Mode.
• Navigation Keys (5, 6, 7, 8) – These four keys allow simple access to Menu Item that
assists conguring, monitoring, and troubleshooting the EVOTM Inverter/Charger.
o Navigation Key Functions:
Back – Return to previous selection
Up – Move from lower to upper Menu Screen in various Menu Maps e.g. Fig 3.1 (a)
Down – Move from upper to lower Menu Screen in various Menu Maps
e.g. Fig 3.1(a)
Enter – Select/write a particular value or option.
• Status – Blue LED indicator for indicating operating status (see details at Section 6, Table 6.1).
• Fault – Red LED indicator for indicating fault conditions (see details at Section 6, Table 6.1).
• SD Card slot – This slot supports SD memory card (up to 16GB, FAT16/32). The SD Card
is used for data logging of EVOTM Inverter/Charger’s operational statistics and events and
saving and uploading of programmed parameters. See Section 5: SD Card.

8 | SAMLEX AMERICA INC. SAMLEX AMERICA INC. | 9
SECTION 3 | Operation
3.2 POWER ON / POWER OFF
i
INFO
a) Minimum battery voltage required for initiating manual switching ON of the unit
is as follows:
• 12V units ----- Higher than 9V
• 24V units ---- Higher than 18V
b) Please note that this unit is designed to POWER ON AUTOMATICALLY if (i) AC voltage of
70V ± 5 VAC is available at the AC Input Terminals and (ii) DC input voltage is > 12V for 12V
versions of EVOTM and >24V for 24V versions of EVOTM. If the AC input voltage and frequency
are within the programmed limits, the unit will automatically operate in “Charging Mode”.
If the AC input voltage and frequency are not within the programmed limits, the unit will
operate in “Inverting" Mode. Further, as long as AC input voltage > 70 ± 5 VAC is present, the
unit CANNOT BE POWERED OFF using the ON / OFF Button on the front panel of the unit or
on the Remote Control EVO-RC-PLUS. Switch OFF the AC input rst if the unit is required to
be powered off. However, if the unit is in “Fault Mode”, it will be possible to power OFF the
unit with the help of the ON/OFF Push Button.
c) Before proceeding, conrm that the unit is NOT in "Standby" Mode. If it is in "Standby
Mode", the "Status" LED (3, Fig 1.1) will ash once every 5 sec and the LED screen will
display one of the "Standby Mode" Screens show in Figs 3.1(a) / 3.1(b).
Press the On/Off Push Botton (2, Fig 1.1) on the EVO-RC-PLUS to exit the "Standby Mode"
to the current operating mode. Refer to Section 3.4 for more details on "Standby Mode".
3.2.1 Power ON - AC INPUT IS NOT PRESENT
The sequence given below is applicable when there is no AC input and the unit is switched ON.
Press On/Off Key and hold for 2 second to turn the EVOTM Inverter/Charger ON.
P O W E R O N . . .
Screen (a)
S E A R C H I N G I D . . . 1
Screen (b)
E V O - 1 2 1 2 F V E R X . X X
I N V E R T E R / C H A R G E R
Screen (c)
E V O - 1 2 1 2 F I n v e r t i n g
A C o u t p u t : 1 2 0 . 0 V
< 0 . 1 A
6 0 . 0 0 H z
Screen (d)
When the EVOTM Inverter/Charger is OFF and the On/Off
Key is pressed and held, the LCD screen shows “POWER
ON…" [Screen (a)] and the Status LED ashes 3 times. On/
Off key may be released now. After 2 seconds, EVO-RC-
PLUS starts to search for the communication ID of the EVOTM
Inverter/Charger it is attached to. The LCD screen shows
“SEARCHING ID …” [Screen (b)] and the ID number which
is found is shown at the end of the line. When the default
ID of “1” is found, the display will then show the EVOTM
Inverter/Charger Model No. and rmware version (3 digit
number X.XX) [Screen (c)]. The screen will then change to
the Inverting Mode Screen [Screen (d)].
NOTE: If the EVOTM Inverter/Charger has AC input
voltage over 70 ± 5 VAC available at the Grid/
Generator inputs, the Power OFF function is disabled
and the unit will remain in the ON condition if the
power off sequence is attempted. The AC input must
be removed before the unit can be powered OFF.

10 | SAMLEX AMERICA INC.
SECTION 3 | Operation
3.2.2 Power OFF - AC INPUT IS NOT PRESENT
The sequence given below is applicable when no AC input is present and the unit is powered OFF.
Press On/Off Key and hold for 5 seconds to turn OFF the EVOTM Inverter/Charger.
P O W E R O F F !
When EVOTM Inverter Charger is ON and the On/Off key is
pressed and held for minimum of 5 seconds, the LCD screen
will show “POWER OFF !” and both the Status and Alarm
LEDs will turn ON. Now release the On/Off key (please note
that Power Off sequence will be completed and display
“POWER OFF !” will disappear only when the On/Off
key is released).
NOTE: If the EVOTM Inverter/Charger has AC input
voltage over 70 ± 5 VAC available at the Grid/
Generator inputs, the Power OFF function is disabled
and the unit will remain in the ON condition if the
power off sequence is attempted. The AC input must
be removed before the unit can be powered OFF.
3.3 DATE AND TIME SETUP
Set date and time as per procedure given at Section 4.9: “Group 6 Parameter Setup: Time Setting”.
3.4 STANDBY MODE
When the EVOTM is in Standby Mode, inverting or charging / AC pass through will be suspended.
i
INFO
Standby Mode may be used to temporary halt normal operation of the Inverter/Char-
ger without switching OFF the unit completely.
For the Standby Mode to be switched ON, the EVOTM should be in ON condition and should be
operating in one of the 4 Operating Modes – “Inverting” or “Charging”, “Power Saving” or
"Online" (See Fig 3.1). When Standby Mode is switched ON, the EVOTM will exit its Operating
Mode i.e. inverting or charging / AC pass through will be suspended.
Standby Mode is toggled between ON and OFF conditions as follows:
• By momentary pressing (0.1 sec) of ON/OFF Push Key (2, Fig 1.1), OR
• By momentary pressing (0.1 sec) of ON/OFF Push Button on the front panel of the unit
(11, Fig 2.1 in the Owner’s Manual for EvolutionTM Series Inverter/Charger Models).
When the EVOTM is in “Standby Mode”, operational status will be displayed as follows:
• On the Remote Control EVO-RC-PLUS:
- Blue LED marked “Status” (3, Fig 1.1) will blink once every 5 sec. Red LED marked
“FAULT” (4, Fig 1.1) will be off
- The LCD will display "Standby" Mode screens as follows:
(i) For EVO-1212F/1212F-HW/1214F/1224F-HW: As per "Standby" Mode Menu Map
at Fig 3.2(a).
(ii) For EVO-2212/3012/2224/4024: As per "Standby" Mode Menu Map at Fig 3.2(b).
- No buzzer

10 | SAMLEX AMERICA INC. SAMLEX AMERICA INC. | 11
SECTION 3 | Operation
• On the front panel of EVOTM:
- No LED display. LED marked “ON” and Red LED marked “FAULT” will both be OFF.
- No buzzer
- LED marked "ON" (12, Fig 2.1 in the Owner's Manual for EvolutionTM Series
Inverter/Charger) will blink once every 5 sec.
- Red LED marked "FAULT" (13, Fig 2.1) in the Owner's Manual for EvolutionTM Series
Inverter/Charger) will be OFF.
- No buzzer
3.5. FAULT CLEARING
If any fault occurs, the LCD screen will display the Fault Message and the Red LED “Fault” will
be lighted. Remove cause of the fault. The unit will remain in Fault Mode unless it is cleared.
A short press (0.1 seconds) of the On/Off key will clear the Fault Message and the EVOTM Inverter/
Charger will return to the operational status (if the fault condition no longer exists). Refer to
section 7 on “Fault Messages”.
3.6 OPERATING MODES AND ASSOCIATED LCD DISPLAY SCREENS
3.6.1 General Information
When the unit is operating normally, the LCD Screen will display the name of the Operating
Mode and values of various associated operating parameters. As all the operating parameters
associated with a particular Operating Mode cannot be displayed in one screen, multiple
screens are available that can be accessed using the Up and Down Keys. For ease of navigating
through the various screens, all the screens covering a particular Operating Mode are shown and
arranged in a Menu Map – for example, see Menu Map for Inverting Mode at Figs 3.2(a) and
3.2(b). Table 3.1 shows the names of the Operating Modes and the Fig Nos. of the associated
Menu Maps.
Typical Operating Mode Display Screen is shown in Fig 3.0 [Copy of Screen 1 of Inverting Mode
Menu Map at Fig 3.2(a)]. There are 4 lines of display (up to 20 characters per line). The 1st line
shows the Model No on the left side and the Operating Mode on the right side. The 2nd, 3rd and
the 4th lines display various operating parameters and their values.
E V O - 1 2 1 2 F I n v e r t i n g
A C o u t p u t : 1 2 0 . 0 V
< 0 . 1 A
6 0 . 0 0 H z
Fig 3.0 Typical Operating Mode Display Screen
[Screen No. 1 of Inverting Mode Menu Map at Fig 3.2(a)]

12 | SAMLEX AMERICA INC.
SECTION 3 | Operation
Table 3.1 Operating Modes and Associated LCD Display Screens
Operating
Mode
Display Description
Operating Mode
Screen Menu Map
Models
EVO-1212F /
1212F HW / 1224F /
1224F-HW
Models
EVO-2212 / 3012 /
2224 / 4024
Standby Standby Mode: No output, No AC
bypass, No Charging
Fig 3.1(a),
Section 3.6.2.1
Fig 3.1 (b),
Section 3.6.2.2
Inverting Unit is operating as an inverter Fig 3.2(a),
Section 3.6.3.1
Fig 3.2(b),
Section 3.6.3.2
Charging Unit is operating as a battery charger
and passing through the AC input to
the loads
Fig 3.3(a),
Section 3.6.4.1
Fig 3.3(b),
Section 3.6.4.2
PowerSave Unit is in Power Saving Mode Fig 3.4(a),
Section 3.6.5.1
Fig 3.4(a),
Section 3.6.5.2
Online Unit is in On Line Mode Fig 3.5, Section 3.6.6
Chrg Only Under "ONLINE MODE" only (Option
2=Charger Only). Provides charging and
pass through when the AC input is avail-
able. No inverting when the AC input is
not available.
Fig 3.6(a),
Section 3.6.7.1
Fig 3.6(b),
Section 3.6.7.2
Charger Off
by BMS
Applicable when BATTERY TYPE
Option 1=Lithium is selected. This
mode is activated when the Lithium
Battery Management System (BMS)
sends command to EVOTM (contact
closure signal) to stop charging to
prevent battery over voltage or over
temperature.
Fig 3.7, Section 3.6.8
Inverter stop
by BMS
Applicable when BATTERY TYPE Op-
tion 1=Lithium is selected. This mode
is activated when the Lithium Battery
Management System (BMS) sends com-
mand to EVOTM (contact closure signal) to
stop inverting to prevent deep discharge
of the battery.
Fig 3.8, Section 3.6.9

12 | SAMLEX AMERICA INC. SAMLEX AMERICA INC. | 13
SECTION 3 | Operation
3.6.2 Menu Map for Standby Mode Screens
Menu Maps for the Operating Mode Screens for the Standby Mode are shown as follows:
Section 3.6.2.1: Fig 3.1(a) for Models EVO-1212F / 1212F-HW / 1224F / 1224F-HW
(Model No. shown in the screens is EVO-1212F)
Section 3.6.2.2: Fig 3.1(b) for Models EVO-2212 / 3012 / 2224 / 4024 (Model No. shown in
the screens is EVO-3012)
3.6.2.1 Menu Map for Standby Mode Screens for EVO-1212F / 1212F-HW /
1224F / 1224F-HW
NOTES:
1. The 1st line of the display screen shows
Model No. on the left and the Operating Mode
"Standby" on the right.
2. The 2nd, 3rd and the 4th lines show various
operating parameters and their values.
3. Use Up ñand Down òKeys to navigate to the
desired screen.
Up Key
Down Key
E V O - 1 2 1 2 F S t a n d b y
A C o u t p u t : 0 . 0 V
< 0 . 1 A
0 . 0 0 H z
Screen
No. 1
E V O - 1 2 1 2 F S t a n d b y
A C o u t p u t : < 1 2 W
< 1 2 V A
P F = 0 . 0 0 0
Screen
No. 2
E V O - 1 2 1 2 F S t a n d b y
A C i n p u t : 1 2 0 . 0 V
< 0 . 1 0 A
6 0 . 0 0 H z
Screen
No. 3
E V O - 1 2 1 2 F S t a n d b y
B a t t e r y : 1 2 . 0 0 V
0 . 0 A
E x t e r n a l : 0 . 0 A
Screen
No. 5
E V O - 1 2 1 2 F S t a n d b y
B a t t e r y 2 5 . 0 C
H e a t s i n k 2 5 . 0 C
T r a n s f o r m e r 2 5 . 0 C
Screen
No. 6
E V O - 1 2 1 2 F S t a n d b y
E V O V e r : x . x x I D = 1
R C V e r : x . x x
2 0 1 7 / 0 4 / 2 1 1 5 : 0 0
Screen
No. 7
ð ð ð ð
ð ð ð ð
ð
ð
E V O - 1 2 1 2 F S t a n d b y
A C i n p u t : < 1 2 W
< 1 2 V A
P F = 0 . 0 0 0
Screen
No. 4
ð
ð
Fig 3.1(a) Menu Map for Standby Mode Screens for Models EVO-1212F /
EVO-1212F-HW / 1224F / 1224F-HW (Model No. shown is EVO-1212F)

14 | SAMLEX AMERICA INC.
SECTION 3 | Operation
3.6.2.2 Menu Map for Standby Mode Screens for EVO-2212 / 3012 / 2224 / 4024
NOTES:
1. The 1st line of the display screen shows
Model No. on the left and the Operating Mode
"Standby" on the right.
2. The 2nd, 3rd and the 4th lines show various
operating parameters and their values.
3. Use Up ñand Down òKeys to navigate to the
desired screen.
Up Key
Down Key
E V O - 3 0 1 2 S t a n d b y
A C o u t p u t : 0 . 0 V
< 0 . 1 A
0 . 0 0 H z
Screen
No. 1
E V O - 3 0 1 2 S t a n d b y
A C o u t p u t : < 1 2 W
< 1 2 V A
P F = 0 . 0 0 0
Screen
No. 2
E V O - 3 0 1 2 S t a n d b y
G r i d : 1 2 0 . 0 V
< 0 . 1 0 A
6 0 . 0 0 H z
Screen
No. 3
E V O - 3 0 1 2 S t a n d b y
G E N : 1 2 0 . 0 V
< 0 . 1 0 A
P F = 6 0 . 0 0 H z
Screen
No. 5
E V O - 3 0 1 2 S t a n d b y
G E N : < 1 2 W
< 1 2 V A
P F = 0 . 0 0 0
Screen
No. 6
E V O - 3 0 1 2 S t a n d b y
B a t t e r y : 1 2 0 . 0 V
0 . 0 A
E x t e r n a l : 0 . 0 A
E V O - 3 0 1 2 S t a n d b y
B a t t e r y 2 5 . 0 C
H e a t s i n k 2 5 . 0 C
T r a n s f o r m e r 2 5 . 0 C
E V O - 3 0 1 2 S t a n d b y
E V O V e r : x . x x I D = 1
R C V e r : x . x x
2 0 1 7 / 0 4 / 2 1 1 5 : 0 0
Screen
No. 7
Screen
No. 8
Screen
No. 9
ð ð ð ð
ð ð ð ð
ð ð
ð ð
ð
ð
E V O - 1 2 1 2 F S t a n d b y
G r i d : < 1 2 W
< 1 2 V A
P F = 0 . 0 0 0
Screen
No. 4
ð
ð
Fig 3.1(b) Menu Map for Standby Mode Screens for
Models EVO-2212 / 3012 / 2224 / 4024

14 | SAMLEX AMERICA INC. SAMLEX AMERICA INC. | 15
SECTION 3 | Operation
3.6.3 Menu Map for Inverting Mode Screens
Menu Maps for the Operating Mode Screens for the "Inverting" Mode are shown as follows:
Section 3.6.3.1: Fig 3.2(a) for Models EVO-1212F / 1212F-HW / 1224F / 1224F-HW (Model
No. shown in the screens is EVO-1212F).
Section 3.6.3.2: Fig 3.2(b) for Models EVO-2212 / 3012 / 2224 / 4024 (Model No. shown
in the screens is EVO-3012).
3.6.3.1 Menu Map for Inverting Mode Screens for Models EVO-1212F /
1212F-HW / 1224F / 1224F-HW
NOTES:
1. The 1st line of the display screen shows Model
No. on the left and the Operating Mode
“Inverting” on the right
2. The 2nd, 3rd and the 4th lines show various
operating parameters and their values
3. Use Up ñand Down òKeys to navigate to the
desired screen.
Up Key
Down Key
E V O - 1 2 1 2 F I n v e r t i n g
A C O u t p u t : 1 2 0 . 0 V
< 0 . 1 0 A
6 0 . 0 0 H z
Screen
No. 1
E V O - 1 2 1 2 F I n v e r t i n g
A C O u t p u t : < 1 2 W
< 1 2 V A
P F = 0 . 0 0 0
Screen
No. 2
E V O - 1 2 1 2 F I n v e r t i n g
A C i n p u t : 1 2 0 . 0 V
< 0 . 1 0 A
6 0 . 0 0 H z
Screen
No. 3
E V O - 1 2 1 2 F I n v e r t i n g
B a t t e r y : 1 2 . 0 0 V
0 . 0 A
E x t e r n a l : 0 . 0 A
Screen
No. 5
E V O - 1 2 1 2 F I n v e r t i n g
B a t t e r y 2 5 . 0 C
H e a t s i n k 2 5 . 0 C
T r a n s f o r m e r 2 5 . 0 C
Screen
No. 6
E V O - 1 2 1 2 F I n v e r t i n g
E V O V e r : x . x x I D = 1
R C V e r : x . x x
2 0 1 7 / 0 4 / 2 1 1 5 : 0 0
Screen
No. 7
ð ð ð ð
ð ð ð ð
ð
ð
E V O - 1 2 1 2 F I n v e r t i n g
A C i n p u t : < 1 2 W
< 1 2 V A
P F = 0 . 0 0 0
Screen
No. 4
ð
ð
Fig 3.2(a) Menu Map for Inverting Mode Screens for Models EVO-1212F /
1212F-H / 1224F / 1224F-HW (Model No. Shown is EVO-1212F)

16 | SAMLEX AMERICA INC.
SECTION 3 | Operation
3.6.3.2 Menu Map for Inverting Mode Screens for Models EVO-2212 / 3012 /
2224 / 4024
NOTES:
1. The 1st line of the display screen shows Model
No. on the left and the Operating Mode
“Inverting” on the right
2. The 2nd, 3rd and the 4th lines show various
operating parameters and their values
3. Use Up ñand Down òKeys to navigate to the
desired screen.
Up Key
Down Key
E V O - 3 0 1 2 I n v e r t i n g
O u t p u t : 1 2 0 . 0 V
< 0 . 1 0 A
6 0 . 0 0 H z
Screen
No. 1
E V O - 3 0 1 2 I n v e r t i n g
O u t p u t : < 1 2 W
< 1 2 V A
P F = 0 . 0 0 0
Screen
No. 2
E V O - 3 0 1 2 I n v e r t i n g
G r i d : 1 2 0 . 0 V
< 0 . 1 0 A
6 0 . 0 0 H z
Screen
No. 3
E V O - 3 0 1 2 I n v e r t i n g
G E N : 1 2 0 . 0 V
< 0 . 1 0 A
P F = 6 0 . 0 0 H z
Screen
No. 5
E V O - 3 0 1 2 I n v e r t i n g
< 1 2 W
< 1 2 V A
P F = 0 . 0 0 0
Screen
No. 6
E V O - 3 0 1 2 I n v e r t i n g
B a t t e r y : 1 2 . 0 0 V
0 . 0 A
E x t e r n a l : 0 . 0 A
Screen
No. 7
ð ð ð ð
ð ð ð ð
ð
ð
E V O - 3 0 1 2 I n v e r t i n g
G r i d : < 1 2 W
< 1 2 V A
P F = 0 . 0 0 0
Screen
No. 4
ð
ð
Fig 3.2(b) Menu Map for Inverting Mode Screens for Models
EVO-2212 / 3012 / 2224 / 4024 (Model No. shown is EVO-3012)
E V O - 3 0 1 2 I n v e r t i n g
B a t t e r y C
H e a t s i n k C
T r a n s f o r m e r C
E V O - 3 0 1 2 I n v e r t i n g
E V O V e r : x . x x 1 0 = 1
R C V e r : x . x x
2 0 1 7 / 0 4 / 2 1 1 5 : 0 0
ð ð
ðð
Screen
No. 8
Screen
No. 9

16 | SAMLEX AMERICA INC. SAMLEX AMERICA INC. | 17
SECTION 3 | Operation
3.6.4 Menu Map for Charging Mode Screens
Menu Map for the Operating Mode Screens for the "Charging" Mode are shown as follows:
Section 3.6.4.1: Fig 3.3(a) for Models EVO-1212F / 1212F-HW / 1224F / 1224F-HW
(Model No. shown in the screens is EVO-1212F).
Section 3.6.4.2: Fig 3.3(b) for Models EVO-2212 / 3012 / 2224 / 4024 (Model No. shown
in the screens is EVO-3012).
3.6.4.1 Menu Map for Charging Mode Screens for Models EVO-1212F /
1212F-HW / 1224F / 1224F-HW
Fig 3.3(a) Menu Map for Charging Mode Screens for Models EVO-1212F /
1212F-HW / 1224F / 1224F-HW (Model No. shown is EVO-1212F)
NOTES:
1. The 1st line of the display screen shows
Model No. on the left and the Operating Mode
“Charging” on the right
2. The 2nd line shows the Charging Stage preceded
by a numeral “0, or 1, or 2, or 3, or 4” or letter
“E” that is a code for specic type of Charg-
ing Prole (see Table 3.2). The 2nd line may also
show message “Charger off by BMS” when
parameter [Battery Type] is set for [1=Lithium].
See Section 3.6.8 and Fig 3.7 for details.
3. The 3rd and the 4th lines show various operating
parameters and their values
4. Use Up ñand Down òKeys to navigate to the
desired screen.
Up Key
Down Key
E V O - 1 2 1 2 F C h a r g i n g
0 - B u l k S t a g e
B a t t : 1 2 . 0 0 V 2 0 . 0 A
E x t e r n a l : 0 . 0 A
Screen
No. 1
E V O - 1 2 1 2 F C h a r g i n g
0 - B u l k S t a g e
A C i n : 1 2 0 . 0 V 1 0 . 0 0 A
6 0 . 0 0 H z
Screen
No. 2
E V O - 1 2 1 2 F C h a r g i n g
0 - B u l k S t a g e
A C i n : 1 2 0 0 V A 1 2 0 0 W
P F : 1 . 0 0
Screen
No. 3
E V O - 1 2 1 2 F C h a r g i n g
0 - B u l k S t a g e
A C o u t : 1 2 0 0 V A 1 2 0 0 W
P F : 1 . 0 0
Screen
No. 5
E V O - 1 2 1 2 F C h a r g i n g
B a t t e r y 2 5 . 0 C
H e a t s i n k 2 5 . 0 C
T r a n s f o r m e r 2 5 . 0 C
Screen
No. 6
E V O - 1 2 1 2 F C h a r g i n g
E V O V e r : x . x x I D = 1
R C V e r : x . x x
2 0 1 7 / 0 4 / 2 1 1 5 : 0 0
Screen
No. 7
ð ð ð ð
ð ð ð ð
ð
ð
E V O - 1 2 1 2 F C h a r g i n g
0 - B u l k S t a g e
A C o u t : 1 2 0 . 0 V 1 0 . 0 0 A
6 0 . 0 0 H z
Screen
No. 4
ð
ð

18 | SAMLEX AMERICA INC.
SECTION 3 | Operation
3.6.4.2 Menu Map for Charging Mode Screens for Models EVO-2212 / 3012 /
2224 / 4024
Fig 3.3(b) Menu Map for Charging Mode Screens for Models
EVO-2212 / 3012 / 2224 / 4024 (Model No. shown is EVO-3012)
NOTES:
1. The 1st line of the display screen shows
Model No. on the left and the Operating Mode
“Charging” on the right
2. The 2nd line shows the Charging Stage preceded
by a numeral “0, or 1, or 2, or 3, or 4” or letter
“E” that is a code for specic type of Charg-
ing Prole (see Table 3.2). The 2nd line may also
show message “Charger off by BMS” when
parameter [Battery Type] is set for [1=Lithium].
See Section 3.6.8 and Fig 3.7 for details.
3. The 3rd and the 4th lines show various operating
parameters and their values
4. Use Up ñand Down òKeys to navigate to the
desired screen.
Up Key
Down Key
E V O - 3 0 1 2 C h a r g i n g
0 - B u l k S t a g e
B a t t : 1 2 . 0 0 V 2 0 . 0 A
E x t e r n a l : 0 . 0 A
Screen
No. 1
E V O - 3 0 1 2 C h a r g i n g
0 - B u l k S t a g e
A C i n : 1 2 0 . 0 V 1 0 . 0 0 A
6 0 . 0 0 H z
Screen
No. 2
E V O - 3 0 1 2 C h a r g i n g
0 - B u l k S t a g e
G r i d : 1 2 0 0 V A 1 2 0 0 W
P F : 1 . 0 0
Screen
No. 3
E V O - 3 0 1 2 C h a r g i n g
0 - B u l k S t a g e
A C o u t : 1 2 0 0 V A 1 2 0 0 W
P F : 1 . 0 0
Screen
No. 5
E V O - 3 0 1 2 C h a r g i n g
0 - B u l k S t a g e
G E N : 1 2 0 . 0 V 1 0 . 0 0 A
6 0 . 0 0 H z
Screen
No. 6
E V O - 3 0 1 2 F C h a r g i n g
0 - B u l k S t a g e
G E N : 1 2 0 0 V A 2 2 0 0 W
P F : 1 . 0 0
Screen
No. 7
ð ð ð ð
ð ð ð ð
ð
ð
E V O - 3 0 1 2 C h a r g i n g
0 - B u l k S t a g e
A C o u t : 1 2 0 . 0 V 1 0 . 0 0 A
6 0 . 0 0 H z
Screen
No. 4
ð
ð
E V O - 3 0 1 2 C h a r g i n g
B a t t e r y 2 5 . 0 C
H e a t s i n k 2 5 . 0 C
T r a n s f o r m e r 2 5 . 0 C
E V O - 3 0 1 2 C h a r g i n g
E V O V e r : x . x x 1 0 = 1
R C V e r : x . x x
2 0 1 7 / 0 4 / 2 1 1 5 : 0 0
Screen
No. 8
Screen
No. 9

18 | SAMLEX AMERICA INC. SAMLEX AMERICA INC. | 19
SECTION 3 | Operation
3.6.4.3 Details of Charging Proles in Charging Mode Screens
Refer to the 2nd Line of the following Charging Mode Screens:
Fig 3.3(a) under Section 3.6.4.1 for Models EVO-1212F / 1212F-HW / 1224F / 1224F-HW
Fig 3.3(b) under Section 3.6.4.2 for Models EVO-2212 / 3012 / 2224 / 4024
Details of information related to this line on the screen are shown in Table 3.2.
Table 3.2 Details of Charging Proles indicated in 2nd line of Charging Mode Screens
2nd Line of Screens in
Fig 3.3(a) & 3.3(b)
Description
0- Bulk Stage Constant Current, Bulk Stage, Charging Prole=0 (3-Stage Adaptive)
1- Bulk Stage Constant Current, Bulk Stage, Charging Prole=1 (3-Stage Type 1)
2- Bulk Stage Constant Current, Bulk Stage, Charging Prole=2 (3-Stage Type 2)
3- Bulk Stage Constant Current, Bulk Stage, Charging Prole=3 (2-Stage Type 1)
4- Bulk Stage Constant Current, Bulk Stage, Charging Prole=4 (2-Stage Type 2)
E- Bulk Stage Constant Current, Bulk Stage, Equalize - 4Stages (1=Yes)
0- Absorption Stage Constant Voltage, Absorption Stage, Charging Prole=0 (3-Stage Adaptive)
1- Absorption Stage Constant Voltage, Absorption Stage, Charging Prole=1 (3-Stage Type 1)
2- Absorption Stage Constant Voltage, Absorption Stage, Charging Prole=2 (3-Stage Type 2)
3- Absorption Stage Constant Voltage, Absorption Stage, Charging Prole=3 (2-Stage Type 1)
4- Absorption Stage Constant Voltage, Absorption Stage, Charging Prole=4 (2-Stage Type 2)
E- Absorption Stage Constant Voltage, Absorption Stage, Equalize - 4Stages (1=Yes)
E- Equalization Stage Constant Voltage, Equalization Stage, Equalize - 4Stages (1=Yes)
0-Float Stage Float Stage, Charging Prole=0 (3-Stage Adaptive)
1- Float Stage Float Stage, Charging Prole=1 (3-Stage Type 1)
2- Float Stage Float Stage, Charging Prole=2 (3-Stage Type 2)
3- Charger Off Charger Off, AC Bypass, Charging Prole=3 (2-Stage Type 1)
Charger Off by BMS Charger Off by BMS (Battery Type=Lithium)
Inverter Stop by BMS Inverter Stop by BMS (Battery Type: 1=Lithium)
Inverter Off Charger only, Inverter Off (Online Mode=2, Charger only)

20 | SAMLEX AMERICA INC.
SECTION 3 | Operation
3.6.5 Menu Maps for Power Save Mode Screens
Menu Maps for the Operating Mode Screens for the Power Save Mode are shown as follows:
Section 3.6.5.1: Fig 3.4(a) for Models EVO-1212F / 1212F-HW / 1224F / 1224F-HW
(Model No. shown in the screens is EVO-1212F).
Section 3.6.5.2: Fig 3.4(b) for Models EVO-2212 / 3012 / 2224 / 4024 (Model No. shown
in the screens is EVO-3012).
3.6.5.1 Menu Maps for Power Save Mode Screens for EVO-1212F /
1212F-HW / 1224F / 1224-HW
NOTES:
1. The 1st line of the display screen shows Model
No. on the left and the Operating Mode“
PowerSave” on the right
2. The 2nd, 3rd and the 4th lines show various oper-
ating parameters and their values
3. Use Up ñand Down òKeys to navigate to the
desired screen.
Up Key
Down Key
E V O - 1 2 1 2 F P o w e r S a v e
A C o u t p u t : 0 . 0 V
< 0 . 1 0 A
6 0 . 0 0 H z
Screen
No. 1
E V O - 1 2 1 2 F P o w e r S a v e
A C o u t p u t : < 1 2 W
< 1 2 V A
P F = 0 . 0 0 0
Screen
No. 2
E V O - 1 2 1 2 F P o w e r S a v e
A C I n p u t : 1 2 0 . 0 V
< 0 . 1 0 A
6 0 . 0 0 H z
Screen
No. 3
E V O - 1 2 1 2 F P o w e r S a v e
B a t t e r y : 1 2 . 0 0 V
0 . 0 A
E x t e r n a l : 0 . 0 A
Screen
No. 5
E V O - 1 2 1 2 F P o w e r S a v e
B a t t e r y 2 5 . 0 C
H e a t s i n k 2 5 . 0 C
T r a n s f o r m e r 2 5 . 0 C
Screen
No. 6
E V O - 1 2 1 2 F P o w e r S a v e
E V O V e r : x . x x I D = 1
R C V e r : x . x x
2 0 1 7 / 0 4 / 2 1 1 5 : 0 0
Screen
No. 7
ð ð ð ð
ð ð ð ð
ð
ð
E V O - 1 2 1 2 F P o w e r S a v e
A C I n p u t : < 1 2 W
< 1 2 V A
P F = 0 . 0 0 0
Screen
No. 4
ð
ð
Fig 3.4(a) Menu Map for Power Save Mode Screens for EVO-1212F /
1212F-HW / 1224F / 1224F-HW (Model No. shown is EVO-1212F)
Other manuals for Evolution Series
3
This manual suits for next models
1
Table of contents
Other Samlexpower Remote Control manuals
Popular Remote Control manuals by other brands

Mitsubishi Electric
Mitsubishi Electric MAC-821SC-E operating instructions

Simpnic
Simpnic R1 Quick installation guide

Brightstar
Brightstar BR100L Programming instructions

Gira
Gira 5352 10 operating instructions

jedi LIGHTING
jedi LIGHTING JE0189081 User instruction

Continental Refrigerator
Continental Refrigerator PAG-KEY-315-180528 Product description