1. Switch on/power off
In energized state , the system is under standby , when first press button
for 3 seconds, the system is switched on, the room temperature will display
on the screen, when second press this button , the system and all loads will
be turned off.if the button color shows green means on-state,and red color
means closed
2. Light wave function
Under the power on state,press button,start the light wave function ,green
button means turn on,and red means turn off,the light wave temperature
will memory last setting, time is 60 minuets
Light wave temperature setting:in light wave state,press button to adjust
the temperature,the adjustment range is 30-70 degree,every press could
increase only 1 degree, if no operation exceed 8 seconds,the screen will
returns to display the current actual temperature.
Press C/F button to change the temperature display between
℃/℉.
Light wave time setting:in light wave state,press button to adjust time,the
adjustment range is 5-60 minutes,every press could increase only 1 minute.
if no operation exceed 8 seconds,the screen will returns to display the
current actual time.
3. Bluetooth audio function
Under the power on state,press button,start the Bluetooth audio func-
tion,green button means turn on,and red means turn off, turn on the Blue-
tooth function of your mobile device ,search and pairing it,then listen to the
music.
4. Light control system
Press button to turn on the color light( the light color memory last setting),green button means
turn on,and red means turn off,under the light on conditions,long press this button 5 seconds
could change the light color,every press could change only one color,cyclic Conversion and
memory(L1 =white color,L2=red+blue color,L3=blue color,L4=blue+green color,L5=green
color,L6=green+red color,L7=red color,L8=every color mutation,L9=every color Gradual)
if no operation exceed 8 seconds,the system exit light control mode.
The system has a DV12V oxygen bar function, when system under standby mode,the oxygen
bar function can immediately powered.
Fault detection and protection
1. High temperature protection
If the detection temperature of sensor has exceed 80 degree,the two digital tubes display”H-
H”at the same time,the alarm flashed and all function stopped,even if the temperature drops to
75 degree,all function can not be restore anymore,it must be powered off first then powered on
again.
2. Sensor fault detection
open circuit:Two digital tubes display” E0 “and flash,buzzer alarmed,all function can not be
open anymore, fault eliminated then can be used normally
Short circuit:Two digital tubes display” E1 “and flash,buzzer alarmed,all function can not be
open anymore,fault eliminated then can be used normally